MMMartina Marzano

Martina Marzano

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Martina Marzano has a total of 86 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Excess noise of metrology-grade quantum Hall effect devices

    by Luca Callegaro, Alessandro Cultrera, Vincenzo D’ELia, Emanuele Enrico, Juan Medved, Martina Marzano

    Low-frequency excess noise serves as a sensitive probe of dissipation in quantum Hall effect (QHE) devices, providing an alternative path to verify the approach of the quantization condition. This work demonstrates the technical feasibility of performing low-frequency (100 mHz to tens of Hz) excess voltage noise measurements on metrology-grade GaAs and epitaxial graphene QHE devices within a cryogen-free dilution refrigerator, using a two-channel correlation spectrum analyzer. Outside the quantized regime, voltage spectra are dominated by flicker noise, which is strongly suppressed as the dissipationless state is established. Cross-correlation measurements between different voltage terminals provide data that can qualify physical models about the origin of $1/f$ 1 / f noise in graphene devices. The current setup achieves a quantization status assessment sensitivity of 10 −5 in relative deviation, highlighting its potential utility for assessing integrated circuits like quantum Hall array resistance standards, where direct access to the longitudinal resistance of the individual elements is unavailable.

  • Open Access

    Companion guide to the revised technical guidelines for reliable dc measurements of the quantized Hall resistance for graphene-based devices

    by Albert F Rigosi, Hansjörg Scherer, Mathieu Taupin, Luca Callegaro, Hans He, Susmit Kumar, Ali Eichenberger, Mattias Kruskopf, Yanfei Yang, Martina Marzano, et al.

    This companion guide revises and expands upon the established technical guidelines for reliable direct current measurements of the quantized Hall resistance, adapting them to the unique characteristics of epitaxial graphene. Graphene has emerged as a viable alternative to traditional Gallium Arsenide heterostructures for metrological applications due to its relaxed operating conditions. These less demanding requirements facilitate the use of low-cost, compact cryomagnet platforms, which is expected to broaden the deployment of primary resistance standards to National Metrology Institutes and other laboratories with limited resources. The guide explores the specific challenges and considerations of epitaxial graphene devices, including aspects of device choice, cooling and handling, contact resistance, conditions of quantization, and general measurements of the quantized Hall resistance. The presented details should assist those seeking to conduct rigorous characterization procedures to verify device integrity, ultimately contributing to a global effort to formally accept graphene-based devices as reliable primary resistance standards.

  • Open Access

    Conductivity space isotherm behavior in quantum anomalous Hall devices

    by N. T. M. Tran, V. Ortiz Jimenez, M. Musso, L. K. Rodenbach, M. P. Andersen, H. M. Hill, P. Zhang, L. Tai, K. L. Wang, M. Marzano, et al.

    The quantum Hall effect (QHE) has enhanced accessibility to measure and disseminate electrical units, owed in part to the recently redefined International System of Units in 2019. Graphene remains one of the preferred options to realize the ohm despite the limitations of high magnetic fields to produce a robust QHE. Topological insulators, on the other hand, show promise in providing quantized resistance via the quantum anomalous Hall effect, a phenomenon that removes the need for magnetic fields during operation. To optimize future devices for metrological applications, it is important to gain a better understanding of magnetically doped topological insulators like Cr-doped bismuth antimony telluride. The application of differential conductivity space analyses offers a more sensitive way to analyze the data and distinguish between 2D and 3D transport behaviors. This is particularly important in thin films, where the transition between 2D and 3D behavior can be subtle. The ability to confidently determine the dimensionality of the transport is crucial for selecting appropriate theoretical models for future device optimization. Furthermore, this work identifies variable range hopping as the dominant transport mechanism in the 2D regime using a rigorous statistical analysis (via the Bayes factor). These elements assist in the understanding of microscopic processes that govern charge transport in these materials.


  • Open Access

    A Study on the Thermal Hysteresis of Traveling Inductance Standards

    by Luca Callegaro, Vincenzo D’eLia, Martina Marzano, Massimo Ortolano, M. Florian Beug, Harald Bothe

    The international equivalence of measurement standards and of the calibration and measurement capabilities of National Metrology Institutes is demonstrated through international intercomparisons. The comparison CCEM-K3.2018 “Inductance at 10mH and 1 kHz” is under preparation. To verify the uncertainty claims of the participant institutes, travelling standards of unprecedented level of stability are required. INRIM and PTB characterised several General Radio 1482 inductance standards versus large temperature steps that may occur during air carrier transportation. This work reports on the thermal hysteresis manifested by these standards, which may impact on the uncertainty of the reference value of the CCEM-K3 and other future international and interlaboratory comparisons.


