ALAndrew J. Lewis

Andrew J. Lewis

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Andrew J. Lewis has a total of 149 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Automated evaluation of a key comparison on gauge blocks applying the digital calibration certificate (DCC) and digital metrological expert (DME)

    by Guido Bartl, Hugo Gasca-Aragon, Daniel Hutzschenreuter, Richard Koops, Antti Lassila, Andrew Lewis, Georg Zechner

    This article provides a demonstration of the capabilities of the digital metrological expert (DME) in facilitating the evaluation of interlaboratory comparison results, for the first time in the field of dimensional measurements. Using the example case of gauge blocks, it is shown how data provided by the digital calibration certificate (DCC) XML schema enable the automated evaluation of the comparison based on machine-interpretable data formats. Therefore, a simulated interlaboratory comparison with artificial gauge block measurement results acts as a proof-of-principle test to assess the combination of DCC and DME close to practice. Applying automated statistical analyses, including the calculation of reference values, degrees of equivalence, and detection of outliers at a level of significance of 5 %, the DME allows for the assessment of different evaluation methods to select suitable approaches. Compared to the usual practice of a (semi-)manual evaluation of intercomparisons carried out by human experts, the key benefits include reduced time and effort, consistency in results, and the potential prevention of human errors. The demonstration paves the way for easy adaptation to similar use cases.

  • Open Access

    CORRIGENDUM: Angles in the SI—a practical dimensional metrologist viewpoint * (2026 Metrologia 63 013001)

    by Andrew J Lewis, Timothy J Coveney

    In this corrigendum we correct some numerical and symbol errors in table 2 found in the original manuscript. These errors were independently detected by the authors and a reader during the final production of the paper, but too late for consideration as proof corrections. Table 2 is our version of a table from a paper by Lehman et al showing how our proposal for the radian would fit with their scheme. We took their table and extended it to include the radian, taking into account their later published corrigendum. However additional errors, which persisted after the corrigendum by Lehman et al were not noticed until the final stages of publication of our paper. This corrigendum fixes these errors and doing so has required a small additional change to the symbols in tables 1 and 2. Of our corrected lines in table 2 for the entries for m, kg, A and rad, the first three would also suffice as corrections to the Lehman paper. We thank the reader for informing us of the errors.

  • Open Access

    Angles in the SI—a practical dimensional metrologist viewpoint *

    by Andrew J Lewis, Timothy J Coveney

    The International System units of plane angle (radian) and solid angle (steradian) have been the subject of much international debate and discussion, stretching back over several decades. This letter presents the viewpoint from practising dimensional metrologists for whom the realisation of angular units is their responsibility.

  • The CCL-K11 ongoing key comparison. Final report for 2023

    by M Matus, H S Margolis, J Seppä, H Karlsson, C-H Hanquist, A J Lancaster, A J Lewis, M Brawer, M del Mar Pérez, M Bisi, et al.

    Main text: Six lasers from six national metrological institutes (NMIs) were compared in the year 2023 as part of the CCL-K11 ongoing key comparison, initiated by the 13th meeting of the Comité Consultative des Longueurs (CCL) in 2007. The absolute frequency of theses lasers was measured in three different node laboratories following the technical protocol for CCL-K11. All are practical realisations of the definition of the metre according to the MeP for the definition of the metre. Five standards are He-Ne-lasers stabilized on the f component of the R(127) 11-5 transitions of molecular iodine 127I2 with a wavelength of approximately 633 nm. The sixth standard is a fibre laser stabilized to the P(16) (ν1+ν3) transition of molecular acetylene 13C2H2 with a wavelength of approximately 1542 nm. The technical protocol was deliberately designed to accommodate artefacts of different wavelengths in a common framework. The results of these measurements are compiled in the present report. The comparison reports, as communicated by each participant, are included in the main document. This document constitutes the thirteenth final report for the ongoing key comparison CCL-K11. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/. The final report has been peer-reviewed and approved for publication by the CCL, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).


  • Editorial for the Metrologia Focus Issue on Length Metrology

    by Andrew J Lewis, Andrew Yacoot

    This Focus Issue of Metrologia was instigated by the Consultative Committee for Length’s Working Group on Strategic Planning when it met online in 2020 during the COVID-19 pandemic. Submission of articles started closely thereafter and was closed in September 2022. Covering a wide range of topics, the issue shows that despite the Coronavirus pandemic disrupting laboratory work, length metrology researchers have continued to deliver cutting edge research. The revised definition of the metre and its Mise en Pratique, both published in 2019, have stimulated further research and opened additional opportunities for developing length metrology capabilities. Articles related to the new Mise en Pratique are included in the issue, together with a range of articles demonstrating the breadth and ingenuity of current leading edge research in length metrology. A final paper indicates how metrology, with length used as an example, may be enhanced by a transition to a digital framework for realising the SI.


