Prabodh Kumar Pandey
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Prabodh Kumar Pandey has a total of 54 co-authors. Here are the top co-authors by number of shared publications:
- Liangzhong Xiang
Department of Radiological Sciences, University of California 1 , Irvine, California 92697
10 shared publications - Naren Naik
Department of Electrical Engineering, Indian Institute of Technology Kanpurhttps://ror.org/03g5ew477, Kanpur, Uttar Pradesh 208016, India
6 shared publications - Asima Pradhan
Indian Institute of Technology Kanpur
5 shared publications Leshan Sun
University of California
5 shared publications- Kristina Bjegovic
Biomedical Engineering, University of California Irvine, 825 Health Sciences Road, Irvine, California, 92697, UNITED STATES
4 shared publications - Omprakash Gottam
Department of Electronics and Communications, Koneru Lakshmaiah Education Foundation, KLEF Hyderabad, Aziz Nagar, Hyderabad, 500075, India
4 shared publications
Latest Publications
- Open Access
- 6 July 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (13) , 135020
Volumetric FLASH dosimetry in vivo using real-time radiacoustic imaging
Objective. The main goal of this research is to verify the spatial fidelity of radiacoustic imaging (RAI) as a quantitative dosimetric monitoring tool for FLASH radiotherapy (FLASH-RT) in vivo . FLASH-RT delivers therapeutic radiation at ultra-high instantaneous dose rates (>10 6 Gy s −1 ), offering substantial reductions in normal tissue toxicity while maintaining tumor control. However, clinical translation remains limited by the absence of real-time, in vivo dosimetry systems capable of resolving dose delivery at microsecond timescales. Approach. Here, we present an RAI platform that enables volumetric, single-pulse mapping of radiation dose deposition during FLASH-RT in vivo . The system utilizes a 16 × 16 ultrasound transducer matrix array with a model-based reconstruction algorithm to generate quantitative, three-dimensional dose maps with single pulse-level temporal resolution. Main results. In both water phantoms and in vivo murine models, RAI demonstrates high concordance with film dosimetry and TOPAS Monte Carlo simulations (3%/3 mm gamma index pass rates greater than 90% for small fields). Significance. This work establishes RAI as a viable technology for real-time, quantitative electron FLASH dosimetry in vivo for the first time, with the potential to support adaptive delivery, improve treatment safety, and facilitate the clinical translation of FLASH-RT.
- 6 July 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (13) , 135020
Open AccessVolumetric FLASH dosimetry in vivo using real-time radiacoustic imaging
Objective. The main goal of this research is to verify the spatial fidelity of radiacoustic imaging (RAI) as a quantitative dosimetric monitoring tool for FLASH radiotherapy (FLASH-RT) in vivo . FLASH-RT delivers therapeutic radiation at ultra-high instantaneous dose rates (>10 6 Gy s −1 ), offering substantial reductions in normal tissue toxicity while maintaining tumor control. However, clinical translation remains limited by the absence of real-time, in vivo dosimetry systems capable of resolving dose delivery at microsecond timescales. Approach. Here, we present an RAI platform that enables volumetric, single-pulse mapping of radiation dose deposition during FLASH-RT in vivo . The system utilizes a 16 × 16 ultrasound transducer matrix array with a model-based reconstruction algorithm to generate quantitative, three-dimensional dose maps with single pulse-level temporal resolution. Main results. In both water phantoms and in vivo murine models, RAI demonstrates high concordance with film dosimetry and TOPAS Monte Carlo simulations (3%/3 mm gamma index pass rates greater than 90% for small fields). Significance. This work establishes RAI as a viable technology for real-time, quantitative electron FLASH dosimetry in vivo for the first time, with the potential to support adaptive delivery, improve treatment safety, and facilitate the clinical translation of FLASH-RT.
