Kamal G. Shah
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Kamal G. Shah has a total of 78 co-authors. Here are the top co-authors by number of shared publications:
- Paul Yager
Department of Bioengineering, University of Washington, Seattle, Washington 98195, United States
3 shared publications - Barry R. Lutz
Department of Bioengineering, University of Washington, Seattle, WA, USA
2 shared publications Caitlin E. Anderson
Department of Bioengineering, University of Washington, Seattle, Washington 98195, United States
2 shared publicationsEnos C. Kline
Department of Bioengineering, University of Washington, Seattle, WA 98195-5061, USA
2 shared publicationsGaurav K. Gulati
Department of Bioengineering, University of Washington, Seattle, WA 98195-5061, USA
2 shared publications- Ian T. Hull
Department of Bioengineering, University of Washington, Seattle, WA, USA
2 shared publications
Latest Publications
- 17 December 2021
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 94 (2) , 1011-1021
Isothermal Amplification with a Target-Mimicking Internal Control and Quantitative Lateral Flow Readout for Rapid HIV Viral Load Testing in Low-Resource Settings
Point-of-care diagnostics often use isothermal nucleic acid amplification for qualitative detection of pathogens in low-resource healthcare settings but lack sufficient precision for quantitative applications such as HIV viral load monitoring. Although viral load (VL) monitoring is an essential component of HIV treatment, commercially available tests rely on relatively high-resource chemistries like real-time polymerase chain reaction and are thus used on an infrequent basis for millions of people living with HIV in low-income countries. To address the constraints of low-resource settings on nucleic acid quantification, we describe a recombinase polymerase amplification and lateral flow detection approach that quantifies HIV-1 DNA or RNA by comparison to a competitive internal amplification control (IAC) of a known copy number, which may be set to any useful threshold (in our case, a clinically relevant threshold for HIV treatment failure). The IAC is designed to amplify alongside the HIV target with a similar efficiency, allowing for normalization of the assay to variation or inhibition and enabling an endpoint readout that is compatible with commercially available kits for nucleic acid lateral flow detection and interpretable with minimal instrumentation or by the naked eye. We find that this approach can reliably differentiate ≤600 or ≥1400 copies of HIV DNA from a 1000-copy threshold when lateral flow strips are imaged with a conventional office scanner and analyzed with free densitometry software. We further demonstrate a user-friendly adaptation of this analysis to process cell phone photographs with an automated script. Alternatively, we show via a survey that 21 minimally trained volunteers could reliably resolve ≥10-fold (log10) differences of HIV DNA or RNA by naked eye interpretation of lateral flow results. This amplification and detection workflow requires minimal instrumentation, takes just 30 min to complete, and when combined with a suitable sample preparation method, may enable HIV VL testing while the patient waits or a self-test, which has the potential to improve care. This approach may be adapted for other applications that require quantitative analysis of a nucleic acid target in low-resource settings.
- 17 December 2021
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 94 (2) , 1011-1021
Isothermal Amplification with a Target-Mimicking Internal Control and Quantitative Lateral Flow Readout for Rapid HIV Viral Load Testing in Low-Resource Settings
Point-of-care diagnostics often use isothermal nucleic acid amplification for qualitative detection of pathogens in low-resource healthcare settings but lack sufficient precision for quantitative applications such as HIV viral load monitoring. Although viral load (VL) monitoring is an essential component of HIV treatment, commercially available tests rely on relatively high-resource chemistries like real-time polymerase chain reaction and are thus used on an infrequent basis for millions of people living with HIV in low-income countries. To address the constraints of low-resource settings on nucleic acid quantification, we describe a recombinase polymerase amplification and lateral flow detection approach that quantifies HIV-1 DNA or RNA by comparison to a competitive internal amplification control (IAC) of a known copy number, which may be set to any useful threshold (in our case, a clinically relevant threshold for HIV treatment failure). The IAC is designed to amplify alongside the HIV target with a similar efficiency, allowing for normalization of the assay to variation or inhibition and enabling an endpoint readout that is compatible with commercially available kits for nucleic acid lateral flow detection and interpretable with minimal instrumentation or by the naked eye. We find that this approach can reliably differentiate ≤600 or ≥1400 copies of HIV DNA from a 1000-copy threshold when lateral flow strips are imaged with a conventional office scanner and analyzed with free densitometry software. We further demonstrate a user-friendly adaptation of this analysis to process cell phone photographs with an automated script. Alternatively, we show via a survey that 21 minimally trained volunteers could reliably resolve ≥10-fold (log10) differences of HIV DNA or RNA by naked eye interpretation of lateral flow results. This amplification and detection workflow requires minimal instrumentation, takes just 30 min to complete, and when combined with a suitable sample preparation method, may enable HIV VL testing while the patient waits or a self-test, which has the potential to improve care. This approach may be adapted for other applications that require quantitative analysis of a nucleic acid target in low-resource settings.
