Kristian Næser
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Kristian Næser has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Giacomo Savini
IRCCS Bietti Foundation, Rome, Italy
5 shared publications Jesper Flethøj Bregnhøj
Randers Regional Hospital, Randers, Denmark
3 shared publications- Adi Abulafia
Institute of Hematology Davidoff Cancer Center Rabin Medical Center Petah Tikva Israel
2 shared publications - Douglas D. Koch
Baylor College of Medicine
2 shared publications - Jack T. Holladay
Department of Ophthalmology, Baylor College of Medicine, Houston, Texas, USA
2 shared publications - Kyung-Sun Na
Department of Ophthalmology, College of Medicine, The Catholic University of Korea, Seoul, Korea
2 shared publications
Latest Publications
- 1 November 2025
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 51 (11) , 1039-1040
Reply: Accuracy of thick and thin intraocular lens power formulas using paraxial vergence calculation
- 1 November 2025
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 51 (11) , 1039-1040
Reply: Accuracy of thick and thin intraocular lens power formulas using paraxial vergence calculation
- 1 June 2025
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 51 (6) , 537
Comment on: Impact of quality indicators on variability of keratometry measurements using a SS-OCT–based optical biometer
- 1 June 2025
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 51 (6) , 537
Comment on: Impact of quality indicators on variability of keratometry measurements using a SS-OCT–based optical biometer
- 1 June 2025
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 51 (6) , 447-455
Standards for analyzing astigmatic outcomes: Part II: Recommended statistical methods
Surgically induced astigmatism (SIA) is the astigmatic component of the surgically induced refractive change. Vector prediction error (PE) is the key expression for evaluating refractive surgery, defined as the vector difference between the postoperatively observed refractive astigmatism and the refractive astigmatism predicted from the preoperative measurements. Astigmatic analysis of the SIA and PE includes both univariate and bivariate analyses. The magnitude of the refractive astigmatism is a predictor of visual function and a valuable component of astigmatic reporting. For vector metrics from bivariate analysis, data should be analyzed and displayed with double-angle plots. Vector calculations can be performed independent of or relative to a reference meridian or axis. Double-angle plots with convex polygons and statistical analysis for astigmatism data can be obtained easily with the wrap-up functions from the Wilcox-Holladay-Wang-Koch Statistical Software using the free software R Project for Statistical Computing or with Eyetemis software, which is also available online.
- 1 June 2025
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 51 (6) , 447-455
Standards for analyzing astigmatic outcomes: Part II: Recommended statistical methods
Surgically induced astigmatism (SIA) is the astigmatic component of the surgically induced refractive change. Vector prediction error (PE) is the key expression for evaluating refractive surgery, defined as the vector difference between the postoperatively observed refractive astigmatism and the refractive astigmatism predicted from the preoperative measurements. Astigmatic analysis of the SIA and PE includes both univariate and bivariate analyses. The magnitude of the refractive astigmatism is a predictor of visual function and a valuable component of astigmatic reporting. For vector metrics from bivariate analysis, data should be analyzed and displayed with double-angle plots. Vector calculations can be performed independent of or relative to a reference meridian or axis. Double-angle plots with convex polygons and statistical analysis for astigmatism data can be obtained easily with the wrap-up functions from the Wilcox-Holladay-Wang-Koch Statistical Software using the free software R Project for Statistical Computing or with Eyetemis software, which is also available online.
- 1 June 2025
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 51 (6) , 440-446
Standards for analyzing astigmatic outcomes: Part I: astigmatism basics
Astigmatism is the difference between the orthogonal principal planes of minimal and maximal powers of a toric surface, lens, or refraction. Corneal astigmatism is a common condition, and studies indicate that over 60% of individuals have more than 0.50 diopters of astigmatism. Corneal astigmatism is measured in various ways, and measurements from different devices are usually not interchangeable because of variations in technology and the corneal regions that are imaged. The integrity of the ocular surface is critically important for accurately measuring corneal astigmatism. Optimizing the ocular surface before cataract surgery can significantly improve the accuracy of preoperative astigmatism measurements and refractive outcomes. It is advisable to obtain at least 2 or preferably 3 measurements when measuring corneal astigmatism. When a discrepancy in astigmatism meridian and magnitude occurs between the measurements, it is advisable to settle or at least minimize this discrepancy by repeating the measurements after optimizing the ocular surface. Posterior corneal astigmatism is an important component of total corneal astigmatism. Lens tilt can also induce visually significant refractive astigmatism and ideally should be accounted for in toric intraocular lens planning.
