Günther Bauernfeind
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Günther Bauernfeind has a total of 90 co-authors. Here are the top co-authors by number of shared publications:
Christa Neuper
Department of Psychology, University of Graz, Austria; BioTechMed-Graz, Austria; Laboratory of Brain-Computer Interfaces, Institute of Neural Engineering, Graz University of Technology, Austria
11 shared publications- Gernot R. Muller-Putz
Graz University of Technology
11 shared publications - Gert Pfurtscheller
Institute of Neural Engineering, Graz University of Technology, Graz, Austria
8 shared publications - Selina Christin Wriessnegger
Institute of Neural Engineering, Graz University of Technology, Stremayrgasse 16/IV, 8010 Graz, Austria
5 shared publications - Sabine Haumann
Department of Otorhinolaryngology, Hannover Medical School, Hannover, Germany
4 shared publications - Silvia Erika Kober
Department of Psychology, University of Graz, Graz, Austria
4 shared publications
Latest Publications
- Open Access
- 8 March 2022
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 19 (2) , 026002
Towards single-trial classification of invasively recorded auditory evoked potentials in cochlear implant users
Objective. One promising approach towards further improving cochlear implants (CI) is to use brain signals controlling the device in order to close the auditory loop. Initial electroencephalography (EEG) studies have already shown promising results. However, they are based on noninvasive measurements, whereas implanted electrodes are expected to be more convenient in terms of everyday-life usability. If additional measurement electrodes were implanted during CI surgery, then invasive recordings should be possible. Furthermore, implantation will provide better signal quality, higher robustness to artefacts, and thus enhanced classification accuracy. Approach. In an initial project, three additional epidural electrodes were temporarily implanted during the surgical procedure. After surgery, different auditory evoked potentials (AEPs) were recorded both invasively (epidural) and using surface electrodes, with invasively recorded signals demonstrated as being markedly superior. In this present analysis, cortical evoked response audiometry (CERA) signals recorded in seven patients were used for single-trial classification of sounds with different intensities. For classification purposes, we used shrinkage-regularized linear discriminant analysis (sLDA). Clinical speech perception scores were also investigated. Main results. Analysis of CERA data from different subjects showed single-trial classification accuracies of up to 99.2% for perceived vs. non-perceived sounds. Accuracies of up to 89.1% were achieved in classification of sounds perceived at different intensities. Highest classification accuracies were achieved by means of epidural recordings. Required loudness differences seemed to correspond to speech perception in noise. Significance. The proposed epidural recording approach showed good classification accuracy into sound perceived and not perceived when the best-performing electrodes were selected. Classifying different levels of sound stimulation accurately proved more challenging. At present, the methods explored in this study would not be sufficiently reliable to allow automated closed-loop control of CI parameters. However, our findings are an important initial contribution towards improving applicability of closed auditory loops and for next-generation automatic fitting approaches.
- 8 March 2022
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 19 (2) , 026002
Open AccessTowards single-trial classification of invasively recorded auditory evoked potentials in cochlear implant users
Objective. One promising approach towards further improving cochlear implants (CI) is to use brain signals controlling the device in order to close the auditory loop. Initial electroencephalography (EEG) studies have already shown promising results. However, they are based on noninvasive measurements, whereas implanted electrodes are expected to be more convenient in terms of everyday-life usability. If additional measurement electrodes were implanted during CI surgery, then invasive recordings should be possible. Furthermore, implantation will provide better signal quality, higher robustness to artefacts, and thus enhanced classification accuracy. Approach. In an initial project, three additional epidural electrodes were temporarily implanted during the surgical procedure. After surgery, different auditory evoked potentials (AEPs) were recorded both invasively (epidural) and using surface electrodes, with invasively recorded signals demonstrated as being markedly superior. In this present analysis, cortical evoked response audiometry (CERA) signals recorded in seven patients were used for single-trial classification of sounds with different intensities. For classification purposes, we used shrinkage-regularized linear discriminant analysis (sLDA). Clinical speech perception scores were also investigated. Main results. Analysis of CERA data from different subjects showed single-trial classification accuracies of up to 99.2% for perceived vs. non-perceived sounds. Accuracies of up to 89.1% were achieved in classification of sounds perceived at different intensities. Highest classification accuracies were achieved by means of epidural recordings. Required loudness differences seemed to correspond to speech perception in noise. Significance. The proposed epidural recording approach showed good classification accuracy into sound perceived and not perceived when the best-performing electrodes were selected. Classifying different levels of sound stimulation accurately proved more challenging. At present, the methods explored in this study would not be sufficiently reliable to allow automated closed-loop control of CI parameters. However, our findings are an important initial contribution towards improving applicability of closed auditory loops and for next-generation automatic fitting approaches.
