Jinghui Wang
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jinghui Wang has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
- Kun Zhu
State Key Laboratory of Nuclear Physics and Technology, School of Physics, Peking University, Beijing 100871, China
2 shared publications Qiheng Li
Guangdong Institute of Laser Plasma Accelerator Technology
2 shared publicationsRebecca Fahrig
Pattern Recognition Lab, Friedrich-Alexander-University, Erlangen, Germany
2 shared publicationsWei Gai
Guangdong Institute of Laser Plasma Accelerator Technology
2 shared publications- Billy W. Loo
Department of Radiation Oncology, Stanford University School of Medicine, Stanford, CA
1 shared publication Bin Liu
Guangdong Institute of Laser Plasma Accelerator Technology
1 shared publication
Latest Publications
- 24 September 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (18) , 185009
Intracavitary electron radiotherapy with dynamic shielding for rectal cancer: applicator design and dosimetric characterization
Objective. Intensity-modulated brachytherapy can improve dose conformity for rectal cancer, but current 192 Ir-based systems are limited by isotropic photon emission, sequential shield motion, treatment-time penalties, and radioisotope logistics. This study designed, optimized, and characterized a dynamically shielded applicator-based intracavitary electron radiotherapy system intended to improve dose localization and enable ultra-high dose-rate (HDR) delivery without a radioactive source. Approach. A cylindrical electron-beam applicator was designed with a high-density shield containing an emission window, a low- Z scatterer, and a polycarbonate guide tube. Applicator geometry was optimized using TOPAS Monte Carlo simulations to minimize radial and distal transmission factors (TF radial and TF distal ). Dosimetric performance was benchmarked against a modified Monte Carlo model based on a commercial 192 Ir shielded rectal applicator (Varian GM11004160). A 3D-printed prototype with a stainless-steel shield and resin components was experimentally evaluated using a custom linear accelerator (5 MeV nominal energy, 60 mA peak current, 4 μ s pulse width). Dose distributions were measured with EBT-XD radiochromic film. Main results. In the modeled homogeneous benchmark geometry, the optimized tungsten applicator achieved a radial transmission factor of approximately 1% at 10 mm from the applicator surface, compared with approximately 20% for the modeled 192 Ir reference system. Distal leakage remained below 5% beyond the applicator distal end. Under modeled accelerator conditions, the electron-beam system reached approximately 100 Gy s −1 at 100 Hz. Superposition of single-dwell dose kernels produced both uniform fields and spatially fractionated radiotherapy patterns with valley-to-peak dose ratios ⩽ 0.2. Prototype measurements demonstrated localized directional dose delivery and ultra-high mean dose rates under the reported pulse conditions, while identifying leakage pathways that caused order-of-magnitude differences from simulation. Significance. The optimized Monte Carlo model demonstrated improved radial dose localization,radioisotope-free operation, and ultra-HDR capability in homogeneous geometry. Further work is needed for accelerator integration, motion control, inverse planning, and validation in anatomically realistic settings.
