Tomás García-Sánchez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Tomás García-Sánchez has a total of 116 co-authors. Here are the top co-authors by number of shared publications:
Lluis M. Mir
Université Paris-Saclay, Institut Gustave Roussy, CNRS, Metabolic and Systemic Aspects of Oncogenesis (METSY), 94805 Villejuif, France
9 shared publications- Javier Rosell-Ferrer
Department of Electronic Engineering, Universitat Politècnica de Catalunya, Barcelona, Spain
8 shared publications - Gerard Amorós-Figueras
Department of Cardiology, Hospital de la Santa Creu I Sant Pau, Institut de Recerca Sant Pau (IR Sant Pau), CIBERCV, Universitat Autònoma de Barcelona
6 shared publications Antoine Azan
Vectorology and Anticancer Therapies, UMR 8203, CNRS, Gustave Roussy, Univ. Paris-Sud, Université Paris-Saclay, Villejuif, France
5 shared publicationsIsabelle Leray
Vectorology and Anticancer Therapies, UMR 8203, CNRS, Univ. Paris-Sud, Gustave Roussy, Université Paris-Saclay, 94805 Villejuif, France
5 shared publications- Antoni Ivorra
Universitat Pompeu Fabra, Barcelona, Spain
4 shared publications
Latest Publications
- Open Access
- 21 October 2026
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 28 (Supplement) , ii128-ii142
The future of PFA in cardiac ablation procedures
Pulsed field ablation (PFA) has rapidly emerged as a major development in catheter ablation, with increasing clinical adoption driven by procedural efficiency and a favorable safety profile compared with thermal energies. This article summarizes the future directions of PFA in electrophysiology, focusing on technological innovation, and how these advances are expected to expand PFA clinical indications. Additionally, this article provides a perspective on current gaps and future challenges of PFA. A perspective on future developments in new waveforms, catheter architectures, and integration with electroanatomical mapping systems for PFA is summarized. The document discusses novel waveform configurations and catheter design concepts that may improve lesion quality, procedural versatility, and safety. Additionally, this article also reviews how parallel advances in electroanatomical mapping integration, artificial intelligence, and robotic navigation are expected to enhance procedural guidance and enable individualized therapy. This manuscript summarizes the potential applications of PFA beyond pulmonary vein isolation and how emerging evidence supports its feasibility for linear atrial lesions, substrate modification, treatment of complex atrial tachycardias, and ventricular arrhythmia ablation. In addition, this article provides insights on how PFA may facilitate catheter ablation in new patient populations including elderly patients and those with higher procedural risks. Finally, this manuscript provides an outlook at major remaining challenges and knowledge gaps for PFA. The lack of homogenous procedural endpoints definitions and lesion durability assessment are discussed. Furthermore, this article highlights the need for standardized terminology and reporting in an environment where the high heterogeneity between available commercial systems complicates comparison across technologies.
- 21 October 2026
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 28 (Supplement) , ii128-ii142
Open AccessThe future of PFA in cardiac ablation procedures
Pulsed field ablation (PFA) has rapidly emerged as a major development in catheter ablation, with increasing clinical adoption driven by procedural efficiency and a favorable safety profile compared with thermal energies. This article summarizes the future directions of PFA in electrophysiology, focusing on technological innovation, and how these advances are expected to expand PFA clinical indications. Additionally, this article provides a perspective on current gaps and future challenges of PFA. A perspective on future developments in new waveforms, catheter architectures, and integration with electroanatomical mapping systems for PFA is summarized. The document discusses novel waveform configurations and catheter design concepts that may improve lesion quality, procedural versatility, and safety. Additionally, this article also reviews how parallel advances in electroanatomical mapping integration, artificial intelligence, and robotic navigation are expected to enhance procedural guidance and enable individualized therapy. This manuscript summarizes the potential applications of PFA beyond pulmonary vein isolation and how emerging evidence supports its feasibility for linear atrial lesions, substrate modification, treatment of complex atrial tachycardias, and ventricular arrhythmia ablation. In addition, this article provides insights on how PFA may facilitate catheter ablation in new patient populations including elderly patients and those with higher procedural risks. Finally, this manuscript provides an outlook at major remaining challenges and knowledge gaps for PFA. The lack of homogenous procedural endpoints definitions and lesion durability assessment are discussed. Furthermore, this article highlights the need for standardized terminology and reporting in an environment where the high heterogeneity between available commercial systems complicates comparison across technologies.
