ACAna Rosa Costa

Ana Rosa Costa

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Ana Rosa Costa has a total of 95 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Device-dependent thermoforming effects on surface roughness and Knoop microhardness of thermoplastic aligner materials: An in vitro study

    by Karine Cavalcante de Moraes, Analia Gabriella Borges Ferraz Facury, Patrícia Auth Rockenbach, Evaldo Pinheiro Beserra Neto, Maria da Gloria Bellotti, Eduardo César Almada Santos, Lourenço Correr-Sobrinho, Ana Rosa Costa


  • Open Access

    Effect of the addition of thiourethane oligomers to experimental silanes and resin cement on the bond strength to glass ceramic

    by Anália Gabriella Borges Ferraz Facury, Ana Rosa Costa, Lincoln Pires Silva Borges, Fernanda Midori Tsuzuki, Américo Bortolazzo Correr, Carmem S. Pfeifer, Lourenço Correr-Sobrinho

  • Treatment of dental implant surfaces with graphene oxide nanoparticles: Synthesis, characterization, and assessment of antimicrobial potential

    by Ricardo Lima, José Guilherme Neves, Daniel Navarro da Rocha, Marcelo Henrique Prado da Silva, Mariah Cationi Hirata, Luan Menezes, Eduardo Martinelli Franco, Lourenço Correr-Sobrinho, Ana Rosa Costa

    This study assesses the synthesis and characterization of titanium implant surface nanocoating with graphene oxide (GO) at varying concentrations. Nanocoatings were applied using the dip coating technique, and GO nanoparticles were synthesized chemically. Physicochemical, morphological, and biological characterizations were conducted using scanning electron microscopy (SEM), transmission electron microscopy (TEM), Raman spectroscopy, in vitro bioactivity assay, cell viability, and colony-forming units per milliliter (CFU/mL). Cell viability data were subjected to two-way ANOVA, followed by Tukey’s test (α = 0.05). CFU/mL data were analyzed using the Kruskal-Wallis test, followed by Dunn’s test (α = 0.05). TEM revealed a sheet-like structure of GO nanoparticles. SEM showed the roughness of the nanocoated titanium surface. Raman spectroscopy indicated the presence of GO on the titanium surface, as evidenced by D and G bands. Higher apatite crystal deposition was observed on surfaces with greater GO concentrations at 7 and 14 days (bioactivity assay). The highest percentage of cell viability was noted in the 1.5% GO group after 48 h, compared to other groups at different time points ( p < 0.05). Surface treatment with varying GO concentrations induced greater cell viability compared to the acidic treatment ( p < 0.05). The 1.5% GO group showed the lowest antibacterial efficacy, as evidenced by the highest CFU/mL values ( p < 0.05). GO particles remained stable and chemically unchanged during the coating process. The GO-coated titanium surfaces showed no cytotoxicity and exhibited notable bioactive and antibacterial effects against Streptococcus mutans . These findings suggest that GO coatings may effectively enhance the biological and antimicrobial performance of titanium implants.


  • Open Access

    Torque expression in conventional and self-ligating orthodontic brackets: An in vitro study

    by Martha de Abreu Avila, José Guilherme Neves, Américo Bortolazzo Correr, Milton Santamaria-Junior, Eduardo Almada, Lourenço Correr-Sobrinho, Ana Rosa Costa

