Jaromír Vyhnanovský
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jaromír Vyhnanovský has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Stanislav Musil
Institute of Analytical Chemistry of the Czech Academy of Sciences, Veveri 97, Brno 602 00, Czech Republic
6 shared publications - Ralph Edward Sturgeon
National Research Council Canada, Metrology Research Centre, Ottawa, ON, K1A 0R6, Canada
4 shared publications Ralph E. Sturgeon
National Research Council of Canada , 1200 Montreal Road, Ottawa , Ontario K1A 0R6 , Canada
2 shared publications- Enea Pagliano
Metrology Research Center, National Research Council Canada, 1200 Montreal Road, Ottawa, Ontario, K1A 0R6, Canada
1 shared publication Eva Jeníková
Institute of Analytical Chemistry of the Czech Academy of Sciences, Veveri 97, Brno 602 00, Czech Republic
1 shared publication- Eva Jeníková
Institute of Analytical Chemistry of the Czech Academy of Sciences, Veveří 97, 602 00 Brno, Czech Republic
1 shared publication
Latest Publications
- Open Access
- 6 January 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (3) , 1241-1250
Efficient Photochemical Vapor Generation from Low Concentration Formic Acid Media
Herein, we report on surprisingly efficient photochemical vapor generation (PVG) of Ru, Re, and especially Ir, achieved from very dilute HCOOH media employing a thin-film flow-through photoreactor operated in flow injection mode. In the absence of added metal ion sensitizers, efficiencies near 20% for Ir and approximately 0.06% for Ru and Re occur in a narrow range of HCOOH concentrations (around 0.01 M), significantly higher than previously reported from conventionally optimized HCOOH concentrations (1-20 M). A substantial enhancement in efficiency, to around 9 and 1.5%, could be realized for Ru and Re, respectively, when 0.005 M HCOONa served as the PVG medium. The addition of metal ion sensitizers (particularly Cd2+ and Co2+) to 0.01 M HCOOH significantly enhanced PVG efficiencies to 17, 2.2, and 81% for Ru, Re, and Ir, respectively. Possible mechanistic aspects occurring in dilute HCOOH media are discussed, wherein this phenomenon is attributed to the action of 185 nm radiation available in the thin-film flow-through photoreactor. An extended study of PVG of Fe, Co, Ni, As, Se, Mo, Rh, Te, W, and Bi from both dilute HCOOH and CH3COOH was undertaken, and several elements for which a similar phenomenon appears were identified (i.e., Co, As, Se, Te, and Bi). Although use of dilute HCOOH media is attractive for practical analytical applications employing PVG, it is less tolerant toward dissolved gases and interferents in the liquid phase due to the likely lower concentrations of free radicals and aquated electrons required for analyte ion reduction and product synthesis.
- 6 January 2024
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 96 (3) , 1241-1250
Open AccessEfficient Photochemical Vapor Generation from Low Concentration Formic Acid Media
Herein, we report on surprisingly efficient photochemical vapor generation (PVG) of Ru, Re, and especially Ir, achieved from very dilute HCOOH media employing a thin-film flow-through photoreactor operated in flow injection mode. In the absence of added metal ion sensitizers, efficiencies near 20% for Ir and approximately 0.06% for Ru and Re occur in a narrow range of HCOOH concentrations (around 0.01 M), significantly higher than previously reported from conventionally optimized HCOOH concentrations (1-20 M). A substantial enhancement in efficiency, to around 9 and 1.5%, could be realized for Ru and Re, respectively, when 0.005 M HCOONa served as the PVG medium. The addition of metal ion sensitizers (particularly Cd2+ and Co2+) to 0.01 M HCOOH significantly enhanced PVG efficiencies to 17, 2.2, and 81% for Ru, Re, and Ir, respectively. Possible mechanistic aspects occurring in dilute HCOOH media are discussed, wherein this phenomenon is attributed to the action of 185 nm radiation available in the thin-film flow-through photoreactor. An extended study of PVG of Fe, Co, Ni, As, Se, Mo, Rh, Te, W, and Bi from both dilute HCOOH and CH3COOH was undertaken, and several elements for which a similar phenomenon appears were identified (i.e., Co, As, Se, Te, and Bi). Although use of dilute HCOOH media is attractive for practical analytical applications employing PVG, it is less tolerant toward dissolved gases and interferents in the liquid phase due to the likely lower concentrations of free radicals and aquated electrons required for analyte ion reduction and product synthesis.