- Open Access
- 21 October 2026
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 28 (Supplement) , ii32-ii51
Specific effects of Pulsed Field Ablation on the cardiac tissue, the nervous system and the conduction system in experimental and clinical studies
Aims: Pulsed field ablation (PFA) has emerged as a novel ablation modality for the treatment of cardiac arrhythmias and has rapidly reshaped contemporary electrophysiology practice. This article provides a comprehensive analysis on the mechanisms underlying the specific effects of PFA on myocardial, neural tissue structures, and the cardiac conduction system, integrating biophysical principles with preclinical and clinical evidence relevant to contemporary electrophysiology practice. Methods and results: This document provides an exhaustive mechanistic explanation for the preferential effects of PFA on myocardium and the limits of the ‘tissue-selectivity’ concept. The complex interplay between cellular and tissue-level biophysics, biological responses, and tissue regenerative capacity that determines differential susceptibility to electroporation across tissues is analysed. Distinct patterns of lesion formation and maturation following PFA are also reviewed, highlighting the temporal and histopathological differences compared with radiofrequency ablation. Additionally, lesion formation in heterogeneous substrates is analysed, including fibrotic and adipose-rich myocardium, where local electric field distribution critically influences lesion durability. Conclusion: The article further examines the interaction between pulsed electric fields and neural tissue, with emphasis on the phrenic nerve and intrinsic cardiac autonomic nervous system. While nerve stimulation and transient reversible conduction disturbances produced by reversible electroporation can occur during ablation, permanent neural injury appears extremely rare in current clinical experience. Finally, this manuscript examines current understanding regarding the specific effects of PFA on the cardiac conduction system, which according to the limited available evidence appear strongly dependent on electric field dose and anatomical proximity.
- 21 October 2026
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 28 (Supplement) , ii32-ii51
Open AccessSpecific effects of Pulsed Field Ablation on the cardiac tissue, the nervous system and the conduction system in experimental and clinical studies
Aims: Pulsed field ablation (PFA) has emerged as a novel ablation modality for the treatment of cardiac arrhythmias and has rapidly reshaped contemporary electrophysiology practice. This article provides a comprehensive analysis on the mechanisms underlying the specific effects of PFA on myocardial, neural tissue structures, and the cardiac conduction system, integrating biophysical principles with preclinical and clinical evidence relevant to contemporary electrophysiology practice. Methods and results: This document provides an exhaustive mechanistic explanation for the preferential effects of PFA on myocardium and the limits of the ‘tissue-selectivity’ concept. The complex interplay between cellular and tissue-level biophysics, biological responses, and tissue regenerative capacity that determines differential susceptibility to electroporation across tissues is analysed. Distinct patterns of lesion formation and maturation following PFA are also reviewed, highlighting the temporal and histopathological differences compared with radiofrequency ablation. Additionally, lesion formation in heterogeneous substrates is analysed, including fibrotic and adipose-rich myocardium, where local electric field distribution critically influences lesion durability. Conclusion: The article further examines the interaction between pulsed electric fields and neural tissue, with emphasis on the phrenic nerve and intrinsic cardiac autonomic nervous system. While nerve stimulation and transient reversible conduction disturbances produced by reversible electroporation can occur during ablation, permanent neural injury appears extremely rare in current clinical experience. Finally, this manuscript examines current understanding regarding the specific effects of PFA on the cardiac conduction system, which according to the limited available evidence appear strongly dependent on electric field dose and anatomical proximity.
