Sabine Haumann
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sabine Haumann has a total of 39 co-authors. Here are the top co-authors by number of shared publications:
Thomas Lenarz
Department of Otorhinolaryngology, Hannover Medical School, Hannover, Germany
8 shared publicationsAndreas Büchner
Department of Otorhinolaryngology, Hannover Medical School, Hannover, Germany
7 shared publications- Günther Bauernfeind
Department of Otolaryngology and Cluster of Excellence "Hearing4all", Hannover Medical School, Hannover, Germany
4 shared publications Rolf B. Salcher
Department of Otorhinolaryngology, Hannover Medical School, Hannover, Germany
4 shared publications- Thomas Lenarz
Department of Otolaryngology, Hannover Medical School, Hannover, Germany
4 shared publications A Büchner
Department of Otolaryngology, Hannover Medical School, Hannover, Germany
2 shared publications
Latest Publications
- Open Access
- 30 April 2025
- Published by Frontiers Media SA in Frontiers in Audiology and Otology
- Vol. 3, 1560648
Hearing preservation after cochlear implantation evaluated using Auditory Steady State Responses
Introduction: For several years now, also patients with significant acoustic hearing can receive a cochlear implant in order to combine acoustic and electric hearing. For this purpose, atraumatic electrodes were designed and used as standard. Tools were developed to monitor hearing preservation during surgery.Methods: For this purpose, Auditory Steady State Responses (ASSRs) were recorded intraoperatively under general anesthesia directly before and after surgical intervention. In contrast to other common electrophysiological methods such as Auditory Brainstem Responses (ABR) or Electrocochleography (ECochG), where transient potentials are measured and evaluated in the time domain for the presence or absence of certain waveforms, with ASSR stationary potentials are measured and evaluated using the phase or frequency of the recorded signal and calculating the probability that a stimulus response is present. ASSR thresholds were recorded at six frequencies (250 Hz, 500 Hz, 1 kHz, 2 kHz, 4 kHz, and 8 kHz) using sine waves. The measurements were completed for 155 ears, with 78 ears being provided with a Nucleus SRA electrode, 55 ears had a Hybrid-L electrode and 22 ears were fitted with other types of electrode.Results: ASSR threshold shifts correlated to hearing threshold shifts modestly but significantly at 1 kHz (r = 0.34, p < 0.01), where the recorded ASSR thresholds were closer to the hearing thresholds than at 250 and 500 Hz and less variance occurred.Discussion: This suggests that, in many cases, damage to residual hearing is due to intraoperative adverse events, like trauma to the cochlea or mechanical dampening of the basilar membrane. Therefore, ASSR offers certain prospects for the early detection of damage to residual hearing and thus the option for early intervention. ASSR recordings of all frequencies are time consuming. However, based on the data presented here, we would recommend including a reduced measurement protocol, just at 1 kHz, in a future system for monitoring residual hearing during CI insertion complementary to other possible measurement methods. We would also suggest investigating whether the use of chirp stimuli instead of sine waves would lead to higher correlations.
- 30 April 2025
- Published by Frontiers Media SA in Frontiers in Audiology and Otology
- Vol. 3, 1560648
Open AccessHearing preservation after cochlear implantation evaluated using Auditory Steady State Responses
Introduction: For several years now, also patients with significant acoustic hearing can receive a cochlear implant in order to combine acoustic and electric hearing. For this purpose, atraumatic electrodes were designed and used as standard. Tools were developed to monitor hearing preservation during surgery.Methods: For this purpose, Auditory Steady State Responses (ASSRs) were recorded intraoperatively under general anesthesia directly before and after surgical intervention. In contrast to other common electrophysiological methods such as Auditory Brainstem Responses (ABR) or Electrocochleography (ECochG), where transient potentials are measured and evaluated in the time domain for the presence or absence of certain waveforms, with ASSR stationary potentials are measured and evaluated using the phase or frequency of the recorded signal and calculating the probability that a stimulus response is present. ASSR thresholds were recorded at six frequencies (250 Hz, 500 Hz, 1 kHz, 2 kHz, 4 kHz, and 8 kHz) using sine waves. The measurements were completed for 155 ears, with 78 ears being provided with a Nucleus SRA electrode, 55 ears had a Hybrid-L electrode and 22 ears were fitted with other types of electrode.Results: ASSR threshold shifts correlated to hearing threshold shifts modestly but significantly at 1 kHz (r = 0.34, p < 0.01), where the recorded ASSR thresholds were closer to the hearing thresholds than at 250 and 500 Hz and less variance occurred.Discussion: This suggests that, in many cases, damage to residual hearing is due to intraoperative adverse events, like trauma to the cochlea or mechanical dampening of the basilar membrane. Therefore, ASSR offers certain prospects for the early detection of damage to residual hearing and thus the option for early intervention. ASSR recordings of all frequencies are time consuming. However, based on the data presented here, we would recommend including a reduced measurement protocol, just at 1 kHz, in a future system for monitoring residual hearing during CI insertion complementary to other possible measurement methods. We would also suggest investigating whether the use of chirp stimuli instead of sine waves would lead to higher correlations.