- 24 September 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (18) , 185009
Intracavitary electron radiotherapy with dynamic shielding for rectal cancer: applicator design and dosimetric characterization
Objective. Intensity-modulated brachytherapy can improve dose conformity for rectal cancer, but current 192 Ir-based systems are limited by isotropic photon emission, sequential shield motion, treatment-time penalties, and radioisotope logistics. This study designed, optimized, and characterized a dynamically shielded applicator-based intracavitary electron radiotherapy system intended to improve dose localization and enable ultra-high dose-rate (HDR) delivery without a radioactive source. Approach. A cylindrical electron-beam applicator was designed with a high-density shield containing an emission window, a low- Z scatterer, and a polycarbonate guide tube. Applicator geometry was optimized using TOPAS Monte Carlo simulations to minimize radial and distal transmission factors (TF radial and TF distal ). Dosimetric performance was benchmarked against a modified Monte Carlo model based on a commercial 192 Ir shielded rectal applicator (Varian GM11004160). A 3D-printed prototype with a stainless-steel shield and resin components was experimentally evaluated using a custom linear accelerator (5 MeV nominal energy, 60 mA peak current, 4 μ s pulse width). Dose distributions were measured with EBT-XD radiochromic film. Main results. In the modeled homogeneous benchmark geometry, the optimized tungsten applicator achieved a radial transmission factor of approximately 1% at 10 mm from the applicator surface, compared with approximately 20% for the modeled 192 Ir reference system. Distal leakage remained below 5% beyond the applicator distal end. Under modeled accelerator conditions, the electron-beam system reached approximately 100 Gy s −1 at 100 Hz. Superposition of single-dwell dose kernels produced both uniform fields and spatially fractionated radiotherapy patterns with valley-to-peak dose ratios ⩽ 0.2. Prototype measurements demonstrated localized directional dose delivery and ultra-high mean dose rates under the reported pulse conditions, while identifying leakage pathways that caused order-of-magnitude differences from simulation. Significance. The optimized Monte Carlo model demonstrated improved radial dose localization,radioisotope-free operation, and ultra-HDR capability in homogeneous geometry. Further work is needed for accelerator integration, motion control, inverse planning, and validation in anatomically realistic settings.
- 30 June 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (13) , 135001
Development and characterization of a 1–2 MeV electron beam platform with magnetic focusing and steering for shallow high-dose-rate irradiation
Objective. To develop and experimentally characterize a 1–2 MeV electron linac platform with magnetic focusing and steering for superficial FLASH-compatible irradiation and electronically tunable spatial dose modulation. Approach. A preclinical 1–2 MeV electron linac was equipped with a solenoid for magnetic focusing and nested saddle-type scanning magnets for two-dimensional beam steering. Three-dimensional magnetic-field maps were computed in Opera and imported into a TOPAS Monte Carlo (MC) model incorporating the accelerator geometry, titanium exit foil, air gap, and water phantom for dose scoring. Dose distributions were measured using Gafchromic EBT-XD film. Film measurements of spot size, lateral dose profiles, and percentage depth-dose curves were compared with MC simulations. Multi-spot dose patterns were generated by varying scanning-magnet field strength, and peak spacing, peak-to-valley dose ratio, and dose rate as a function of repetition frequency were quantified. Main Results. In the solenoid-focused configuration, the beam size at the 80% isodose diameter was reduced from approximately 6 cm without solenoid focusing to 2 cm, and the measured dose rate reached 125 Gy s − 1 at 50 Hz. The measured full-width-at-half-maximum of the focused beam was 1.26 cm in the X direction and 1.39 cm in the Y direction, and the TOPAS model agreed with EBT-XD film measurements to within about 4% in the high-dose region. Magnetic steering generated tunable three-spot shallow dose distributions with peak-to-peak spacing up to approximately 2.9 cm and a maximum peak-to-valley dose ratio of 28.0. By superposition of adjacent scanned beam positions, the system also produced a broadened shallow field with a 95% D max flat-top width of 2.46 cm. Significance. The results demonstrate that a compact low-energy electron linac can provide a useful platform for studying FLASH-compatible superficial irradiation and electronically controlled spatial dose modulation in a regime where shallow dose confinement is advantageous.
