Stanislav Musil
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Stanislav Musil has a total of 119 co-authors. Here are the top co-authors by number of shared publications:
- Jan Kratzer
Institute of Analytical Chemistry of the Czech Academy of Sciences, Veveří 97, 602 00, Brno, Czech Republic
13 shared publications Jiří Dědina
13 shared publicationsTomáš Matoušek
Institute of Analytical Chemistry of the Czech Academy of Sciences, Brno, Czech Republic
11 shared publications- Tomáš Matoušek
Institute of Analytical Chemistry of the Czech Academy of Sciences, Veveří 97, 602 00 Brno, Czech Republic
8 shared publications - Jaromír Vyhnanovský
Institute of Analytical Chemistry of the Czech Academy of Sciences, Veveří 97, 602 00 Brno, Czech Republic
6 shared publications - Jiří Dědina
Institute of Analytical Chemistry of the Czech Academy of Sciences, Veveri 97, Brno 602 00, Czech Republic
6 shared publications
Latest Publications
- 20 July 2026
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1421, 345993
Conclusive identification of photochemically generated volatile species of ruthenium, osmium, and rhenium using selected ion flow tube mass spectrometry
- 20 July 2026
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1421, 345993
Conclusive identification of photochemically generated volatile species of ruthenium, osmium, and rhenium using selected ion flow tube mass spectrometry
- Open Access
- 10 February 2026
- Published by Wiley in Journal of Mass Spectrometry
- Vol. 61 (3) , e70033
Selected Ion Flow‐Tube Mass Spectrometry (SIFT‐MS) of Mo(CO) 6 and W(CO) 6 Vapours With Positive and Negative Reagent Ions
Selected ion flow‐tube mass spectrometry (SIFT‐MS) was used to characterise the gas‐phase ion–molecule reactions of the eight standard reagent ions H 3 O + , NO + , O 2 + ˙, OH − , O − ˙, O 2 − ˙, NO 2 − and NO 3 − with molybdenum and tungsten hexacarbonyls, Mo(CO) 6 and W(CO) 6 . These compounds, chosen as model volatile transition‐metal carbonyls, were introduced directly into the SIFT at variable concentrations, and mass spectra were obtained for all reagent ions. Reactions with the positive reagent ions were fast and close to the collisional limit, proceeding mainly by proton transfer (H 3 O + ) or charge transfer (NO + and O 2 + ˙) with little fragmentation. In contrast, negative‐ion reactions were slower and chemically more diverse. O − ˙ and O 2 − ˙ produced sequential oxidation and ligand‐exchange products, MoO x (CO) 6− n − ˙ and WO x (CO) 6− n − ˙, while NO 2 − reacted slowly only with Mo(CO) 6 . Relative rate coefficients normalised to H 3 O + proton transfer were determined. The results establish the feasibility of SIFT‐MS for direct, real‐time detection of transition‐metal carbonyl vapours and clarify their underlying ion–molecule chemistry. Positive‐ion channels offer the most sensitive analytical response, whereas negative‐ion reactions reveal complementary oxidative pathways. This study thus extends SIFT‐MS to a new class of metal–ligand compounds, which are relevant to environmental and occupational monitoring.
- 10 February 2026
- Published by Wiley in Journal of Mass Spectrometry
- Vol. 61 (3) , e70033
Open AccessSelected Ion Flow‐Tube Mass Spectrometry (SIFT‐MS) of Mo(CO) 6 and W(CO) 6 Vapours With Positive and Negative Reagent Ions
Selected ion flow‐tube mass spectrometry (SIFT‐MS) was used to characterise the gas‐phase ion–molecule reactions of the eight standard reagent ions H 3 O + , NO + , O 2 + ˙, OH − , O − ˙, O 2 − ˙, NO 2 − and NO 3 − with molybdenum and tungsten hexacarbonyls, Mo(CO) 6 and W(CO) 6 . These compounds, chosen as model volatile transition‐metal carbonyls, were introduced directly into the SIFT at variable concentrations, and mass spectra were obtained for all reagent ions. Reactions with the positive reagent ions were fast and close to the collisional limit, proceeding mainly by proton transfer (H 3 O + ) or charge transfer (NO + and O 2 + ˙) with little fragmentation. In contrast, negative‐ion reactions were slower and chemically more diverse. O − ˙ and O 2 − ˙ produced sequential oxidation and ligand‐exchange products, MoO x (CO) 6− n − ˙ and WO x (CO) 6− n − ˙, while NO 2 − reacted slowly only with Mo(CO) 6 . Relative rate coefficients normalised to H 3 O + proton transfer were determined. The results establish the feasibility of SIFT‐MS for direct, real‐time detection of transition‐metal carbonyl vapours and clarify their underlying ion–molecule chemistry. Positive‐ion channels offer the most sensitive analytical response, whereas negative‐ion reactions reveal complementary oxidative pathways. This study thus extends SIFT‐MS to a new class of metal–ligand compounds, which are relevant to environmental and occupational monitoring.
