Zaidon Al-Falahi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Zaidon Al-Falahi has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Martin Ugander
Kolling Institute, Royal North Shore Hospital, and University of Sydney
4 shared publications - Thomas Lindow
Respiratory Medicine, Allergology, and Palliative Medicine, Department of Clinical Sciences Lund, Lund University, Lund, Sweden
3 shared publications - Todd T. Schlegel
Department of Clinical Physiology, Karolinska University Hospital, and Karolinska Institutet
3 shared publications Annie Li
Kolling Institute, Royal North Shore Hospital, University of Sydney, St Leonards, Sydney, NSW 2065, Australia
2 shared publications- Erik B. Schelbert
Allina Health Minneapolis Heart Institute, Abbott Northwestern Hospital, MN (P.S., J.L., E.S., V.B., J.L.C.).
2 shared publications - Louise Niklasson
Minneapolis Heart Institute East, United Hospital , Minneapolis, MN 55407
2 shared publications
Latest Publications
- Open Access
Explainable Advanced Electrocardiography Heart Age Shows Good Reproducibility in Healthy Young Adults
Aims: Explainable advanced electrocardiography (A-ECG) can be used to estimate heart age from the standard 12-lead ECG. A-ECG heart age gap (HAG) represents the difference between A-ECG heart age and chronological age. Increased A-ECG HAG is associated with cardiovascular outcomes and can be used to communicate risk. The aim was to investigate whether A-ECG heart age demonstrates acceptable within- and between-session reproducibility. Methods: Healthy adults (n=42, age 23±4 years, 52% male) attended up to two sessions ~14 days apart, with 36 participants completing both sessions. During each session, five standard resting 12-lead ECGs were obtained while lying in the supine position with unchanged electrode positions. A-ECG heart age was extracted using dedicated software. Within-session reproducibility was assessed using all five recorded ECGs with coefficient of variation (CV) and a two-way random effects intraclass correlation coefficient (ICC). Between-session reproducibility was assessed using the first recorded ECG of each session with a paired t-test, CV and ICC. A further analysis assessed the reproducibility of the parameters used in the A-ECG heart age regression model. Results: A-ECG heart age showed excellent within-session reproducibility in session one and two (both CV 5.8%, ICC 0.99). A-ECG heart age was slightly lower in session one than two (24.0±7.5 vs. 25.5±7.8 years, p=0.04) and showed good between-session reproducibility (CV 8.3%, ICC 0.84). All but one parameter used to estimate A-ECG heart age showed acceptable within- and between-session reproducibility (CV<10%). Conclusion: A-ECG heart age demonstrates excellent within-session reproducibility and good between-session reproducibility in healthy young adults. LAY SUMMARY: This study investigated whether advanced electrocardiography (A-ECG) heart age, an explainable heart age estimate derived from a standard 12-lead ECG, shows acceptable reproducibility when estimated repeatedly in healthy young adults. A-ECG heart age showed excellent within-session reproducibility across five ECGs recorded during each of two sessions approximately 14 days apart, with within-session coefficients of variation (CV) of 5.8%. When comparing the first recorded ECGs from each session, A-ECG heart age offered good between-session reproducibility demonstrating a CV of 8.3%. These findings show that A-ECG heart age is stable under standardised recording conditions in healthy young adults. Graphical
Open AccessExplainable Advanced Electrocardiography Heart Age Shows Good Reproducibility in Healthy Young Adults
Aims: Explainable advanced electrocardiography (A-ECG) can be used to estimate heart age from the standard 12-lead ECG. A-ECG heart age gap (HAG) represents the difference between A-ECG heart age and chronological age. Increased A-ECG HAG is associated with cardiovascular outcomes and can be used to communicate risk. The aim was to investigate whether A-ECG heart age demonstrates acceptable within- and between-session reproducibility. Methods: Healthy adults (n=42, age 23±4 years, 52% male) attended up to two sessions ~14 days apart, with 36 participants completing both sessions. During each session, five standard resting 12-lead ECGs were obtained while lying in the supine position with unchanged electrode positions. A-ECG heart age was extracted using dedicated software. Within-session reproducibility was assessed using all five recorded ECGs with coefficient of variation (CV) and a two-way random effects intraclass correlation coefficient (ICC). Between-session reproducibility was assessed using the first recorded ECG of each session with a paired t-test, CV and ICC. A further analysis assessed the reproducibility of the parameters