- 30 June 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (13) , 135001
Development and characterization of a 1–2 MeV electron beam platform with magnetic focusing and steering for shallow high-dose-rate irradiation
Objective. To develop and experimentally characterize a 1–2 MeV electron linac platform with magnetic focusing and steering for superficial FLASH-compatible irradiation and electronically tunable spatial dose modulation. Approach. A preclinical 1–2 MeV electron linac was equipped with a solenoid for magnetic focusing and nested saddle-type scanning magnets for two-dimensional beam steering. Three-dimensional magnetic-field maps were computed in Opera and imported into a TOPAS Monte Carlo (MC) model incorporating the accelerator geometry, titanium exit foil, air gap, and water phantom for dose scoring. Dose distributions were measured using Gafchromic EBT-XD film. Film measurements of spot size, lateral dose profiles, and percentage depth-dose curves were compared with MC simulations. Multi-spot dose patterns were generated by varying scanning-magnet field strength, and peak spacing, peak-to-valley dose ratio, and dose rate as a function of repetition frequency were quantified. Main Results. In the solenoid-focused configuration, the beam size at the 80% isodose diameter was reduced from approximately 6 cm without solenoid focusing to 2 cm, and the measured dose rate reached 125 Gy s − 1 at 50 Hz. The measured full-width-at-half-maximum of the focused beam was 1.26 cm in the X direction and 1.39 cm in the Y direction, and the TOPAS model agreed with EBT-XD film measurements to within about 4% in the high-dose region. Magnetic steering generated tunable three-spot shallow dose distributions with peak-to-peak spacing up to approximately 2.9 cm and a maximum peak-to-valley dose ratio of 28.0. By superposition of adjacent scanned beam positions, the system also produced a broadened shallow field with a 95% D max flat-top width of 2.46 cm. Significance. The results demonstrate that a compact low-energy electron linac can provide a useful platform for studying FLASH-compatible superficial irradiation and electronically controlled spatial dose modulation in a regime where shallow dose confinement is advantageous.
- 2 September 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (18)
Geometry-optimized electron beam scattering foils enabling dose uniformity and dose rate enhancement for FLASH radiotherapy studies
Objective: The development of FLASH radiotherapy (FLASH-RT) is limited by the availability of ultra-high dose rate (UHDR) irradiation platform. This study aims to optimize electron scattering foils (SFs) for a compact 6 MeV linear accelerator (linac) operating at a short source-to-surface distance (SSD), enabling lateral uniform dose delivery with UHDR for FLASH-RT studies. Approach: Based on a custom-built linac, optimized aluminum SFs were designed using the Nelder-Mead simplex algorithm coupled with Geant4 Monte-Carlo simulations to achieve lateral dose uniformity in 10 mm of water/PMMA below the surface at a reduced SSD. Two geometric optimization strategies, namely stacked-layer structure and ring structure, were utilized for different field sizes. Dose distributions were quantified using radiochromic EBT-3 films, while the operation parameters—electron-gun anode voltage, pulse width, and pulse frequency—were modulated to explore dose rate dependencies. Main Results: Utilizing an optimized stacked-layer SF and a 4 cm diameter resin collimator, uniform integrated lateral dose profiles in the first 10 mm of PMMA (flatness <5%) were measured for a 3.5 cm diameter field at 11 cm SSD. By modulating the operation parameters including anode voltage, pulse width and frequency, dose-per-pulse was continuously adjustable from 0.09 to 8.37 Gy, yielding instantaneous dose rates of 4.25×10^4 to 2.09×10^6 Gy/s and the mean dose rates spanning from 10^(-2) to 10^3 Gy/s. Simulations further demonstrated that a flatness <5% was achievable for fields up to 10 cm diameter at the same SSD when using the ring structure SFs combined with large-diameter collimators. Significance: The system’s capability to operate across conventional and UHDR regimes within a single framework supports comparisons of conventional radiotherapy and FLASH-RT effects with minimized systematic errors. This work offers insights into SF design methodology and facilitates incremental refinements of UHDR irradiation parameters, findings applicable to develop compact FLASH platforms based on other electron beam systems.