- 19 August 2020
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 92 (19) , 13066-13072
Two-Fluorophore Mobile Phone Imaging of Biplexed Real-Time NAATs Overcomes Optical Artifacts in Highly Scattering Porous Media
Nucleic acid amplification tests (NAATs) are common in laboratory and clinical settings due to their low time to result and exquisite sensitivity and specificity. Laboratory NAATs include onboard positive controls to reduce false negatives and specialized hardware to enable real-time fluorescence detection. Recent efforts to translate NAATs into at-home tests sacrifice one or more of the benefits of laboratory NAATs, such as sensitivity, internal amplification controls (IACs), or time to result. In this manuscript, we describe a mobile-phone-based strategy for real-time imaging of biplexed NAATs in paper. The strategy consisted of 1) using mobile phones with multipass excitation and emission filters on the flash and camera to image the signal from distinct fluorophore-labeled probe types in a duplexed NAAT in a glass fiber membrane; and 2) analyzing the differential fluorescence signal between the red and green color channels of phone images to overcome a strong evaporation-induced optical artifact in heated glass fiber pads due to changes in refractive index. We demonstrated that the differential fluorescence imaging enabled low limits of detection (316 copies of methicillin-resistant Staphylococcus aureus DNA) in our lab’s MD NAAT platform, even in biplexed isothermal strand displacement amplification (iSDA) reactions containing 100k copies of co-amplifying IAC DNA template. These results suggest that two-fluorophore mobile phone imaging may enable translating the benefits of extant laboratory-based, real-time NAATs to the point of care.
- 19 August 2020
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 92 (19) , 13066-13072
Two-Fluorophore Mobile Phone Imaging of Biplexed Real-Time NAATs Overcomes Optical Artifacts in Highly Scattering Porous Media
Nucleic acid amplification tests (NAATs) are common in laboratory and clinical settings due to their low time to result and exquisite sensitivity and specificity. Laboratory NAATs include onboard positive controls to reduce false negatives and specialized hardware to enable real-time fluorescence detection. Recent efforts to translate NAATs into at-home tests sacrifice one or more of the benefits of laboratory NAATs, such as sensitivity, internal amplification controls (IACs), or time to result. In this manuscript, we describe a mobile-phone-based strategy for real-time imaging of biplexed NAATs in paper. The strategy consisted of 1) using mobile phones with multipass excitation and emission filters on the flash and camera to image the signal from distinct fluorophore-labeled probe types in a duplexed NAAT in a glass fiber membrane; and 2) analyzing the differential fluorescence signal between the red and green color channels of phone images to overcome a strong evaporation-induced optical artifact in heated glass fiber pads due to changes in refractive index. We demonstrated that the differential fluorescence imaging enabled low limits of detection (316 copies of methicillin-resistant Staphylococcus aureus DNA) in our lab’s MD NAAT platform, even in biplexed isothermal strand displacement amplification (iSDA) reactions containing 100k copies of co-amplifying IAC DNA template. These results suggest that two-fluorophore mobile phone imaging may enable translating the benefits of extant laboratory-based, real-time NAATs to the point of care.
