Gerard Amorós-Figueras
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Gerard Amorós-Figueras has a total of 75 co-authors. Here are the top co-authors by number of shared publications:
- Jose Maria Guerra
Hospital de la Santa Creu i Sant Pau, Institut de Recerca Sant Pau (IR SANT PAU), CIBERCV, Universitat Autònoma de Barcelona , Barcelona
9 shared publications Esther Jorge
Hospital de la Santa Creu i Sant Pau, Institut de Recerca Sant Pau (IR SANT PAU), Universitat Autònoma de Barcelona (UAB), Barcelona, Spain
7 shared publications- Esther Jorge
Cardiology Service of Santa Creu i Sant Pau Hospital, Barcelona, Spain
6 shared publications Juan Cinca
Department of Cardiology, Hospital de la Santa Creu i Sant Pau, IIB-Sant Pau, UAB, CIBERCV, Barcelona, Spain
6 shared publications- Tomás García-Sánchez
Medical Education EMEA, Boston Scientific Corporation , Madrid
6 shared publications - Javier Rosell-Ferrer
Department of Electronic Engineering, Universitat Politècnica de Catalunya, Barcelona, Spain
5 shared publications
Latest Publications
- Open Access
- 23 March 2026
- Published by Frontiers Media SA in Frontiers in Cardiovascular Medicine
- Vol. 13, 1824781
Editorial: Bridging translational gaps in cardiovascular disease through large animal research
Cardiovascular diseases (CVDs) remain the leading cause of global mortality, accounting for nearly 16 20 million deaths annually. As we enter an era defined by rapid advancements in in silico modeling, 17 organ-on-a-chip technologies, and complex organoids, a critical question arises: Is the use of large 18 animal models still relevant in modern cardiovascular research? While alternative models o er high-19 throughput potential and address specific ethical concerns, they often struggle to replicate the 20 integrated systemic physiology electrophysiology and complex hemodynamics of the human heart. immunosuppression. This study is particularly significant for identifying the contribution of 66 immunosuppressive mediators and paracrine e ects that allow for stem cell retention and 67 endothelial recruitment, paving the way for o -the-shelf allogeneic stem cell therapies. 68Finally, the utility of many of these large animal models depends on the accuracy of our diagnostic 69 tools. In this research topic, Billig et al.( 6) have proposed a method to perform standardized 70 subxiphoid echocardiography (SE) in swine. The authors have described in detail the specific 71 surgical approach and imaging protocol and also have provided reference values for parameters 72 such as LV stroke volume, ejection fraction, and global longitudinal strain. Standardizing these 73 measurements is essential for ensuring reproducibility across di erent research centers and 74 improving the quality of translational cardiovascular data. 75In conclusion, the six articles presented in this Research Topic reinforce that large animal models 76 remain indispensable to translational medicine. Rather than being replaced by alternative methods, 77 new technologies allow these models to be improved and more closely mimic clinical reality, 78 thereby increasing their translational relevance. By bridging the gap between benchtop innovation 79 and the bedside, these advancements ensure that large animal research remains more essential 80 and rigorous than ever.In summary, this Research Topic highlights the indispensable role of large 81 animals in translating cardiovascular discoveries from the laboratory to the clinic. By refining our 82 models to be more pathomimetic and less stressful for the animals, we improve both the ethical 83 standing and the predictive power of our science. Whether through the development of "o -the-84 shelf" stem cell therapies, the rigorous testing of TAVI devices, or the standardization of imaging 85 protocols, these studies contribute to a more robust framework for cardiovascular innovation. 86We would like to thank all the authors for their innovative submissions and the reviewers for their 87 dedication to ensuring the quality of this Research Topic. We hope this collection serves as a 88 valuable resource for scientists and clinicians working to bridge the gap in cardiovascular therapy. 89 90
- 23 March 2026
- Published by Frontiers Media SA in Frontiers in Cardiovascular Medicine
- Vol. 13, 1824781
Open AccessEditorial: Bridging translational gaps in cardiovascular disease through large animal research