- Open Access
- 27 July 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (30) , 16593-16601
Identification of Photochemically Generated Volatile Species of Ruthenium and Osmium Using Direct Analysis in Real Time Mass Spectrometry
Photochemical vapor generation (PVG) was coupled to direct analysis in real time (DART) high-resolution mass spectrometry (HRMS) using N2 as the discharge gas in an attempt to identify unknown volatile carbonyls of Ru and Os generated during the UV photolysis of HCOOH-based photochemical media previously described in the literature. Initial insights into the ambient ionization process in the N2 DART were gained using volatile W(CO)6 and Fe(CO)5, either photochemically generated or introduced as standards from a headspace. In general, significant changes in the original carbonyl structure are observed in both positive and negative ion modes, characterized by the loss of CO group(s), oxidation, hydration, and formation of various adducts derived from N2 used as the discharge gas. Nevertheless, the ions detected under PVG conditions based on dilute or concentrated HCOOH media, preferably in the presence of transition metal mediators, suggest that the generated carbonyls of Ru and Os are mononuclear, contain five carbonyl groups, and are therefore Ru(CO)5 and Os(CO)5. When Co2+ was used as a mediator, some difficulties in identification were encountered because volatile Co(CO)4H was cogenerated with significant efficiency, overloading the DART and HRMS and even resulting in mixed metal carbonyl cluster ions during ionization. Additional experiments with PVG of Os conducted under oxidative conditions using deionized water, dilute HNO3, and dilute H2O2 as the photochemical media confirmed OsO4 as the volatile species. The same volatile species was also identified as the dominant product using dilute CH3COOH with the addition of Fe2+ as a mediator, suggesting the rather oxidative nature of this medium, although some distinct carbonyl/hydrido/methyl or acetato species were also observed. The controversies are discussed as well as other peculiarities of the DART-HRMS technique for the identification of volatile metal carbonyls.
- 27 July 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (30) , 16593-16601
Open AccessIdentification of Photochemically Generated Volatile Species of Ruthenium and Osmium Using Direct Analysis in Real Time Mass Spectrometry
Photochemical vapor generation (PVG) was coupled to direct analysis in real time (DART) high-resolution mass spectrometry (HRMS) using N2 as the discharge gas in an attempt to identify unknown volatile carbonyls of Ru and Os generated during the UV photolysis of HCOOH-based photochemical media previously described in the literature. Initial insights into the ambient ionization process in the N2 DART were gained using volatile W(CO)6 and Fe(CO)5, either photochemically generated or introduced as standards from a headspace. In general, significant changes in the original carbonyl structure are observed in both positive and negative ion modes, characterized by the loss of CO group(s), oxidation, hydration, and formation of various adducts derived from N2 used as the discharge gas. Nevertheless, the ions detected under PVG conditions based on dilute or concentrated HCOOH media, preferably in the presence of transition metal mediators, suggest that the generated carbonyls of Ru and Os are mononuclear, contain five carbonyl groups, and are therefore Ru(CO)5 and Os(CO)5. When Co2+ was used as a mediator, some difficulties in identification were encountered because volatile Co(CO)4H was cogenerated with significant efficiency, overloading the DART and HRMS and even resulting in mixed metal carbonyl cluster ions during ionization. Additional experiments with PVG of Os conducted under oxidative conditions using deionized water, dilute HNO3, and dilute H2O2 as the photochemical media confirmed OsO4 as the volatile species. The same volatile species was also identified as the dominant product using dilute CH3COOH with the addition of Fe2+ as a mediator, suggesting the rather oxidative nature of this medium, although some distinct carbonyl/hydrido/methyl or acetato species were also observed. The controversies are discussed as well as other peculiarities of the DART-HRMS technique for the identification of volatile metal carbonyls.