- 1 May 2018
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 90 (11) , 6967-6974
Mobile Phone Ratiometric Imaging Enables Highly Sensitive Fluorescence Lateral Flow Immunoassays without External Optical Filters
Paper-based diagnostic tests based on the lateral flow immunoassay concept promise low-cost, point-of-care detection of infectious diseases, but such assays suffer from poor limits of detection. One factor that contributes to poor analytical performance is a reliance on low contrast chromophoric optical labels such as gold nanoparticles. Previous attempts to improve the sensitivity of paper-based diagnostics include replacing chromophoric labels with enzymes, fluorophores, or phosphors at the expense of increased fluidic complexity or the need for device readers with costly optoelectronics. Several groups, including our own, have proposed mobile phones as suitable point-of-care readers due to their low cost, ease of use, and ubiquity. However, extant mobile phone fluorescence readers require costly optical filters and were typically validated with only one camera sensor module, which is inappropriate for potential point-of-care use. In response, we propose to couple low-cost ultraviolet light-emitting diodes with long Stokes-shift quantum dots to enable ratiometric mobile phone fluorescence measurements without optical filters. Ratiometric imaging with unmodified smartphone cameras improves the contrast and attenuates the impact of excitation intensity variability by 15x. Practical application was shown with a lateral flow immunoassay for influenza A with nucleoproteins spiked into simulated nasal matrix. Limits of detection of 1.5 and 2.6 fmol were attained on two mobile phones, which are comparable to a gel imager (1.9 fmol), 10x better than imaging gold nanoparticles on a scanner (18 fmol), and >2 orders of magnitude better than gold nanoparticle-labeled assays imaged with mobile phones. Use of the proposed filter-free mobile phone imaging scheme is a first step toward enabling a new generation of highly sensitive, point-of-care fluorescence assays.
- 1 May 2018
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 90 (11) , 6967-6974
Mobile Phone Ratiometric Imaging Enables Highly Sensitive Fluorescence Lateral Flow Immunoassays without External Optical Filters
Paper-based diagnostic tests based on the lateral flow immunoassay concept promise low-cost, point-of-care detection of infectious diseases, but such assays suffer from poor limits of detection. One factor that contributes to poor analytical performance is a reliance on low contrast chromophoric optical labels such as gold nanoparticles. Previous attempts to improve the sensitivity of paper-based diagnostics include replacing chromophoric labels with enzymes, fluorophores, or phosphors at the expense of increased fluidic complexity or the need for device readers with costly optoelectronics. Several groups, including our own, have proposed mobile phones as suitable point-of-care readers due to their low cost, ease of use, and ubiquity. However, extant mobile phone fluorescence readers require costly optical filters and were typically validated with only one camera sensor module, which is inappropriate for potential point-of-care use. In response, we propose to couple low-cost ultraviolet light-emitting diodes with long Stokes-shift quantum dots to enable ratiometric mobile phone fluorescence measurements without optical filters. Ratiometric imaging with unmodified smartphone cameras improves the contrast and attenuates the impact of excitation intensity variability by 15x. Practical application was shown with a lateral flow immunoassay for influenza A with nucleoproteins spiked into simulated nasal matrix. Limits of detection of 1.5 and 2.6 fmol were attained on two mobile phones, which are comparable to a gel imager (1.9 fmol), 10x better than imaging gold nanoparticles on a scanner (18 fmol), and >2 orders of magnitude better than gold nanoparticle-labeled assays imaged with mobile phones. Use of the proposed filter-free mobile phone imaging scheme is a first step toward enabling a new generation of highly sensitive, point-of-care fluorescence assays.