    This study assessed torque expression at different angulations of conventional, interactive, and passive self-ligating brackets, with or without metal ligatures, and evaluated surface morphology and chemical composition (%). All brackets (Roth prescription, 0.022" x 0.028" slot) were fixed to round acrylic cylinders with cyanoacrylate adhesive. Five hundred segments of rectangular archwires (0.019" x 0.025") were bent and welded (20 mm x 10 mm), then fixed to the brackets either with or without 0.010" metal ligatures in ten experimental groups (n = 10). The assembled specimens were then mounted on a universal testing machine, and a vertical force was applied to the free end of the archwire, resulting in a 10 mm displacement. Mean torque values (N·mm) at specified torque angles of 0° to 25°, as well as the mean torque angles (°) corresponding to 5 and 20 N·mm, were analyzed using ANOVA and Tukey’s test (α = 0.05). Bracket design and chemical composition were examined by SEM/EDS. Slot angulation and dimensional measurements were evaluated using ImageJ. Passive self-ligating brackets, without and with ligatures, showed the smallest torque angles, statistically smaller than those of the other groups (p < 0.001). Bracket clips were composed predominantly of nickel and titanium. Passive self-ligating brackets, either ligated or not, showed the highest torque expression at both 5 and 20 N·mm. Overall, torque expression was influenced more by the dimensional characteristics of brackets and rectangular archwires than by the type of ligature used. Clinically, passive self-ligating brackets may facilitate earlier torque expression during orthodontic treatment.

  • Open Access

    Surface Characteristics of Different Dental Cements after Incubation with Adherent and Non-adherent Strains of Streptococcus Mutans

    by Analia Gabriela Borges Ferraz Facury, Geraldo Thedei Júnior, Rodolfo Nunes de Almeida, Marcos Boaventura de Moura, Ana Rosa Costa, Lourenço Correr-Sobrinho, Gilberto Antonio Borges

    The aim of this study was to evaluate surface characteristics and Knoop hardness of two resin cements after incubation with adherent and non-adherent strains of Streptococcus mutans. The ATCC 25175 strain and a mutant isolated due to its low biofilm forming capacity and normal acidogenic capacity were used. Disks with 5 mm diameter and 2 mm thickness were fabricated with RelyX U200 and Allcem following the manufacturer’s instructions. Specimens were incubated in TSB medium with the adherent or non-adherent strains at 37ºC for 30 days, changing the culture medium every day, whereas control group specimens were incubated with sterile culture medium. Then, all specimens were subjected to microhardness Knoop. Representative specimens were examined using scanning electron microscopy (SEM). Tukey multiple comparisons test and unpaired t-test was used to compare two groups (α = 0.05). The resin cement RelyX U200 do not presented degradation or microhardness alteration under conditions tested. On the other hand, the resin cement Allcem presented more organic matrix degradation, exposing more filler particles after incubation with adherent strain than after incubation with the non-adherent strain. Microhardness of Allcem was smaller after incubation with ATCC strain than with non-adherent strain, and both presented smaller microhardness than the specimens of the control group. In conclusion, the resin cement RelyX U200 was not affected by the medium incubation with both adherent or non-adherent bacteria. The resin cement Allcem was more affected by the adherent bacteria strain then non-adherent regarding to surface topography.

  • Open Access

    5% Hop extract as disinfectant agent of orthodontic pliers

    by Pollyanna Rose de Melo Passos, Ana Rosa Costa, Cristina Maria Franzini, José Guilherme Neves, Lenita Marangoni-Lopes, Vivian Fernandes Furletti de Goes

    Objective To characterize and develop a hop extract disinfectant solution and to evaluate the effectiveness of a 5% hop extract solution in the disinfection of distal cut orthodontic pliers. Methods Distal cutting pliers (n=15) previously contaminated by S. mutans, randomized into 5 experimental groups (n=3): G1/AUT – autoclaved (negative control); G2/CNT – contaminated by S. mutans (positive control); G3/CLX – 2% Chlorhexidine; G4/HOP – 5% Hop Extract; G5/ALC − 70% Alcohol. The chemical parameters of the Hop extract solution was analyzed by Gas Chromatography coupled with Mass Spectrometry. After contamination, the pliers were immersed for 3 minutes in the respective disinfectant protocol. The microbiological analysis and the quantification of Colony Forming Unit (CFU/ml) were performed in pure and 1:10, 1:100 and 1:1000 serial dilutions. The result of the chemical analyzes were descriptive, and the microbiological analysis were submitted to analysis of variance and Tukey’s test with a significance level of 5%. Results The major chemical compounds were α- and β-acids. In microbiological tests, it was shown that all experimental groups differed significantly from G1/AUT (p<0.05). In the pure and 1:100 serial dilution, G2/CNT showed a significantly higher value than the other groups evaluated (p<0.05). In the 1:1000 dilution, G5/ALC showed a significantly higher average (p<0.05) than the others and did not differ only from G2/CNT (p<0.05). There was no significant difference in the CFU/mL of G4/HOP compared to G1/AUT and G3/CLX (p<0.05). Conclusion The 5% hop extract solution demonstrated antimicrobial effectiveness in the disinfection of orthodontic pliers contaminated with S. mutans.