- Open Access
- 15 May 2025
- Published by Czech Chemical Society in Chemické listy
- Vol. 119 (5) , 294-302
Institute of Analytical Chemistry of the Czech Academy of Sciences – The Past and the Present
This article briefly introduces the Institute of Analytical Chemistry of the Academy of Sciences of the Czech Republic. The introductory part illustrates the historical development of the Institute and characterizes its focus in general. In the following five sections, each of the five scientific departments of the Institute describes selected topics from its current activities.
- 15 May 2025
- Published by Czech Chemical Society in Chemické listy
- Vol. 119 (5) , 294-302
Open AccessInstitute of Analytical Chemistry of the Czech Academy of Sciences – The Past and the Present
This article briefly introduces the Institute of Analytical Chemistry of the Academy of Sciences of the Czech Republic. The introductory part illustrates the historical development of the Institute and characterizes its focus in general. In the following five sections, each of the five scientific departments of the Institute describes selected topics from its current activities.
- Open Access
- 10 February 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (6) , 3545-3553
Sensitive and Spectral Interference-Free Determination of Rhodium by Photochemical Vapor Generation Inductively Coupled Plasma Mass Spectrometry
A sensitive method for Rh determination was developed by coupling photochemical vapor generation (PVG) for sample introduction to inductively coupled plasma mass spectrometry (ICPMS). PVG was conducted in a thin-film flow-through photoreactor operated in a flow injection mode from a photochemical medium comprising 10 M HCOOH. PVG efficiency was substantially enhanced by the addition of 10 mg L-1 Cu2+ and 5 mg L-1 Co2+ as mediators as well as 50 mM NaNO3. The volatile product (likely Rh(CO)4H) was found to be less stable when in prolonged contact with the liquid medium at the output from the photoreactor. Hence, further enhancement was achieved by introducing an Ar carrier gas near the exit of the photoreactor to minimize the interaction of volatile species with the liquid medium. Despite PVG efficiency reaching only 15%, measurement at the ultratrace level (20 ng L-1) was characterized by very good repeatability of peak area response (2.9%) and outstanding limits of detection (13 pg L-1, 6.5 fg absolute) using He in the collision cell. Interferences from potential coexisting metals, inorganic acids, and their anions were investigated. Accuracy was verified by analysis of OREAS 684 (Platinum Group Element Ore) and SRM 2556 (Used Auto Catalyst) following peroxide fusion for sample preparation. Application to the direct analysis of real river and lake water samples and reference materials AQUA-1 and SLRS-6 demonstrated excellent selectivity of the PVG-ICPMS methodology over conventional pneumatic nebulization-ICP(MS)/MS, the results of which were seriously biased by polyatomic interferences, especially from Sr and Cu, despite the use of various reaction/collision cell modes.
- 10 February 2025
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 97 (6) , 3545-3553
Open AccessSensitive and Spectral Interference-Free Determination of Rhodium by Photochemical Vapor Generation Inductively Coupled Plasma Mass Spectrometry
A sensitive method for Rh determination was developed by coupling photochemical vapor generation (PVG) for sample introduction to inductively coupled plasma mass spectrometry (ICPMS). PVG was conducted in a thin-film flow-through photoreactor operated in a flow injection mode from a photochemical medium comprising 10 M HCOOH. PVG efficiency was substantially enhanced by the addition of 10 mg L-1 Cu2+ and 5 mg L-1 Co2+ as mediators as well as 50 mM NaNO3. The volatile product (likely Rh(CO)4H) was found to be less stable when in prolonged contact with the liquid medium at the output from the photoreactor. Hence, further enhancement was achieved by introducing an Ar carrier gas near the exit of the photoreactor to minimize the interaction of volatile species with the liquid medium. Despite PVG efficiency reaching only 15%, measurement at the ultratrace level (20 ng L-1) was characterized by very good repeatability of peak area response (2.9%) and outstanding limits of detection (13 pg L-1, 6.5 fg absolute) using He in the collision cell. Interferences from potential coexisting metals, inorganic acids, and their anions were investigated. Accuracy was verified by analysis of OREAS 684 (Platinum Group Element Ore) and SRM 2556 (Used Auto Catalyst) following peroxide fusion for sample preparation. Application to the direct analysis of real river and lake water samples and reference materials AQUA-1 and SLRS-6 demonstrated excellent selectivity of the PVG-ICPMS methodology over conventional pneumatic nebulization-ICP(MS)/MS, the results of which were seriously biased by polyatomic interferences, especially from Sr and Cu, despite the use of various reaction/collision cell modes.