- Open Access
- 10 February 2023
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 95 (7) , 3694-3702
Highly Efficient Photochemical Vapor Generation for Sensitive Determination of Iridium by Inductively Coupled Plasma Mass Spectrometry
Herein, we describe the highly efficient photochemical vapor generation (PVG) of a volatile species of Ir (presumably iridium tetracarbonyl hydride) for subsequent detection by inductively coupled plasma mass spectrometry (ICPMS). A thin-film flow-through photoreactor, operated in flow injection mode, provided high efficiency following optimization of identified key PVG parameters, notably, irradiation time, pH of the reaction medium, and the presence of metal sensitizers. For routine use and analytical application, PVG conditions comprising 4 M formic acid as the reaction medium, the presence of 10 mg L-1 Co2+ and 25 mg L-1 Cd2+ as added sensitizers, and an irradiation time of 29 s were chosen. An almost 90% overall PVG efficiency for both Ir3+ and Ir4+ oxidation states was accompanied by excellent repeatability of 1.0% (n = 15) of the peak area response from a 50 ng L-1 Ir standard. Limits of detection ranged from 3 to 6 pg L-1 (1.5-3 fg absolute), dependent on use of the ICPMS reaction/collision cell. Interferences from several transition metals and metalloids as well as inorganic acids and their anions were investigated, and outstanding tolerance toward chloride was found. Accuracy of the developed methodology was verified by analysis of NIST SRM 2556 (Used Auto Catalyst) following peroxide fusion for sample preparation. Practical application was further demonstrated by the direct analysis of spring water, river water, lake water, and two seawater samples with around 100% spike recovery and no sample preparation except the addition of formic acid and the sensitizers.
- 10 February 2023
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 95 (7) , 3694-3702
Open AccessHighly Efficient Photochemical Vapor Generation for Sensitive Determination of Iridium by Inductively Coupled Plasma Mass Spectrometry
Herein, we describe the highly efficient photochemical vapor generation (PVG) of a volatile species of Ir (presumably iridium tetracarbonyl hydride) for subsequent detection by inductively coupled plasma mass spectrometry (ICPMS). A thin-film flow-through photoreactor, operated in flow injection mode, provided high efficiency following optimization of identified key PVG parameters, notably, irradiation time, pH of the reaction medium, and the presence of metal sensitizers. For routine use and analytical application, PVG conditions comprising 4 M formic acid as the reaction medium, the presence of 10 mg L-1 Co2+ and 25 mg L-1 Cd2+ as added sensitizers, and an irradiation time of 29 s were chosen. An almost 90% overall PVG efficiency for both Ir3+ and Ir4+ oxidation states was accompanied by excellent repeatability of 1.0% (n = 15) of the peak area response from a 50 ng L-1 Ir standard. Limits of detection ranged from 3 to 6 pg L-1 (1.5-3 fg absolute), dependent on use of the ICPMS reaction/collision cell. Interferences from several transition metals and metalloids as well as inorganic acids and their anions were investigated, and outstanding tolerance toward chloride was found. Accuracy of the developed methodology was verified by analysis of NIST SRM 2556 (Used Auto Catalyst) following peroxide fusion for sample preparation. Practical application was further demonstrated by the direct analysis of spring water, river water, lake water, and two seawater samples with around 100% spike recovery and no sample preparation except the addition of formic acid and the sensitizers.
- 18 February 2022
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 37 (3) , 528-534
GC-MS exploration of photochemically generated species of Os, W and Ru from reductive and oxidative media
GC-MS identification of W(CO) 6 and OsO 4 confirms these products of photochemical vapor generation from W( vi ) and Os( iv ) in reductive and oxidative media, respectively.
- 18 February 2022
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 37 (3) , 528-534
GC-MS exploration of photochemically generated species of Os, W and Ru from reductive and oxidative media
GC-MS identification of W(CO) 6 and OsO 4 confirms these products of photochemical vapor generation from W( vi ) and Os( iv ) in reductive and oxidative media, respectively.
- 30 November 2021
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 93 (49) , 16543-16551
Ultrasensitive Detection of Ruthenium by Coupling Cobalt and Cadmium Ion-Assisted Photochemical Vapor Generation to Inductively Coupled Plasma Mass Spectrometry
An extremely sensitive methodology for the determination of Ru was developed by coupling photochemical vapor generation (PVG) analyte introduction with inductively coupled plasma mass spectrometry (ICPMS). PVG was undertaken with a thin-film flow-through photoreactor in a medium comprising 8 M formic acid in the presence of 10 mg L–1 Co2+ and 25 mg L–1 Cd2+. The volatile product (presumably ruthenium pentacarbonyl) was generated in a flow injection mode, yielding an overall efficiency of 29% at a sample flow rate of 1.4 mL min–1. The presence of both Co2+ and Cd2+ sensitizers enhanced PVG efficiency by 3,200-fold, permitting a 31 s irradiation time. Although enhanced efficiency (≈40%) could be obtained with increased Co2+ concentration, this was not suitable for routine use due to co-generation of cobalt carbonyl. Excellent repeatability (–1 Ru3+. Limits of detection ranged from 20 to 42 pg L–1 (10–21 fg absolute) depending on the measured isotope and operational mode of the ICPMS reaction/collision cell. Interferences from inorganic acids and their anions, several transition metals, and metalloids were investigated. Practical application of the methodology was demonstrated by the analysis of seven water samples of various matrix complexities (well water, spring water, contaminated water, and seawater).