Cardiovascular diseases (CVDs) remain the leading cause of global mortality, accounting for nearly 16 20 million deaths annually. As we enter an era defined by rapid advancements in in silico modeling, 17 organ-on-a-chip technologies, and complex organoids, a critical question arises: Is the use of large 18 animal models still relevant in modern cardiovascular research? While alternative models o er high-19 throughput potential and address specific ethical concerns, they often struggle to replicate the 20 integrated systemic physiology electrophysiology and complex hemodynamics of the human heart. immunosuppression. This study is particularly significant for identifying the contribution of 66 immunosuppressive mediators and paracrine e ects that allow for stem cell retention and 67 endothelial recruitment, paving the way for o -the-shelf allogeneic stem cell therapies. 68Finally, the utility of many of these large animal models depends on the accuracy of our diagnostic 69 tools. In this research topic, Billig et al.( 6) have proposed a method to perform standardized 70 subxiphoid echocardiography (SE) in swine. The authors have described in detail the specific 71 surgical approach and imaging protocol and also have provided reference values for parameters 72 such as LV stroke volume, ejection fraction, and global longitudinal strain. Standardizing these 73 measurements is essential for ensuring reproducibility across di erent research centers and 74 improving the quality of translational cardiovascular data. 75In conclusion, the six articles presented in this Research Topic reinforce that large animal models 76 remain indispensable to translational medicine. Rather than being replaced by alternative methods, 77 new technologies allow these models to be improved and more closely mimic clinical reality, 78 thereby increasing their translational relevance. By bridging the gap between benchtop innovation 79 and the bedside, these advancements ensure that large animal research remains more essential 80 and rigorous than ever.In summary, this Research Topic highlights the indispensable role of large 81 animals in translating cardiovascular discoveries from the laboratory to the clinic. By refining our 82 models to be more pathomimetic and less stressful for the animals, we improve both the ethical 83 standing and the predictive power of our science. Whether through the development of "o -the-84 shelf" stem cell therapies, the rigorous testing of TAVI devices, or the standardization of imaging 85 protocols, these studies contribute to a more robust framework for cardiovascular innovation. 86We would like to thank all the authors for their innovative submissions and the reviewers for their 87 dedication to ensuring the quality of this Research Topic. We hope this collection serves as a 88 valuable resource for scientists and clinicians working to bridge the gap in cardiovascular therapy. 89 90
- Open Access
- 1 December 2025
- Published by Elsevier in Heart Rhythm O2
- Vol. 7 (2) , 372-377
Local modifications in tissular conditions before PFA increases acute lesion size
- 1 December 2025
- Published by Elsevier in Heart Rhythm O2
- Vol. 7 (2) , 372-377
Open AccessLocal modifications in tissular conditions before PFA increases acute lesion size
- Open Access
- 7 October 2025
- Published by Frontiers Media SA in Frontiers in Cardiovascular Medicine
- Vol. 12, 1668533
Local multifrequency impedance changes after radiofrequency ablation in human atria: potential use for tissue characterization
Background: Local impedance (LI) mapping provides additional tissue characterization of the atria substrate. Measuring LI at different current frequencies has the advantage of exploring intra- and extra-cellular compartments and may add useful information about tissue integrity. The objective of this study was to characterize the changes in local multifrequency impedance (LMI) after radiofrequency ablation in human atrial tissue.Methods: In fifteen patients undergoing catheter ablation of atrial arrhythmias, we constructed a baseline high-density electroanatomical map (EAM) and measured the LMI (1–1,000 kHz) at fifty sites around the cava veins using the QDOT or Smarttouch electrocatheter. Then a point-by-point pulmonary vein isolation procedure was performed using radiofrequency energy in a temperature controlled mode (90W for 4 s for QDOT/30W for 30 s for Smarttouch). After confirming the PVI fifty additional LMI recordings per patient were performed around the initial sites. We performed an offline analysis to compare the values of bipolar voltage and LMI of blood, pre- and post-ablated tissue. We also analyzed the cardiac cycle changes of LMI and the effects of catheter orientation to the LMI, contact force and bipolar voltage.Results: A total of 641 pre-ablated and 190 post-ablated sites were studied from all patients. Blood pool, healthy and post-ablated myocardium presented distinctive LMI signatures (ZPRE = 110 ± 15 Ω vs. ZPOST = 90 ± 10 Ω vs. ZBLOOD = 90 ± 8 Ω; p < 0.001). LMI cyclic changes showed an inverse relationship with the contact force, and these were more attenuated in the post-ablated tissue (p < 0.001).Conclusions: LMI can differentiate pre- from post-ablated tissue in a cohort of patients submitted to RF ablations. This new tool could be of potential clinical applicability for the characterization of the atrial substrate and to monitor lesion quality to perform durable ablation lesions.Clinical Trial Registration: NCT05159180 (https://www.clinicaltrials.gov); Unique Protocol ID: IIBSP-IMS-2021-74.