- Open Access
- 16 January 2025
- Published by Frontiers Media SA in Frontiers in Neuroscience
- Vol. 18, 1530216
Does the audiogram shape influence the intracochlear recording of Electrocochleography during and after cochlear implantation?
During cochlear implant (CI) surgery, it is desirable to perform intraoperative measurements such as Electrocochleography (ECochG) to monitor the inner ear function and thereby to support the preservation of residual hearing. However, a significant challenge arises as the recording location of intracochlear ECochG via the CI electrode changes during electrode insertion. This study aimed to investigate the relationships between intracochlear ECochG recordings, the position of the recording contact within the cochlea relative to its anatomy, and the implications for frequency and residual hearing preservation. Intraoperative ECochG recordings were conducted using the CI electrode (MED-EL) during the insertion of hearing preservation electrodes and after the insertion process. Recordings were continuously conducted using the most apical electrode (contact 1) during insertion. After insertion, the recordings were performed on all different electrode contacts. The electrode location in the cochlea during insertion was estimated using mathematical models and preoperative clinical imaging, while the postoperative electrode position was determined using postoperative clinical imaging. The study involved 10 adult CI recipients. In those with good low-frequency hearing, an increase in signal amplitude was observed, with the highest amplitudes closest to the stimulation frequency generators, and no phase change was observed. Conversely, patients with flat hearing loss exhibited a second peak with an opposite phase in the medial area of the cochlea. This study is the first to suggest that the pattern of the preoperative audiogram may influence the ECochG outcomes measured intraoperatively. Specifically, the ECochG responses during insertion appeared to behave as expected with good low-frequency hearing, while with flat hearing loss there appear to be further effects. These findings indicate that this approach can provide valuable information for the interpretation of intracochlearly recorded ECochG signals.
- 16 January 2025
- Published by Frontiers Media SA in Frontiers in Neuroscience
- Vol. 18, 1530216
Open AccessDoes the audiogram shape influence the intracochlear recording of Electrocochleography during and after cochlear implantation?
During cochlear implant (CI) surgery, it is desirable to perform intraoperative measurements such as Electrocochleography (ECochG) to monitor the inner ear function and thereby to support the preservation of residual hearing. However, a significant challenge arises as the recording location of intracochlear ECochG via the CI electrode changes during electrode insertion. This study aimed to investigate the relationships between intracochlear ECochG recordings, the position of the recording contact within the cochlea relative to its anatomy, and the implications for frequency and residual hearing preservation. Intraoperative ECochG recordings were conducted using the CI electrode (MED-EL) during the insertion of hearing preservation electrodes and after the insertion process. Recordings were continuously conducted using the most apical electrode (contact 1) during insertion. After insertion, the recordings were performed on all different electrode contacts. The electrode location in the cochlea during insertion was estimated using mathematical models and preoperative clinical imaging, while the postoperative electrode position was determined using postoperative clinical imaging. The study involved 10 adult CI recipients. In those with good low-frequency hearing, an increase in signal amplitude was observed, with the highest amplitudes closest to the stimulation frequency generators, and no phase change was observed. Conversely, patients with flat hearing loss exhibited a second peak with an opposite phase in the medial area of the cochlea. This study is the first to suggest that the pattern of the preoperative audiogram may influence the ECochG outcomes measured intraoperatively. Specifically, the ECochG responses during insertion appeared to behave as expected with good low-frequency hearing, while with flat hearing loss there appear to be further effects. These findings indicate that this approach can provide valuable information for the interpretation of intracochlearly recorded ECochG signals.