- 1 June 2025
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 51 (6) , 440-446
Standards for analyzing astigmatic outcomes: Part I: astigmatism basics
Astigmatism is the difference between the orthogonal principal planes of minimal and maximal powers of a toric surface, lens, or refraction. Corneal astigmatism is a common condition, and studies indicate that over 60% of individuals have more than 0.50 diopters of astigmatism. Corneal astigmatism is measured in various ways, and measurements from different devices are usually not interchangeable because of variations in technology and the corneal regions that are imaged. The integrity of the ocular surface is critically important for accurately measuring corneal astigmatism. Optimizing the ocular surface before cataract surgery can significantly improve the accuracy of preoperative astigmatism measurements and refractive outcomes. It is advisable to obtain at least 2 or preferably 3 measurements when measuring corneal astigmatism. When a discrepancy in astigmatism meridian and magnitude occurs between the measurements, it is advisable to settle or at least minimize this discrepancy by repeating the measurements after optimizing the ocular surface. Posterior corneal astigmatism is an important component of total corneal astigmatism. Lens tilt can also induce visually significant refractive astigmatism and ideally should be accounted for in toric intraocular lens planning.
- 1 March 2025
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 51 (3) , 182-187
Accuracy of thick and thin intraocular lens power formulas using paraxial vergence calculation
Purpose: To compare the prediction errors (PEs) of several thick intraocular lens (IOL) formulas with a thin lens approach using variations of the same paraxial vergence calculation formula. Setting: Department of Ophthalmology, Randers Regional Hospital, Denmark. Design: Prospective, noninterventional study. Methods: Optical low coherence reflectometry biometry was prospectively and consecutively performed in 132 eyes with subsequent phacoemulsification and insertion of the same aspheric IOL model. Clinical refraction was performed 2 months postoperatively. Retrospectively, the same paraxial vergence formula was used and only the methods were varied for calculating the postoperative IOL position, thickness, and curvatures to construct 4 formulas: Næser I formula based on thick lens calculation using the manufacturer's cutting card information, Næser II formula based on thick lens calculation using calculated IOL data from open sources, Næser III formula based on thick lens calculation and a fixed IOL thickness of 0.62 mm, and Næser IV formula based on thin lens calculation with fixed IOL position 0.31 mm anterior to the postoperative capsule. Each formula was optimized separately, hereby assuring a mean error of zero. The PE was defined as the difference between the measured and predicted spherical equivalent refraction. Results: Mean absolute error amounted to 0.30 ± 0.26 diopters for all 4 formulas with no statistically significant difference. PE averaged zero for short, normal, and long eyes. Conclusions: The additional optical information provided by thick IOL calculations seems insignificant compared with other sources of error, related to the accuracy of IOL manufacturing, crystalline lens refractive index, and postoperative refraction.
- 1 March 2025
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 51 (3) , 182-187
Accuracy of thick and thin intraocular lens power formulas using paraxial vergence calculation
Purpose: To compare the prediction errors (PEs) of several thick intraocular lens (IOL) formulas with a thin lens approach using variations of the same paraxial vergence calculation formula. Setting: Department of Ophthalmology, Randers Regional Hospital, Denmark. Design: Prospective, noninterventional study. Methods: Optical low coherence reflectometry biometry was prospectively and consecutively performed in 132 eyes with subsequent phacoemulsification and insertion of the same aspheric IOL model. Clinical refraction was performed 2 months postoperatively. Retrospectively, the same paraxial vergence formula was used and only the methods were varied for calculating the postoperative IOL position, thickness, and curvatures to construct 4 formulas: Næser I formula based on thick lens calculation using the manufacturer's cutting card information, Næser II formula based on thick lens calculation using calculated IOL data from open sources, Næser III formula based on thick lens calculation and a fixed IOL thickness of 0.62 mm, and Næser IV formula based on thin lens calculation with fixed IOL position 0.31 mm anterior to the postoperative capsule. Each formula was optimized separately, hereby assuring a mean error of zero. The PE was defined as the difference between the measured and predicted spherical equivalent refraction. Results: Mean absolute error amounted to 0.30 ± 0.26 diopters for all 4 formulas with no statistically significant difference. PE averaged zero for short, normal, and long eyes. Conclusions: The additional optical information provided by thick IOL calculations seems insignificant compared with other sources of error, related to the accuracy of IOL manufacturing, crystalline lens refractive index, and postoperative refraction.