  • A digital framework for realising the SI—a proposal for the metre

    by Andrew J Lewis, Andrew Yacoot, Martin J T Milton, Andrew J Lancaster

    A current focus of the international metrology community is the digitalisation of documents, certificates and services in response to initiatives underway throughout industry and to the requirement to follow the principles of data being Findable, Accessible, Interoperable, and Reusable. We propose the key elements of a digital framework for the SI metre, at the point of realisation, showing how it may be implemented in practice. We give examples of direct benefits of this approach, which may be extended to other SI units.


  • Open Access

    The new mise en pratique for the metre—a review of approaches for the practical realization of traceable length metrology from 10−11 m to 1013 m

    by René Schödel, Andrew Yacoot, Andrew Lewis

    The revised International System of Units (SI) came into force on May 20, 2019. Simultaneously, updated versions of supporting documents for the practical realization of the SI base units (mises en pratique) were published. This review paper provides an overview of the updated mise en pratique for the SI base unit of length, the metre, that now gives practical guidance on realisation of traceable length metrology spanning 24 orders of magnitude. The review begins by showing how the metre may be primarily realized through time of flight and interferometric techniques using a variety of types of interferometer. Examples of techniques for measuring the interferometric phase and coping when the integer interference order is unknown are then described, together with examples of typical uncertainty contributions that may be encountered. The requirements for traceable nanoscale metrology and the need for an alternative secondary metre as identified by the Consultative Committee for Length’s Working Group on Nanometrology are outlined. These led to the inclusion in the mise en pratique of secondary realisations of the length unit at the nanometre and sub nanometre scale, based on the lattice spacing of silicon. Three measurement techniques using this secondary realisation are then described in detail. The paper concludes by emphasising that measurements made today over 24 order of magnitude are still compatible with measurements made using the metre as adopted over 200 years ago.


  • RAVEN-S: Design and Simulation of a Robot for Teleoperated Microgravity Rodent Dissection Under Time Delay

    by Andrew Lewis, David Drajeske, John Raiti, Angelique Berens, Jacob Rosen, Blake Hannaford

    The International Space Station (ISS) serves as a research lab for a wide variety of experiments including some that study the biological effects of microgravity and spaceflight using the Rodent Habitat and Microgravity Science Glovebox (MSG). Astronauts train for onboard dissections of rodents following basic training. An alternative approach for conducting these experiments is teleoperation of a robot located on the ISS from earth by a scientist who is proficient in rodent dissection. This pilot study addresses (1) the effects of extreme time delay on skill degradation during Fundamentals of Laparoscopic Surgery (FLS) tasks and rodent dissections using RAVEN II; (2) derivation and testing of rudimentary interaction force estimation; (3) elicitation of design requirements for an onboard dissection robot, RAVEN-S; and (4) simulation of the RAVEN-S prototype design with dissection data. The results indicate that the tasks’ completion times increased by a factor of up to 9 for a 3 s time delay while performing manipulation and cutting tasks (FLS model) and by a factor of up to 3 for a 0.75 s time delay during mouse dissection tasks (animal model). Average robot forces/torques of 14N/0.1Nm (peak 90N/0.75Nm) were measured along with average linear/angular velocities of 0.02m/s / 4rad/s (peak 0.1m/s / 40rad/s) during dissection. A triangular configuration of three arms with respect to the operation site showed the best configuration given the MSG geometry and the dissection tasks. In conclusion, the results confirm the feasibility of utilizing a surgically-inspired RAVEN-S robot for teleoperated rodent dissection for successful completion of the predefined tasks in the presence of communications time delay between the ISS and ground control.


  • Angle comparison using an autocollimator

    by Ralf D Geckeler, Andreas Just, Valentin Vasilev, Emilio Prieto, František Dvorácek, Slobodan Zelenika, Joanna Przybylska, Alexandru Duta, Ilya Victorov, Marco Pisani, et al.

    Autocollimators are versatile optical devices for the contactless measurement of the tilt angles of reflecting surfaces. An international key comparison (KC) on autocollimator calibration, EURAMET.L-K3.2009, was initiated by the European Association of National Metrology Institutes (EURAMET) to provide information on the capabilities in this field. The Physikalisch-Technische Bundesanstalt (PTB) acted as the pilot laboratory, with a total of 25 international participants from EURAMET and from the Asia Pacific Metrology Programme (APMP) providing measurements. This KC was the first one to utilise a high-resolution electronic autocollimator as a standard. In contrast to KCs in angle metrology which usually involve the full plane angle, it focused on relatively small angular ranges (±10 arcsec and ±1000 arcsec) and step sizes (10 arcsec and 0.1 arcsec, respectively). This document represents the approved final report on the results of the KC. Main text To reach the main text of this paper, click on Final Report . Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/ . The final report has been peer-reviewed and approved for publication by the CCL, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).