- 22 June 2026
- Published by AIP Publishing in Applied Physics Letters
- Vol. 128 (25)
Shape-optimized model-based reconstruction algorithm for radiacoustic imaging
We present a shape-optimized model-based reconstruction framework that addresses the limited-view problem in radiacoustic imaging arising from restricted detector placement, which creates severely ill-posed inverse problems that manifest as characteristic artifacts in reconstructed images. We first reconstruct an approximate dose-region boundary using a parametric level set–based shape optimization. Pointwise model-based dose reconstruction is then performed only within this shape-constrained region. By restricting reconstruction from the full imaging domain to only the pixels within the identified region, the number of unknowns is significantly reduced, transforming a severely ill-posed inverse problem into a much better-constrained one. We validate this methodology through computational studies and experiments using clinical x-ray and proton radiation sources under limited angular coverage data acquisition settings. Results demonstrate substantial artifact reduction and improved accuracy compared to standard model-based reconstructions, with a 3%–25% improvement in correlation coefficients across different imaging settings, with the more pronounced improvements occurring under stronger limited-view conditions. This shape-optimized approach provides a viable pathway for accurate radiation therapy monitoring under clinically realistic detector configurations.
- 22 June 2026
- Published by AIP Publishing in Applied Physics Letters
- Vol. 128 (25)
Shape-optimized model-based reconstruction algorithm for radiacoustic imaging
We present a shape-optimized model-based reconstruction framework that addresses the limited-view problem in radiacoustic imaging arising from restricted detector placement, which creates severely ill-posed inverse problems that manifest as characteristic artifacts in reconstructed images. We first reconstruct an approximate dose-region boundary using a parametric level set–based shape optimization. Pointwise model-based dose reconstruction is then performed only within this shape-constrained region. By restricting reconstruction from the full imaging domain to only the pixels within the identified region, the number of unknowns is significantly reduced, transforming a severely ill-posed inverse problem into a much better-constrained one. We validate this methodology through computational studies and experiments using clinical x-ray and proton radiation sources under limited angular coverage data acquisition settings. Results demonstrate substantial artifact reduction and improved accuracy compared to standard model-based reconstructions, with a 3%–25% improvement in correlation coefficients across different imaging settings, with the more pronounced improvements occurring under stronger limited-view conditions. This shape-optimized approach provides a viable pathway for accurate radiation therapy monitoring under clinically realistic detector configurations.
- 20 February 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (4) , 045010
Fully non-linear blob basis based fluorescence photoacoustic pharmaco-kinetic tomography using non-sequential sensitivity evaluations
Objective. In this work, we solve the fully non-linear dynamic pharmacokinetic fluorescence photoacoustic tomography (PK-FPAT) problem for pointwise reconstructions for the first time in literature. Approach. We use the 2D-blob basis functions to represent the object, which have been known to yield very good localization in reconstructions, while significantly reducing the number of unknowns. The underlying state derivatives are evaluated via an efficient non-sequential sensitivity scheme for obtaining the derivatives of the two-compartment model. The inverse problem is solved in a dual-grid framework, where the forward problem is solved on a standard finite element grid at each iterate, while reconstructing the parameters in blob basis via Gauss–Newton and gradient filtering schemes. Main results. To the best of our knowledge, the current work demonstrates the first pointwise formulation and reconstructions for fully nonlinear PK-FPAT. Non-sequential sensitivity based gradient and Gauss–Newton filters-based reconstruction frameworks in a blob-basis representation have been developed. Numerical studies on cancer-mimicking phantoms validate the proposed scheme, yielding good localization of the reconstructed parameters with satisfactory correspondence to the ground-truth parameter values. Significance. The proposed non-sequential state derivative framework with the blob-basis representations offers significant computational advantages via both efficient evaluation of state derivatives and the sparse representations of the parameters, therein enabling the scalability of PK-FPAT based PK imaging to full 3D point-wise reconstructions for real world imaging.
- 20 February 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (4) , 045010
Fully non-linear blob basis based fluorescence photoacoustic pharmaco-kinetic tomography using non-sequential sensitivity evaluations
Objective. In this work, we solve the fully non-linear dynamic pharmacokinetic fluorescence photoacoustic tomography (PK-FPAT) problem for pointwise reconstructions for the first time in literature. Approach. We use the 2D-blob basis functions to represent the object, which have been known to yield very good localization in reconstructions, while significantly reducing the number of unknowns. The underlying state derivatives are evaluated via an efficient non-sequential sensitivity scheme for obtaining the derivatives of the two-compartment model. The inverse problem is solved in a dual-grid framework, where the forward problem is solved on a standard finite element grid at each iterate, while reconstructing the parameters in blob basis via Gauss–Newton and gradient filtering schemes. Main results. To the best of our knowledge, the current work demonstrates the first pointwise formulation and reconstructions for fully nonlinear PK-FPAT. Non-sequential sensitivity based gradient and Gauss–Newton filters-based reconstruction frameworks in a blob-basis representation have been developed. Numerical studies on cancer-mimicking phantoms validate the proposed scheme, yielding good localization of the reconstructed parameters with satisfactory correspondence to the ground-truth parameter values. Significance. The proposed non-sequential state derivative framework with the blob-basis representations offers significant computational advantages via both efficient evaluation of state derivatives and the sparse representations of the parameters, therein enabling the scalability of PK-FPAT based PK imaging to full 3D point-wise reconstructions for real world imaging.