- Open Access
- 4 July 2024
- Published by Springer Nature
- p. 835-848
Astigmatism Notation: Dealing with Vectors
Net astigmatisms and spherocylinders are complex formats with magnitudes in diopters and directions in degrees. Both magnitudes and directions entities must be converted to vectors to allow for any kind of calculation. This chapter describes the principles for conversion of corneal and refractive data to dioptric vectors. Næser’s polar value dioptric vectors are detailed and other dioptric vector formats (Thibos, Holladay and Lang’s power matrix) are reviewed. The appropriate statistical methods for univariate and bivariate analysis are described, a terminology is suggested, and practical calculations are demonstrated.
- 4 July 2024
- Published by Springer Nature
- p. 835-848
Open AccessAstigmatism Notation: Dealing with Vectors
Net astigmatisms and spherocylinders are complex formats with magnitudes in diopters and directions in degrees. Both magnitudes and directions entities must be converted to vectors to allow for any kind of calculation. This chapter describes the principles for conversion of corneal and refractive data to dioptric vectors. Næser’s polar value dioptric vectors are detailed and other dioptric vector formats (Thibos, Holladay and Lang’s power matrix) are reviewed. The appropriate statistical methods for univariate and bivariate analysis are described, a terminology is suggested, and practical calculations are demonstrated.
- Open Access
- 18 December 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (24) , 3687
Comparison of Automated Keratometer and Scheimpflug Tomography for Predicting Refractive Astigmatism in Pseudophakic Eyes
Purpose: To analyse the correspondence between refractive astigmatism and corneal astigmatism in pseudophakic eyes with non-toric intraocular lenses. Setting: Yeouido St. Mary hospital, Seoul, Republic of Korea. Design: Evaluation of a diagnostic test instrument. Methods: This retrospective study included 95 eyes of 95 patients. Corneal astigmatism was measured with an automated keratometer (RK-5, Canon) and Scheimpflug tomography (Pentacam HR, Oculus). Refractive astigmatism was compared to keratometric astigmatism (based on anterior corneal measurements only), equivalent K-reading, and total corneal astigmatism (both based on anterior and posterior corneal measurements). Vector analysis was carried out by Næser’s polar value method. The accuracy was defined as the average magnitude of the vectorial difference in astigmatism (DA). Each corneal measurement was optimized in retrospect by a multiple linear regression equation between refractive and corneal astigmatism. Results: Keratometric astigmatism overestimated with-the-rule (WTR) refractive astigmatism and underestimated against-the-rule (ATR) refractive astigmatism. Several measurements based on both corneal surfaces’ values did not show any statistically significant difference with respect to refractive astigmatism. The mean corneal astigmatism by total corneal refractive power (TCRP) at 4.0 mm (zone/pupil) produced the lowest mean arithmetic DA and the highest percentage of eyes with a DA ≤ 0.50 dioptre. After optimization, the accuracies of automated KA and TCRP 4.0 mm (zone/pupil) were similar. Conclusions: Total corneal astigmatism measured by Scheimpflug tomography at a 4.0 mm zone centered on the pupil accurately reflects the refractive astigmatism in pseudophakic eyes. However, the accuracy of total corneal astigmatism is not different from automated KA after optimization.