- 7 October 2025
- Published by Frontiers Media SA in Frontiers in Cardiovascular Medicine
- Vol. 12, 1668533
Open AccessLocal multifrequency impedance changes after radiofrequency ablation in human atria: potential use for tissue characterization
Background: Local impedance (LI) mapping provides additional tissue characterization of the atria substrate. Measuring LI at different current frequencies has the advantage of exploring intra- and extra-cellular compartments and may add useful information about tissue integrity. The objective of this study was to characterize the changes in local multifrequency impedance (LMI) after radiofrequency ablation in human atrial tissue.Methods: In fifteen patients undergoing catheter ablation of atrial arrhythmias, we constructed a baseline high-density electroanatomical map (EAM) and measured the LMI (1–1,000 kHz) at fifty sites around the cava veins using the QDOT or Smarttouch electrocatheter. Then a point-by-point pulmonary vein isolation procedure was performed using radiofrequency energy in a temperature controlled mode (90W for 4 s for QDOT/30W for 30 s for Smarttouch). After confirming the PVI fifty additional LMI recordings per patient were performed around the initial sites. We performed an offline analysis to compare the values of bipolar voltage and LMI of blood, pre- and post-ablated tissue. We also analyzed the cardiac cycle changes of LMI and the effects of catheter orientation to the LMI, contact force and bipolar voltage.Results: A total of 641 pre-ablated and 190 post-ablated sites were studied from all patients. Blood pool, healthy and post-ablated myocardium presented distinctive LMI signatures (ZPRE = 110 ± 15 Ω vs. ZPOST = 90 ± 10 Ω vs. ZBLOOD = 90 ± 8 Ω; p < 0.001). LMI cyclic changes showed an inverse relationship with the contact force, and these were more attenuated in the post-ablated tissue (p < 0.001).Conclusions: LMI can differentiate pre- from post-ablated tissue in a cohort of patients submitted to RF ablations. This new tool could be of potential clinical applicability for the characterization of the atrial substrate and to monitor lesion quality to perform durable ablation lesions.Clinical Trial Registration: NCT05159180 (https://www.clinicaltrials.gov); Unique Protocol ID: IIBSP-IMS-2021-74.
- 27 September 2025
- Published by Elsevier in Heart Rhythm
- Vol. 23 (9) , 2063-2072
Premature ventricular contractions on healthy and diseased hearts: Differential acute effect of coupling interval and location
- 27 September 2025
- Published by Elsevier in Heart Rhythm
- Vol. 23 (9) , 2063-2072
Premature ventricular contractions on healthy and diseased hearts: Differential acute effect of coupling interval and location
- Open Access
- 24 May 2024
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 26 (Supplement)
Real-time characterization of radiofrequency lesions by local multifrequency impedance with thermal correction
Background/Introduction: Recent studies have shown that measuring local impedance (LI) at a single frequency can be useful for real-time characterization of radiofrequency (RF) lesion size during arrhythmia ablation procedures. (1) However, these systems do not take into account the effect of the increase in tissue temperature on the impedance measurement itself, which could be avoided by comparing the impedance at different frequencies. Purpose: The aim of this study was to evaluate the ability of local multifrequency impedance (LMI) to characterize the size of RF lesions in real-time, while correcting for the thermal effect on the measurement. Methods: Lesions were performed on the epicardium in 5 anesthetized pigs while measuring IML (from 1 to 209 kHz) before, during, and after ablations (20W/30W/40W, 60s, >10g) through a conventional irrigated electrocatheter connected to a cardiac navigation system and a RF generator. In these measurements, the thermal effect on the tissue was corrected by assuming that the changes in impedance at high frequency were only due to the temperature variation and not to the injury itself. Local voltage (Vuni) was also measured before and after ablations, and catheter-measured temperature and contact force were monitored. At the end of the procedure, the animals were sacrificed, and a histological study of the lesions was performed. Results: A total of 43 effective lesions (11±2 per animal) were performed. The 40W lesions were deeper and wider than the 20W lesions (6,6 ± 3,3 mm vs. 5,4 ± 2,0 mm vs. 4,0 ± 1,9 mm; ANOVA p<0.05) and presented a significant decrease in unipolar voltage that was similar among the different lesions (40W vs. 20W: 56% vs. 40%; ANOVA p=ns; Figure). Four seconds after the start of the ablation the 40W lesions had a greater decrease in IML than the 30W and 20W lesions (73±14Ω vs. 85±4Ω vs. 100±12Ω; ANOVA p<0.05). After thermal adjustment, IML recorded 30 and 55 seconds after the start of the ablation correlated better with the final depth of the lesion than IL or Vuni (Table). Conclusions: The measure of IML during ablation allows a better quantification of the changes in the structural characteristics of myocardial tissue than local impedance at a single frequency. The increase in tissue temperature during ablation influences the values of local impedance and should be considered when creating new impedance-based metrics to predict the chronic size of the RF lesion.Figure.Lesion quantification by LMITable.Correlation analysis