used in the A-ECG heart age regression model. Results: A-ECG heart age showed excellent within-session reproducibility in session one and two (both CV 5.8%, ICC 0.99). A-ECG heart age was slightly lower in session one than two (24.0±7.5 vs. 25.5±7.8 years, p=0.04) and showed good between-session reproducibility (CV 8.3%, ICC 0.84). All but one parameter used to estimate A-ECG heart age showed acceptable within- and between-session reproducibility (CV<10%). Conclusion: A-ECG heart age demonstrates excellent within-session reproducibility and good between-session reproducibility in healthy young adults. LAY SUMMARY: This study investigated whether advanced electrocardiography (A-ECG) heart age, an explainable heart age estimate derived from a standard 12-lead ECG, shows acceptable reproducibility when estimated repeatedly in healthy young adults. A-ECG heart age showed excellent within-session reproducibility across five ECGs recorded during each of two sessions approximately 14 days apart, with within-session coefficients of variation (CV) of 5.8%. When comparing the first recorded ECGs from each session, A-ECG heart age offered good between-session reproducibility demonstrating a CV of 8.3%. These findings show that A-ECG heart age is stable under standardised recording conditions in healthy young adults. Graphical
- Open Access
Study protocol for The Heart Watch Study - Prognostic performance of smartwatch 12-lead ECG with advanced ECG analysis in consumer self-screening for cardiovascular disease
Background: It is now possible to acquire a fully diagnostic standard 12-lead electrocardiography (ECG) using a smartwatch, a smartphone app, and no additional hardware. This study aims to evaluate the predictive performance of advanced ECG (A-ECG) analysis applied to a smartwatch 12-lead ECG (SWECG) acquired using an Apple Watch in identifying cardiovascular risks among asymptomatic adults performing consumer self-screening in the general population. Methods and Design: The Heart Watch Study is a prospective, Australia-wide observational cohort study. The study will recruit 30,000 participants aged 20-79 years without prior known cardiovascular disease. Participants will enrol and consent electronically, and download a dedicated study iPhone app that enables a directed 12-lead SWECG acquisition using an Apple Watch. The recordings will undergo both conventional and A-ECG analysis. Follow-up will be performed through linkage with administrative health datasets in Australia, including hospital visits and mortality. The primary combined endpoint is all-cause mortality, hospitalization for cardiovascular causes, and incident cardiovascular disease (arrythmia, ischemic heart disease, heart failure) as predicted by existing A-ECG analyses. Conclusion: This study evaluates the feasibility of performing a fully diagnostic standard 12-lead SWECG using only a smartwatch and a smartphone application, and addresses the prognostic value of A-ECG machine-learning based analysis in consumer self-screening in a large, diverse and apparently healthy population.
Open AccessStudy protocol for The Heart Watch Study - Prognostic performance of smartwatch 12-lead ECG with advanced ECG analysis in consumer self-screening for cardiovascular disease
Background: It is now possible to acquire a fully diagnostic standard 12-lead electrocardiography (ECG) using a smartwatch, a smartphone app, and no additional hardware. This study aims to evaluate the predictive performance of advanced ECG (A-ECG) analysis applied to a smartwatch 12-lead ECG (SWECG) acquired using an Apple Watch in identifying cardiovascular risks among asymptomatic adults performing consumer self-screening in the general population. Methods and Design: The Heart Watch Study is a prospective, Australia-wide observational cohort study. The study will recruit 30,000 participants aged 20-79 years without prior known cardiovascular disease. Participants will enrol and consent electronically, and download a dedicated study iPhone app that enables a directed 12-lead SWECG acquisition using an Apple Watch. The recordings will undergo both conventional and A-ECG analysis. Follow-up will be performed through linkage with administrative health datasets in Australia, including hospital visits and mortality. The primary combined endpoint is all-cause mortality, hospitalization for cardiovascular causes, and incident cardiovascular disease (arrythmia, ischemic heart disease, heart failure) as predicted by existing A-ECG analyses. Conclusion: This study evaluates the feasibility of performing a fully diagnostic standard 12-lead SWECG using only a smartwatch and a smartphone application, and addresses the prognostic value of A-ECG machine-learning based analysis in consumer self-screening in a large, diverse and apparently healthy population.