- Open Access
- 6 January 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (3) , 1241-1250
Efficient Photochemical Vapor Generation from Low Concentration Formic Acid Media
Herein, we report on surprisingly efficient photochemical vapor generation (PVG) of Ru, Re, and especially Ir, achieved from very dilute HCOOH media employing a thin-film flow-through photoreactor operated in flow injection mode. In the absence of added metal ion sensitizers, efficiencies near 20% for Ir and approximately 0.06% for Ru and Re occur in a narrow range of HCOOH concentrations (around 0.01 M), significantly higher than previously reported from conventionally optimized HCOOH concentrations (1-20 M). A substantial enhancement in efficiency, to around 9 and 1.5%, could be realized for Ru and Re, respectively, when 0.005 M HCOONa served as the PVG medium. The addition of metal ion sensitizers (particularly Cd2+ and Co2+) to 0.01 M HCOOH significantly enhanced PVG efficiencies to 17, 2.2, and 81% for Ru, Re, and Ir, respectively. Possible mechanistic aspects occurring in dilute HCOOH media are discussed, wherein this phenomenon is attributed to the action of 185 nm radiation available in the thin-film flow-through photoreactor. An extended study of PVG of Fe, Co, Ni, As, Se, Mo, Rh, Te, W, and Bi from both dilute HCOOH and CH3COOH was undertaken, and several elements for which a similar phenomenon appears were identified (i.e., Co, As, Se, Te, and Bi). Although use of dilute HCOOH media is attractive for practical analytical applications employing PVG, it is less tolerant toward dissolved gases and interferents in the liquid phase due to the likely lower concentrations of free radicals and aquated electrons required for analyte ion reduction and product synthesis.
- 6 January 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (3) , 1241-1250
Open AccessEfficient Photochemical Vapor Generation from Low Concentration Formic Acid Media
Herein, we report on surprisingly efficient photochemical vapor generation (PVG) of Ru, Re, and especially Ir, achieved from very dilute HCOOH media employing a thin-film flow-through photoreactor operated in flow injection mode. In the absence of added metal ion sensitizers, efficiencies near 20% for Ir and approximately 0.06% for Ru and Re occur in a narrow range of HCOOH concentrations (around 0.01 M), significantly higher than previously reported from conventionally optimized HCOOH concentrations (1-20 M). A substantial enhancement in efficiency, to around 9 and 1.5%, could be realized for Ru and Re, respectively, when 0.005 M HCOONa served as the PVG medium. The addition of metal ion sensitizers (particularly Cd2+ and Co2+) to 0.01 M HCOOH significantly enhanced PVG efficiencies to 17, 2.2, and 81% for Ru, Re, and Ir, respectively. Possible mechanistic aspects occurring in dilute HCOOH media are discussed, wherein this phenomenon is attributed to the action of 185 nm radiation available in the thin-film flow-through photoreactor. An extended study of PVG of Fe, Co, Ni, As, Se, Mo, Rh, Te, W, and Bi from both dilute HCOOH and CH3COOH was undertaken, and several elements for which a similar phenomenon appears were identified (i.e., Co, As, Se, Te, and Bi). Although use of dilute HCOOH media is attractive for practical analytical applications employing PVG, it is less tolerant toward dissolved gases and interferents in the liquid phase due to the likely lower concentrations of free radicals and aquated electrons required for analyte ion reduction and product synthesis.
- Open Access
- 4 May 2023
- Published by CSIRO Publishing in Environmental Chemistry
- Vol. 20 (2) , 5-17
Determination of inorganic As, DMA and MMA in marine and terrestrial tissue samples: a consensus extraction approach
Environmental context: Arsenic can be found in all environmental compartments in a large number of chemical forms of varying toxicity. We performed an inter-laboratory comparison study focusing on quantitation of some of the most toxic arsenic forms in seven different biological materials and found very good agreement among the submitted results. Certification of the studied materials will provide suitable quality control samples for environmentally relevant concentrations of arsenic in food products and biota. Rationale: Arsenic (As) speciation analysis in biological matrices has been performed for several decades; however, there are very few matrix certified reference materials available for the validation of analytical methods. The literature data on the mass fractions of As species in the existing certified reference materials are inconsistent and suggest method extraction dependency. Methodology: In the present study, an international round-robin study was organised to identify the possible sources of discrepancies in quantitation of several As species in different matrices of biological reference materials: one plant tissue, three marine and three terrestrial biological tissues. Each participating laboratory was provided with a set of identical calibration standard solutions, and analysed the samples by following a common group extraction method as well as using an in-house protocol. Results: The results showed that significant biases can be introduced by insufficient verification of the analyte’s mass fractions in the calibration standard solutions. The choice of extraction method seems to have very little impact on the quantitation of As species in the studied plant and terrestrial biological tissues. However, following a prescribed extraction method led to significant reduction of uncertainties in more complex samples such as marine animal tissues. Discussion: Some differences in the mass fractions of As species extracted from marine animal tissues in water (with and without H2O2) were observed and should be further investigated. Despite the variety of extraction methods used, very good agreement between reported mass fractions was achieved and the combined consensus values will be published as certified reference values of As species in the studied materials.