  • Open Access

    An International Trilateral Comparison Among the Newest Generations of Digital and Josephson Impedance Bridges

    by Massimo Ortolano, Martina Marzano, Frédéric Overney, Ali L. Eichenberger, Jan Kucera, Vincenzo D'ELia, Lucie Bartova, Juan Medved, Luca Callegaro

    This work reports and thoroughly discusses the results of an onsite trilateral comparison between a dual Josephson impedance bridge developed by METAS and the electronic fully digital impedance bridges developed by CMI and INRIMPOLITO. The target accuracies of the bridges are at the level of 10-9 to 10-8 for the former and at the level of parts in $10^{7}$ for the latter. The bridges were tested with $R\text {:}R$ and $R\text {:}C$ standards, with nominal magnitudes of $\mathrm {12.9~\text {k}\Omega }$ , and with a quantum Hall resistance standard, in conditions suitable for the primary direct realization of the impedance units ohm and farad from ac quantum Hall resistance standards or from ac/dc calculable transfer resistance standards calibrated against dc quantum Hall resistance standards. The results were fully compatible at the expected level of uncertainty for what concerns the magnitude ratio, but phase measurements with $R\text {:}C$ standards showed some incompatibilities.


  • Open Access

    On the calibration of DC resistance ratio bridges

    by M. Marzano, C. Cassiago, V. D’eLia, E. Gasparotto, L. Callegaro


  • Open Access

    Metrological assessment of DC current comparator resistance bridges

    by M. Marzano, P.P. Capra, C. Cassiago, V. D’eLia, E. Gasparotto, L. Callegaro


  • Open Access

    Virtual Training Laboratory for Primary Impedance Metrology

    by Janusz Kaczmarek, Massimo Ortolano, Oliver Power, Jan Kucera, Luca Callegaro, Vincenzo D'ELia, Martina Marzano, Robert Walsh, Miroslaw Koziol, Ryszard Rybski

    This paper presents the concept and some aspects of the physical implementation of a virtual training laboratory in the field of primary impedance metrology. The creation of a virtual training laboratory provides a novel method of disseminating metrological knowledge and expertise in a practical way and at a low cost. It will expose new users to the live experience of operating a digital impedance bridge thus helping to encourage the uptake of this novel and useful impedance measurement technology. The virtual training laboratory was developed as part of the EMPIR projects VersICal 17RPT04, A versatile electrical impedance calibration laboratory based on digital impedance bridges , and GIQS 18SIB07, Graphene impedance quantum standard .


  • Open Access

    Primary Realization of Inductance and Capacitance Scales With a Fully Digital Bridge

    by Martina Marzano, Vincenzo D'ELia, Massimo Ortolano, Luca Callegaro

    This paper describes an automated electronic fully-digital bridge for the comparison of four-terminal-pair impedance standards in the audio frequency range. The bridge relative accuracy, which is on the order of 10 -6 , makes it suitable as a reference bridge for the realization of primary scales of inductance and capacitance in metrology institutes and calibration laboratories. The performances of this bridge were validated by comparing the results of the calibrations of inductance and capacitance standards with those obtained from an existing analog reference system based on the three-voltage method. The paper also reports the results of this validation.


  • Open Access

    PTB–INRIM comparison of novel digital impedance bridges with graphene impedance quantum standards

    by Martina Marzano, Yaowaret Pimsut, Mattias Kruskopf, Yefei Yin, Marco Kraus, Vincenzo D’eLia, Luca Callegaro, Massimo Ortolano, Stephan Bauer, Ralf Behr

    This paper describes an onsite comparison of two different digital impedance bridges when performing measurements on a quantum Hall resistance standard with the purpose of realizing the SI unit of capacitance, the farad. In the EMPIR Joint Research Project 18SIB07 GIQS, graphene impedance quantum standards, the Physikalisch-Technische Bundesanstalt (PTB), Germany, developed a Josephson impedance bridge, and the Istituto Nazionale di Ricerca Metrologica (INRIM) and the Politecnico di Torino (POLITO), Italy, developed an electronic digital impedance bridge. The former is based on Josephson waveform generators and the latter on an electronic waveform synthesizer. The INRIM–POLITO impedance bridge was moved to PTB and the two bridges were compared by measuring both temperature-controlled standards and a graphene AC quantized Hall resistance (QHR) standard. The uncertainties for the calibration of 10 nF capacitance standards at 1233 Hz are within 1 × 10−8 for the PTB’s bridge and around 1 × 10−7 for the INRIM–POLITO’s bridge. The comparison mutually validates the two bridges within the combined uncertainty. The result confirms that digital impedance bridges allow the realization of the SI farad from the QHR with uncertainties comparable with the best calibration capabilities of the BIPM and the major National Metrology Institutes.