- 17 February 2025
- Published by AIP Publishing in Applied Physics Letters
- Vol. 126 (7) , 074102
3D protoacoustic radiography: A proof of principle study
We propose protoacoustic radiography (PAR), an imaging modality combining proton excitation and acoustic detection for three-dimensional (3D) imaging from a single proton projection. PAR avoids the effect of multiple Coulomb scattering in imaging by detecting ultrasound. Proton-induced acoustic waves propagate spherically, enabling 3D imaging from a single projection. Additionally, the distinctive feature of proton beams—concentrating energy deposition primarily at the Bragg peak—allows for precise depth-selectivity through proton energy tuning. We performed PAR using clinical proton machines, and our results demonstrate the capability of PAR to reconstruct targets at various depths (between ∼20 and 23 cm) with an axial resolution of 1.3 mm by fully leveraging the Bragg peak and by tuning the kinetic energy of the proton beam. PAR offers opportunities for precise structural determination with protons both in biomedicine and nondestructive testing.
- 17 February 2025
- Published by AIP Publishing in Applied Physics Letters
- Vol. 126 (7) , 074102
3D protoacoustic radiography: A proof of principle study
We propose protoacoustic radiography (PAR), an imaging modality combining proton excitation and acoustic detection for three-dimensional (3D) imaging from a single proton projection. PAR avoids the effect of multiple Coulomb scattering in imaging by detecting ultrasound. Proton-induced acoustic waves propagate spherically, enabling 3D imaging from a single projection. Additionally, the distinctive feature of proton beams—concentrating energy deposition primarily at the Bragg peak—allows for precise depth-selectivity through proton energy tuning. We performed PAR using clinical proton machines, and our results demonstrate the capability of PAR to reconstruct targets at various depths (between ∼20 and 23 cm) with an axial resolution of 1.3 mm by fully leveraging the Bragg peak and by tuning the kinetic energy of the proton beam. PAR offers opportunities for precise structural determination with protons both in biomedicine and nondestructive testing.
- Open Access
- 6 December 2024
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 10 (49) , eads1584
X-ray–induced acoustic computed tomography: 3D X-ray absorption imaging from a single view
Computed tomography (CT) scanners are essential for modern imaging but require around 600 projections from various angles. We present x-ray–induced acoustic computed tomography (XACT), a method that uses radiation-induced acoustic waves for three-dimensional (3D) x-ray imaging. These spherical acoustic waves travel through tissue at 1.5 × 10 3 meters per second, much slower than x-rays, allowing ultrasound detectors to capture them and generate 3D images without mechanical scanning. We validate this theory by performing 3D numerical reconstructions of a human breast from a single x-ray projection and experimentally determining 3D structures of objects at different depths. Achieving resolutions of 0.4 millimeters in the XZ plane and 3.5 millimeters in the XY plane at a depth of 16 millimeters, XACT demonstrates the ability to produce 3D images from one x-ray projection, reducing radiation exposure and enabling gantry-free imaging. XACT shows great promise for biomedical and nondestructive testing applications, potentially replacing conventional CT.
- 6 December 2024
- Published by American Association for the Advancement of Science (AAAS) in Science Advances
- Vol. 10 (49) , eads1584
Open AccessX-ray–induced acoustic computed tomography: 3D X-ray absorption imaging from a single view
Computed tomography (CT) scanners are essential for modern imaging but require around 600 projections from various angles. We present x-ray–induced acoustic computed tomography (XACT), a method that uses radiation-induced acoustic waves for three-dimensional (3D) x-ray imaging. These spherical acoustic waves travel through tissue at 1.5 × 10 3 meters per second, much slower than x-rays, allowing ultrasound detectors to capture them and generate 3D images without mechanical scanning. We validate this theory by performing 3D numerical reconstructions of a human breast from a single x-ray projection and experimentally determining 3D structures of objects at different depths. Achieving resolutions of 0.4 millimeters in the XZ plane and 3.5 millimeters in the XY plane at a depth of 16 millimeters, XACT demonstrates the ability to produce 3D images from one x-ray projection, reducing radiation exposure and enabling gantry-free imaging. XACT shows great promise for biomedical and nondestructive testing applications, potentially replacing conventional CT.