- 1 September 2019
- Published by Elsevier in Neurobiology of Aging
- Vol. 81, 127-137
Age-related differences in the within-session trainability of hemodynamic parameters: a near-infrared spectroscopy–based neurofeedback study
- 1 September 2019
- Published by Elsevier in Neurobiology of Aging
- Vol. 81, 127-137
Age-related differences in the within-session trainability of hemodynamic parameters: a near-infrared spectroscopy–based neurofeedback study
- Open Access
- 30 July 2019
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 16 (5) , 056008
Epidural recordings in cochlear implant users
Objective. In the long term it is desirable for CI users to control their device via brain signals. A possible strategy is the use of auditory evoked potentials (AEPs). Several studies have shown the suitability of auditory paradigms for such an approach. However, these investigations are based on non-invasive recordings. When thinking about everyday life applications, it would be more convenient to use implanted electrodes for signal acquisition. Ideally, the electrodes would be directly integrated into the CI. Further it is to be expected that invasively recorded signals have higher signal quality and are less affected by artifacts. Approach. In this project we investigated the feasibility of implanting epidural electrodes temporarily during CI surgery and the possibility to record AEPs in the course of several days after implantation. Intraoperatively, auditory brainstem responses were recorded, whereas various kinds of AEPs were recorded postoperatively. After a few days the epidural electrodes were removed. Main results. Data sets of ten subjects were obtained. Invasively recorded potentials were compared subjectively and objectively to clinical standard recordings using surface electrodes. Especially the cortical evoked response audiometry depicted clearer N1 waves for the epidural electrodes which were also visible at lower stimulation intensities compared to scalp electrodes. Furthermore the signal was less disturbed by artifacts. The objective quality measure (based on data sets of six patients) showed a significant better signal quality for the epidural compared to the scalp recordings. Significance. Altogether the approach revealed to be feasible and well tolerated by the patients. The epidural recordings showed a clearly better signal quality than the scalp recordings with AEPs being clearer recognizable. The results of the present study suggest that including epidural recording electrodes in future CI systems will improve the everyday life applicability of auditory closed loop systems for CI subjects.
- 30 July 2019
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 16 (5) , 056008
Open AccessEpidural recordings in cochlear implant users
Objective. In the long term it is desirable for CI users to control their device via brain signals. A possible strategy is the use of auditory evoked potentials (AEPs). Several studies have shown the suitability of auditory paradigms for such an approach. However, these investigations are based on non-invasive recordings. When thinking about everyday life applications, it would be more convenient to use implanted electrodes for signal acquisition. Ideally, the electrodes would be directly integrated into the CI. Further it is to be expected that invasively recorded signals have higher signal quality and are less affected by artifacts. Approach. In this project we investigated the feasibility of implanting epidural electrodes temporarily during CI surgery and the possibility to record AEPs in the course of several days after implantation. Intraoperatively, auditory brainstem responses were recorded, whereas various kinds of AEPs were recorded postoperatively. After a few days the epidural electrodes were removed. Main results. Data sets of ten subjects were obtained. Invasively recorded potentials were compared subjectively and objectively to clinical standard recordings using surface electrodes. Especially the cortical evoked response audiometry depicted clearer N1 waves for the epidural electrodes which were also visible at lower stimulation intensities compared to scalp electrodes. Furthermore the signal was less disturbed by artifacts. The objective quality measure (based on data sets of six patients) showed a significant better signal quality for the epidural compared to the scalp recordings. Significance. Altogether the approach revealed to be feasible and well tolerated by the patients. The epidural recordings showed a clearly better signal quality than the scalp recordings with AEPs being clearer recognizable. The results of the present study suggest that including epidural recording electrodes in future CI systems will improve the everyday life applicability of auditory closed loop systems for CI subjects.