- Open Access
- 21 October 2026
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 28 (Supplement) , ii1-ii2
Foreword: An educational reference for pulsed field ablation
- 21 October 2026
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 28 (Supplement) , ii1-ii2
Open AccessForeword: An educational reference for pulsed field ablation
- Open Access
- 8 August 2024
- Published by MDPI AG in Biosensors
- Vol. 14 (8) , 382
Electrical Conductivity Measurement in Human Liver Tissue: Assessment on Normal vs. Tumor Tissue and under In Vivo vs. Ex Vivo Conditions
Background: This study evaluated electrical conductivity in human liver tissue in the 3–1000 kHz frequency range to compare normal versus tumor tissues under in vivo versus ex vivo conditions. Methods: Previous informed consent was obtained from twenty patients undergoing liver resection in whom liver electrical conductivity was measured during surgery and after resection. Result: We found higher electrical conductivity values in tumor tissues than in normal tissue in both in vivo (0.41 ± 0.10 vs. 0.13 ± 0.06 S/m) and ex vivo (0.27 ± 0.09 vs. 0.12 ± 0.07 S/m) conditions (at 3 kHz). The electric properties also showed a promising potential for distinguishing between different tissue types including metastasis, cholangiocarcinoma (CCA), hepatocellular carcinoma (HCC), hepatic cirrhosis, and normal liver (both in vivo and ex vivo). At 3 kHz, in vivo electrical conductivity for cholangiocarcinoma, HCC, and metastasis were 0.35, 0.42 ± 0.13, and 0.41 ± 0.08 S/m, respectively, which differed significantly from each other (p < 0.05). Conclusions: These findings could potentially improve liver disease diagnostics through electrical conductivity measurements and treatment techniques involving electric fields. Future research should focus on expanding the sample size to refine the categorization and comparison processes across diverse human liver tissue types.
- 8 August 2024
- Published by MDPI AG in Biosensors
- Vol. 14 (8) , 382
Open AccessElectrical Conductivity Measurement in Human Liver Tissue: Assessment on Normal vs. Tumor Tissue and under In Vivo vs. Ex Vivo Conditions
Background: This study evaluated electrical conductivity in human liver tissue in the 3–1000 kHz frequency range to compare normal versus tumor tissues under in vivo versus ex vivo conditions. Methods: Previous informed consent was obtained from twenty patients undergoing liver resection in whom liver electrical conductivity was measured during surgery and after resection. Result: We found higher electrical conductivity values in tumor tissues than in normal tissue in both in vivo (0.41 ± 0.10 vs. 0.13 ± 0.06 S/m) and ex vivo (0.27 ± 0.09 vs. 0.12 ± 0.07 S/m) conditions (at 3 kHz). The electric properties also showed a promising potential for distinguishing between different tissue types including metastasis, cholangiocarcinoma (CCA), hepatocellular carcinoma (HCC), hepatic cirrhosis, and normal liver (both in vivo and ex vivo). At 3 kHz, in vivo electrical conductivity for cholangiocarcinoma, HCC, and metastasis were 0.35, 0.42 ± 0.13, and 0.41 ± 0.08 S/m, respectively, which differed significantly from each other (p < 0.05). Conclusions: These findings could potentially improve liver disease diagnostics through electrical conductivity measurements and treatment techniques involving electric fields. Future research should focus on expanding the sample size to refine the categorization and comparison processes across diverse human liver tissue types.
- Open Access
- 24 May 2024
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 26 (Supplement)
Changes in local endocardial electrograms immediately after PFA show dose-dependent variations
Background/Introduction: Pulsed field ablation (PFA) is a novel nonthermal cardiac ablation technology based on irreversible electroporation. The behaviour of local electrograms after PFA has been poorly characterized and it remains unknown if it is possible to differentiate between different electroporation levels based on local electrogram analysis. Purpose: The objective of this study was to characterize the alterations in bipolar and unipolar endocardial electrograms after performing PFA at different doses. Methods: Five anesthetized pigs were submitted to PFA treatments. Endovascular access to the right atrium was gained through the femoral vein to create a line of ablation between the superior and inferior vena cava using a focal monopolar catheter. The catheter was switched between a conventional cardiac navigation system (CARTO system) and a custom PFA generator. Two different PFA doses were used: a high dose (HD-1600V) at top and bottom of the line and a low dose (LD-1000V) in the central part of the ablation line. Bipolar and unipolar electrograms were recorded with the ablation catheter before and immediately after each ablation. Additionally, high-density electroanatomical maps were acquired with a multielectrode catheter before and immediately after the procedures. Four weeks later, the animals were remapped again and subsequently euthanized. Atrial tissue was removed and processed to identify the presence of fibrosis in the previously ablated lesions. Results: We performed 106 ablations (84 high dose vs. 22 low dose). Four weeks later, histological