Giacomo Navarra
Research Subjects
Giacomo Navarra has a total of 56 co-authors. Here are the top co-authors by number of shared publications:
- Francesco Lo Iacono
University of Enna “Kore
33 shared publications - Maria Oliva
Department of Engineering and Architecture, University of Enna “Kore”, 94100 Enna, Italy
10 shared publications - Antonina Pirrotta
Università degli Studi di Palermo
9 shared publications - Alberto Di Matteo
Department of Engineering, University of Palermo, Palermo, Italy
7 shared publications - Giorgio Barone
School of Architecture, Building and Civil Engineering, Sir Frank Gibb Building; Loughborough University; Loughborough LE11 3RN United Kingdom
5 shared publications - Massimiliano Gioffrè
University of Perugia
5 shared publications
Latest Publications
- Open Access
- 2 September 2026
- Published by Elsevier in Mechanical Systems and Signal Processing
- Vol. 259
Integrated physics-informed and unsupervised learning assessment of hemp-reinforced masonry barrel vaults under shaking table testing
- 2 September 2026
- Published by Elsevier in Mechanical Systems and Signal Processing
- Vol. 259
Open AccessIntegrated physics-informed and unsupervised learning assessment of hemp-reinforced masonry barrel vaults under shaking table testing
- 1 April 2026
- Published by Springer Nature
- p. 415-422
Shaking Table Experimental Characterization of a Large Scale Vertical Isolation System
- 1 April 2026
- Published by Springer Nature
- p. 415-422
Shaking Table Experimental Characterization of a Large Scale Vertical Isolation System
- 1 April 2026
- Published by Springer Nature
- p. 400-406
Seismic Response Modelling of a Full-Scale Masonry Barrel Vault Using Shaking Table Data
- 1 April 2026
- Published by Springer Nature
- p. 400-406
Seismic Response Modelling of a Full-Scale Masonry Barrel Vault Using Shaking Table Data
- 1 April 2026
- Published by Springer Nature
- p. 201-209
Design of a Seismic Damper with a Structural Optimization Process
- 1 April 2026
- Published by Springer Nature
- p. 201-209
Design of a Seismic Damper with a Structural Optimization Process
- 1 April 2026
- Published by Springer Nature
- p. 951-962
Analytical Modeling and Experimental Validation of a Base-Isolated Statue: the Case Study of the Goddess of Morgantina
- 1 April 2026
- Published by Springer Nature
- p. 951-962
Analytical Modeling and Experimental Validation of a Base-Isolated Statue: the Case Study of the Goddess of Morgantina
- 1 April 2026
- Published by Springer Nature
- p. 986-997
Effectiveness of Hemp-Rope-Based Bio-composite Material to Strengthen a Damaged Masonry Vault
- 1 April 2026
- Published by Springer Nature
- p. 986-997
Effectiveness of Hemp-Rope-Based Bio-composite Material to Strengthen a Damaged Masonry Vault
- Open Access
Shake Table Tests on Scaled Masonry Building: Comparison of Performance of Various Micro-Electromechanical System Accelerometers (MEMS) for Structural Health Monitoring
This study presents the results of an experimental investigation conducted on a 2:3 scale model of a two-story stone masonry building. We tested the model on the UniKORE L.E.D.A. lab shake table, simulating the Mw 6.3 earthquake ground motion that struck L’Aquila, Italy, on 6 April 2009, with progressively increasing peak acceleration levels. We installed a network of accelerometric sensors on the model to capture its structural behaviour under seismic excitation. Medium-to lower-cost MEMS accelerometers (classes A and B) were compared with traditional piezoelectric sensors commonly used in Structural Health Monitoring (SHM). The experiment assessed the structural performance and damage progression of masonry buildings subjected to realistic earthquake inputs. Additionally, the collected data provided valuable insights into the effectiveness of different sensor types and configurations in detecting key vibrational and failure patterns. All the sensors were able to accurately measure the dynamic response during seismic excitation. However, not all of them were suitable for Operational Modal Analysis (OMA) in noisy environments, where their self-noise represents a crucial factor. This suggests that the self-noise of MEMS accelerometers must be less than 1 µg/√Hz, or preferably below 0.5 µg/√Hz, to obtain good results from the OMA. Therefore, we recommend ultra-low-noise sensors for detecting differences in the structural behaviour before and after seismic events. Our findings provide valuable insights into the seismic vulnerability of masonry structures and the effectiveness of sensors in detecting damage. The management of buildings in earthquake-prone areas can benefit from these specifications.