- 24 May 2024
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 26 (Supplement)
Open AccessReal-time characterization of radiofrequency lesions by local multifrequency impedance with thermal correction
Background/Introduction: Recent studies have shown that measuring local impedance (LI) at a single frequency can be useful for real-time characterization of radiofrequency (RF) lesion size during arrhythmia ablation procedures. (1) However, these systems do not take into account the effect of the increase in tissue temperature on the impedance measurement itself, which could be avoided by comparing the impedance at different frequencies. Purpose: The aim of this study was to evaluate the ability of local multifrequency impedance (LMI) to characterize the size of RF lesions in real-time, while correcting for the thermal effect on the measurement. Methods: Lesions were performed on the epicardium in 5 anesthetized pigs while measuring IML (from 1 to 209 kHz) before, during, and after ablations (20W/30W/40W, 60s, >10g) through a conventional irrigated electrocatheter connected to a cardiac navigation system and a RF generator. In these measurements, the thermal effect on the tissue was corrected by assuming that the changes in impedance at high frequency were only due to the temperature variation and not to the injury itself. Local voltage (Vuni) was also measured before and after ablations, and catheter-measured temperature and contact force were monitored. At the end of the procedure, the animals were sacrificed, and a histological study of the lesions was performed. Results: A total of 43 effective lesions (11±2 per animal) were performed. The 40W lesions were deeper and wider than the 20W lesions (6,6 ± 3,3 mm vs. 5,4 ± 2,0 mm vs. 4,0 ± 1,9 mm; ANOVA p<0.05) and presented a significant decrease in unipolar voltage that was similar among the different lesions (40W vs. 20W: 56% vs. 40%; ANOVA p=ns; Figure). Four seconds after the start of the ablation the 40W lesions had a greater decrease in IML than the 30W and 20W lesions (73±14Ω vs. 85±4Ω vs. 100±12Ω; ANOVA p<0.05). After thermal adjustment, IML recorded 30 and 55 seconds after the start of the ablation correlated better with the final depth of the lesion than IL or Vuni (Table). Conclusions: The measure of IML during ablation allows a better quantification of the changes in the structural characteristics of myocardial tissue than local impedance at a single frequency. The increase in tissue temperature during ablation influences the values of local impedance and should be considered when creating new impedance-based metrics to predict the chronic size of the RF lesion.Figure.Lesion quantification by LMITable.Correlation analysis
- Open Access
- 24 May 2024
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 26 (Supplement)
Changes in local endocardial electrograms immediately after PFA show dose-dependent variations
Background/Introduction: Pulsed field ablation (PFA) is a novel nonthermal cardiac ablation technology based on irreversible electroporation. The behaviour of local electrograms after PFA has been poorly characterized and it remains unknown if it is possible to differentiate between different electroporation levels based on local electrogram analysis. Purpose: The objective of this study was to characterize the alterations in bipolar and unipolar endocardial electrograms after performing PFA at different doses. Methods: Five anesthetized pigs were submitted to PFA treatments. Endovascular access to the right atrium was gained through the femoral vein to create a line of ablation between the superior and inferior vena cava using a focal monopolar catheter. The catheter was switched between a conventional cardiac navigation system (CARTO system) and a custom PFA generator. Two different PFA doses were used: a high dose (HD-1600V) at top and bottom of the line and a low dose (LD-1000V) in the central part of the ablation line. Bipolar and unipolar electrograms were recorded with the ablation catheter before and immediately after each ablation. Additionally, high-density electroanatomical maps were acquired with a multielectrode catheter before and immediately after the procedures. Four weeks later, the animals were remapped again and subsequently euthanized. Atrial tissue was removed and processed to identify the presence of fibrosis in the previously ablated lesions. Results: We performed 106 ablations (84 high dose vs. 22 low dose). Four weeks later, histological staining of chronic lesions revealed that the HD lesions were larger and more fibrotic than the LD (Figure 1). Immediately after each ablation R/S-wave amplitudes and their corresponding |dV/dt|max decreased for the bipolar and unipolar electrograms. The percentages of bipolar electrogram reduction HD vs. LD were: R wave 73% vs. 39%, S wave 68% vs. 37% and |dV/dt|max 81% vs. 38%; 1 way-ANOVA p<0.05 for all, Figure 2). The R-wave amplitude in M1-M2 was significantly lower in HD compared to LD (HD vs. LD: 0.3 ± 0.2 mV vs. 0.7 ± 0.6 mV; 1 way-ANOVA p<0.01). S-wave and |dV/dt|max of unipolar electrograms presented a similar behaviour (M2 |dV/dt|max HD vs. LD: -116 ± 118 mV/s vs. -260 ± 267 mV; 1 way-ANOVA p<0.01). Conclusion: Local electrograms display PFA dose-dependent variations. This information could result useful to create new metrics to assess in real time the performance of PFA systems.Figure 1.EAM maps and histology studyFigure 2.EGM signals and statistics