  • Open Access

    Enamel Deproteinization with Sodium Hypochlorite: Effects on Ceramic Bracket Bond Strength

    by Priscila Cordeiro, José Guilherme Neves, Midori Tsuzuki, Anália Gabriela Ferraz Facury, Lourenço Correr-Sobrinho, Ana Rosa Costa

    To assess the efficiency of different concentrations of sodium hypochlorite (NaOCl) on the bonding of ceramic brackets to dental enamel using different bonding protocols. Ceramic, a polycrystalline bracket, was bonded to 90 extracted bovine incisors using primer + Transbond XT (P+TXT); Optibond S adhesive + Transbond XT (OS+TXT), and OS + Orthocem (OS+OC). Three concentrations of NaOCl (0%, 2.5%, and 5.25%) were used for each material, resulting in nine experimental groups (n=10). The shear bond strength (SBS) assay was performed on a universal testing machine. The surface morphology of the enamel and tooth/bonding material interface was examined under a scanning electron microscope. Kruskal-Wallis and Dunn’s tests were performed to compare the non-parametric data (ARI scores). SBS data were analyzed using a generalized linear model. All analyses were performed using the R program and with a significance level of 5%. No significant differences in SBS between the groups with different concentrations of NaOCl (p>0.05). OS+OC group yielded the lowest bond strength values (3.35 MPa_0%, 4.90 MPa_2.5%, 4.68 MPa_5.25%) compared to the other groups, regardless of NaOCl (p0.05). OS+TXT-5.25% showed significantly higher scores (14.4 MPa) than OS+TXT-2.5% (9.17 MPa) (p<0.05). The surface morphology analysis revealed a change in the etching pattern for types 1 and 2 when NaOCl was used. The different concentrations of NaOCl previously applied onto the enamel surface did not enhance bond strength. OS+OC should not be recommended for bonding with fixed ceramic orthodontic devices.


  • Synthesis and characterization of the chitosan-xanthan-graphene oxide film for bone regeneration using advanced cell therapy

    by Rafael Guedes de Paiva, José Guilherme Neves, Alana Souza, Daniel Navarro da Rocha, Lourenço Correr-Sobrinho, Ana Rosa Costa

    The present study aimed to synthesize and characterize polymer films at different graphene oxide (GO) concentrations for use in advanced cell therapy. Chitosan-xanthan (CX) films were prepared and combined with GO and then assigned to the following groups: G1 – CX; G2 – CX GO 0.5%; G3 – CX GO 1.0%; and G4 – CX GO 1.5%. The films were analyzed for their structural, mechanical, and biological properties by Raman and Fourier-Transform Infrared (FTIR) spectroscopy, Thermogravimetric Analysis (TGA), Scanning Electron Microscopy (SEM), Confocal Laser Scanning Microscopy (surface roughness measurement), Tensile Strength, and in vitro Bioactivity assay. Tensile strength and surface roughness data were analyzed by one-way analysis of variance (ANOVA), followed by Tukey’s test (α = 0.05). FTIR spectroscopy showed the presence of amide I and II bands (characteristic of chitosan) and carboxyl group (characteristic of xanthan). CO bands characteristic of GO were observed in groups containing these particles. Raman spectroscopy revealed D and G bands in the GO-containing groups. Film surface morphology exhibited a homogeneous, compact, and pore-free surface. The CX group had higher tensile strength (5.89 ± 1.62 KPa) ( p < 0.05). No statistically significant difference was observed in the other GO-containing groups ( p > 0.05). The films induced the deposition of apatite crystals on their surfaces, exhibiting activity under biomineralization conditions. Graphene oxide added into chitosan-xanthan films enhanced surface roughness and bioactivity but decreased tensile strength. The synthesized CXGO films are promising for advanced cell therapy because of their physicochemical, morphological, and mechanical properties, which seem ideal for tissue regeneration.


