VDVincenzo D'ELia

Vincenzo D'ELia

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Vincenzo D'ELia has a total of 38 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Excess noise of metrology-grade quantum Hall effect devices

    by Luca Callegaro, Alessandro Cultrera, Vincenzo D’ELia, Emanuele Enrico, Juan Medved, Martina Marzano

    Low-frequency excess noise serves as a sensitive probe of dissipation in quantum Hall effect (QHE) devices, providing an alternative path to verify the approach of the quantization condition. This work demonstrates the technical feasibility of performing low-frequency (100 mHz to tens of Hz) excess voltage noise measurements on metrology-grade GaAs and epitaxial graphene QHE devices within a cryogen-free dilution refrigerator, using a two-channel correlation spectrum analyzer. Outside the quantized regime, voltage spectra are dominated by flicker noise, which is strongly suppressed as the dissipationless state is established. Cross-correlation measurements between different voltage terminals provide data that can qualify physical models about the origin of $1/f$ 1 / f noise in graphene devices. The current setup achieves a quantization status assessment sensitivity of 10 −5 in relative deviation, highlighting its potential utility for assessing integrated circuits like quantum Hall array resistance standards, where direct access to the longitudinal resistance of the individual elements is unavailable.

  • Open Access

    A Study on the Thermal Hysteresis of Traveling Inductance Standards

    by Luca Callegaro, Vincenzo D’eLia, Martina Marzano, Massimo Ortolano, M. Florian Beug, Harald Bothe

    The international equivalence of measurement standards and of the calibration and measurement capabilities of National Metrology Institutes is demonstrated through international intercomparisons. The comparison CCEM-K3.2018 “Inductance at 10mH and 1 kHz” is under preparation. To verify the uncertainty claims of the participant institutes, travelling standards of unprecedented level of stability are required. INRIM and PTB characterised several General Radio 1482 inductance standards versus large temperature steps that may occur during air carrier transportation. This work reports on the thermal hysteresis manifested by these standards, which may impact on the uncertainty of the reference value of the CCEM-K3 and other future international and interlaboratory comparisons.


  • Open Access

    An International Trilateral Comparison Among the Newest Generations of Digital and Josephson Impedance Bridges

    by Massimo Ortolano, Martina Marzano, Frédéric Overney, Ali L. Eichenberger, Jan Kucera, Vincenzo D'ELia, Lucie Bartova, Juan Medved, Luca Callegaro

    This work reports and thoroughly discusses the results of an onsite trilateral comparison between a dual Josephson impedance bridge developed by METAS and the electronic fully digital impedance bridges developed by CMI and INRIMPOLITO. The target accuracies of the bridges are at the level of 10-9 to 10-8 for the former and at the level of parts in $10^{7}$ for the latter. The bridges were tested with $R\text {:}R$ and $R\text {:}C$ standards, with nominal magnitudes of $\mathrm {12.9~\text {k}\Omega }$ , and with a quantum Hall resistance standard, in conditions suitable for the primary direct realization of the impedance units ohm and farad from ac quantum Hall resistance standards or from ac/dc calculable transfer resistance standards calibrated against dc quantum Hall resistance standards. The results were fully compatible at the expected level of uncertainty for what concerns the magnitude ratio, but phase measurements with $R\text {:}C$ standards showed some incompatibilities.


  • Open Access

    Virtual Training Laboratory for Primary Impedance Metrology

    by Janusz Kaczmarek, Massimo Ortolano, Oliver Power, Jan Kucera, Luca Callegaro, Vincenzo D'ELia, Martina Marzano, Robert Walsh, Miroslaw Koziol, Ryszard Rybski

    This paper presents the concept and some aspects of the physical implementation of a virtual training laboratory in the field of primary impedance metrology. The creation of a virtual training laboratory provides a novel method of disseminating metrological knowledge and expertise in a practical way and at a low cost. It will expose new users to the live experience of operating a digital impedance bridge thus helping to encourage the uptake of this novel and useful impedance measurement technology. The virtual training laboratory was developed as part of the EMPIR projects VersICal 17RPT04, A versatile electrical impedance calibration laboratory based on digital impedance bridges , and GIQS 18SIB07, Graphene impedance quantum standard .


  • Open Access

    Primary Realization of Inductance and Capacitance Scales With a Fully Digital Bridge

    by Martina Marzano, Vincenzo D'ELia, Massimo Ortolano, Luca Callegaro

    This paper describes an automated electronic fully-digital bridge for the comparison of four-terminal-pair impedance standards in the audio frequency range. The bridge relative accuracy, which is on the order of 10 -6 , makes it suitable as a reference bridge for the realization of primary scales of inductance and capacitance in metrology institutes and calibration laboratories. The performances of this bridge were validated by comparing the results of the calibrations of inductance and capacitance standards with those obtained from an existing analog reference system based on the three-voltage method. The paper also reports the results of this validation.