- Open Access
- 1 January 2024
- Published by SAGE Publications in Trends in Hearing
- Vol. 28
Does Intraoperative Extracochlear Electrocochleography Correlate With Postoperative Audiometric Hearing Thresholds in Cochlear Implant Surgery? A Retrospective Analysis of Cochlear Monitoring
In recent years, tools for early detection of irreversible trauma to the basilar membrane during hearing preservation cochlear implant (CI) surgery were established in several clinics. A link with the degree of postoperative hearing preservation in patients was investigated, but patient populations were usually small. Therefore, this study's aim was to analyze data from intraoperative extracochlear electrocochleography (ECochG) recordings for a larger group. During hearing preservation CI surgery, extracochlear recordings were made before, during, and after CI electrode insertion using a cotton wick electrode placed at the promontory. Before and after insertion, amplitudes and stimulus response thresholds were recorded at 250, 500, and 1000 Hz. During insertion, response amplitudes were recorded at one frequency and one stimulus level. Data from 121 patient ears were analyzed. The key benefit of extracochlear recordings is that they can be performed before, during, and after CI electrode insertion. However, extracochlear ECochG threshold changes before and after CI insertion were relatively small and did not independently correlate well with hearing preservation, although at 250 Hz they added some significant information. Some tendencies—although no significant relationships—were detected between amplitude behavior and hearing preservation. Rising amplitudes seem favorable and falling amplitudes disadvantageous, but constant amplitudes do not appear to allow stringent predictions. Extracochlear ECochG measurements seem to only partially realize expected benefits. The questions now are: do gains justify the effort, and do other procedures or possible combinations lead to greater benefits for patients?
- 1 January 2024
- Published by SAGE Publications in Trends in Hearing
- Vol. 28
Open AccessDoes Intraoperative Extracochlear Electrocochleography Correlate With Postoperative Audiometric Hearing Thresholds in Cochlear Implant Surgery? A Retrospective Analysis of Cochlear Monitoring
In recent years, tools for early detection of irreversible trauma to the basilar membrane during hearing preservation cochlear implant (CI) surgery were established in several clinics. A link with the degree of postoperative hearing preservation in patients was investigated, but patient populations were usually small. Therefore, this study's aim was to analyze data from intraoperative extracochlear electrocochleography (ECochG) recordings for a larger group. During hearing preservation CI surgery, extracochlear recordings were made before, during, and after CI electrode insertion using a cotton wick electrode placed at the promontory. Before and after insertion, amplitudes and stimulus response thresholds were recorded at 250, 500, and 1000 Hz. During insertion, response amplitudes were recorded at one frequency and one stimulus level. Data from 121 patient ears were analyzed. The key benefit of extracochlear recordings is that they can be performed before, during, and after CI electrode insertion. However, extracochlear ECochG threshold changes before and after CI insertion were relatively small and did not independently correlate well with hearing preservation, although at 250 Hz they added some significant information. Some tendencies—although no significant relationships—were detected between amplitude behavior and hearing preservation. Rising amplitudes seem favorable and falling amplitudes disadvantageous, but constant amplitudes do not appear to allow stringent predictions. Extracochlear ECochG measurements seem to only partially realize expected benefits. The questions now are: do gains justify the effort, and do other procedures or possible combinations lead to greater benefits for patients?
- Open Access
- 1 January 2024
- Published by SAGE Publications in Trends in Hearing
- Vol. 28
Intracochlear Recording of Electrocochleography During and After Cochlear Implant Insertion Dependent on the Location in the Cochlea
To preserve residual hearing during cochlear implant (CI) surgery it is desirable to use intraoperative monitoring of inner ear function (cochlear monitoring). A promising method is electrocochleography (ECochG). Within this project the relations between intracochlear ECochG recordings, position of the recording contact in the cochlea with respect to anatomy and frequency and preservation of residual hearing were investigated. The aim was to better understand the changes in ECochG signals and whether these are due to the electrode position in the cochlea or to trauma generated during insertion. During and after insertion of hearing preservation electrodes, intraoperative ECochG recordings were performed using the CI electrode (MED-EL). During insertion, the recordings were performed at discrete insertion steps on electrode contact 1. After insertion as well as postoperatively the recordings were performed at different electrode contacts. The electrode location in the cochlea during insertion was estimated by mathematical models using preoperative clinical imaging, the postoperative location was measured using postoperative clinical imaging. The recordings were analyzed from six adult CI recipients. In the four patients with good residual hearing in the low frequencies the signal amplitude rose with largest amplitudes being recorded closest to the generators of the stimulation frequency, while in both cases with severe pantonal hearing losses the amplitude initially rose and then dropped. This might be due to various reasons as discussed in the following. Our results indicate that this approach can provide valuable information for the interpretation of intracochlearly recorded ECochG signals.
