SRSeok Chang Ryu

Seok Chang Ryu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Seok Chang Ryu has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • On the Systematic Design Framework for Intuitive Interfaces in Telerobotic Operations: A Case Study in Surgical Robotics

    by Serin Cha, Yoonsue Choi, Hyeonji Bae, Chaewon Hwang, Seok Chang Ryu

    This paper proposes a design framework for intuitive interfaces in telerobotic operation, moving beyond outcome-based evaluation toward systematic interface design. A human-centered framework is introduced to guide interface strategy selection based on learning dynamics and to support implementation-level design decisions through analysis of human sensorimotor interaction. As a case study, the framework is instantiated through an embodiment-oriented index finger interface for controlling a distally bendable surgical instrument with unconventional kinematics. A telerobotic system was implemented, and the finger interface was compared with a familiarity-driven stylus interface in a dual-session human-subject study consisting of a training session and a retention session two weeks later. Results reveal a distinction between initial and later-stage interaction characteristics. While the stylus interface exhibited higher initial performance, the finger interface showed faster learning progression and achieved higher performance after learning stabilized. These findings suggest that embodiment-oriented interface design can support intuitive control by facilitating sensorimotor adaptation beyond immediate familiarity. Although evaluated in a surgical context, the proposed framework is applicable to the design of teleoperation interfaces for robotic systems with unconventional kinematics in broader domains.

  • Design and Mechanics of Active Needles: A Review

    by Sujin Yu, Yuri Lim, Soomin Kim, Seok Chang Ryu

    Steerable needles have been extensively studied in the medical robotics society for the past two decades, evolving from passive needles to active ones that enable independent motion at their distal tip via robotics technology. Extensive design and actuation options have been proposed for the more capable active needles, followed by a few studies on their path-planning and control techniques; however, no commercial systems are available for the clinical environment yet despite their clear benefit, i.e., improved steerability and versatility compared to the other existing types of needles. This paper reviews the state-of-the-art steerable needle studies to identify research gaps and aims to deepen understanding the mechanics of active needles in soft tissue, which is critical for design optimization, precise control, and preoperative planning but currently remains unclear. To simplify the analysis, this review suggests separating the mechanics of an active needle into two parts: one for each of the tip and the shaft, where the shaft can be understood similarly to the passive needle whose mechanics has been thoroughly studied compared to the active one. Therefore, investigating the tip mechanics, including tissue properties, tip loadings, and tip kinematics, can lead to the complete understanding of active needle mechanics, the next challenges.


  • Hybrid Tendon-Actuated and Soft Magnetic Robotic Platform for Pancreatic Applications

    by Benjamin Calmé, Adam Metcalf, Michael Brockdorff, Haneul Jang, Yoonsue Choi, Peter Lloyd, Seok Chang Ryu, Pietro Valdastri

    Magnetic Soft Continuum Robots (MSCR) are used in a wide variety of surgical interventions, including neurological, pancreatic, and cardiovascular procedures. To function effectively, these MSCRs require complex programmable magnetisation. However, they often suffer from limited manoeuvrability and imprecise positioning of the devices that carry them. Tendon-Driven Continuum Robots (TDCR) have the potential to address these issues. These navigation systems not only enable higher accuracy and precision but also offer the potential for remote control, thereby reducing clinicians' exposure to ionising radiation. Currently, MSCRs are deployed from manual flexible endoscopes without motion compensation, leading to uncertainty and trial-and-error insertion. In this study, the deployment of high aspect ratio MSCRs (60 mm long by 1.3 mm diameter) from a tendon-driven robot (25 cm long with a 2.8 mm diameter) is performed. By precisely positioning the deployment point, this paper evaluates the benefits of different magnetisation profiles. The comparison is carried out for a specific clinical scenario, assessing procedure time, the distance between the external permanent magnet (used for steering) and the MSCR, and the interaction force with the tissue. Clinical relevance is demonstrated through pancreatic and bile duct cannulation in a silicon phantom.