- 21 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 9 (6) , 815-820
Combined XA/CT Imaging for Bone Density and Elasticity Evaluation: A Simulation Study
Osteoporosis is a significant public health concern that affects old adults and individuals with certain medical conditions. In this work, we demonstrate the proof of the principle of combining the emerging new radiological imaging technique, X-ray-induced acoustic (XA) imaging, and X-ray computed tomography (CT) for bone density and elasticity evaluation. This combined method is intended for use in single scanner that can perform both XA imaging and CT imaging simultaneously for the purpose of providing accurately registered anatomical localization of structures seen in the CT image to extract the elasticity information in XA imaging. We demonstrate that our nonlinear optimization algorithm can acquire the speed of sound information for bone. By combining the speed of sound and density information from CT, we can calculate the elasticity with an error of less than 1%. We conclude that using CT information as prior information is a feasible way to obtain elasticity information in XA imaging. These findings enable more accurate osteoporosis diagnosis through both bone density and bone strength evaluation using one integrated system in the future.
- 21 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Radiation and Plasma Medical Sciences
- Vol. 9 (6) , 815-820
Combined XA/CT Imaging for Bone Density and Elasticity Evaluation: A Simulation Study
Osteoporosis is a significant public health concern that affects old adults and individuals with certain medical conditions. In this work, we demonstrate the proof of the principle of combining the emerging new radiological imaging technique, X-ray-induced acoustic (XA) imaging, and X-ray computed tomography (CT) for bone density and elasticity evaluation. This combined method is intended for use in single scanner that can perform both XA imaging and CT imaging simultaneously for the purpose of providing accurately registered anatomical localization of structures seen in the CT image to extract the elasticity information in XA imaging. We demonstrate that our nonlinear optimization algorithm can acquire the speed of sound information for bone. By combining the speed of sound and density information from CT, we can calculate the elasticity with an error of less than 1%. We conclude that using CT information as prior information is a feasible way to obtain elasticity information in XA imaging. These findings enable more accurate osteoporosis diagnosis through both bone density and bone strength evaluation using one integrated system in the future.
- 8 October 2024
- Published by Wiley in Journal of Biophotonics
- Vol. 17 (11) , e202400284
Spatially Resolved Fibre‐Optic Probe for Cervical Precancer Detection Using Fluorescence Spectroscopy and PCA‐ANN‐Based Classification Algorithm: An In Vitro Study
Cervical cancer can be detected at an early stage through the changes occurring in biochemical and morphological properties of epithelium layer. Fluorescence spectroscopy has the ability to identify these subtle changes non‐invasively and in real time with good accuracy in comparison with conventional techniques. In this paper, we report the usage of a custom designed spatially resolved fibre‐optic probe (SRFOP), which consists of 77 fibres in two concentric rings, for the detection of cervical cancer using fluorescence spectroscopy technique. The aim of this study is to classify different grades of cervical precancer on the basis of their fluorescence spectra followed by a robust classification algorithm. Fluorescence spectra of 28 cervical tissue samples of different categories have been recorded using six detector fibres of FOP at different spatial locations with the source fibre (SF). A 405 nm laser diode source has been utilised to excite the samples and a USB 4000 Ocean Optics spectrometer to collect the output spectra in the wavelength range 400–700 nm. Principal component analysis (PCA) was applied to the collected spectra to reduce the dimensionality of the data while preserving the most significant features for classification. The first 10 principal components, which captured the majority of the variance in the spectra, were selected as input features for the classification model. Classification was then performed using an artificial neural network (ANN) with a specific architecture, including an input layer, hidden layers, and a softmax activation function in the output layer. Experimental and classification results both demonstrate that proximal fibres (PFs) perform better than distal fibres (DFs) in capturing the discriminatory features present in the epithelium layer of cervical tissue samples as PF collect most of the signal from the epithelium layer. The combined approach of spatially resolved fluorescence spectroscopy and PCA‐ANN classification techniques is able to discriminate different grades of cervical precancer and normal with an average sensitivity, specificity and accuracy of 93.33%, 96.67% and 95.57%, respectively.