- 1 January 2024
- Published by SAGE Publications in Trends in Hearing
- Vol. 28
Open AccessIntracochlear Recording of Electrocochleography During and After Cochlear Implant Insertion Dependent on the Location in the Cochlea
To preserve residual hearing during cochlear implant (CI) surgery it is desirable to use intraoperative monitoring of inner ear function (cochlear monitoring). A promising method is electrocochleography (ECochG). Within this project the relations between intracochlear ECochG recordings, position of the recording contact in the cochlea with respect to anatomy and frequency and preservation of residual hearing were investigated. The aim was to better understand the changes in ECochG signals and whether these are due to the electrode position in the cochlea or to trauma generated during insertion. During and after insertion of hearing preservation electrodes, intraoperative ECochG recordings were performed using the CI electrode (MED-EL). During insertion, the recordings were performed at discrete insertion steps on electrode contact 1. After insertion as well as postoperatively the recordings were performed at different electrode contacts. The electrode location in the cochlea during insertion was estimated by mathematical models using preoperative clinical imaging, the postoperative location was measured using postoperative clinical imaging. The recordings were analyzed from six adult CI recipients. In the four patients with good residual hearing in the low frequencies the signal amplitude rose with largest amplitudes being recorded closest to the generators of the stimulation frequency, while in both cases with severe pantonal hearing losses the amplitude initially rose and then dropped. This might be due to various reasons as discussed in the following. Our results indicate that this approach can provide valuable information for the interpretation of intracochlearly recorded ECochG signals.
- Open Access
- 22 April 2022
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 17 (4) , e0266077
Clinical experiences with intraoperative electrocochleography in cochlear implant recipients and its potential to reduce insertion trauma and improve postoperative hearing preservation
Access to low-frequency acoustic information in cochlear implant patients leads to better speech understanding in noise. Electrocochleography (ECochG) can provide real-time feedback about the health of the cochlea during the insertion process with the potential to reduce insertion trauma. We describe our experiences of using this technique. Data from 47 adult subjects with measurable residual hearing and an Advanced Bionics (Valencia, CA) SlimJ (46) or MidScala (1) electrode array were analyzed. ECochGs were recorded intraoperatively via the implant. The surgeon adjusted the course of the electrode insertion based on drops in the ECochG. The final array position was assessed using postoperative imaging and pure tone thresholds were measured before and after surgery. Three different patterns of ECochG response amplitude were observed: Growth, Fluctuating and Total Loss. Subjects in the growth group showed the smallest postoperative hearing loss. However, the group with fluctuating amplitudes showed no meaningful correlation between the ECochG responses and the postoperative hearing loss, indicating that amplitude alone is insufficient for detecting damage. Considering the phase of the signal additionally to the amplitude and reclassifying the data by both the phase and amplitude of the response into three groups Type I–Type III produced statistically significant correlations between postoperative hearing loss and the grouping based on amplitude and phase respectively. We showed significantly better hearing preservation for Type I (no drop in amplitude) and Type II (drop with a concurrent phase shift), while Type III (drop without concurrent phase shift) had more surgery induced hearing loss. ECochG potentials measured through the implant could provide valuable feedback during the electrode insertion. Both the amplitude and phase of the ECochG response are important to consider. More data needs to be evaluated to better understand the impact of the different signal components to design an automated system to alert the surgeon ahead of damaging the cochlea.
- 22 April 2022
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 17 (4) , e0266077
Open AccessClinical experiences with intraoperative electrocochleography in cochlear implant recipients and its potential to reduce insertion trauma and improve postoperative hearing preservation
Access to low-frequency acoustic information in cochlear implant patients leads to better speech understanding in noise. Electrocochleography (ECochG) can provide real-time feedback about the health of the cochlea during the insertion process with the potential to reduce insertion trauma. We describe our experiences of using this technique. Data from 47 adult subjects with measurable residual hearing and an Advanced Bionics (Valencia, CA) SlimJ (46) or MidScala (1) electrode array were analyzed. ECochGs were recorded intraoperatively via the implant. The surgeon adjusted the course of the electrode insertion based on drops in the ECochG. The final array position was assessed using postoperative imaging and pure tone thresholds were measured before and after surgery. Three different patterns of ECochG response amplitude were observed: Growth, Fluctuating and Total Loss. Subjects in the growth group showed the smallest postoperative hearing loss. However, the group with fluctuating amplitudes showed no meaningful correlation between the ECochG responses and the postoperative hearing loss, indicating that amplitude alone is insufficient for detecting damage. Considering the phase of the signal additionally to the amplitude and reclassifying the data by both the phase and amplitude of the response into three groups Type I–Type III produced statistically significant correlations between postoperative hearing loss and the grouping based on amplitude and phase respectively. We showed significantly better hearing preservation for Type I (no drop in amplitude) and Type II (drop with a concurrent phase shift), while Type III (drop without concurrent phase shift) had more surgery induced hearing loss. ECochG potentials measured through the implant could provide valuable feedback during the electrode insertion. Both the amplitude and phase of the ECochG response are important to consider. More data needs to be evaluated to better understand the impact of the different signal components to design an automated system to alert the surgeon ahead of damaging the cochlea.