- 24 May 2024
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 26 (Supplement)
Open AccessChanges in local endocardial electrograms immediately after PFA show dose-dependent variations
Background/Introduction: Pulsed field ablation (PFA) is a novel nonthermal cardiac ablation technology based on irreversible electroporation. The behaviour of local electrograms after PFA has been poorly characterized and it remains unknown if it is possible to differentiate between different electroporation levels based on local electrogram analysis. Purpose: The objective of this study was to characterize the alterations in bipolar and unipolar endocardial electrograms after performing PFA at different doses. Methods: Five anesthetized pigs were submitted to PFA treatments. Endovascular access to the right atrium was gained through the femoral vein to create a line of ablation between the superior and inferior vena cava using a focal monopolar catheter. The catheter was switched between a conventional cardiac navigation system (CARTO system) and a custom PFA generator. Two different PFA doses were used: a high dose (HD-1600V) at top and bottom of the line and a low dose (LD-1000V) in the central part of the ablation line. Bipolar and unipolar electrograms were recorded with the ablation catheter before and immediately after each ablation. Additionally, high-density electroanatomical maps were acquired with a multielectrode catheter before and immediately after the procedures. Four weeks later, the animals were remapped again and subsequently euthanized. Atrial tissue was removed and processed to identify the presence of fibrosis in the previously ablated lesions. Results: We performed 106 ablations (84 high dose vs. 22 low dose). Four weeks later, histological staining of chronic lesions revealed that the HD lesions were larger and more fibrotic than the LD (Figure 1). Immediately after each ablation R/S-wave amplitudes and their corresponding |dV/dt|max decreased for the bipolar and unipolar electrograms. The percentages of bipolar electrogram reduction HD vs. LD were: R wave 73% vs. 39%, S wave 68% vs. 37% and |dV/dt|max 81% vs. 38%; 1 way-ANOVA p<0.05 for all, Figure 2). The R-wave amplitude in M1-M2 was significantly lower in HD compared to LD (HD vs. LD: 0.3 ± 0.2 mV vs. 0.7 ± 0.6 mV; 1 way-ANOVA p<0.01). S-wave and |dV/dt|max of unipolar electrograms presented a similar behaviour (M2 |dV/dt|max HD vs. LD: -116 ± 118 mV/s vs. -260 ± 267 mV; 1 way-ANOVA p<0.01). Conclusion: Local electrograms display PFA dose-dependent variations. This information could result useful to create new metrics to assess in real time the performance of PFA systems.Figure 1.EAM maps and histology studyFigure 2.EGM signals and statistics
- 1 September 2023
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 16 (9) , e011914
Dynamics of High-Density Unipolar Epicardial Electrograms During PFA
BACKGROUND: Pulsed field ablation (PFA) is a novel nonthermal cardiac ablation technology based on irreversible electroporation (IRE). While areas of IRE lead to durable lesions, the surrounding regions, where reversible electroporation occurs, recover. The behavior of local electrograms in areas of different electroporation levels remains unknown. The goal of this study is to characterize electrogram dynamics after PFA in IRE and reversible electroporation areas. METHODS: A total of 6 domestic swine were used. PFA was applied in the epicardium of the right and left ventricles using a focal monopolar catheter. Additional radiofrequency ablations were performed. Epicardial unipolar electrograms were acquired at baseline and for 60 minutes post PFA/radiofrequency ablation using a high-density electrode matrix attached to the epicardium. Electrogram dynamics were analyzed in areas corresponding to different levels of electroporation. Acute lesion formation was assessed after 3 to 5 hours by triphenyl tetrazolium chloride staining. RESULTS: Electrogram analysis demonstrated a clear association between electrogram changes and the level of electroporation. Immediately after PFA, electrograms displayed the following: a significant decrease in R/S-wave amplitude; a large elevation of the ST-segment; and a large decrease in their |(dV/dt)| max . Marked changes in electrograms were observed beyond the lesion area. Thereafter, a gradual recovery was observed. The evolution of all the electrogram parameters throughout the 60 minutes after PFA was significantly different ( P <0.05) between the IRE and reversible electroporation areas. Acute lesion staining showed significantly larger depth for PFA lesions compared with radiofrequency ablation. CONCLUSIONS: This study shows that unipolar electrograms can differentiate between reversible electroporation and IRE areas during the first 30 minutes post ablation. Differences after the first 30 minutes are less evident. Our findings could result useful for immediate lesion assessment after PFA and warrant further investigation.