- 4 May 2023
- Published by CSIRO Publishing in Environmental Chemistry
- Vol. 20 (2) , 5-17
Open AccessDetermination of inorganic As, DMA and MMA in marine and terrestrial tissue samples: a consensus extraction approach
Environmental context: Arsenic can be found in all environmental compartments in a large number of chemical forms of varying toxicity. We performed an inter-laboratory comparison study focusing on quantitation of some of the most toxic arsenic forms in seven different biological materials and found very good agreement among the submitted results. Certification of the studied materials will provide suitable quality control samples for environmentally relevant concentrations of arsenic in food products and biota. Rationale: Arsenic (As) speciation analysis in biological matrices has been performed for several decades; however, there are very few matrix certified reference materials available for the validation of analytical methods. The literature data on the mass fractions of As species in the existing certified reference materials are inconsistent and suggest method extraction dependency. Methodology: In the present study, an international round-robin study was organised to identify the possible sources of discrepancies in quantitation of several As species in different matrices of biological reference materials: one plant tissue, three marine and three terrestrial biological tissues. Each participating laboratory was provided with a set of identical calibration standard solutions, and analysed the samples by following a common group extraction method as well as using an in-house protocol. Results: The results showed that significant biases can be introduced by insufficient verification of the analyte’s mass fractions in the calibration standard solutions. The choice of extraction method seems to have very little impact on the quantitation of As species in the studied plant and terrestrial biological tissues. However, following a prescribed extraction method led to significant reduction of uncertainties in more complex samples such as marine animal tissues. Discussion: Some differences in the mass fractions of As species extracted from marine animal tissues in water (with and without H2O2) were observed and should be further investigated. Despite the variety of extraction methods used, very good agreement between reported mass fractions was achieved and the combined consensus values will be published as certified reference values of As species in the studied materials.
- 19 April 2023
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 38 (6) , 1213-1223
Chemical vapour generation assisted by Cr 3+ /KCN coupled to atomic fluorescence spectrometry for ultrasensitive determination of cadmium in water and rice samples
A methodology for cadmium determination at ultratrace levels based on chemical vapour generation (CVG) coupled to atomic fluorescence spectrometry (AFS) was developed. Cd volatile species were generated in a four-channel flow injection CVG system by the reaction of the analyte with NaBH4 in a HCl medium in the presence of Cr3+/KCN used as modifiers enhancing the CVG efficiency. An in-house assembled non-dispersive AFS was used as a detector of the volatile species in two types of flame atomizers – the miniature diffusion flame (MDF) and the flame-in-gas-shield (FIGS) atomizers. The atomization conditions were optimized for both atomizers and the tolerance towards interferences from hydride forming elements and mercury was examined. The sensitivity obtained with the FIGS atomizer was approximately twofold higher compared to that with the MDF atomizer; therefore, the FIGS atomizer was selected for further analytical applications, providing an excellent limit of detection of 0.42 ng L−1 Cd (63 fg absolute). The accuracy of the proposed methodology was verified by analyses of certified reference materials of water with various matrix complexities (fresh water SRM 1643f, wastewater ERM-CA713 and seawater CASS-4 and NASS-5) and rice flour SRM 1568b after microwave digestion in a diluted acid medium with very good agreement with certified values. In addition, the practical application was successfully demonstrated by determination of Cd content in three samples of rice and rice flour with excellent agreement with the values obtained by solution nebulization inductively coupled plasma mass spectrometry.
