Do Youn Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Do Youn Kim has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Chiheon Kwon
Medical Device Research Center, Department of Biomedical Research Institute, Chungnam National University Hospital, Daejeon, Republic of Korea
1 shared publication - Hee Chan Kim
Department of Biomedical Engineering, Seoul National University College of Medicine, Seoul, Republic of Korea
1 shared publication - Joong Woo Ahn
Samsung Electronics, Suwon, South Korea
1 shared publication - Yunseo Ku
Department of Biomedical Research Institute, Chungnam National University Hospital, Daejeon, Korea
1 shared publication
Latest Publications
- Open Access
- 1 January 2018
- Published by XMLink in Journal of Korean Medical Science
- Vol. 33 (21) , e154
Electro-deposited Nanoporous Platinum Electrode for EEG Monitoring
One of the key issues in electroencephalogram (EEG) monitoring is accurate signal acquisition with less cumbersome electrodes. In this study, the L2 phase electro-deposited nanoporous platinum (L2-ePt) electrode is introduced, which is a new type of electrode that utilizes a stable nanoporous platinum surface to reduce the skin-electrode impedance. L2-ePt electrodes were fabricated using electro-deposition technique. Then, the effect of the nanoporous surface on the surface roughness and the electrode impedance were observed from the L2-ePt electrodes and the flat platinum (FlatPt) electrode. The skin-electrode impedances of the L2-ePt electrodes, a gold cup electrode, and the FlatPt electrode were evaluated when placed on the hairy occipital area of the head in ten subjects. For the validation of using the L2-ePt electrode, a correlational analysis of the alpha rhythms was performed in the same subjects for simultaneous EEG recordings using the L2-ePt and clinically-used EEG electrodes. The results indicated that the L2-ePt electrode with a roughness factor of 200 had the lowest mean impedance performance. Moreover, the proposed L2-ePt electrode showed a significantly lower mean skin-electrode impedance than the FlatPt electrode. Finally, the EEG signal quality recorded by the L2-ePt electrode (r = 0.94) was comparable to that of the clinically-used gold cup electrode. Based on these results, the proposed L2-ePt electrode is suitable for use in various high-quality EEG applications.
- 1 January 2018
- Published by XMLink in Journal of Korean Medical Science
- Vol. 33 (21) , e154
Open AccessElectro-deposited Nanoporous Platinum Electrode for EEG Monitoring
One of the key issues in electroencephalogram (EEG) monitoring is accurate signal acquisition with less cumbersome electrodes. In this study, the L2 phase electro-deposited nanoporous platinum (L2-ePt) electrode is introduced, which is a new type of electrode that utilizes a stable nanoporous platinum surface to reduce the skin-electrode impedance. L2-ePt electrodes were fabricated using electro-deposition technique. Then, the effect of the nanoporous surface on the surface roughness and the electrode impedance were observed from the L2-ePt electrodes and the flat platinum (FlatPt) electrode. The skin-electrode impedances of the L2-ePt electrodes, a gold cup electrode, and the FlatPt electrode were evaluated when placed on the hairy occipital area of the head in ten subjects. For the validation of using the L2-ePt electrode, a correlational analysis of the alpha rhythms was performed in the same subjects for simultaneous EEG recordings using the L2-ePt and clinically-used EEG electrodes. The results indicated that the L2-ePt electrode with a roughness factor of 200 had the lowest mean impedance performance. Moreover, the proposed L2-ePt electrode showed a significantly lower mean skin-electrode impedance than the FlatPt electrode. Finally, the EEG signal quality recorded by the L2-ePt electrode (r = 0.94) was comparable to that of the clinically-used gold cup electrode. Based on these results, the proposed L2-ePt electrode is suitable for use in various high-quality EEG applications.