- Open Access
- 8 March 2022
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 19 (2) , 026002
Towards single-trial classification of invasively recorded auditory evoked potentials in cochlear implant users
Objective. One promising approach towards further improving cochlear implants (CI) is to use brain signals controlling the device in order to close the auditory loop. Initial electroencephalography (EEG) studies have already shown promising results. However, they are based on noninvasive measurements, whereas implanted electrodes are expected to be more convenient in terms of everyday-life usability. If additional measurement electrodes were implanted during CI surgery, then invasive recordings should be possible. Furthermore, implantation will provide better signal quality, higher robustness to artefacts, and thus enhanced classification accuracy. Approach. In an initial project, three additional epidural electrodes were temporarily implanted during the surgical procedure. After surgery, different auditory evoked potentials (AEPs) were recorded both invasively (epidural) and using surface electrodes, with invasively recorded signals demonstrated as being markedly superior. In this present analysis, cortical evoked response audiometry (CERA) signals recorded in seven patients were used for single-trial classification of sounds with different intensities. For classification purposes, we used shrinkage-regularized linear discriminant analysis (sLDA). Clinical speech perception scores were also investigated. Main results. Analysis of CERA data from different subjects showed single-trial classification accuracies of up to 99.2% for perceived vs. non-perceived sounds. Accuracies of up to 89.1% were achieved in classification of sounds perceived at different intensities. Highest classification accuracies were achieved by means of epidural recordings. Required loudness differences seemed to correspond to speech perception in noise. Significance. The proposed epidural recording approach showed good classification accuracy into sound perceived and not perceived when the best-performing electrodes were selected. Classifying different levels of sound stimulation accurately proved more challenging. At present, the methods explored in this study would not be sufficiently reliable to allow automated closed-loop control of CI parameters. However, our findings are an important initial contribution towards improving applicability of closed auditory loops and for next-generation automatic fitting approaches.
- 8 March 2022
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 19 (2) , 026002
Open AccessTowards single-trial classification of invasively recorded auditory evoked potentials in cochlear implant users
Objective. One promising approach towards further improving cochlear implants (CI) is to use brain signals controlling the device in order to close the auditory loop. Initial electroencephalography (EEG) studies have already shown promising results. However, they are based on noninvasive measurements, whereas implanted electrodes are expected to be more convenient in terms of everyday-life usability. If additional measurement electrodes were implanted during CI surgery, then invasive recordings should be possible. Furthermore, implantation will provide better signal quality, higher robustness to artefacts, and thus enhanced classification accuracy. Approach. In an initial project, three additional epidural electrodes were temporarily implanted during the surgical procedure. After surgery, different auditory evoked potentials (AEPs) were recorded both invasively (epidural) and using surface electrodes, with invasively recorded signals demonstrated as being markedly superior. In this present analysis, cortical evoked response audiometry (CERA) signals recorded in seven patients were used for single-trial classification of sounds with different intensities. For classification purposes, we used shrinkage-regularized linear discriminant analysis (sLDA). Clinical speech perception scores were also investigated. Main results. Analysis of CERA data from different subjects showed single-trial classification accuracies of up to 99.2% for perceived vs. non-perceived sounds. Accuracies of up to 89.1% were achieved in classification of sounds perceived at different intensities. Highest classification accuracies were achieved by means of epidural recordings. Required loudness differences seemed to correspond to speech perception in noise. Significance. The proposed epidural recording approach showed good classification accuracy into sound perceived and not perceived when the best-performing electrodes were selected. Classifying different levels of sound stimulation accurately proved more challenging. At present, the methods explored in this study would not be sufficiently reliable to allow automated closed-loop control of CI parameters. However, our findings are an important initial contribution towards improving applicability of closed auditory loops and for next-generation automatic fitting approaches.