- 31 October 2017
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 89 (22) , 12023-12029
Wavelengths and Lifetimes of Paper Autofluorescence: A Simple Substrate Screening Process to Enhance the Sensitivity of Fluorescence-Based Assays in Paper
Porous media made of nitrocellulose and glass fiber are common “paper” substrates for lateral flow assays, microfluidic paper analytical devices and other point-of-care diagnostic assays. Such assays commonly use optical labels such as gold nanoparticles, latex beads, or fluorescent nanoparticles to visualize the presence of analytes. Fluorescent labels are commonly used in bioassays to enhance sensitivity, but autoluminescence of the paper substrate worsens signal-to-noise ratios of fluorescence-based assays. To date, there exists no systematic investigation of autoluminescence wavelengths or lifetimes of porous membranes used in lateral flow assays. In response, we quantified the autoluminescence of commonly used porous materials across the visible spectrum via excitation–emission spectroscopy and time-resolved fluorescence spectroscopy, and demonstrate that autoluminescence is solely due to autofluorescence with lifetimes of about 5 ns in the visible spectrum. Counterintuitively, we found that spectroscopy alone does not provide sufficient information to select candidate paper substrates for fluorophore-labeled assays. Therefore, we developed a simple quantitative framework to select a low-fluorescence substrate that minimizes both the overlap of paper and fluorophore emission spectra and the fluorescence intensity on an imaging system of interest (such as a gel imager). Use of this framework was shown to lower the limit of detection of an influenza A nucleoprotein immunoassay by over 50%. The tools developed in this manuscript enable assay developers to screen appropriate, low-fluorescence porous substrates and enhance the sensitivity of membrane-based fluorescence assays.
- 31 October 2017
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 89 (22) , 12023-12029
Wavelengths and Lifetimes of Paper Autofluorescence: A Simple Substrate Screening Process to Enhance the Sensitivity of Fluorescence-Based Assays in Paper
Porous media made of nitrocellulose and glass fiber are common “paper” substrates for lateral flow assays, microfluidic paper analytical devices and other point-of-care diagnostic assays. Such assays commonly use optical labels such as gold nanoparticles, latex beads, or fluorescent nanoparticles to visualize the presence of analytes. Fluorescent labels are commonly used in bioassays to enhance sensitivity, but autoluminescence of the paper substrate worsens signal-to-noise ratios of fluorescence-based assays. To date, there exists no systematic investigation of autoluminescence wavelengths or lifetimes of porous membranes used in lateral flow assays. In response, we quantified the autoluminescence of commonly used porous materials across the visible spectrum via excitation–emission spectroscopy and time-resolved fluorescence spectroscopy, and demonstrate that autoluminescence is solely due to autofluorescence with lifetimes of about 5 ns in the visible spectrum. Counterintuitively, we found that spectroscopy alone does not provide sufficient information to select candidate paper substrates for fluorophore-labeled assays. Therefore, we developed a simple quantitative framework to select a low-fluorescence substrate that minimizes both the overlap of paper and fluorophore emission spectra and the fluorescence intensity on an imaging system of interest (such as a gel imager). Use of this framework was shown to lower the limit of detection of an influenza A nucleoprotein immunoassay by over 50%. The tools developed in this manuscript enable assay developers to screen appropriate, low-fluorescence porous substrates and enhance the sensitivity of membrane-based fluorescence assays.
- 8 May 2017
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 89 (11) , 5776-5783
Disposable Autonomous Device for Swab-to-Result Diagnosis of Influenza
A prototype of a self-contained, automated, disposable device for chemically amplified protein-based detection of influenza virus from nasal swab specimens was developed and evaluated in a clinical setting. The device required only simple specimen manipulation without any dedicated instrumentation or specialized training by the operator for interpretation. The device was based on a sandwich immunoassay for influenza virus nucleoprotein; it used an enzyme-labeled antibody and a chromogenic substrate to provide an amplified visible signal, in a two-dimensional paper network format. All reagents were stored within the device. Device performance was assessed at Seattle Children’s Hospital; clinical staff collected nasal swab samples from 25 patients and then operated test devices on site to detect influenza A and B in those specimens. The total test time from device initiation to result was approximately 35 min. Device performance for influenza A detection was ∼70% accurate using in-house qRT-PCR influenza A as a gold-standard comparison. The ratio of valid to total completed device runs yielded a success rate of 92%, and the negative predictive value for both the influenza A and B assay was 81%. The ability to diagnose respiratory infections rapidly and close to the patient was well received by hospital staff, inspiring further optimization of device function.