- Open Access
- 1 January 2019
- Published by SAGE Publications in Trends in Hearing
- Vol. 23
Monitoring of the Inner Ear Function During and After Cochlear Implant Insertion Using Electrocochleography
To preserve residual hearing during cochlear implant (CI) surgery, it is desirable to use intraoperative monitoring of inner ear function (cochlear monitoring), especially during electrode insertion. A promising method is electrocochleography (ECochG). Within this project, the relations between ongoing responses (ORs), recorded extra- and intracochlearly (EC and IC), and preservation of residual hearing were investigated. Before, during, and after insertion of hearing preservation electrodes, intraoperative ECochG recordings were performed EC using a cotton wick electrode and after insertion also IC using the CI electrode (MED-EL) and a research software tool. The stimulation was delivered acoustically using low frequency tone bursts. The recordings were conducted in 10 adult CI recipients. The amplitudes of IC ORs were detected to be larger than EC ORs. Intraoperative EC thresholds correlated highly to preoperative audiometric thresholds at 1000 Hz, IC thresholds highly at 250 Hz and 500 Hz. The correlations of both intraoperative ECochG recordings to postoperative pure tone thresholds were low. When measured postoperatively at the same appointments, IC OR thresholds correlated highly to audiometric pure tone thresholds. For all patients, it was possible to record ORs during or directly after electrode insertion. Consequently, we conclude that we did not observe any cases with severe IC trauma. Delayed hearing loss could not be predicted with our method. Nevertheless, intraoperative ECochG recordings are a promising tool to gain further insight into mechanisms impacting residual hearing. Postoperatively recorded IC OR thresholds seem to be a reliable tool for frequency specific hearing threshold estimation.
- 1 January 2019
- Published by SAGE Publications in Trends in Hearing
- Vol. 23
Open AccessMonitoring of the Inner Ear Function During and After Cochlear Implant Insertion Using Electrocochleography
To preserve residual hearing during cochlear implant (CI) surgery, it is desirable to use intraoperative monitoring of inner ear function (cochlear monitoring), especially during electrode insertion. A promising method is electrocochleography (ECochG). Within this project, the relations between ongoing responses (ORs), recorded extra- and intracochlearly (EC and IC), and preservation of residual hearing were investigated. Before, during, and after insertion of hearing preservation electrodes, intraoperative ECochG recordings were performed EC using a cotton wick electrode and after insertion also IC using the CI electrode (MED-EL) and a research software tool. The stimulation was delivered acoustically using low frequency tone bursts. The recordings were conducted in 10 adult CI recipients. The amplitudes of IC ORs were detected to be larger than EC ORs. Intraoperative EC thresholds correlated highly to preoperative audiometric thresholds at 1000 Hz, IC thresholds highly at 250 Hz and 500 Hz. The correlations of both intraoperative ECochG recordings to postoperative pure tone thresholds were low. When measured postoperatively at the same appointments, IC OR thresholds correlated highly to audiometric pure tone thresholds. For all patients, it was possible to record ORs during or directly after electrode insertion. Consequently, we conclude that we did not observe any cases with severe IC trauma. Delayed hearing loss could not be predicted with our method. Nevertheless, intraoperative ECochG recordings are a promising tool to gain further insight into mechanisms impacting residual hearing. Postoperatively recorded IC OR thresholds seem to be a reliable tool for frequency specific hearing threshold estimation.