- Open Access
- 18 December 2020
- Published by Springer Nature in European Archives of Oto-Rhino-Laryngology
- Vol. 278 (11) , 4187-4197
Monitoring of the auditory pathway maturation after early intervention during the first year of life in infants with sensorineural hearing loss
Purpose: The objective of this study was to investigate the auditory pathway maturation monitored by auditory brainstem responses (ABR) in infants with hearing loss during the first year of life. ABR were used to estimate hearing thresholds and the effect of early intervention strategies using hearing aids (HA). Methods: Click-evoked ABRs were measured in 102 infants aged from 0 to 12 months to determine their individual auditory threshold. Early therapy intervention was recommended before 12 months of age and analyzed. To evaluate the effect of hearing amplification on auditory maturation, different subgroups of infants with moderate hearing loss were analyzed and the auditory pathway maturation was determined based on IPL I–V shortening. Results: Overall, 110 ears (54.0% of 204 ears) with mild to profound HL showed threshold changes of 10 dB up to 60 dB in the follow-up ABR testing. HA were prescribed at the age of 3.8 ± 3.9 months. Cochlear implantation (CI) was performed in cases of repeated profound HL at the age of 9.9 months ± 4.5 months. A significant shortening of IPL I–V in all subgroups of infants (with and without risk factors) who received HA was shown and assumed auditory pathway maturation. Conclusion: An early intervention using optimally fitted HA influenced auditory pathway maturation and may lead to improvements of hearing thresholds during the first year of life in infants. This study underscores the importance of not only providing HAs to infants, but also controlling for hearing threshold changes ensuring that HAs provide the optimal level of intervention or CI is indicated.
- 18 December 2020
- Published by Springer Nature in European Archives of Oto-Rhino-Laryngology
- Vol. 278 (11) , 4187-4197
Open AccessMonitoring of the auditory pathway maturation after early intervention during the first year of life in infants with sensorineural hearing loss
Purpose: The objective of this study was to investigate the auditory pathway maturation monitored by auditory brainstem responses (ABR) in infants with hearing loss during the first year of life. ABR were used to estimate hearing thresholds and the effect of early intervention strategies using hearing aids (HA). Methods: Click-evoked ABRs were measured in 102 infants aged from 0 to 12 months to determine their individual auditory threshold. Early therapy intervention was recommended before 12 months of age and analyzed. To evaluate the effect of hearing amplification on auditory maturation, different subgroups of infants with moderate hearing loss were analyzed and the auditory pathway maturation was determined based on IPL I–V shortening. Results: Overall, 110 ears (54.0% of 204 ears) with mild to profound HL showed threshold changes of 10 dB up to 60 dB in the follow-up ABR testing. HA were prescribed at the age of 3.8 ± 3.9 months. Cochlear implantation (CI) was performed in cases of repeated profound HL at the age of 9.9 months ± 4.5 months. A significant shortening of IPL I–V in all subgroups of infants (with and without risk factors) who received HA was shown and assumed auditory pathway maturation. Conclusion: An early intervention using optimally fitted HA influenced auditory pathway maturation and may lead to improvements of hearing thresholds during the first year of life in infants. This study underscores the importance of not only providing HAs to infants, but also controlling for hearing threshold changes ensuring that HAs provide the optimal level of intervention or CI is indicated.
- Open Access
- 1 May 2020
- Published by Georg Thieme Verlag KG in Laryngo-Rhino-Otologie
- Vol. 99 (S 02)
Cochleäres Monitoring während und nach CI-Insertion mittels intracochleär abgeleiteter Elektrocochleographie
Einleitung Um bei CI-Insertionen vorhandenes Restgehör zu erhalten, ist es wünschenswert, ein intraoperatives Monitoring der Cochlea durchzuführen. Ein vielversprechender Ansatz ist die Messung von Cochleären Mikrophonpotentialen (CM) mittels Elektrochleographie (ECochG). Methode Während der Insertion hörerhaltender CI-Elektroden wurden die Potentiale intracochleär über die CI-Elektrode auf Kontakt 1 abgeleitet. Nach der Insertion wurde auf verschiedenen Elektrodenkontakten abgeleitet. Die Stimulation erfolgte akustisch mit 500 Hz-Tonbursts und für die Aufzeichnung wurde die klinische CI Software (Maestro, MED-EL) verwendet. Nach 6 Monaten wurde die Aufzeichnung über die verschiedenen Kontakte wiederholt. Die Elektrodenlage während der Insertion