- Open Access
- 9 October 2024
- Published by Oxford University Press (OUP) in European Heart Journal - Digital Health
- Vol. 6 (1) , 45-54
Advanced electrocardiography heart age: a prognostic, explainable machine learning approach applicable to sinus and non-sinus rhythms
An explainable advanced electrocardiography (A-ECG) Heart Age gap is the difference between A-ECG Heart Age and chronological age. This gap is an estimate of accelerated cardiovascular ageing expressed in years of healthy human aging, and can intuitively communicate cardiovascular risk to the general population. However, existing A-ECG Heart Age requires sinus rhythm. To develop and prognostically validate a revised, explainable A-ECG Heart Age applicable to both sinus and non-sinus rhythms. An A-ECG Heart Age excluding P-wave measures was derived from the 10-second 12-lead ECG in a derivation cohort using multivariable regression machine learning with Bayesian 5-minute 12-lead A-ECG Heart Age as reference. The Heart Age was externally validated in a separate cohort of patients referred for cardiovascular magnetic resonance imaging by describing its association with heart failure hospitalization or death using Cox regression, and its association with comorbidities. In the derivation cohort (n=2771), A-ECG Heart Age agreed with the 5-min Heart Age (R2=0.91, bias 0.0±6.7 years), and increased with increasing co-morbidity. In the validation cohort (n=731, mean age 54±15 years, 43% female, n=139 events over 5.7 [4.8–6.7] years follow-up), increased A-ECG Heart Age gap (≥10 years) associated with events (hazard ratio [95% confidence interval] 2.04 [1.38–3.00], C-statistic 0.58 [0.54–0.62], and the presence of hypertension, diabetes mellitus, hypercholesterolemia, and heart failure (p≤0.009 for all). An explainable A-ECG Heart Age gap applicable to both sinus and non-sinus rhythm associates with cardiovascular risk, cardiovascular morbidity, and survival.
- 9 October 2024
- Published by Oxford University Press (OUP) in European Heart Journal - Digital Health
- Vol. 6 (1) , 45-54
Open AccessAdvanced electrocardiography heart age: a prognostic, explainable machine learning approach applicable to sinus and non-sinus rhythms
An explainable advanced electrocardiography (A-ECG) Heart Age gap is the difference between A-ECG Heart Age and chronological age. This gap is an estimate of accelerated cardiovascular ageing expressed in years of healthy human aging, and can intuitively communicate cardiovascular risk to the general population. However, existing A-ECG Heart Age requires sinus rhythm. To develop and prognostically validate a revised, explainable A-ECG Heart Age applicable to both sinus and non-sinus rhythms. An A-ECG Heart Age excluding P-wave measures was derived from the 10-second 12-lead ECG in a derivation cohort using multivariable regression machine learning with Bayesian 5-minute 12-lead A-ECG Heart Age as reference. The Heart Age was externally validated in a separate cohort of patients referred for cardiovascular magnetic resonance imaging by describing its association with heart failure hospitalization or death using Cox regression, and its association with comorbidities. In the derivation cohort (n=2771), A-ECG Heart Age agreed with the 5-min Heart Age (R2=0.91, bias 0.0±6.7 years), and increased with increasing co-morbidity. In the validation cohort (n=731, mean age 54±15 years, 43% female, n=139 events over 5.7 [4.8–6.7] years follow-up), increased A-ECG Heart Age gap (≥10 years) associated with events (hazard ratio [95% confidence interval] 2.04 [1.38–3.00], C-statistic 0.58 [0.54–0.62], and the presence of hypertension, diabetes mellitus, hypercholesterolemia, and heart failure (p≤0.009 for all). An explainable A-ECG Heart Age gap applicable to both sinus and non-sinus rhythm associates with cardiovascular risk, cardiovascular morbidity, and survival.