- 2 September 2025
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 70 (18)
Geometry-optimized electron beam scattering foils enabling dose uniformity and dose rate enhancement for FLASH radiotherapy studies
Objective: The development of FLASH radiotherapy (FLASH-RT) is limited by the availability of ultra-high dose rate (UHDR) irradiation platform. This study aims to optimize electron scattering foils (SFs) for a compact 6 MeV linear accelerator (linac) operating at a short source-to-surface distance (SSD), enabling lateral uniform dose delivery with UHDR for FLASH-RT studies. Approach: Based on a custom-built linac, optimized aluminum SFs were designed using the Nelder-Mead simplex algorithm coupled with Geant4 Monte-Carlo simulations to achieve lateral dose uniformity in 10 mm of water/PMMA below the surface at a reduced SSD. Two geometric optimization strategies, namely stacked-layer structure and ring structure, were utilized for different field sizes. Dose distributions were quantified using radiochromic EBT-3 films, while the operation parameters—electron-gun anode voltage, pulse width, and pulse frequency—were modulated to explore dose rate dependencies. Main Results: Utilizing an optimized stacked-layer SF and a 4 cm diameter resin collimator, uniform integrated lateral dose profiles in the first 10 mm of PMMA (flatness <5%) were measured for a 3.5 cm diameter field at 11 cm SSD. By modulating the operation parameters including anode voltage, pulse width and frequency, dose-per-pulse was continuously adjustable from 0.09 to 8.37 Gy, yielding instantaneous dose rates of 4.25×10^4 to 2.09×10^6 Gy/s and the mean dose rates spanning from 10^(-2) to 10^3 Gy/s. Simulations further demonstrated that a flatness <5% was achievable for fields up to 10 cm diameter at the same SSD when using the ring structure SFs combined with large-diameter collimators. Significance: The system’s capability to operate across conventional and UHDR regimes within a single framework supports comparisons of conventional radiotherapy and FLASH-RT effects with minimized systematic errors. This work offers insights into SF design methodology and facilitates incremental refinements of UHDR irradiation parameters, findings applicable to develop compact FLASH platforms based on other electron beam systems.
- Open Access
- 1 June 2019
- Published by AIP Publishing in Applied Physics Reviews
- Vol. 6 (2) , 029902
Erratum: “Review of using gallium nitride for ionizing radiation detection” [Appl. Phys. Rev. 2, 031102 (2015)]
- 1 June 2019
- Published by AIP Publishing in Applied Physics Reviews
- Vol. 6 (2) , 029902
Open AccessErratum: “Review of using gallium nitride for ionizing radiation detection” [Appl. Phys. Rev. 2, 031102 (2015)]
- 15 May 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 66 (6) , 960-968
Pulse Pileup Analysis for a Double-Sided Silicon Strip Detector Using Variable Pulse Shapes
Due to pulse pileup, photon counting detectors (PCDs) suffer from count loss and energy distortion when operating in high count rate environments. In this paper, we studied the pulse pileup of a double-sided silicon strip detector (DSSSD) to evaluate its potential application in a mammography system. We analyzed the pulse pileup using pulses of varied shapes, where the shape of the pulse depends on the location of photon interaction within the detector. To obtain the shaped pulses, first, transient currents for photons interacting at different locations were simulated using a Technology Computer-Aided Design (TCAD) software. Next, the currents were shaped by a CR- RC 2 shaping circuit, calculated using Simulink. After obtaining these pulses, both the different orders of pileup and the energy spectrum were calculated by taking into account the following two factors: 1) spatial distribution of photon interactions within the detector and 2) time interval distribution between successive photons under a given photon flux. We found that for a DSSSD with a thickness of 300 μm, a pitch of 25 μm, and a strip length of 1 cm, under a bias voltage of 50 V, the variable pulse shape model predicts that the fraction free of pileup can be >90% under a photon flux of 3.75 Mcps/mm 2 (million counts per second per square mm). The DSSSD is a promising candidate for digital mammography applications.
- 15 May 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Nuclear Science
- Vol. 66 (6) , 960-968
Pulse Pileup Analysis for a Double-Sided Silicon Strip Detector Using Variable Pulse Shapes
Due to pulse pileup, photon counting detectors (PCDs) suffer from count loss and energy distortion when operating in high count rate environments. In this paper, we studied the pulse pileup of a double-sided silicon strip detector (DSSSD) to evaluate its potential application in a mammography system. We analyzed the pulse pileup using pulses of varied shapes, where the shape of the pulse depends on the location of photon interaction within the detector. To obtain the shaped pulses, first, transient currents for photons interacting at different locations were simulated using a Technology Computer-Aided Design (TCAD) software. Next, the currents were shaped by a CR- RC 2 shaping circuit, calculated using Simulink. After obtaining these pulses, both the different orders of pileup and the energy spectrum were calculated by taking into account the following two factors: 1) spatial distribution of photon interactions within the detector and 2) time interval distribution between successive photons under a given photon flux. We found that for a DSSSD with a thickness of 300 μm, a pitch of 25 μm, and a strip length of 1 cm, under a bias voltage of 50 V, the variable pulse shape model predicts that the fraction free of pileup can be >90% under a photon flux of 3.75 Mcps/mm 2 (million counts per second per square mm). The DSSSD is a promising candidate for digital mammography applications.