  • Open Access

    Effect of adding arginine at different concentrations to experimental orthodontic resins: an in vitro study

    by Ana Lídia Correa Santos, Lourenço Correr-Sobrinho, Fernanda Midori Tsuzuki, Anália Gabriela Facury Ferraz, José Guilherme Neves, Mário Alexandre Coelho Sinhoreti, Eduardo Martinelli Franco, Ana Rosa Costa

    The aim of this study was to assess the effect of adding arginine at different concentrations to commercial and experimental orthodontic resins on shear bond strength (SBS), as well as on the antimicrobial activity of arginine against S. mutans. Metal brackets were bonded onto the surface of 120 bovine incisors using Transbond, OrthoCem, and an experimental resin (ER), adding 0, 2.5, 5, and 7 wt.% of arginine. The SBS test was performed in deionized water at 37 ºC for 24 h, at 0.5 mm/min. SBS test results were subjected to two-way ANOVA and Tukey’s test (α = 0.05). CFU/mL data (antimicrobial assessment) were assessed by Kruskal-Wallis and Dunn’s tests (α = 0.05). No statistical difference between the resins was observed in untreated groups (p > 0.05). The addition of arginine at 2.5% (27.7 MPa) and 5% (29.0 MPa) increased the SBS of Transbond when compared (p < 0.05) to OrthoCem (18.5 and 15.6 MPa, respectively) and ER (16.3 and 18.1 MPa, respectively). Arginine at 7% improved the SBS of Transbond (24.1 MPa) and ER (21.0 MPa), which was statistically higher (p < 0.05) than OrthoCem (12.6 MPa). OrthoCem did not show a statistically significant difference at the three concentrations of arginine (p > 0.05). The addition of arginine to resins reduced the count of S. mutans (p < 0.05). As for ER, all concentrations of arginine significantly decreased CFU/mL (p < 0.05). Among commercial resins, only 7% of arginine significantly reduced CFU/mL. The addition of arginine did not interfere with the bond strength and demonstrated antibacterial activity against S. mutans.


  • Open Access

    Effect of hydrofluoric acid concentration and aging on the bond strength ceramics to a resin cement

    by Bruno Delgado Clerot, Lourenço Correr-Sobrinho, Milena Bandini, Evaldo Pinheiro Beserra-Neto, Fernanda Midori Tsuzuki, Rafael Rocha Pacheco, Ana Rosa Costa

    This study evaluated the influence of hydrofluoric acid (HF) concentration and thermal cycling on the microshear bond strength (µSBS) of a resin luting agent to IPS e.max® CAD and Rosetta® SM. Ceramic specimens (12.0 x 14.0 x 1.5mm) were randomized into 8 groups (n=10) according to HF concentration, commercial brand, and aging. Immediately after polishing, and etching, all specimens were silanized and a layer of adhesive was applied. A PVS mold of 3 mm thickness and 10mm diameter with (four) 1.0mm holes was fabricated, placed on each specimen, and then filled with a resin luting agent. Half of the specimens were subjected to the µSBS test using an Instron at a speed of 1.0 mm/min, following a 24-hour storage in deionized water at 37ºC. The remaining specimens were subjected to thermal cycling (5ºC-55ºC, 30 seconds per bath) and µSBS. The data were evaluated utilizing a three-way ANOVA and Tukey's post-hoc test (α=0.05). Significant differences were found for HF concentration and aging (p<0.0001). No significant difference in µSBS was found for commercial brands (p=0.085). The interaction between brand and HF concentration (p=0.358), brand and aging (p=0.135), and HF concentration and aging (p=0.138) were not statistically significant. The triple interaction among these factors was not statistically significant (p=0.610). In conclusion, the bond strength is affected by the HF concentration. No statistical difference was observed between the two ceramics. Thermal cycling significantly reduced µSBS.