- Open Access
Advanced ECG heart age estimation applicable to both sinus and non-sinus rhythm associates with cardiovascular risk, cardiovascular morbidity, and survival
Background: An explainable advanced electrocardiography (A-ECG) heart age gap is the difference between A-ECG heart age and chronological age. This gap is an estimate of accelerated cardiovascular ageing expressed in years of healthy human aging, and can intuitively communicate cardiovascular risk to the general population. However, existing A-ECG heart age measures require discernible P waves on the ECG. Aims: To develop and prognostically validate a revised, explainable A-ECG heart age gap without incorporating P-wave measures. Methods: An A-ECG heart age without P-wave measures (non-P) was derived from the 10-second 12-lead ECG in a derivation cohort using multivariable regression using an existing Bayesian 5-minute 12-lead A-ECG heart age as reference. The non-P heart age was externally validated in a separate cohort of patients referred for cardiovascular magnetic resonance imaging by describing its association with heart failure hospitalization or death using Cox regression, and its association with comorbidities. Results: In the derivation cohort (n=2771), A-ECG non-P heart age agreed with the 5-min heart age (R 2 =0.91, bias 0.0±6.7 years), and increased with increasing co-morbidity. In the validation cohort (n=731, mean age 54±15 years, 43% female, n=139 events over 5.7 [4.8–6.7] years follow-up), increased A-ECG non-P heart age gap (≥10 years) associated with events (hazard ratio [95% confidence interval] 2.04 [1.38–3.00], C-statistic 0.58 [0.54–0.62], and the presence of hypertension, diabetes mellitus, hypercholesterolemia, and heart failure (p≤0.009 for all). Conclusions: An explainable A-ECG non-P heart age gap applicable to both sinus and non-sinus rhythm associates with cardiovascular risk, cardiovascular morbidity, and survival.
Open AccessAdvanced ECG heart age estimation applicable to both sinus and non-sinus rhythm associates with cardiovascular risk, cardiovascular morbidity, and survival
Background: An explainable advanced electrocardiography (A-ECG) heart age gap is the difference between A-ECG heart age and chronological age. This gap is an estimate of accelerated cardiovascular ageing expressed in years of healthy human aging, and can intuitively communicate cardiovascular risk to the general population. However, existing A-ECG heart age measures require discernible P waves on the ECG. Aims: To develop and prognostically validate a revised, explainable A-ECG heart age gap without incorporating P-wave measures. Methods: An A-ECG heart age without P-wave measures (non-P) was derived from the 10-second 12-lead ECG in a derivation cohort using multivariable regression using an existing Bayesian 5-minute 12-lead A-ECG heart age as reference. The non-P heart age was externally validated in a separate cohort of patients referred for cardiovascular magnetic resonance imaging by describing its association with heart failure hospitalization or death using Cox regression, and its association with comorbidities. Results: In the derivation cohort (n=2771), A-ECG non-P heart age agreed with the 5-min heart age (R 2 =0.91, bias 0.0±6.7 years), and increased with increasing co-morbidity. In the validation cohort (n=731, mean age 54±15 years, 43% female, n=139 events over 5.7 [4.8–6.7] years follow-up), increased A-ECG non-P heart age gap (≥10 years) associated with events (hazard ratio [95% confidence interval] 2.04 [1.38–3.00], C-statistic 0.58 [0.54–0.62], and the presence of hypertension, diabetes mellitus, hypercholesterolemia, and heart failure (p≤0.009 for all). Conclusions: An explainable A-ECG non-P heart age gap applicable to both sinus and non-sinus rhythm associates with cardiovascular risk, cardiovascular morbidity, and survival.