- 8 October 2024
- Published by Wiley in Journal of Biophotonics
- Vol. 17 (11) , e202400284
Spatially Resolved Fibre‐Optic Probe for Cervical Precancer Detection Using Fluorescence Spectroscopy and PCA‐ANN‐Based Classification Algorithm: An In Vitro Study
Cervical cancer can be detected at an early stage through the changes occurring in biochemical and morphological properties of epithelium layer. Fluorescence spectroscopy has the ability to identify these subtle changes non‐invasively and in real time with good accuracy in comparison with conventional techniques. In this paper, we report the usage of a custom designed spatially resolved fibre‐optic probe (SRFOP), which consists of 77 fibres in two concentric rings, for the detection of cervical cancer using fluorescence spectroscopy technique. The aim of this study is to classify different grades of cervical precancer on the basis of their fluorescence spectra followed by a robust classification algorithm. Fluorescence spectra of 28 cervical tissue samples of different categories have been recorded using six detector fibres of FOP at different spatial locations with the source fibre (SF). A 405 nm laser diode source has been utilised to excite the samples and a USB 4000 Ocean Optics spectrometer to collect the output spectra in the wavelength range 400–700 nm. Principal component analysis (PCA) was applied to the collected spectra to reduce the dimensionality of the data while preserving the most significant features for classification. The first 10 principal components, which captured the majority of the variance in the spectra, were selected as input features for the classification model. Classification was then performed using an artificial neural network (ANN) with a specific architecture, including an input layer, hidden layers, and a softmax activation function in the output layer. Experimental and classification results both demonstrate that proximal fibres (PFs) perform better than distal fibres (DFs) in capturing the discriminatory features present in the epithelium layer of cervical tissue samples as PF collect most of the signal from the epithelium layer. The combined approach of spatially resolved fluorescence spectroscopy and PCA‐ANN classification techniques is able to discriminate different grades of cervical precancer and normal with an average sensitivity, specificity and accuracy of 93.33%, 96.67% and 95.57%, respectively.
- 6 August 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (16) , 165022
Resolution limits for radiation-induced acoustic imaging for in vivo radiation dosimetry
Objective. Radiation-induced acoustic (RA) computed tomographic (RACT) imaging is being thoroughly explored for radiation dosimetry. It is essential to understand how key machine parameters like beam pulse, size, and energy deposition affect image quality in RACT. We investigate the intricate interplay of these parameters and how these factors influence dose map resolution in RACT. Approach. We first conduct an analytical assessment of time-domain RA signals and their corresponding frequency spectra for certain testcases, and computationally validate these analyses. Subsequently, we simulated a series of x-ray-based RACT (XACT) experiments and compared the simulations with experimental measurements. In-silico reconstruction studies have also been conducted to demonstrate the resolution limits imposed by the temporal pulse profiles on RACT. XACT experiments were performed using clinical machines and the reconstructions were analyzed for resolution capabilities. Main results. Our paper establishes the theory for predicting the time- and frequency-domain behavior of RA signals. We illustrate that the frequency content of RA signal is not solely dependent on the spatial energy deposition characteristics but also on the temporal features of radiation. The same spatial energy deposition through a Gaussian pulse and a rectangular pulse of equal pulsewidths results in different frequency spectra of the RA signals. RA signals corresponding to the rectangular pulse exhibit more high-frequency content than their Gaussian pulse counterparts and hence provide better resolution in the reconstructions. XACT experiments with ∼3.2 us and ∼4 us rectangular radiation pulses were performed, and the reconstruction results were found to correlate well with the in-silico results. Significance. Here, we discuss the inherent resolution limits for RACT-based radiation dosimetric systems. While our study is relevant to the broader community engaged in research on photoacoustics, x-ray-acoustics, and proto/ionoacoustics, it holds particular significance for medical physics researchers aiming to set up RACT for dosimetry and radiography using clinical radiation machines.