- 18 December 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (24) , 3687
Open AccessComparison of Automated Keratometer and Scheimpflug Tomography for Predicting Refractive Astigmatism in Pseudophakic Eyes
Purpose: To analyse the correspondence between refractive astigmatism and corneal astigmatism in pseudophakic eyes with non-toric intraocular lenses. Setting: Yeouido St. Mary hospital, Seoul, Republic of Korea. Design: Evaluation of a diagnostic test instrument. Methods: This retrospective study included 95 eyes of 95 patients. Corneal astigmatism was measured with an automated keratometer (RK-5, Canon) and Scheimpflug tomography (Pentacam HR, Oculus). Refractive astigmatism was compared to keratometric astigmatism (based on anterior corneal measurements only), equivalent K-reading, and total corneal astigmatism (both based on anterior and posterior corneal measurements). Vector analysis was carried out by Næser’s polar value method. The accuracy was defined as the average magnitude of the vectorial difference in astigmatism (DA). Each corneal measurement was optimized in retrospect by a multiple linear regression equation between refractive and corneal astigmatism. Results: Keratometric astigmatism overestimated with-the-rule (WTR) refractive astigmatism and underestimated against-the-rule (ATR) refractive astigmatism. Several measurements based on both corneal surfaces’ values did not show any statistically significant difference with respect to refractive astigmatism. The mean corneal astigmatism by total corneal refractive power (TCRP) at 4.0 mm (zone/pupil) produced the lowest mean arithmetic DA and the highest percentage of eyes with a DA ≤ 0.50 dioptre. After optimization, the accuracies of automated KA and TCRP 4.0 mm (zone/pupil) were similar. Conclusions: Total corneal astigmatism measured by Scheimpflug tomography at a 4.0 mm zone centered on the pupil accurately reflects the refractive astigmatism in pseudophakic eyes. However, the accuracy of total corneal astigmatism is not different from automated KA after optimization.
- Open Access
- 29 August 2023
- Published by MDPI AG in Preprints.org
Comparison of Automated Keratometer and Scheimpflug Tomography for Predicting Refractive Astigmatism in Pseudophakic Eyes
Purpose: To analyze the correspondence between refractive astigmatism and corneal astigmatism in pseudophakic eyes with non-toric intraocular lenses. Setting: Yeouido St. Mary hospital, Seoul, South Korea Design: Evaluation of a diagnostic test instrument. Methods: This retrospective study included 95 eyes of 95 patients. Corneal astigmatism was measured with an automated keratometer (RK-5, Canon) and Scheimpflug tomography (Pentacam HR, Oculus). Refractive astigmatism was compared to keratometric astigmatism (based on anterior corneal measurements only), Equivalent K Reading and total corneal astigmatism (both based on anterior and posterior corneal measurements). Vector analysis was carried out by Næser’s polar value method. The accuracy was defined as the average magnitude of the vectorial difference in astigmatism (DA). Each corneal measurement was optimized in retrospect by a multiple linear regression equation between refractive and corneal astigmatism. Results: Keratometric astigmatism overestimated with-the-rule (WTR) refractive astigmatism and underestimated against-the-rule (ATR) refractive astigmatism. Several measurements based on both corneal surfaces values did not show any statistically significant difference with respect to refractive astigmatism. The mean corneal astigmatism by total corneal refractive power (TCRP) at 4.0 mm (zone/pupil) produced the lowest mean arithmetic DA and the highest percentage of eyes with a DA ≤0.50 diopter. After optimization, the accuracies of automated KA and TCRP 4.0 mm (zone/pupil) were similar. Conclusions: Total corneal astigmatism measured by the Scheimpflug tomography at 4.0 mm zone centered on pupil, accurately reflects the refractive astigmatism in pseudophakic eyes. However, the accuracy of total corneal astigmatism is not different from automated KA after optimization.