  • Open Access

    FEA Modeling of Soft Tissue Interaction for Active Needles With a Rotational Tip Joint

    by Luca Quagliato, Seok Chang Ryu

    A finite element analysis (FEA) model was developed for investigating the design and the tissue interaction of actively steerable needles with a rotational tip joint in soft tissue, based on the coupled Eulerian-Lagrangian (CEL) mesh. The new model is algorithmically simple in that the proposed CEL strategy allows needle insertion simulations along non-predetermined paths in soft tissue without the re-mesh at every direction change of the needle tip. For the features, various steering motions can be simulated and studied for different needle designs in a simpler approach by changing the needle geometry and boundary conditions. The developed FEA model, using the thoroughly measured material properties, was validated for predicting insertion path and estimating the tissue interaction forces inside two different gelatin tissue phantoms. Further, using the validated model, the effect of tip geometry on tissue was briefly investigated. Given bevel angles, it was found that the ratio of tip length to the diameter dominates the tissue damage gradient. The results demonstrate that the proposed model effectively examines the steering and tissue insertion of actively steerable needles and investigates the tip design to minimize the tissue damage by the needle steering.


  • Performance Evaluation of Optically Sensorized Tendons for Articulate Surgical Instruments

    by Rohith Karthikeyan, Kelly Sigmund, Yong-Lae Park, Seok Chang Ryu

    This study proposes an optically sensorized force-sensing tendon for minimally invasive surgical instruments. The tendon is composed of a high strength, polarization maintaining (PM) optical fiber with Bragg sensors (FBGs) that negate the cross-sensitivity of conventional FBGs. The PM-FBG fiber is locally reinforced with high stiffness Kevlar that enhances its load carrying capacity while enabling higher curvatures in tendon routing. The composite tendon has a mean diameter of ∼268 μm which preserves the form-factor of instruments within this scope. Importantly, the tendons can improve the functionality of such tools by enabling local force and tissue-resistance estimation. This paper explores the performance of these sensorized tendons in terms of strength, stability, response under dynamic load, friction, and sensitivity as a force measuring tool within an 18 Ga articulate Nitinol (NiTi) cannula (a proxy for potential applications). Results reaffirm the potential of a bi-modal sensing and actuation component within instruments for robotic surgery.


  • Design and Fabrication of Laser-Machined Hinge Joints on Miniature Tubes for Steerable Medical Devices

    by Shivanand Pattanshetti, Seok Chang Ryu

    With the proliferation of successful minimally invasive surgical techniques, comes the challenge of shrinking the size of surgical instruments further to facilitate use in applications such as neurosurgery, pediatric surgery, and needle procedures. This paper introduces laser machined, multi-degree-of-freedom (DOF) hinge joints embedded on tubes, as a possible means to realize such miniature instruments without the need for any assembly. A method to design such a joint for an estimated range of motion was explored. The effects of design and machining parameters on the mechanical interference, range of motion, and joint dislocation were analyzed. The extent of interference between the moving parts of the joint can be used to predict the range of motion of the joint for rigid tubes and future design optimization. The total usable workspace was also estimated using kinematic principles for a joint in series and for two sets of orthogonal joints. Our work can open up avenues to a new class of miniature robotic medical devices with hinge joints and a usable channel for drug delivery.


  • Design and characterization of rounded re-entrant honeycomb patterns for lightweight and rigid auxetic structures

    by Shengwei Chen, Seok Chang Ryu

    In the past decades, auxetic structures have received great attention because of their unique properties and outstanding performance over the traditional materials. However, the inherent porosity significantly reduce the moduli of the structures, making auxetic structures inappropriate for load-bearing components. This paper introduces a rounded re-entrant honeycomb (RH) pattern, in which the rounded corners stiffen the traditional RH pattern by suppressing the hinging mechanism. Four design parameters were identified to define a rounded RH unit cell, and the effect of each of them on structure properties was numerically studied. The results demonstrated the extended tunable range of mechanical properties and the possibility of building lightweight and stiffer structures, as well as significantly improved tensile and shear moduli. It is also noticed that the Poisson’s ratio shifts towards positive as the radius of the rounded corner increases. Several design strategies were proposed for achieving different design goals. The proposed rounded RH pattern could be an alternative for the existing RH pattern design, especially in the applications requesting for the lightweight and rigid auxetic structure.