Chiheon Kwon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Chiheon Kwon has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Hee Chan Kim
Department of Biomedical Engineering, Seoul National University College of Medicine, Seoul, Republic of Korea
2 shared publications - Yunseo Ku
Department of Biomedical Research Institute, Chungnam National University Hospital, Daejeon, Korea
2 shared publications - Do Youn Kim
Interdisciplinary Program for Bioengineering, Graduate School, Seoul National University, Seoul, Korea
1 shared publication - Iqram Hussain
Department of Anesthesiology, Weill Cornell Medicine, Cornell University, New York, NY 10065, USA
1 shared publication - Joong Woo Ahn
Samsung Electronics, Suwon, South Korea
1 shared publication - Myung-Whan Suh
Department of Otorhinolaryngology-Head and Neck Surgery, Seoul National University Hospital, Seoul, Korea
1 shared publication
Latest Publications
- 22 August 2024
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 255, 108371
An interpretable tinnitus prediction framework using gap-prepulse inhibition in auditory late response and electroencephalogram
- 22 August 2024
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 255, 108371
An interpretable tinnitus prediction framework using gap-prepulse inhibition in auditory late response and electroencephalogram
- Open Access
- 1 January 2018
- Published by XMLink in Journal of Korean Medical Science
- Vol. 33 (21) , e154
Electro-deposited Nanoporous Platinum Electrode for EEG Monitoring
One of the key issues in electroencephalogram (EEG) monitoring is accurate signal acquisition with less cumbersome electrodes. In this study, the L2 phase electro-deposited nanoporous platinum (L2-ePt) electrode is introduced, which is a new type of electrode that utilizes a stable nanoporous platinum surface to reduce the skin-electrode impedance. L2-ePt electrodes were fabricated using electro-deposition technique. Then, the effect of the nanoporous surface on the surface roughness and the electrode impedance were observed from the L2-ePt electrodes and the flat platinum (FlatPt) electrode. The skin-electrode impedances of the L2-ePt electrodes, a gold cup electrode, and the FlatPt electrode were evaluated when placed on the hairy occipital area of the head in ten subjects. For the validation of using the L2-ePt electrode, a correlational analysis of the alpha rhythms was performed in the same subjects for simultaneous EEG recordings using the L2-ePt and clinically-used EEG electrodes. The results indicated that the L2-ePt electrode with a roughness factor of 200 had the lowest mean impedance performance. Moreover, the proposed L2-ePt electrode showed a significantly lower mean skin-electrode impedance than the FlatPt electrode. Finally, the EEG signal quality recorded by the L2-ePt electrode (r = 0.94) was comparable to that of the clinically-used gold cup electrode. Based on these results, the proposed L2-ePt electrode is suitable for use in various high-quality EEG applications.
- 1 January 2018
- Published by XMLink in Journal of Korean Medical Science
- Vol. 33 (21) , e154
Open AccessElectro-deposited Nanoporous Platinum Electrode for EEG Monitoring
One of the key issues in electroencephalogram (EEG) monitoring is accurate signal acquisition with less cumbersome electrodes. In this study, the L2 phase electro-deposited nanoporous platinum (L2-ePt) electrode is introduced, which is a new type of electrode that utilizes a stable nanoporous platinum surface to reduce the skin-electrode impedance. L2-ePt electrodes were fabricated using electro-deposition technique. Then, the effect of the nanoporous surface on the surface roughness and the electrode impedance were observed from the L2-ePt electrodes and the flat platinum (FlatPt) electrode. The skin-electrode impedances of the L2-ePt electrodes, a gold cup electrode, and the FlatPt electrode were evaluated when placed on the hairy occipital area of the head in ten subjects. For the validation of using the L2-ePt electrode, a correlational analysis of the alpha rhythms was performed in the same subjects for simultaneous EEG recordings using the L2-ePt and clinically-used EEG electrodes. The results indicated that the L2-ePt electrode with a roughness factor of 200 had the lowest mean impedance performance. Moreover, the proposed L2-ePt electrode showed a significantly lower mean skin-electrode impedance than the FlatPt electrode. Finally, the EEG signal quality recorded by the L2-ePt electrode (r = 0.94) was comparable to that of the clinically-used gold cup electrode. Based on these results, the proposed L2-ePt electrode is suitable for use in various high-quality EEG applications.