- 6 October 2017
- Published by Wiley in Medical Physics
- Vol. 44 (12) , 6610-6620
Thermal limits on MV x‐ray production by bremsstrahlung targets in the context of novel linear accelerators
Purpose: To study the impact of target geometrical and linac operational parameters, such as target material and thickness, electron beam size, repetition rate, and mean current on the ability of the radiotherapy treatment head to deliver high‐dose‐rate x‐ray irradiation in the context of novel linear accelerators capable of higher repetition rates/duty cycle than conventional clinical linacs.Methods: The depth dose in a water phantom without a flattening filter and heat deposition in an x‐ray target by 10 MeV pulsed electron beams were calculated using the Monte‐Carlo code MCNPX, and the transient temperature behavior of the target was simulated by ANSYS. Several parameters that affect both the dose distribution and temperature behavior were investigated. The target was tungsten with a thickness ranging from 0 to 3 mm and a copper heat remover layer. An electron beam with full width at half maximum (FWHM) between 0 and3 mm and mean current of 0.05–2 mA was used as the primary beam at repetition rates of 100, 200, 400, and 800 Hz.Results: For a 10 MeV electron beam with FWHM of 1 mm, pulse length of 5 μs, by using a thin tungsten target with thickness of 0.2 mm instead of 1 mm, and by employing a high repetition rate of 800 Hz instead of 100 Hz, the maximum dose rate delivered can increase two times from 0.57 to 1.16 Gy/s. In this simple model, the limiting factor on dose rate is the copper heat remover's softening temperature, which was considered to be 500°C in our study.Conclusions: A high dose rate can be obtained by employing thin targets together with high repetition rate electron beams enabled by novel linac designs, whereas the benefit of thin targets is marginal at conventional repetition rates. Next generation linacs used to increase dose rate need different target designs compared to conventional linacs.
- 6 October 2017
- Published by Wiley in Medical Physics
- Vol. 44 (12) , 6610-6620
Thermal limits on MV x‐ray production by bremsstrahlung targets in the context of novel linear accelerators
Purpose: To study the impact of target geometrical and linac operational parameters, such as target material and thickness, electron beam size, repetition rate, and mean current on the ability of the radiotherapy treatment head to deliver high‐dose‐rate x‐ray irradiation in the context of novel linear accelerators capable of higher repetition rates/duty cycle than conventional clinical linacs.Methods: The depth dose in a water phantom without a flattening filter and heat deposition in an x‐ray target by 10 MeV pulsed electron beams were calculated using the Monte‐Carlo code MCNPX, and the transient temperature behavior of the target was simulated by ANSYS. Several parameters that affect both the dose distribution and temperature behavior were investigated. The target was tungsten with a thickness ranging from 0 to 3 mm and a copper heat remover layer. An electron beam with full width at half maximum (FWHM) between 0 and3 mm and mean current of 0.05–2 mA was used as the primary beam at repetition rates of 100, 200, 400, and 800 Hz.Results: For a 10 MeV electron beam with FWHM of 1 mm, pulse length of 5 μs, by using a thin tungsten target with thickness of 0.2 mm instead of 1 mm, and by employing a high repetition rate of 800 Hz instead of 100 Hz, the maximum dose rate delivered can increase two times from 0.57 to 1.16 Gy/s. In this simple model, the limiting factor on dose rate is the copper heat remover's softening temperature, which was considered to be 500°C in our study.Conclusions: A high dose rate can be obtained by employing thin targets together with high repetition rate electron beams enabled by novel linac designs, whereas the benefit of thin targets is marginal at conventional repetition rates. Next generation linacs used to increase dose rate need different target designs compared to conventional linacs.