- 30 November 2021
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 93 (49) , 16543-16551
Ultrasensitive Detection of Ruthenium by Coupling Cobalt and Cadmium Ion-Assisted Photochemical Vapor Generation to Inductively Coupled Plasma Mass Spectrometry
An extremely sensitive methodology for the determination of Ru was developed by coupling photochemical vapor generation (PVG) analyte introduction with inductively coupled plasma mass spectrometry (ICPMS). PVG was undertaken with a thin-film flow-through photoreactor in a medium comprising 8 M formic acid in the presence of 10 mg L–1 Co2+ and 25 mg L–1 Cd2+. The volatile product (presumably ruthenium pentacarbonyl) was generated in a flow injection mode, yielding an overall efficiency of 29% at a sample flow rate of 1.4 mL min–1. The presence of both Co2+ and Cd2+ sensitizers enhanced PVG efficiency by 3,200-fold, permitting a 31 s irradiation time. Although enhanced efficiency (≈40%) could be obtained with increased Co2+ concentration, this was not suitable for routine use due to co-generation of cobalt carbonyl. Excellent repeatability (–1 Ru3+. Limits of detection ranged from 20 to 42 pg L–1 (10–21 fg absolute) depending on the measured isotope and operational mode of the ICPMS reaction/collision cell. Interferences from inorganic acids and their anions, several transition metals, and metalloids were investigated. Practical application of the methodology was demonstrated by the analysis of seven water samples of various matrix complexities (well water, spring water, contaminated water, and seawater).
- 20 September 2019
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 91 (20) , 13306-13312
Cadmium Assisted Photochemical Vapor Generation of Tungsten for Detection by Inductively Coupled Plasma Mass Spectrometry
Efficient photochemical vapor generation (PVG) of tungsten has been achieved for the first time using a 19W thin film flow-through photoreactor. The volatile product (most probably tungsten hexacarbonyl) was generated using a flow injection mode and 40% (v/v) formic acid as the reaction medium. An inductively coupled plasma mass spectrometer was utilized for ultrasensitive detection. The addition of Cd2+ as sensitizer was critical, enhancing the overall PVG efficiency some 30,000-fold. At an optimal irradiation time of 19 s, a 6.1-fold enhancement factor and an overall PVG efficiency of 43% were determined from a comparison of response to direct solution nebulization when using a sample flow rate of 2 mL min–1 and 500 mg L–1 Cd2+ as sensitizer. A limit of detection of 0.9 ng L–1 and repeatability (RSD) of 2% at 100 ng L–1 were achieved. Interferences from inorganic acids (HNO3, HCl, H2SO4 and HF) were investigated with respect to analytical application to real samples. The accuracy and practical feasibility of this ultrasensitive methodology was successfully verified by analysis of Certified Reference Material CTA-FFA-1 (Fine Fly Ash) and six natural water samples with low W concentrations.
- 20 September 2019
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 91 (20) , 13306-13312
Cadmium Assisted Photochemical Vapor Generation of Tungsten for Detection by Inductively Coupled Plasma Mass Spectrometry
Efficient photochemical vapor generation (PVG) of tungsten has been achieved for the first time using a 19W thin film flow-through photoreactor. The volatile product (most probably tungsten hexacarbonyl) was generated using a flow injection mode and 40% (v/v) formic acid as the reaction medium. An inductively coupled plasma mass spectrometer was utilized for ultrasensitive detection. The addition of Cd2+ as sensitizer was critical, enhancing the overall PVG efficiency some 30,000-fold. At an optimal irradiation time of 19 s, a 6.1-fold enhancement factor and an overall PVG efficiency of 43% were determined from a comparison of response to direct solution nebulization when using a sample flow rate of 2 mL min–1 and 500 mg L–1 Cd2+ as sensitizer. A limit of detection of 0.9 ng L–1 and repeatability (RSD) of 2% at 100 ng L–1 were achieved. Interferences from inorganic acids (HNO3, HCl, H2SO4 and HF) were investigated with respect to analytical application to real samples. The accuracy and practical feasibility of this ultrasensitive methodology was successfully verified by analysis of Certified Reference Material CTA-FFA-1 (Fine Fly Ash) and six natural water samples with low W concentrations.