- 29 August 2023
- Published by MDPI AG in Preprints.org
Open AccessComparison of Automated Keratometer and Scheimpflug Tomography for Predicting Refractive Astigmatism in Pseudophakic Eyes
Purpose: To analyze the correspondence between refractive astigmatism and corneal astigmatism in pseudophakic eyes with non-toric intraocular lenses. Setting: Yeouido St. Mary hospital, Seoul, South Korea Design: Evaluation of a diagnostic test instrument. Methods: This retrospective study included 95 eyes of 95 patients. Corneal astigmatism was measured with an automated keratometer (RK-5, Canon) and Scheimpflug tomography (Pentacam HR, Oculus). Refractive astigmatism was compared to keratometric astigmatism (based on anterior corneal measurements only), Equivalent K Reading and total corneal astigmatism (both based on anterior and posterior corneal measurements). Vector analysis was carried out by Næser’s polar value method. The accuracy was defined as the average magnitude of the vectorial difference in astigmatism (DA). Each corneal measurement was optimized in retrospect by a multiple linear regression equation between refractive and corneal astigmatism. Results: Keratometric astigmatism overestimated with-the-rule (WTR) refractive astigmatism and underestimated against-the-rule (ATR) refractive astigmatism. Several measurements based on both corneal surfaces values did not show any statistically significant difference with respect to refractive astigmatism. The mean corneal astigmatism by total corneal refractive power (TCRP) at 4.0 mm (zone/pupil) produced the lowest mean arithmetic DA and the highest percentage of eyes with a DA ≤0.50 diopter. After optimization, the accuracies of automated KA and TCRP 4.0 mm (zone/pupil) were similar. Conclusions: Total corneal astigmatism measured by the Scheimpflug tomography at 4.0 mm zone centered on pupil, accurately reflects the refractive astigmatism in pseudophakic eyes. However, the accuracy of total corneal astigmatism is not different from automated KA after optimization.
- 27 June 2022
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 48 (10) , 1217-1218
Accuracy, trueness, and precision for refractive surgery to correct astigmatism: which metrics should be used?
An abstract is unavailable. This article is available as a PDF only.
- 27 June 2022
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 48 (10) , 1217-1218
Accuracy, trueness, and precision for refractive surgery to correct astigmatism: which metrics should be used?
An abstract is unavailable. This article is available as a PDF only.
- 9 June 2022
- Published by Taylor & Francis in Orbit
- Vol. 43 (1) , 147-150
A rare case of lacrimal sac angioleiomyoma managed with dacryocystectomy and turbinectomy
We report a rare case of a lacrimal sac angioleiomyoma. A 56-year-old woman complained of pain in the right medial canthal region over a period of 2 years. There were no complaints of epiphora or ocular infection, and no visible or palpable masses in the medial canthal region. Computed tomography scan revealed a solid tumor of the lacrimal sac expanding to the nasolacrimal duct and protruding under the inferior turbinate. The tumor was removed by external dacryocystectomy combined with endonasal, endoscopic anterior turbinectomy, and nasal mucosal resection. Histological and immunohistological findings were consistent with an angioleiomyoma of the venous type. There was no recurrence of the tumor at the three-year follow-up. Angioleiomyomas should be included in the differential diagnosis of lacrimal sac tumors. The definitive diagnoses rely on histology and immunohistological reactions. The treatment is complete surgical resection.
- 9 June 2022
- Published by Taylor & Francis in Orbit
- Vol. 43 (1) , 147-150
A rare case of lacrimal sac angioleiomyoma managed with dacryocystectomy and turbinectomy
We report a rare case of a lacrimal sac angioleiomyoma. A 56-year-old woman complained of pain in the right medial canthal region over a period of 2 years. There were no complaints of epiphora or ocular infection, and no visible or palpable masses in the medial canthal region. Computed tomography scan revealed a solid tumor of the lacrimal sac expanding to the nasolacrimal duct and protruding under the inferior turbinate. The tumor was removed by external dacryocystectomy combined with endonasal, endoscopic anterior turbinectomy, and nasal mucosal resection. Histological and immunohistological findings were consistent with an angioleiomyoma of the venous type. There was no recurrence of the tumor at the three-year follow-up. Angioleiomyomas should be included in the differential diagnosis of lacrimal sac tumors. The definitive diagnoses rely on histology and immunohistological reactions. The treatment is complete surgical resection.