staining of chronic lesions revealed that the HD lesions were larger and more fibrotic than the LD (Figure 1). Immediately after each ablation R/S-wave amplitudes and their corresponding |dV/dt|max decreased for the bipolar and unipolar electrograms. The percentages of bipolar electrogram reduction HD vs. LD were: R wave 73% vs. 39%, S wave 68% vs. 37% and |dV/dt|max 81% vs. 38%; 1 way-ANOVA p<0.05 for all, Figure 2). The R-wave amplitude in M1-M2 was significantly lower in HD compared to LD (HD vs. LD: 0.3 ± 0.2 mV vs. 0.7 ± 0.6 mV; 1 way-ANOVA p<0.01). S-wave and |dV/dt|max of unipolar electrograms presented a similar behaviour (M2 |dV/dt|max HD vs. LD: -116 ± 118 mV/s vs. -260 ± 267 mV; 1 way-ANOVA p<0.01). Conclusion: Local electrograms display PFA dose-dependent variations. This information could result useful to create new metrics to assess in real time the performance of PFA systems.Figure 1.EAM maps and histology studyFigure 2.EGM signals and statistics
- 24 May 2024
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 26 (Supplement)
Open AccessChanges in local endocardial electrograms immediately after PFA show dose-dependent variations
Background/Introduction: Pulsed field ablation (PFA) is a novel nonthermal cardiac ablation technology based on irreversible electroporation. The behaviour of local electrograms after PFA has been poorly characterized and it remains unknown if it is possible to differentiate between different electroporation levels based on local electrogram analysis. Purpose: The objective of this study was to characterize the alterations in bipolar and unipolar endocardial electrograms after performing PFA at different doses. Methods: Five anesthetized pigs were submitted to PFA treatments. Endovascular access to the right atrium was gained through the femoral vein to create a line of ablation between the superior and inferior vena cava using a focal monopolar catheter. The catheter was switched between a conventional cardiac navigation system (CARTO system) and a custom PFA generator. Two different PFA doses were used: a high dose (HD-1600V) at top and bottom of the line and a low dose (LD-1000V) in the central part of the ablation line. Bipolar and unipolar electrograms were recorded with the ablation catheter before and immediately after each ablation. Additionally, high-density electroanatomical maps were acquired with a multielectrode catheter before and immediately after the procedures. Four weeks later, the animals were remapped again and subsequently euthanized. Atrial tissue was removed and processed to identify the presence of fibrosis in the previously ablated lesions. Results: We performed 106 ablations (84 high dose vs. 22 low dose). Four weeks later, histological staining of chronic lesions revealed that the HD lesions were larger and more fibrotic than the LD (Figure 1). Immediately after each ablation R/S-wave amplitudes and their corresponding |dV/dt|max decreased for the bipolar and unipolar electrograms. The percentages of bipolar electrogram reduction HD vs. LD were: R wave 73% vs. 39%, S wave 68% vs. 37% and |dV/dt|max 81% vs. 38%; 1 way-ANOVA p<0.05 for all, Figure 2). The R-wave amplitude in M1-M2 was significantly lower in HD compared to LD (HD vs. LD: 0.3 ± 0.2 mV vs. 0.7 ± 0.6 mV; 1 way-ANOVA p<0.01). S-wave and |dV/dt|max of unipolar electrograms presented a similar behaviour (M2 |dV/dt|max HD vs. LD: -116 ± 118 mV/s vs. -260 ± 267 mV; 1 way-ANOVA p<0.01). Conclusion: Local electrograms display PFA dose-dependent variations. This information could result useful to create new metrics to assess in real time the performance of PFA systems.Figure 1.EAM maps and histology studyFigure 2.EGM signals and statistics
- Open Access
- 26 October 2023
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 24 (21) , 15616
In Vitro Imaging and Molecular Characterization of Ca2+ Flux Modulation by Nanosecond Pulsed Electric Fields
In recent years, the application of pulsed electric fields with very short durations (nanoseconds) and extremely high amplitudes (MV/m) has been investigated for novel medical purposes. Various electric protocols have been explored for different objectives, including the utilization of fractionated pulse doses to enhance cell electrosensitization to the uptake of different markers or an increase in apoptosis. This study focused on the use of fluorescence imaging to examine molecular calcium fluxes induced by different fractionated protocols of short electric pulses in neuroblastoma (SH-SY5Y) and mesenchymal stem cells (HaMSCs) that were electroporated using nanosecond pulsed electric fields. In our experimental setup, we did not observe cell electrosensitization in terms of an increase in calcium flux following the administration of fractionated doses of nanosecond pulsed electric fields with respect to the non-fractionated dose. However, we observed the targeted activation of calcium-dependent genes (c-FOS, c-JUN, EGR1, NURR-1, β3-TUBULIN) based on the duration of calcium flux, independent of the instantaneous levels achieved but solely dependent on the final plateau reached. This level of control may have potential applications in various medical and biological treatments that rely on calcium and the delivery of nanosecond pulsed electric fields.