- 1 September 2023
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 16 (9) , e011914
Dynamics of High-Density Unipolar Epicardial Electrograms During PFA
BACKGROUND: Pulsed field ablation (PFA) is a novel nonthermal cardiac ablation technology based on irreversible electroporation (IRE). While areas of IRE lead to durable lesions, the surrounding regions, where reversible electroporation occurs, recover. The behavior of local electrograms in areas of different electroporation levels remains unknown. The goal of this study is to characterize electrogram dynamics after PFA in IRE and reversible electroporation areas. METHODS: A total of 6 domestic swine were used. PFA was applied in the epicardium of the right and left ventricles using a focal monopolar catheter. Additional radiofrequency ablations were performed. Epicardial unipolar electrograms were acquired at baseline and for 60 minutes post PFA/radiofrequency ablation using a high-density electrode matrix attached to the epicardium. Electrogram dynamics were analyzed in areas corresponding to different levels of electroporation. Acute lesion formation was assessed after 3 to 5 hours by triphenyl tetrazolium chloride staining. RESULTS: Electrogram analysis demonstrated a clear association between electrogram changes and the level of electroporation. Immediately after PFA, electrograms displayed the following: a significant decrease in R/S-wave amplitude; a large elevation of the ST-segment; and a large decrease in their |(dV/dt)| max . Marked changes in electrograms were observed beyond the lesion area. Thereafter, a gradual recovery was observed. The evolution of all the electrogram parameters throughout the 60 minutes after PFA was significantly different ( P <0.05) between the IRE and reversible electroporation areas. Acute lesion staining showed significantly larger depth for PFA lesions compared with radiofrequency ablation. CONCLUSIONS: This study shows that unipolar electrograms can differentiate between reversible electroporation and IRE areas during the first 30 minutes post ablation. Differences after the first 30 minutes are less evident. Our findings could result useful for immediate lesion assessment after PFA and warrant further investigation.
- Open Access
- 12 January 2023
- Published by Frontiers Media SA in Frontiers in Physiology
- Vol. 13, 1104327
Electrophysiological and histological characterization of atrial scarring in a model of isolated atrial myocardial infarction
Background: Characterization of atrial myocardial infarction is hampered by the frequent concurrence of ventricular infarction. Theoretically, atrial infarct scarring could be recognized by multifrequency tissue impedance, like in ventricular infarction, but this remains to be proven.Objective: This study aimed at developing a model of atrial infarction to assess the potential of multifrequency impedance to recognize areas of atrial infarct scar. Methods: Seven anesthetized pigs were submitted to transcatheter occlusion of atrial coronary branches arising from the left coronary circumflex artery. Six weeks later the animals were anesthetized and underwent atrial voltage mapping and multifrequency impedance recordings. The hearts were thereafter extracted for anatomopathological study. Two additional pigs not submitted to atrial branch occlusion were used as controls.Results: Selective occlusion of the atrial branches induced areas of healed infarction in the left atrium in 6 of the 7 cases. Endocardial mapping of the left atrium showed reduced multi-frequency impedance (Phase angle at 307 kHz: from −17.1° ± 5.0° to −8.9° ± 2.6°, p < .01) and low-voltage of bipolar electrograms (.2 ± 0.1 mV vs. 1.9 ± 1.5 mV vs., p < .01) in areas affected by the infarction. Data variability of the impedance phase angle was lower than that of bipolar voltage (coefficient of variability of phase angle at307 kHz vs. bipolar voltage: .30 vs. .77). Histological analysis excluded the presence of ventricular infarction.Conclusion: Selective occlusion of atrial coronary branches permits to set up a model of selective atrial infarction. Atrial multifrequency impedance mapping allowed recognition of atrial infarct scarring with lesser data variability than local bipolar voltage mapping. Our model may have potential applicability on the study of atrial arrhythmia mechanisms.