- 6 August 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (16) , 165022
Resolution limits for radiation-induced acoustic imaging for in vivo radiation dosimetry
Objective. Radiation-induced acoustic (RA) computed tomographic (RACT) imaging is being thoroughly explored for radiation dosimetry. It is essential to understand how key machine parameters like beam pulse, size, and energy deposition affect image quality in RACT. We investigate the intricate interplay of these parameters and how these factors influence dose map resolution in RACT. Approach. We first conduct an analytical assessment of time-domain RA signals and their corresponding frequency spectra for certain testcases, and computationally validate these analyses. Subsequently, we simulated a series of x-ray-based RACT (XACT) experiments and compared the simulations with experimental measurements. In-silico reconstruction studies have also been conducted to demonstrate the resolution limits imposed by the temporal pulse profiles on RACT. XACT experiments were performed using clinical machines and the reconstructions were analyzed for resolution capabilities. Main results. Our paper establishes the theory for predicting the time- and frequency-domain behavior of RA signals. We illustrate that the frequency content of RA signal is not solely dependent on the spatial energy deposition characteristics but also on the temporal features of radiation. The same spatial energy deposition through a Gaussian pulse and a rectangular pulse of equal pulsewidths results in different frequency spectra of the RA signals. RA signals corresponding to the rectangular pulse exhibit more high-frequency content than their Gaussian pulse counterparts and hence provide better resolution in the reconstructions. XACT experiments with ∼3.2 us and ∼4 us rectangular radiation pulses were performed, and the reconstruction results were found to correlate well with the in-silico results. Significance. Here, we discuss the inherent resolution limits for RACT-based radiation dosimetric systems. While our study is relevant to the broader community engaged in research on photoacoustics, x-ray-acoustics, and proto/ionoacoustics, it holds particular significance for medical physics researchers aiming to set up RACT for dosimetry and radiography using clinical radiation machines.
- 31 May 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (11) , 115053
4D in vivo dosimetry for a FLASH electron beam using radiation-induced acoustic imaging
Objective. The primary goal of this research is to demonstrate the feasibility of radiation-induced acoustic imaging (RAI) as a volumetric dosimetry tool for ultra-high dose rate FLASH electron radiotherapy (FLASH-RT) in real time. This technology aims to improve patient outcomes by accurate measurements of in vivo dose delivery to target tumor volumes. Approach. The study utilized the FLASH-capable eRT6 LINAC to deliver electron beams under various doses (1.2 Gy pulse−1 to 4.95 Gy pulse−1) and instantaneous dose rates (1.55 × 105 Gy s−1 to 2.75 × 106 Gy s−1), for imaging the beam in water and in a rabbit cadaver with RAI. A custom 256-element matrix ultrasound array was employed for real-time, volumetric (4D) imaging of individual pulses. This allowed for the exploration of dose linearity by varying the dose per pulse and analyzing the results through signal processing and image reconstruction in RAI. Main Results. By varying the dose per pulse through changes in source-to-surface distance, a direct correlation was established between the peak-to-peak amplitudes of pressure waves captured by the RAI system and the radiochromic film dose measurements. This correlation demonstrated dose rate linearity, including in the FLASH regime, without any saturation even at an instantaneous dose rate up to 2.75 × 106 Gy s−1. Further, the use of the 2D matrix array enabled 4D tracking of FLASH electron beam dose distributions on animal tissue for the first time. Significance. This research successfully shows that 4D in vivo dosimetry is feasible during FLASH-RT using a RAI system. It allows for precise spatial (∼mm) and temporal (25 frames s−1) monitoring of individual FLASH beamlets during delivery. This advancement is crucial for the clinical translation of FLASH-RT as enhancing the accuracy of dose delivery to the target volume the safety and efficacy of radiotherapeutic procedures will be improved.
- 31 May 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (11) , 115053
4D in vivo dosimetry for a FLASH electron beam using radiation-induced acoustic imaging
Objective. The primary goal of this research is to demonstrate the feasibility of radiation-induced acoustic imaging (RAI) as a volumetric dosimetry tool for ultra-high dose rate FLASH electron radiotherapy (FLASH-RT) in real time. This technology aims to improve patient outcomes by accurate measurements of in vivo dose delivery to target tumor volumes. Approach. The study utilized the FLASH-capable eRT6 LINAC to deliver electron beams under various doses (1.2 Gy pulse−1 to 4.95 Gy pulse−1) and instantaneous dose rates (1.55 × 105 Gy s−1 to 2.75 × 106 Gy s−1), for imaging the beam in water and in a rabbit cadaver with RAI. A custom 256-element matrix ultrasound array was employed for real-time, volumetric (4D) imaging of individual pulses. This allowed for the exploration of dose linearity by varying the dose per pulse and analyzing the results through signal processing and image reconstruction in RAI. Main Results. By varying the dose per pulse through changes in source-to-surface distance, a direct correlation was established between the peak-to-peak amplitudes of pressure waves captured by the RAI system and the radiochromic film dose measurements. This correlation demonstrated dose rate linearity, including in the FLASH regime, without any saturation even at an instantaneous dose rate up to 2.75 × 106 Gy s−1. Further, the use of the 2D matrix array enabled 4D tracking of FLASH electron beam dose distributions on animal tissue for the first time. Significance. This research successfully shows that 4D in vivo dosimetry is feasible during FLASH-RT using a RAI system. It allows for precise spatial (∼mm) and temporal (25 frames s−1) monitoring of individual FLASH beamlets during delivery. This advancement is crucial for the clinical translation of FLASH-RT as enhancing the accuracy of dose delivery to the target volume the safety and efficacy of radiotherapeutic procedures will be improved.