wurde mittels präoperativer Bildgebung (CT) und mathematischer Modellbildung abgeschätzt, die postoperative Lage mittels postoperativer Bildgebung (DVT) gemessen. Aktuell wurden 6 Patienten in die Untersuchung eingeschlossen. Ergebnisse In den meisten Fällen stieg die Potentialamplitude während der Insertion. Bei Patienten mit gutem Restgehör wurden sowohl intra- als auch postoperativ die größten Amplituden auf Elektrodenkontakten gemessen, die am Nächsten zum Generator der Stimulationsfrequenz lagen. Schlußfolgerung Die intracochleäre ECochG ist sowohl während als auch nach der Insertion sehr gut möglich und scheint konsistente Ergebnisse zur Lage der Elektrode in der Cochlea zu liefern. Poster-PDF A-1928.PDF Publication Date: 10 June 2020 (online) © . © Georg Thieme Verlag KG Stuttgart · New York
- 1 May 2020
- Published by Georg Thieme Verlag KG in Laryngo-Rhino-Otologie
- Vol. 99 (S 02)
Open AccessCochleäres Monitoring während und nach CI-Insertion mittels intracochleär abgeleiteter Elektrocochleographie
Einleitung Um bei CI-Insertionen vorhandenes Restgehör zu erhalten, ist es wünschenswert, ein intraoperatives Monitoring der Cochlea durchzuführen. Ein vielversprechender Ansatz ist die Messung von Cochleären Mikrophonpotentialen (CM) mittels Elektrochleographie (ECochG). Methode Während der Insertion hörerhaltender CI-Elektroden wurden die Potentiale intracochleär über die CI-Elektrode auf Kontakt 1 abgeleitet. Nach der Insertion wurde auf verschiedenen Elektrodenkontakten abgeleitet. Die Stimulation erfolgte akustisch mit 500 Hz-Tonbursts und für die Aufzeichnung wurde die klinische CI Software (Maestro, MED-EL) verwendet. Nach 6 Monaten wurde die Aufzeichnung über die verschiedenen Kontakte wiederholt. Die Elektrodenlage während der Insertion wurde mittels präoperativer Bildgebung (CT) und mathematischer Modellbildung abgeschätzt, die postoperative Lage mittels postoperativer Bildgebung (DVT) gemessen. Aktuell wurden 6 Patienten in die Untersuchung eingeschlossen. Ergebnisse In den meisten Fällen stieg die Potentialamplitude während der Insertion. Bei Patienten mit gutem Restgehör wurden sowohl intra- als auch postoperativ die größten Amplituden auf Elektrodenkontakten gemessen, die am Nächsten zum Generator der Stimulationsfrequenz lagen. Schlußfolgerung Die intracochleäre ECochG ist sowohl während als auch nach der Insertion sehr gut möglich und scheint konsistente Ergebnisse zur Lage der Elektrode in der Cochlea zu liefern. Poster-PDF A-1928.PDF Publication Date: 10 June 2020 (online) © . © Georg Thieme Verlag KG Stuttgart · New York
- Open Access
- 30 July 2019
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 16 (5) , 056008
Epidural recordings in cochlear implant users
Objective. In the long term it is desirable for CI users to control their device via brain signals. A possible strategy is the use of auditory evoked potentials (AEPs). Several studies have shown the suitability of auditory paradigms for such an approach. However, these investigations are based on non-invasive recordings. When thinking about everyday life applications, it would be more convenient to use implanted electrodes for signal acquisition. Ideally, the electrodes would be directly integrated into the CI. Further it is to be expected that invasively recorded signals have higher signal quality and are less affected by artifacts. Approach. In this project we investigated the feasibility of implanting epidural electrodes temporarily during CI surgery and the possibility to record AEPs in the course of several days after implantation. Intraoperatively, auditory brainstem responses were recorded, whereas various kinds of AEPs were recorded postoperatively. After a few days the epidural electrodes were removed. Main results. Data sets of ten subjects were obtained. Invasively recorded potentials were compared subjectively and objectively to clinical standard recordings using surface electrodes. Especially the cortical evoked response audiometry depicted clearer N1 waves for the epidural electrodes which were also visible at lower stimulation intensities compared to scalp electrodes. Furthermore the signal was less disturbed by artifacts. The objective quality measure (based on data sets of six patients) showed a significant better signal quality for the epidural compared to the scalp recordings. Significance. Altogether the approach revealed to be feasible and well tolerated by the patients. The epidural recordings showed a clearly better signal quality than the scalp recordings with AEPs being clearer recognizable. The results of the present study suggest that including epidural recording electrodes in future CI systems will improve the everyday life applicability of auditory closed loop systems for CI subjects.