- 8 May 2017
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 89 (11) , 5776-5783
Disposable Autonomous Device for Swab-to-Result Diagnosis of Influenza
A prototype of a self-contained, automated, disposable device for chemically amplified protein-based detection of influenza virus from nasal swab specimens was developed and evaluated in a clinical setting. The device required only simple specimen manipulation without any dedicated instrumentation or specialized training by the operator for interpretation. The device was based on a sandwich immunoassay for influenza virus nucleoprotein; it used an enzyme-labeled antibody and a chromogenic substrate to provide an amplified visible signal, in a two-dimensional paper network format. All reagents were stored within the device. Device performance was assessed at Seattle Children’s Hospital; clinical staff collected nasal swab samples from 25 patients and then operated test devices on site to detect influenza A and B in those specimens. The total test time from device initiation to result was approximately 35 min. Device performance for influenza A detection was ∼70% accurate using in-house qRT-PCR influenza A as a gold-standard comparison. The ratio of valid to total completed device runs yielded a success rate of 92%, and the negative predictive value for both the influenza A and B assay was 81%. The ability to diagnose respiratory infections rapidly and close to the patient was well received by hospital staff, inspiring further optimization of device function.
- 1 January 2017
- Published by Elsevier
- Vol. 589, 383-411
Sensitive Protein Detection and Quantification in Paper-Based Microfluidics for the Point of Care
- 1 January 2017
- Published by Elsevier
- Vol. 589, 383-411
Sensitive Protein Detection and Quantification in Paper-Based Microfluidics for the Point of Care
- Open Access
- 2 October 2015
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 10 (10) , e0139449
Design of a New Type of Compact Chemical Heater for Isothermal Nucleic Acid Amplification
Previous chemical heater designs for isothermal nucleic acid amplification have been based on solid-liquid phase transition, but using this approach, developers have identified design challenges en route to developing a low-cost, disposable device. Here, we demonstrate the feasibility of a new heater configuration suitable for isothermal amplification in which one reactant of an exothermic reaction is a liquid-gas phase-change material, thereby eliminating the need for a separate phase-change compartment. This design offers potentially enhanced performance and energy density compared to other chemical and electric heaters.
- 2 October 2015
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 10 (10) , e0139449
Open AccessDesign of a New Type of Compact Chemical Heater for Isothermal Nucleic Acid Amplification
Previous chemical heater designs for isothermal nucleic acid amplification have been based on solid-liquid phase transition, but using this approach, developers have identified design challenges en route to developing a low-cost, disposable device. Here, we demonstrate the feasibility of a new heater configuration suitable for isothermal amplification in which one reactant of an exothermic reaction is a liquid-gas phase-change material, thereby eliminating the need for a separate phase-change compartment. This design offers potentially enhanced performance and energy density compared to other chemical and electric heaters.
- 6 May 2015
- Published by American Society of Tropical Medicine and Hygiene in The American Journal of Tropical Medicine and Hygiene
- Vol. 92 (5) , 1053-1058
Maji: A New Tool to Prevent Overhydration of Children Receiving Intravenous Fluid Therapy in Low-Resource Settings
We designed and evaluated the accuracy and usability of a device to regulate the volume of fluid dispensed during intravenous drip therapy. The mechanical system was developed in response to a pressing need articulated by clinicians in pediatric wards throughout sub-Saharan Africa, who require a tool to prevent overhydration in children receiving intravenous fluid in settings that lack burettes or electronic infusion pumps. The device is compatible with most intravenous bags and limits the volume dispensed to a preset amount that can be adjusted in 50 mL increments. Laboratory accuracy over a range of clinically relevant flow rates, initial bag volumes, and target volumes was within 12.0 mL of the target volume. The ease of use is “excellent,” with a mean system usability score of 84.4 out of 100. Use of the device limits the volume of fluid dispensed during intravenous therapy and could potentially reduce the morbidity and mortality associated with overhydration in children receiving intravenous therapy.