- 26 October 2023
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 24 (21) , 15616
Open AccessIn Vitro Imaging and Molecular Characterization of Ca2+ Flux Modulation by Nanosecond Pulsed Electric Fields
In recent years, the application of pulsed electric fields with very short durations (nanoseconds) and extremely high amplitudes (MV/m) has been investigated for novel medical purposes. Various electric protocols have been explored for different objectives, including the utilization of fractionated pulse doses to enhance cell electrosensitization to the uptake of different markers or an increase in apoptosis. This study focused on the use of fluorescence imaging to examine molecular calcium fluxes induced by different fractionated protocols of short electric pulses in neuroblastoma (SH-SY5Y) and mesenchymal stem cells (HaMSCs) that were electroporated using nanosecond pulsed electric fields. In our experimental setup, we did not observe cell electrosensitization in terms of an increase in calcium flux following the administration of fractionated doses of nanosecond pulsed electric fields with respect to the non-fractionated dose. However, we observed the targeted activation of calcium-dependent genes (c-FOS, c-JUN, EGR1, NURR-1, β3-TUBULIN) based on the duration of calcium flux, independent of the instantaneous levels achieved but solely dependent on the final plateau reached. This level of control may have potential applications in various medical and biological treatments that rely on calcium and the delivery of nanosecond pulsed electric fields.
- 1 September 2023
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 16 (9) , e011914
Dynamics of High-Density Unipolar Epicardial Electrograms During PFA
BACKGROUND: Pulsed field ablation (PFA) is a novel nonthermal cardiac ablation technology based on irreversible electroporation (IRE). While areas of IRE lead to durable lesions, the surrounding regions, where reversible electroporation occurs, recover. The behavior of local electrograms in areas of different electroporation levels remains unknown. The goal of this study is to characterize electrogram dynamics after PFA in IRE and reversible electroporation areas. METHODS: A total of 6 domestic swine were used. PFA was applied in the epicardium of the right and left ventricles using a focal monopolar catheter. Additional radiofrequency ablations were performed. Epicardial unipolar electrograms were acquired at baseline and for 60 minutes post PFA/radiofrequency ablation using a high-density electrode matrix attached to the epicardium. Electrogram dynamics were analyzed in areas corresponding to different levels of electroporation. Acute lesion formation was assessed after 3 to 5 hours by triphenyl tetrazolium chloride staining. RESULTS: Electrogram analysis demonstrated a clear association between electrogram changes and the level of electroporation. Immediately after PFA, electrograms displayed the following: a significant decrease in R/S-wave amplitude; a large elevation of the ST-segment; and a large decrease in their |(dV/dt)| max . Marked changes in electrograms were observed beyond the lesion area. Thereafter, a gradual recovery was observed. The evolution of all the electrogram parameters throughout the 60 minutes after PFA was significantly different ( P <0.05) between the IRE and reversible electroporation areas. Acute lesion staining showed significantly larger depth for PFA lesions compared with radiofrequency ablation. CONCLUSIONS: This study shows that unipolar electrograms can differentiate between reversible electroporation and IRE areas during the first 30 minutes post ablation. Differences after the first 30 minutes are less evident. Our findings could result useful for immediate lesion assessment after PFA and warrant further investigation.