- 30 July 2019
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 16 (5) , 056008
Open AccessEpidural recordings in cochlear implant users
Objective. In the long term it is desirable for CI users to control their device via brain signals. A possible strategy is the use of auditory evoked potentials (AEPs). Several studies have shown the suitability of auditory paradigms for such an approach. However, these investigations are based on non-invasive recordings. When thinking about everyday life applications, it would be more convenient to use implanted electrodes for signal acquisition. Ideally, the electrodes would be directly integrated into the CI. Further it is to be expected that invasively recorded signals have higher signal quality and are less affected by artifacts. Approach. In this project we investigated the feasibility of implanting epidural electrodes temporarily during CI surgery and the possibility to record AEPs in the course of several days after implantation. Intraoperatively, auditory brainstem responses were recorded, whereas various kinds of AEPs were recorded postoperatively. After a few days the epidural electrodes were removed. Main results. Data sets of ten subjects were obtained. Invasively recorded potentials were compared subjectively and objectively to clinical standard recordings using surface electrodes. Especially the cortical evoked response audiometry depicted clearer N1 waves for the epidural electrodes which were also visible at lower stimulation intensities compared to scalp electrodes. Furthermore the signal was less disturbed by artifacts. The objective quality measure (based on data sets of six patients) showed a significant better signal quality for the epidural compared to the scalp recordings. Significance. Altogether the approach revealed to be feasible and well tolerated by the patients. The epidural recordings showed a clearly better signal quality than the scalp recordings with AEPs being clearer recognizable. The results of the present study suggest that including epidural recording electrodes in future CI systems will improve the everyday life applicability of auditory closed loop systems for CI subjects.
- Open Access
- 1 January 2019
- Published by SAGE Publications in Trends in Hearing
- Vol. 23
Monitoring of the Inner Ear Function During and After Cochlear Implant Insertion Using Electrocochleography
To preserve residual hearing during cochlear implant (CI) surgery, it is desirable to use intraoperative monitoring of inner ear function (cochlear monitoring), especially during electrode insertion. A promising method is electrocochleography (ECochG). Within this project, the relations between ongoing responses (ORs), recorded extra- and intracochlearly (EC and IC), and preservation of residual hearing were investigated. Before, during, and after insertion of hearing preservation electrodes, intraoperative ECochG recordings were performed EC using a cotton wick electrode and after insertion also IC using the CI electrode (MED-EL) and a research software tool. The stimulation was delivered acoustically using low frequency tone bursts. The recordings were conducted in 10 adult CI recipients. The amplitudes of IC ORs were detected to be larger than EC ORs. Intraoperative EC thresholds correlated highly to preoperative audiometric thresholds at 1000 Hz, IC thresholds highly at 250 Hz and 500 Hz. The correlations of both intraoperative ECochG recordings to postoperative pure tone thresholds were low. When measured postoperatively at the same appointments, IC OR thresholds correlated highly to audiometric pure tone thresholds. For all patients, it was possible to record ORs during or directly after electrode insertion. Consequently, we conclude that we did not observe any cases with severe IC trauma. Delayed hearing loss could not be predicted with our method. Nevertheless, intraoperative ECochG recordings are a promising tool to gain further insight into mechanisms impacting residual hearing. Postoperatively recorded IC OR thresholds seem to be a reliable tool for frequency specific hearing threshold estimation.
- 1 January 2019
- Published by SAGE Publications in Trends in Hearing
- Vol. 23
Open AccessMonitoring of the Inner Ear Function During and After Cochlear Implant Insertion Using Electrocochleography
To preserve residual hearing during cochlear implant (CI) surgery, it is desirable to use intraoperative monitoring of inner ear function (cochlear monitoring), especially during electrode insertion. A promising method is electrocochleography (ECochG). Within this project, the relations between ongoing responses (ORs), recorded extra- and intracochlearly (EC and IC), and preservation of residual hearing were investigated. Before, during, and after insertion of hearing preservation electrodes, intraoperative ECochG recordings were performed EC using a cotton wick electrode and after insertion also IC using the CI electrode (MED-EL) and a research software tool. The stimulation was delivered acoustically using low frequency tone bursts. The recordings were conducted in 10 adult CI recipients. The amplitudes of IC ORs were detected to be larger than EC ORs. Intraoperative EC thresholds correlated highly to preoperative audiometric thresholds at 1000 Hz, IC thresholds highly at 250 Hz and 500 Hz. The correlations of both intraoperative ECochG recordings to postoperative pure tone thresholds were low. When measured postoperatively at the same appointments, IC OR thresholds correlated highly to audiometric pure tone thresholds. For all patients, it was possible to record ORs during or directly after electrode insertion. Consequently, we conclude that we did not observe any cases with severe IC trauma. Delayed hearing loss could not be predicted with our method. Nevertheless, intraoperative ECochG recordings are a promising tool to gain further insight into mechanisms impacting residual hearing. Postoperatively recorded IC OR thresholds seem to be a reliable tool for frequency specific hearing threshold estimation.