Open AccessShake Table Tests on Scaled Masonry Building: Comparison of Performance of Various Micro-Electromechanical System Accelerometers (MEMS) for Structural Health Monitoring
This study presents the results of an experimental investigation conducted on a 2:3 scale model of a two-story stone masonry building. We tested the model on the UniKORE L.E.D.A. lab shake table, simulating the Mw 6.3 earthquake ground motion that struck L’Aquila, Italy, on 6 April 2009, with progressively increasing peak acceleration levels. We installed a network of accelerometric sensors on the model to capture its structural behaviour under seismic excitation. Medium-to lower-cost MEMS accelerometers (classes A and B) were compared with traditional piezoelectric sensors commonly used in Structural Health Monitoring (SHM). The experiment assessed the structural performance and damage progression of masonry buildings subjected to realistic earthquake inputs. Additionally, the collected data provided valuable insights into the effectiveness of different sensor types and configurations in detecting key vibrational and failure patterns. All the sensors were able to accurately measure the dynamic response during seismic excitation. However, not all of them were suitable for Operational Modal Analysis (OMA) in noisy environments, where their self-noise represents a crucial factor. This suggests that the self-noise of MEMS accelerometers must be less than 1 µg/√Hz, or preferably below 0.5 µg/√Hz, to obtain good results from the OMA. Therefore, we recommend ultra-low-noise sensors for detecting differences in the structural behaviour before and after seismic events. Our findings provide valuable insights into the seismic vulnerability of masonry structures and the effectiveness of sensors in detecting damage. The management of buildings in earthquake-prone areas can benefit from these specifications.
- Open Access
- 19 December 2024
- Published by MDPI AG in Preprints.org
Shake Table Tests on a Scaled Masonry Building: Performance Comparison of Various MEMS Accelerometers for SHM
This study presents the results of an experimental investigation conducted on a 2:3 scale model of a two-storey stone masonry building. We tested the model on the UniKORE L.E.D.A. lab shake table, simulating the Mw 6.3 earthquake ground motion that struck L’Aquila, Italy, on April 06, 2009, with progressively increasing peak acceleration levels. We installed a network of accelerometric sensors on the model to capture its structural behaviour under seismic excitation. Medium- to lower-cost MEMS accelerometers (Classes A and B) were compared with traditional piezoelectric sensors commonly used in Structural Health Monitoring (SHM). The experiment assessed the structural performance and damage progression of masonry buildings subjected to realistic earthquake inputs. Additionally, the collected data provided valuable insights into the effectiveness of different sensor types and configurations in detecting key vibrational and failure patterns. All the sensors were able to accurately measure the dynamic response during seismic excitation. However, not all of them were suitable for Operational Modal Analysis (OMA) in noisy environments, where their self-noise represents a crucial factor. This suggests that the self-noise of the MEMS accelerometers must be less than 1 µg/√Hz, or preferably below 0.5 µg/√Hz, to obtain good results from the OMA analysis. Therefore, we recommend ultra-low-noise sensors for detecting differences in structural behaviour before and after seismic events. Our findings provide valuable insights into the seismic vulnerability of masonry structures and effectiveness of sensors in detecting damage. The management of buildings in earthquake-prone areas can benefit from these specifications.
- 19 December 2024
- Published by MDPI AG in Preprints.org
Open AccessShake Table Tests on a Scaled Masonry Building: Performance Comparison of Various MEMS Accelerometers for SHM
This study presents the results of an experimental investigation conducted on a 2:3 scale model of a two-storey stone masonry building. We tested the model on the UniKORE L.E.D.A. lab shake table, simulating the Mw 6.3 earthquake ground motion that struck L’Aquila, Italy, on April 06, 2009, with progressively increasing peak acceleration levels. We installed a network of accelerometric sensors on the model to capture its structural behaviour under seismic excitation. Medium- to lower-cost MEMS accelerometers (Classes A and B) were compared with traditional piezoelectric sensors commonly used in Structural Health Monitoring (SHM). The experiment assessed the structural performance and damage progression of masonry buildings subjected to realistic earthquake inputs. Additionally, the collected data provided valuable insights into the effectiveness of different sensor types and configurations in detecting key vibrational and failure patterns. All the sensors were able to accurately measure the dynamic response during seismic excitation. However, not all of them were suitable for Operational Modal Analysis (OMA) in noisy environments, where their self-noise represents a crucial factor. This suggests that the self-noise of the MEMS accelerometers must be less than 1 µg/√Hz, or preferably below 0.5 µg/√Hz, to obtain good results from the OMA analysis. Therefore, we recommend ultra-low-noise sensors for detecting differences in structural behaviour before and after seismic events. Our findings provide valuable insights into the seismic vulnerability of masonry structures and effectiveness of sensors in detecting damage. The management of buildings in earthquake-prone areas can benefit from these specifications.