- 1 September 2023
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 16 (9) , e011914
Dynamics of High-Density Unipolar Epicardial Electrograms During PFA
BACKGROUND: Pulsed field ablation (PFA) is a novel nonthermal cardiac ablation technology based on irreversible electroporation (IRE). While areas of IRE lead to durable lesions, the surrounding regions, where reversible electroporation occurs, recover. The behavior of local electrograms in areas of different electroporation levels remains unknown. The goal of this study is to characterize electrogram dynamics after PFA in IRE and reversible electroporation areas. METHODS: A total of 6 domestic swine were used. PFA was applied in the epicardium of the right and left ventricles using a focal monopolar catheter. Additional radiofrequency ablations were performed. Epicardial unipolar electrograms were acquired at baseline and for 60 minutes post PFA/radiofrequency ablation using a high-density electrode matrix attached to the epicardium. Electrogram dynamics were analyzed in areas corresponding to different levels of electroporation. Acute lesion formation was assessed after 3 to 5 hours by triphenyl tetrazolium chloride staining. RESULTS: Electrogram analysis demonstrated a clear association between electrogram changes and the level of electroporation. Immediately after PFA, electrograms displayed the following: a significant decrease in R/S-wave amplitude; a large elevation of the ST-segment; and a large decrease in their |(dV/dt)| max . Marked changes in electrograms were observed beyond the lesion area. Thereafter, a gradual recovery was observed. The evolution of all the electrogram parameters throughout the 60 minutes after PFA was significantly different ( P <0.05) between the IRE and reversible electroporation areas. Acute lesion staining showed significantly larger depth for PFA lesions compared with radiofrequency ablation. CONCLUSIONS: This study shows that unipolar electrograms can differentiate between reversible electroporation and IRE areas during the first 30 minutes post ablation. Differences after the first 30 minutes are less evident. Our findings could result useful for immediate lesion assessment after PFA and warrant further investigation.
- 1 October 2022
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 15 (10) , e010992
Parametric Study of Pulsed Field Ablation With Biphasic Waveforms in an In Vivo Heart Model: The Role of Frequency
Background: Pulsed field ablation (PFA) is a novel nonthermal cardiac ablation technology based on irreversible electroporation. Unfortunately, the characteristics of the electric field waveforms used in clinical and experimental PFA are not typically reported. This study examines the effect of the frequency of biphasic waveforms and compares biphasic to monophasic waveforms. Methods: A total of 29 Sprague-Dawley rats were treated with PFA using an epicardial monopolar electrode. Biphasic waveforms with three different frequencies, 90, 260, and 450 kHz (10 bursts of 100 µs duration at 500 V or 800 V) and monophasic waveforms (10 pulses of 100 µs duration at 500 V) were studied. Collateral neuromuscular stimulation and temperature increase in the point of application were directly measured. Lesion formation was assessed 3 weeks after treatment by histopathologic analysis. Computer simulations were used to estimate the electric field lethal threshold for each condition. A previous in vitro study was performed to draw a complete characterization of the studied dependencies. Results: Morphometric analysis demonstrated a significant association between chronic lesion size and waveform characteristics. For the same voltage level, monophasic waveforms yielded the largest lesions compared with any of the biphasic protocols ( P <0.05). Increasing PFA frequency was associated with reduced neuromuscular stimulation but also with reduced ablation efficacy. Maximum absolute temperature increase recorded along a complete treatment was 3 °C. Vascular structures inside the lesions were preserved for all conditions. Computer simulation-based analysis showed that waveform frequency had a graded effect on the lethal electric field threshold, with threshold of 600 V/cm for monophasic waveforms versus 2000 V/cm for biphasic waveforms with a frequency of 450 kHz. Conclusions: Frequency is a major determinant of efficacy in biphasic PFA. Our results highlight the critical need of disclosing waveform characteristics when reporting the results of different PFA systems.