- 12 January 2023
- Published by Frontiers Media SA in Frontiers in Physiology
- Vol. 13, 1104327
Open AccessElectrophysiological and histological characterization of atrial scarring in a model of isolated atrial myocardial infarction
Background: Characterization of atrial myocardial infarction is hampered by the frequent concurrence of ventricular infarction. Theoretically, atrial infarct scarring could be recognized by multifrequency tissue impedance, like in ventricular infarction, but this remains to be proven.Objective: This study aimed at developing a model of atrial infarction to assess the potential of multifrequency impedance to recognize areas of atrial infarct scar. Methods: Seven anesthetized pigs were submitted to transcatheter occlusion of atrial coronary branches arising from the left coronary circumflex artery. Six weeks later the animals were anesthetized and underwent atrial voltage mapping and multifrequency impedance recordings. The hearts were thereafter extracted for anatomopathological study. Two additional pigs not submitted to atrial branch occlusion were used as controls.Results: Selective occlusion of the atrial branches induced areas of healed infarction in the left atrium in 6 of the 7 cases. Endocardial mapping of the left atrium showed reduced multi-frequency impedance (Phase angle at 307 kHz: from −17.1° ± 5.0° to −8.9° ± 2.6°, p < .01) and low-voltage of bipolar electrograms (.2 ± 0.1 mV vs. 1.9 ± 1.5 mV vs., p < .01) in areas affected by the infarction. Data variability of the impedance phase angle was lower than that of bipolar voltage (coefficient of variability of phase angle at307 kHz vs. bipolar voltage: .30 vs. .77). Histological analysis excluded the presence of ventricular infarction.Conclusion: Selective occlusion of atrial coronary branches permits to set up a model of selective atrial infarction. Atrial multifrequency impedance mapping allowed recognition of atrial infarct scarring with lesser data variability than local bipolar voltage mapping. Our model may have potential applicability on the study of atrial arrhythmia mechanisms.
- 1 October 2022
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 15 (10) , e010992
Parametric Study of Pulsed Field Ablation With Biphasic Waveforms in an In Vivo Heart Model: The Role of Frequency
Background: Pulsed field ablation (PFA) is a novel nonthermal cardiac ablation technology based on irreversible electroporation. Unfortunately, the characteristics of the electric field waveforms used in clinical and experimental PFA are not typically reported. This study examines the effect of the frequency of biphasic waveforms and compares biphasic to monophasic waveforms. Methods: A total of 29 Sprague-Dawley rats were treated with PFA using an epicardial monopolar electrode. Biphasic waveforms with three different frequencies, 90, 260, and 450 kHz (10 bursts of 100 µs duration at 500 V or 800 V) and monophasic waveforms (10 pulses of 100 µs duration at 500 V) were studied. Collateral neuromuscular stimulation and temperature increase in the point of application were directly measured. Lesion formation was assessed 3 weeks after treatment by histopathologic analysis. Computer simulations were used to estimate the electric field lethal threshold for each condition. A previous in vitro study was performed to draw a complete characterization of the studied dependencies. Results: Morphometric analysis demonstrated a significant association between chronic lesion size and waveform characteristics. For the same voltage level, monophasic waveforms yielded the largest lesions compared with any of the biphasic protocols ( P <0.05). Increasing PFA frequency was associated with reduced neuromuscular stimulation but also with reduced ablation efficacy. Maximum absolute temperature increase recorded along a complete treatment was 3 °C. Vascular structures inside the lesions were preserved for all conditions. Computer simulation-based analysis showed that waveform frequency had a graded effect on the lethal electric field threshold, with threshold of 600 V/cm for monophasic waveforms versus 2000 V/cm for biphasic waveforms with a frequency of 450 kHz. Conclusions: Frequency is a major determinant of efficacy in biphasic PFA. Our results highlight the critical need of disclosing waveform characteristics when reporting the results of different PFA systems.
- 1 October 2022
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 15 (10) , e010992
Parametric Study of Pulsed Field Ablation With Biphasic Waveforms in an In Vivo Heart Model: The Role of Frequency
Background: Pulsed field ablation (PFA) is a novel nonthermal cardiac ablation technology based on irreversible electroporation. Unfortunately, the characteristics of the electric field waveforms used in clinical and experimental PFA are not typically reported. This study examines the effect of the frequency of biphasic waveforms and compares biphasic to monophasic waveforms. Methods: A total of 29 Sprague-Dawley rats were treated with PFA using an epicardial monopolar electrode. Biphasic waveforms with three different frequencies, 90, 260, and 450 kHz (10 bursts of 100 µs duration at 500 V or 800 V) and monophasic waveforms (10 pulses of 100 µs duration at 500 V) were studied. Collateral neuromuscular stimulation and temperature increase in the point of application were directly measured. Lesion formation was assessed 3 weeks after treatment by histopathologic analysis. Computer simulations were used to estimate the electric field lethal threshold for each condition. A previous in vitro study was performed to draw a complete characterization of the studied dependencies. Results: Morphometric analysis demonstrated a significant association between chronic lesion size and waveform characteristics. For the same voltage level, monophasic waveforms yielded the largest lesions compared with any of the biphasic protocols ( P <0.05). Increasing PFA frequency was associated with reduced neuromuscular stimulation but also with reduced ablation efficacy. Maximum absolute temperature increase recorded along a complete treatment was 3 °C. Vascular structures inside the lesions were preserved for all conditions. Computer simulation-based analysis showed that waveform frequency had a graded effect on the lethal electric field threshold, with threshold of 600 V/cm for monophasic waveforms versus 2000 V/cm for biphasic waveforms with a frequency of 450 kHz. Conclusions: Frequency is a major determinant of efficacy in biphasic PFA. Our results highlight the critical need of disclosing waveform characteristics when reporting the results of different PFA systems.