- 1 October 2018
- Published by Elsevier in Brain and Cognition
- Vol. 126, 13-22
Imagine squeezing a cactus: Cortical activation during affective motor imagery measured by functional near-infrared spectroscopy
- 1 October 2018
- Published by Elsevier in Brain and Cognition
- Vol. 126, 13-22
Imagine squeezing a cactus: Cortical activation during affective motor imagery measured by functional near-infrared spectroscopy
- 1 August 2018
- Published by Elsevier in Brain and Cognition
- Vol. 125, 78-87
Towards using fNIRS recordings of mental arithmetic for the detection of residual cognitive activity in patients with disorders of consciousness (DOC)
- 1 August 2018
- Published by Elsevier in Brain and Cognition
- Vol. 125, 78-87
Towards using fNIRS recordings of mental arithmetic for the detection of residual cognitive activity in patients with disorders of consciousness (DOC)
- 1 July 2018
- Published by Elsevier in Biological Psychology
- Vol. 136, 168-180
Trainability of hemodynamic parameters: A near-infrared spectroscopy based neurofeedback study
- 1 July 2018
- Published by Elsevier in Biological Psychology
- Vol. 136, 168-180
Trainability of hemodynamic parameters: A near-infrared spectroscopy based neurofeedback study
- 8 March 2018
- Published by Wiley in Human Brain Mapping
- Vol. 39 (7) , 2710-2724
Cortical activation patterns to spatially presented pure tone stimuli with different intensities measured by functional near‐infrared spectroscopy
Functional near‐infrared spectroscopy (fNIRS) is an emerging technique for the assessment of functional activity of the cerebral cortex. Recently fNIRS was also envisaged as a novel neuroimaging approach for measuring the auditory cortex activity in the field of in auditory diagnostics. This study aimed to investigate differences in brain activity related to spatially presented sounds with different intensities in 10 subjects by means of functional near‐infrared spectroscopy (fNIRS). We found pronounced cortical activation patterns in the temporal and frontal regions of both hemispheres. In contrast to these activation patterns, we found deactivation patterns in central and parietal regions of both hemispheres. Furthermore our results showed an influence of spatial presentation and intensity of the presented sounds on brain activity in related regions of interest. These findings are in line with previous fMRI studies which also reported systematic changes of activation in temporal and frontal areas with increasing sound intensity. Although clear evidence for contralaterality effects and hemispheric asymmetries were absent in the group data, these effects were partially visible on the single subject level. Concluding, fNIRS is sensitive enough to capture differences in brain responses during the spatial presentation of sounds with different intensities in several cortical regions. Our results may serve as a valuable contribution for further basic research and the future use of fNIRS in the area of central auditory diagnostics.
- 8 March 2018
- Published by Wiley in Human Brain Mapping
- Vol. 39 (7) , 2710-2724
Cortical activation patterns to spatially presented pure tone stimuli with different intensities measured by functional near‐infrared spectroscopy
Functional near‐infrared spectroscopy (fNIRS) is an emerging technique for the assessment of functional activity of the cerebral cortex. Recently fNIRS was also envisaged as a novel neuroimaging approach for measuring the auditory cortex activity in the field of in auditory diagnostics. This study aimed to investigate differences in brain activity related to spatially presented sounds with different intensities in 10 subjects by means of functional near‐infrared spectroscopy (fNIRS). We found pronounced cortical activation patterns in the temporal and frontal regions of both hemispheres. In contrast to these activation patterns, we found deactivation patterns in central and parietal regions of both hemispheres. Furthermore our results showed an influence of spatial presentation and intensity of the presented sounds on brain activity in related regions of interest. These findings are in line with previous fMRI studies which also reported systematic changes of activation in temporal and frontal areas with increasing sound intensity. Although clear evidence for contralaterality effects and hemispheric asymmetries were absent in the group data, these effects were partially visible on the single subject level. Concluding, fNIRS is sensitive enough to capture differences in brain responses during the spatial presentation of sounds with different intensities in several cortical regions. Our results may serve as a valuable contribution for further basic research and the future use of fNIRS in the area of central auditory diagnostics.
- 1 October 2017
- Published by Elsevier in Brain and Cognition
- Vol. 117, 108-116
Force related hemodynamic responses during execution and imagery of a hand grip task: A functional near infrared spectroscopy study
- 1 October 2017
- Published by Elsevier in Brain and Cognition
- Vol. 117, 108-116
Force related hemodynamic responses during execution and imagery of a hand grip task: A functional near infrared spectroscopy study
- 1 January 2017
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. 62 (s1) , s77
Session 22. Imaging in Hearing
- 1 January 2017
- Published by Walter de Gruyter GmbH in Biomedical Engineering / Biomedizinische Technik
- Vol. 62 (s1) , s77
Session 22. Imaging in Hearing