Development and characterization of a 1–2 MeV electron beam platform with magnetic focusing and steering for shallow high-dose-rate irradiation
- 30 June 2026
- journal article
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (13) , 135001
Abstract
Objective. To develop and experimentally characterize a 1–2 MeV electron linac platform with magnetic focusing and steering for superficial FLASH-compatible irradiation and electronically tunable spatial dose modulation. Approach. A preclinical 1–2 MeV electron linac was equipped with a solenoid for magnetic focusing and nested saddle-type scanning magnets for two-dimensional beam steering. Three-dimensional magnetic-field maps were computed in Opera and imported into a TOPAS Monte Carlo (MC) model incorporating the accelerator geometry, titanium exit foil, air gap, and water phantom for dose scoring. Dose distributions were measured using Gafchromic EBT-XD film. Film measurements of spot size, lateral dose profiles, and percentage depth-dose curves were compared with MC simulations. Multi-spot dose patterns were generated by varying scanning-magnet field strength, and peak spacing, peak-to-valley dose ratio, and dose rate as a function of repetition frequency were quantified. Main Results. In the solenoid-focused configuration, the beam size at the 80% isodose diameter was reduced from approximately 6 cm without solenoid focusing to 2 cm, and the measured dose rate reached 125 Gy s − 1 at 50 Hz. The measured full-width-at-half-maximum of the focused beam was 1.26 cm in the X direction and 1.39 cm in the Y direction, and the TOPAS model agreed with EBT-XD film measurements to within about 4% in the high-dose region. Magnetic steering generated tunable three-spot shallow dose distributions with peak-to-peak spacing up to approximately 2.9 cm and a maximum peak-to-valley dose ratio of 28.0. By superposition of adjacent scanned beam positions, the system also produced a broadened shallow field with a 95% D max flat-top width of 2.46 cm. Significance. The results demonstrate that a compact low-energy electron linac can provide a useful platform for studying FLASH-compatible superficial irradiation and electronically controlled spatial dose modulation in a regime where shallow dose confinement is advantageous.Keywords
Funding Information
- Science and Technology Planning Project of Shenzen Municipality (JCYJ20190813153403633)
- Guangdong Provincial Key Laboratory of Advanced Particle Detection Technology (2024B1212010005)
- Guangdong Provincial Key Laboratory of Gamma-Gamma Collider and Its Comprehensive Applications (2024KSYS001)
This publication has 39 references indexed in Scilit:
- Electron and proton FLASH beam dosimetry using unified alanine, EBT‐XD, and HD‐V2 Gafchromic film dosimetersMedical Physics, 2025
- Deep learning‐based dose prediction for low‐energy electron beam superficial radiotherapyPrecision Radiation Oncology, 2025
- Analysis of hydrogen peroxide production in pure water: Ultrahigh versus conventional dose‐rate irradiation and mechanistic insightsMedical Physics, 2024
- First Monte Carlo beam model for ultra‐high dose rate radiotherapy with a compact electron LINACMedical Physics, 2024
- Immune Priming with Spatially Fractionated Radiation TherapyCurrent Oncology Reports, 2023
- A journey to understand SFRTMedical Physics, 2023
- Ultra‐high dose rate dosimetry: Challenges and opportunities for FLASH radiation therapyMedical Physics, 2022
- Technical note: Validation of an ultrahigh dose rate pulsed electron beam monitoring system using a current transformer for FLASH preclinical studiesMedical Physics, 2022
- Nontoxic electron collimatorsJournal of Applied Clinical Medical Physics, 2021
- Spatially fractionated (GRID) radiation therapy using proton pencil beam scanning (PBS): Feasibility study and clinical implementationMedical Physics, 2018