- 19 April 2023
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 38 (6) , 1213-1223
Chemical vapour generation assisted by Cr 3+ /KCN coupled to atomic fluorescence spectrometry for ultrasensitive determination of cadmium in water and rice samples
A methodology for cadmium determination at ultratrace levels based on chemical vapour generation (CVG) coupled to atomic fluorescence spectrometry (AFS) was developed. Cd volatile species were generated in a four-channel flow injection CVG system by the reaction of the analyte with NaBH4 in a HCl medium in the presence of Cr3+/KCN used as modifiers enhancing the CVG efficiency. An in-house assembled non-dispersive AFS was used as a detector of the volatile species in two types of flame atomizers – the miniature diffusion flame (MDF) and the flame-in-gas-shield (FIGS) atomizers. The atomization conditions were optimized for both atomizers and the tolerance towards interferences from hydride forming elements and mercury was examined. The sensitivity obtained with the FIGS atomizer was approximately twofold higher compared to that with the MDF atomizer; therefore, the FIGS atomizer was selected for further analytical applications, providing an excellent limit of detection of 0.42 ng L−1 Cd (63 fg absolute). The accuracy of the proposed methodology was verified by analyses of certified reference materials of water with various matrix complexities (fresh water SRM 1643f, wastewater ERM-CA713 and seawater CASS-4 and NASS-5) and rice flour SRM 1568b after microwave digestion in a diluted acid medium with very good agreement with certified values. In addition, the practical application was successfully demonstrated by determination of Cd content in three samples of rice and rice flour with excellent agreement with the values obtained by solution nebulization inductively coupled plasma mass spectrometry.
- Open Access
- 10 February 2023
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 95 (7) , 3694-3702
Highly Efficient Photochemical Vapor Generation for Sensitive Determination of Iridium by Inductively Coupled Plasma Mass Spectrometry
Herein, we describe the highly efficient photochemical vapor generation (PVG) of a volatile species of Ir (presumably iridium tetracarbonyl hydride) for subsequent detection by inductively coupled plasma mass spectrometry (ICPMS). A thin-film flow-through photoreactor, operated in flow injection mode, provided high efficiency following optimization of identified key PVG parameters, notably, irradiation time, pH of the reaction medium, and the presence of metal sensitizers. For routine use and analytical application, PVG conditions comprising 4 M formic acid as the reaction medium, the presence of 10 mg L-1 Co2+ and 25 mg L-1 Cd2+ as added sensitizers, and an irradiation time of 29 s were chosen. An almost 90% overall PVG efficiency for both Ir3+ and Ir4+ oxidation states was accompanied by excellent repeatability of 1.0% (n = 15) of the peak area response from a 50 ng L-1 Ir standard. Limits of detection ranged from 3 to 6 pg L-1 (1.5-3 fg absolute), dependent on use of the ICPMS reaction/collision cell. Interferences from several transition metals and metalloids as well as inorganic acids and their anions were investigated, and outstanding tolerance toward chloride was found. Accuracy of the developed methodology was verified by analysis of NIST SRM 2556 (Used Auto Catalyst) following peroxide fusion for sample preparation. Practical application was further demonstrated by the direct analysis of spring water, river water, lake water, and two seawater samples with around 100% spike recovery and no sample preparation except the addition of formic acid and the sensitizers.
- 10 February 2023
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 95 (7) , 3694-3702
Open AccessHighly Efficient Photochemical Vapor Generation for Sensitive Determination of Iridium by Inductively Coupled Plasma Mass Spectrometry
Herein, we describe the highly efficient photochemical vapor generation (PVG) of a volatile species of Ir (presumably iridium tetracarbonyl hydride) for subsequent detection by inductively coupled plasma mass spectrometry (ICPMS). A thin-film flow-through photoreactor, operated in flow injection mode, provided high efficiency following optimization of identified key PVG parameters, notably, irradiation time, pH of the reaction medium, and the presence of metal sensitizers. For routine use and analytical application, PVG conditions comprising 4 M formic acid as the reaction medium, the presence of 10 mg L-1 Co2+ and 25 mg L-1 Cd2+ as added sensitizers, and an irradiation time of 29 s were chosen. An almost 90% overall PVG efficiency for both Ir3+ and Ir4+ oxidation states was accompanied by excellent repeatability of 1.0% (n = 15) of the peak area response from a 50 ng L-1 Ir standard. Limits of detection ranged from 3 to 6 pg L-1 (1.5-3 fg absolute), dependent on use of the ICPMS reaction/collision cell. Interferences from several transition metals and metalloids as well as inorganic acids and their anions were investigated, and outstanding tolerance toward chloride was found. Accuracy of the developed methodology was verified by analysis of NIST SRM 2556 (Used Auto Catalyst) following peroxide fusion for sample preparation. Practical application was further demonstrated by the direct analysis of spring water, river water, lake water, and two seawater samples with around 100% spike recovery and no sample preparation except the addition of formic acid and the sensitizers.