- Open Access
- 29 January 2024
- Published by AIP Publishing in Applied Physics Letters
- Vol. 124 (5) , 053702
Ionic-resolution protoacoustic microscopy: A feasibility study
Visualizing micro- and nano-scale biological entities requires high-resolution imaging and is conventionally achieved via optical microscopic techniques. Optical diffraction limits their resolution to ∼200 nm. This limit can be overcome by using ions with ∼1 MeV energy. Such ions penetrate through several micrometers in tissues, and their much shorter de Broglie wavelengths indicate that these ion beams can be focused to much shorter scales and hence can potentially facilitate higher resolution as compared to the optical techniques. Proton microscopy with ∼1 MeV protons has been shown to have reasonable inherent contrast between sub-cellular organelles. However, being a transmission-based modality, it is unsuitable for in vivo studies and cannot facilitate three-dimensional imaging from a single raster scan. Here, we propose proton-induced acoustic microscopy (PrAM), a technique based on pulsed proton irradiation and proton-induced acoustic signal collection. This technique is capable of label-free, super-resolution, 3D imaging with a single raster scan. Converting radiation energy into ultrasound enables PrAM with reflection mode detection, making it suitable for in vivo imaging and probing deeper than proton scanning transmission ion microscopy (STIM). Using a proton STIM image of HeLa cells, a coupled Monte Carlo+k-wave simulations-based feasibility study has been performed to demonstrate the capabilities of PrAM. We demonstrate that sub-50 nm lateral (depending upon the beam size and energy) and sub-micron axial resolution (based on acoustic detection bandwidth and proton beam pulse width) can be obtained using the proposed modality. By enabling visualization of biological phenomena at cellular and subcellular levels, this high-resolution microscopic technique enhances understanding of intricate cellular processes.
- 29 January 2024
- Published by AIP Publishing in Applied Physics Letters
- Vol. 124 (5) , 053702
Open AccessIonic-resolution protoacoustic microscopy: A feasibility study
Visualizing micro- and nano-scale biological entities requires high-resolution imaging and is conventionally achieved via optical microscopic techniques. Optical diffraction limits their resolution to ∼200 nm. This limit can be overcome by using ions with ∼1 MeV energy. Such ions penetrate through several micrometers in tissues, and their much shorter de Broglie wavelengths indicate that these ion beams can be focused to much shorter scales and hence can potentially facilitate higher resolution as compared to the optical techniques. Proton microscopy with ∼1 MeV protons has been shown to have reasonable inherent contrast between sub-cellular organelles. However, being a transmission-based modality, it is unsuitable for in vivo studies and cannot facilitate three-dimensional imaging from a single raster scan. Here, we propose proton-induced acoustic microscopy (PrAM), a technique based on pulsed proton irradiation and proton-induced acoustic signal collection. This technique is capable of label-free, super-resolution, 3D imaging with a single raster scan. Converting radiation energy into ultrasound enables PrAM with reflection mode detection, making it suitable for in vivo imaging and probing deeper than proton scanning transmission ion microscopy (STIM). Using a proton STIM image of HeLa cells, a coupled Monte Carlo+k-wave simulations-based feasibility study has been performed to demonstrate the capabilities of PrAM. We demonstrate that sub-50 nm lateral (depending upon the beam size and energy) and sub-micron axial resolution (based on acoustic detection bandwidth and proton beam pulse width) can be obtained using the proposed modality. By enabling visualization of biological phenomena at cellular and subcellular levels, this high-resolution microscopic technique enhances understanding of intricate cellular processes.