- 1 October 2022
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 15 (10) , e010992
Parametric Study of Pulsed Field Ablation With Biphasic Waveforms in an In Vivo Heart Model: The Role of Frequency
Background: Pulsed field ablation (PFA) is a novel nonthermal cardiac ablation technology based on irreversible electroporation. Unfortunately, the characteristics of the electric field waveforms used in clinical and experimental PFA are not typically reported. This study examines the effect of the frequency of biphasic waveforms and compares biphasic to monophasic waveforms. Methods: A total of 29 Sprague-Dawley rats were treated with PFA using an epicardial monopolar electrode. Biphasic waveforms with three different frequencies, 90, 260, and 450 kHz (10 bursts of 100 µs duration at 500 V or 800 V) and monophasic waveforms (10 pulses of 100 µs duration at 500 V) were studied. Collateral neuromuscular stimulation and temperature increase in the point of application were directly measured. Lesion formation was assessed 3 weeks after treatment by histopathologic analysis. Computer simulations were used to estimate the electric field lethal threshold for each condition. A previous in vitro study was performed to draw a complete characterization of the studied dependencies. Results: Morphometric analysis demonstrated a significant association between chronic lesion size and waveform characteristics. For the same voltage level, monophasic waveforms yielded the largest lesions compared with any of the biphasic protocols ( P <0.05). Increasing PFA frequency was associated with reduced neuromuscular stimulation but also with reduced ablation efficacy. Maximum absolute temperature increase recorded along a complete treatment was 3 °C. Vascular structures inside the lesions were preserved for all conditions. Computer simulation-based analysis showed that waveform frequency had a graded effect on the lethal electric field threshold, with threshold of 600 V/cm for monophasic waveforms versus 2000 V/cm for biphasic waveforms with a frequency of 450 kHz. Conclusions: Frequency is a major determinant of efficacy in biphasic PFA. Our results highlight the critical need of disclosing waveform characteristics when reporting the results of different PFA systems.
- 24 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 69 (4) , 1318-1327
Modeling Methods for Treatment Planning in Overlapping Electroporation Treatments
Objective: Irreversible electroporation (IRE) is a non-thermal tissue ablation therapy which is induced by applying high voltage waveforms across electrode pairs. When multiple electrode pairs are sequentially used, the treatment volume (TV) is typically computed as the geometric union of the TVs of individual pairs. However, this method neglects that some regions are exposed to overlapping treatments. Recently, a model describing cell survival probability was introduced which effectively predicted TV with overlapping fields in vivo . However, treatment overlap has yet to be quantified. This study characterizes TV overlap in a controlled in vitro setup with the two existing methods which are compared to an adapted logistic model proposed here. Methods : CHO cells were immobilized in agarose gel. Initially, we characterized the electric field threshold and the cell survival probability for overlapping treatments. Subsequently, we created a 2D setup where we compared and validated the accuracy of the different methods in predicting the TV. Results : Overlap can reduce the electric field threshold required to induce cell death, particularly for treatments with low pulse number. However, it does not have a major impact on TV in the models assayed here, and all the studied methods predict TV with similar accuracy. Conclusion : Treatment overlap has a minor influence in the TV for typical protocols found in IRE therapies. Significance : This study provides evidence that the modeling method used in most pre-clinical and clinical studies seems adequate.
- 24 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 69 (4) , 1318-1327
Modeling Methods for Treatment Planning in Overlapping Electroporation Treatments
Objective: Irreversible electroporation (IRE) is a non-thermal tissue ablation therapy which is induced by applying high voltage waveforms across electrode pairs. When multiple electrode pairs are sequentially used, the treatment volume (TV) is typically computed as the geometric union of the TVs of individual pairs. However, this method neglects that some regions are exposed to overlapping treatments. Recently, a model describing cell survival probability was introduced which effectively predicted TV with overlapping fields in vivo . However, treatment overlap has yet to be quantified. This study characterizes TV overlap in a controlled in vitro setup with the two existing methods which are compared to an adapted logistic model proposed here. Methods : CHO cells were immobilized in agarose gel. Initially, we characterized the electric field threshold and the cell survival probability for overlapping treatments. Subsequently, we created a 2D setup where we compared and validated the accuracy of the different methods in predicting the TV. Results : Overlap can reduce the electric field threshold required to induce cell death, particularly for treatments with low pulse number. However, it does not have a major impact on TV in the models assayed here, and all the studied methods predict TV with similar accuracy. Conclusion : Treatment overlap has a minor influence in the TV for typical protocols found in IRE therapies. Significance : This study provides evidence that the modeling method used in most pre-clinical and clinical studies seems adequate.
- 1 February 2021
- Published by Elsevier in Bioelectrochemistry
- Vol. 137, 107642
Electrophoresis-assisted accumulation of conductive nanoparticles for the enhancement of cell electropermeabilization
- 1 February 2021
- Published by Elsevier in Bioelectrochemistry
- Vol. 137, 107642
Electrophoresis-assisted accumulation of conductive nanoparticles for the enhancement of cell electropermeabilization