- Open Access
Personalised Cardiac Rehabilitation Outreach Service Reduces Mortality and Hospitalisations in Heart Failure with Reduced Ejection Fraction
Background: Heart failure (HF) has become a major cause of morbidity and mortality worldwide. Despite significant improvements in the management of HF, the overall outcomes remain poor. In addition to pharmacotherapy and device therapy, non-pharmacological interventions are needed to mitigate the effects of this illness. The aim of this study was to evaluate the impact of the heart failure outreach program on the rate of mortality, HF hospitalisations and guideline directed medical therapy (GDMT) for HF in South Western Sydney Local Health District (SWSLHD). Methods: In this observational, registry based study, adult patients diagnosed with Heart failure with reduced ejection fraction (HFrEF) within the South Western Sydney Local Health District (SWSLHD) and invited to participate in the heart failure outreach service between March 2011 and January 2016 were included in the study. The primary outcome was all-cause mortality. In addition, we examined the rate of optimal medical therapy, HF hospitalisations and the total lengths of stay. Results: A total of 818 patients were included in the study; 470 (57.5%) patients were enrolled and 348 (42.5 %) not enrolled into the program. At the end of the follow up period (median 978 days, interquartile range (IQR) 720-1237), the primary outcome of mortality was observed significantly less in the enrolled group (122 (26%) vs. 133 (38.2%), p3 hospital admissions for HF (16.2% vs. 35.6%, p<0.001) and reduced median admission days (14.5 days [IQR 8-25] vs 22 [IQR 12-37], p <0.001). Patients enrolled into the program were much more likely to be on GDMT (76.6% vs 56.6%, p<0.001). Conclusions: Enrolment in the heart failure outreach program was associated with a significant reduction in mortality as well as a reduction in the frequency and length of hospital admissions. In addition, the rate of GDMT was significantly higher in the enrolled group. With the high prevalence of heart failure, these programs should be considered in the routine management of patients with HFrEF.
Open AccessPersonalised Cardiac Rehabilitation Outreach Service Reduces Mortality and Hospitalisations in Heart Failure with Reduced Ejection Fraction
Background: Heart failure (HF) has become a major cause of morbidity and mortality worldwide. Despite significant improvements in the management of HF, the overall outcomes remain poor. In addition to pharmacotherapy and device therapy, non-pharmacological interventions are needed to mitigate the effects of this illness. The aim of this study was to evaluate the impact of the heart failure outreach program on the rate of mortality, HF hospitalisations and guideline directed medical therapy (GDMT) for HF in South Western Sydney Local Health District (SWSLHD). Methods: In this observational, registry based study, adult patients diagnosed with Heart failure with reduced ejection fraction (HFrEF) within the South Western Sydney Local Health District (SWSLHD) and invited to participate in the heart failure outreach service between March 2011 and January 2016 were included in the study. The primary outcome was all-cause mortality. In addition, we examined the rate of optimal medical therapy, HF hospitalisations and the total lengths of stay. Results: A total of 818 patients were included in the study; 470 (57.5%) patients were enrolled and 348 (42.5 %) not enrolled into the program. At the end of the follow up period (median 978 days, interquartile range (IQR) 720-1237), the primary outcome of mortality was observed significantly less in the enrolled group (122 (26%) vs. 133 (38.2%), p3 hospital admissions for HF (16.2% vs. 35.6%, p<0.001) and reduced median admission days (14.5 days [IQR 8-25] vs 22 [IQR 12-37], p <0.001). Patients enrolled into the program were much more likely to be on GDMT (76.6% vs 56.6%, p<0.001). Conclusions: Enrolment in the heart failure outreach program was associated with a significant reduction in mortality as well as a reduction in the frequency and length of hospital admissions. In addition, the rate of GDMT was significantly higher in the enrolled group. With the high prevalence of heart failure, these programs should be considered in the routine management of patients with HFrEF.
- Open Access
- 8 November 2020
- Published by Elsevier in Heart, Lung and Circulation
- Vol. 29, S141
238 Nivolumab Induced Myocarditis, a Recurrent Theme
- 8 November 2020
- Published by Elsevier in Heart, Lung and Circulation
- Vol. 29, S141
Open Access238 Nivolumab Induced Myocarditis, a Recurrent Theme
- 3 June 2017
- Published by Elsevier in Heart, Lung and Circulation
- Vol. 26 (9) , 902-910
Atrial Fibrillation and Sleep Apnoea: Guilt by Association?
- 3 June 2017
- Published by Elsevier in Heart, Lung and Circulation
- Vol. 26 (9) , 902-910
Atrial Fibrillation and Sleep Apnoea: Guilt by Association?