- 6 May 2015
- Published by American Society of Tropical Medicine and Hygiene in The American Journal of Tropical Medicine and Hygiene
- Vol. 92 (5) , 1053-1058
Maji: A New Tool to Prevent Overhydration of Children Receiving Intravenous Fluid Therapy in Low-Resource Settings
We designed and evaluated the accuracy and usability of a device to regulate the volume of fluid dispensed during intravenous drip therapy. The mechanical system was developed in response to a pressing need articulated by clinicians in pediatric wards throughout sub-Saharan Africa, who require a tool to prevent overhydration in children receiving intravenous fluid in settings that lack burettes or electronic infusion pumps. The device is compatible with most intravenous bags and limits the volume dispensed to a preset amount that can be adjusted in 50 mL increments. Laboratory accuracy over a range of clinically relevant flow rates, initial bag volumes, and target volumes was within 12.0 mL of the target volume. The ease of use is “excellent,” with a mean system usability score of 84.4 out of 100. Use of the device limits the volume of fluid dispensed during intravenous therapy and could potentially reduce the morbidity and mortality associated with overhydration in children receiving intravenous therapy.
- Open Access
- 14 August 2013
- Published by Springer Nature in BMC Palliative Care
- Vol. 12 (1) , 31
Novel open-source electronic medical records system for palliative care in low-resource settings
Background: The need for palliative care in sub-Saharan Africa is staggering: this region shoulders over 67% of the global burden of HIV/AIDS and cancer. However, provisions for these essential services remain limited and poorly integrated with national health systems in most nations. Moreover, the evidence base for palliative care in the region remains scarce. This study chronicles the development and evaluation of DataPall, an open-source electronic medical records system that can be used to track patients, manage data, and generate reports for palliative care providers in these settings. DataPall was developed using design criteria encompassing both functional and technical objectives articulated by hospital leaders and palliative care staff at a leading palliative care center in Malawi. The database can be used with computers that run Windows XP SP 2 or newer, and does not require an internet connection for use. Subsequent to its development and implementation in two hospitals, DataPall was tested among both trained and untrained hospital staff populations on the basis of its usability with comparison to existing paper records systems as well as on the speed at which users could perform basic database functions. Additionally, all participants evaluated this program on a standard system usability scale. Results: In a study of health professionals in a Malawian hospital, DataPall enabled palliative care providers to find patients’ appointments, on average, in less than half the time required to locate the same record in current paper records. Moreover, participants generated customizable reports documenting patient records and comprehensive reports on providers’ activities with little training necessary. Participants affirmed this ease of use on the system usability scale. Conclusions: DataPall is a simple, effective electronic medical records system that can assist in developing an evidence base of clinical data for palliative care in low resource settings. The system is available at no cost, is specifically designed to chronicle care in the region, and is catered to meet the technical needs and user specifications of such facilities.
- 14 August 2013
- Published by Springer Nature in BMC Palliative Care
- Vol. 12 (1) , 31
Open AccessNovel open-source electronic medical records system for palliative care in low-resource settings
Background: The need for palliative care in sub-Saharan Africa is staggering: this region shoulders over 67% of the global burden of HIV/AIDS and cancer. However, provisions for these essential services remain limited and poorly integrated with national health systems in most nations. Moreover, the evidence base for palliative care in the region remains scarce. This study chronicles the development and evaluation of DataPall, an open-source electronic medical records system that can be used to track patients, manage data, and generate reports for palliative care providers in these settings. DataPall was developed using design criteria encompassing both functional and technical objectives articulated by hospital leaders and palliative care staff at a leading palliative care center in Malawi. The database can be used with computers that run Windows XP SP 2 or newer, and does not require an internet connection for use. Subsequent to its development and implementation in two hospitals, DataPall was tested among both trained and untrained hospital staff populations on the basis of its usability with comparison to existing paper records systems as well as on the speed at which users could perform basic database functions. Additionally, all participants evaluated this program on a standard system usability scale. Results: In a study of health professionals in a Malawian hospital, DataPall enabled palliative care providers to find patients’ appointments, on average, in less than half the time required to locate the same record in current paper records. Moreover, participants generated customizable reports documenting patient records and comprehensive reports on providers’ activities with little training necessary. Participants affirmed this ease of use on the system usability scale. Conclusions: DataPall is a simple, effective electronic medical records system that can assist in developing an evidence base of clinical data for palliative care in low resource settings. The system is available at no cost, is specifically designed to chronicle care in the region, and is catered to meet the technical needs and user specifications of such facilities.