  • Design and development of a coaxial cryogenic probe for precision measurements of the quantum Hall effect in the AC regime

    by Martina Marzano, Ngoc Thanh Mai Tran, Vincenzo D'ELia, Danilo Serazio, Emanuele Enrico, Massimo Ortolano, Klaus Pierz, Jan Kucera, Luca Callegaro

    The quantum Hall effect is the basis for the realisation of the resistance and impedance units in the International System of units since 2019. This paper describes a cryogenic probe that allows to set graphene Hall devices in quantisation conditions in a helium bath (4.2 K) and magnetic fields up to 6 T, to perform precision measurements in the AC regime with impedance bridges. The probe has a full coaxial wiring, isolated from the probe structure, and holds the device in a TO-8 socket. First, characterization experiments are reported on a GaAs device, showing quantisation at 5.5 T. In the AC regime, multiple-series connections will be employed to minimize the residual error, quantified by electrical modelling of the probe.


  • A new calibration setup for lock-in amplifiers in the low frequency range and its validation in a bilateral comparison

    by Alessandro Cultrera, David Corminboeuf, Vincenzo D’elia, Ngoc Thanh Mai Tran, Luca Callegaro, Massimo Ortolano

    This paper addresses the calibration of lock-in amplifiers in the low frequency range. A simple but effective calibration setup implemented at INRIM is described. This includes a stable low-voltage source, composed of a digital sine wave generator and a cascade of two voltage dividers, one inductive and one resistive. The magnitude error is the lock-in magnitude error, which can be determined with an uncertainty of the order of 10 −4 or better, that is, two orders of magnitude lower than the typical lock-in accuracy specification. The system can operate with an input voltage from 0.1 µV to 10 µV and a frequency from a few hertz to about 1 kHz. The performances of the calibration setup were evaluated at 1 µV and 10 μV at 20 Hz and 103 Hz and compared with those of another existing setup, implemented at METAS, through a direct comparison in the framework of an EURAMET research project.


  • Comparison of Low DC Current Traceability Methods and Gas Capacitors AC–DC Dependence

    by Luca Callegaro, Cristina Cassiago, Vincenzo D'ELia, Enrico Gasparotto, Emanuele Enrico, Martin Gotz

    This article compares two instruments for the traceable measurement of dc low currents, a custom capacitance–voltage ( $C\text{-} V$ ) source and the ultrastable low-current amplifier (ULCA), a commercial precision transresistance amplifier. The instruments are calibrated through independent traceability routes. The comparison base relative accuracy is in the $10^{-6}\!-\!10^{-5}$ range. Differences between the two instrument readings, in the $10^{-5}$ range, are interpreted as an effect of the frequency dependence of the capacitor employed in the $C\text{-} V$ source. Such frequency dependence can also affect primary metrology experiments in other fields.


  • Open Access

    A fully digital bridge towards the realization of the farad from the quantum Hall effect

    by Martina Marzano, Massimo Ortolano, Vincenzo D’eLia, André Müller, Luca Callegaro

    This paper presents the implementation of an electronic fully-digital impedance bridge optimized for RC comparisons with equal impedance magnitudes, together with an evaluation of the uncertainty. This bridge has been designed with the goal of realizing the farad directly from the quantum Hall effect with a bridge uncertainty component at the 10−7 level. Thanks to its simple design, ease of operation and affordability, this bridge is suitable to be industrially manufactured. Together with the increasing availability of graphene quantum Hall resistance standards, this can provide an affordable quantum realization of the unit farad for metrology institutes and calibration centres. In this paper we present the uncertainty budget of an example measurement and the results of the validation of the bridge against a suitably modified version of the traceability chain of the Italian national standard of capacitance. The combined uncertainty of the bridge resulted from repeated measurements (overall measurement time of about 200 min) is 9.2 × 10−8, suitable for the primary realization of the unit of capacitance from a quantized Hall resistance standard. The crosstalk among the channels of the electrical generator is the most significant uncertainty component, possibly reducible with internal shielding and filtering of the electronic generator.


  • Open Access

    A Comprehensive Analysis of Error Sources in Electronic Fully Digital Impedance Bridges

    by Massimo Ortolano, Martina Marzano, Vincenzo D'Elia, Ngoc Thanh Mai Tran, Ryszard Rybski, Janusz Kaczmarek, Miroslaw Koziol, Krzysztof Musiol, Andreas Elmholdt Christensen, Luca Callegaro, et al.

    Fully-digital impedance bridges are emerging as measuring instruments for primary electrical impedance metrology and the realization of impedance units and scales. This paper presents a comprehensive analysis of electronic fully-digital impedance bridges, for both generating (based on digital-toanalog converters) and digitizing (based on analog-to-digital converters) bridges. The sources of measurement error are analyzed in detail and expressed by explicit mathematical formulæ ready to be applied to the specific bridge and measurement case of interest. The same can be employed also as a basis to optimize the design and the operating parameters of digital bridges, and to evaluate the measurement uncertainty. A practical application of the analysis to the digital bridges developed and measurements performed in the framework of an international research project is presented.