- Open Access
- 12 February 2019
- Published by Frontiers Media SA in Frontiers in Physiology
- Vol. 10, 82
Influence of Left Bundle Branch Block on the Electrocardiographic Changes Induced by Acute Coronary Artery Occlusion of Distinct Location and Duration
Background: Electrocardiographic (ECG) diagnosis of acute myocardial ischemia is hampered in the presence of left bundle branch block (LBBB). Objectives: We analyzed the influence of location and duration of myocardial ischemia on the ECG changes in pigs with LBBB. Methods: LBBB was acutely induced in 14 closed chest anesthetized pigs by local electrical ablation. Thereafter, episodes of 5 min catheter balloon occlusion followed by 10 min reperfusion of the left anterior descending (LAD), left circumflex (LCX), and right (RCA) coronary arteries were done sequentially in 5 pigs. Additionally, a 3-h occlusion of these arteries was performed separately in the other 9 pigs. A 15-lead ECG including leads V7 to V9 was continuously recorded. Results: Ablation induced LBBB showed QRS widening, loss of r wave in V1, and predominant R waves in V2 to V9. After 5 min of ischemia the occluded artery could be identified in all cases: the LAD by R waves and ST elevation in V1–V3; the LCX by both ST segment elevation in II, III, aVF, V7 to V9 and ST segment depression in V1 to V4; and the RCA by ST depression and new S-waves in all precordial leads. Three hours after coronary occlusion, ST segment changes declined progressively and only the LAD occlusion could be reliably recognized. Conclusion: LBBB did not mask the ECG recognition of the occluded coronary artery during the first 60 min of ischemia, but 3 h later only the LAD occlusion could be reliably identified. ST elevation in leads V7 to V9 is specific of LCX occlusion and it could be useful in the diagnosis of acute myocardial ischemia in the presence of LBBB.
- 12 February 2019
- Published by Frontiers Media SA in Frontiers in Physiology
- Vol. 10, 82
Open AccessInfluence of Left Bundle Branch Block on the Electrocardiographic Changes Induced by Acute Coronary Artery Occlusion of Distinct Location and Duration
Background: Electrocardiographic (ECG) diagnosis of acute myocardial ischemia is hampered in the presence of left bundle branch block (LBBB). Objectives: We analyzed the influence of location and duration of myocardial ischemia on the ECG changes in pigs with LBBB. Methods: LBBB was acutely induced in 14 closed chest anesthetized pigs by local electrical ablation. Thereafter, episodes of 5 min catheter balloon occlusion followed by 10 min reperfusion of the left anterior descending (LAD), left circumflex (LCX), and right (RCA) coronary arteries were done sequentially in 5 pigs. Additionally, a 3-h occlusion of these arteries was performed separately in the other 9 pigs. A 15-lead ECG including leads V7 to V9 was continuously recorded. Results: Ablation induced LBBB showed QRS widening, loss of r wave in V1, and predominant R waves in V2 to V9. After 5 min of ischemia the occluded artery could be identified in all cases: the LAD by R waves and ST elevation in V1–V3; the LCX by both ST segment elevation in II, III, aVF, V7 to V9 and ST segment depression in V1 to V4; and the RCA by ST depression and new S-waves in all precordial leads. Three hours after coronary occlusion, ST segment changes declined progressively and only the LAD occlusion could be reliably recognized. Conclusion: LBBB did not mask the ECG recognition of the occluded coronary artery during the first 60 min of ischemia, but 3 h later only the LAD occlusion could be reliably identified. ST elevation in leads V7 to V9 is specific of LCX occlusion and it could be useful in the diagnosis of acute myocardial ischemia in the presence of LBBB.