Sergey Y. Tetin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sergey Y. Tetin has a total of 55 co-authors. Here are the top co-authors by number of shared publications:
Qiaoqiao Ruan
Applied Research and Technology, Abbott Diagnostics Division, Abbott Laboratories, Abbott Park, IL, 60064, USA
17 shared publicationsJoseph P. Skinner
Diagnostics Research, Abbott Diagnostics Division, Abbott Laboratories, Abbott Park, Illinois, 60064
8 shared publicationsKerry M. Swift
Applied Research and Technology, Abbott Diagnostics Division, Abbott Laboratories, AP-20, 100 Abbott Park Road, Abbott Park, IL 60064-6016, United States
8 shared publicationsPatrick J. Macdonald
Applied Research and Technology, Abbott Diagnostics Division, Abbott Laboratories, AP-20, 100 Abbott Park Road, Abbott Park, IL 60064-6016, United States
6 shared publicationsSylvia C. Saldana
Diagnostics Research, Diagnostics Division, Abbott, Abbott Park, IL 60064
5 shared publications- Qiaoqiao Ruan
Core Diagnostics R&D, Abbott, 100 Abbott Park Road, Abbott Park, IL 60064-6016
3 shared publications
Latest Publications
- 18 October 2022
- Published by Elsevier in Analytical Biochemistry
- Vol. 659, 114955
Epifluorescent single-molecule counting with Streptavidin-Phycoerythrin conjugates
- 18 October 2022
- Published by Elsevier in Analytical Biochemistry
- Vol. 659, 114955
Epifluorescent single-molecule counting with Streptavidin-Phycoerythrin conjugates
- Open Access
- 25 August 2022
- Published by Springer Nature in Communications Medicine
- Vol. 2 (1) , 1-7
Affinity of anti-spike antibodies to three major SARS-CoV-2 variants in recipients of three major vaccines
Background: Measuring anti-viral antibody affinity in blood plasma or serum is a rational quantitative approach to assess humoral immune response and acquired protection. Three common vaccines against SARS-CoV-2—Comirnaty developed by Pfizer/BioNTech, Spikevax developed by Moderna/NIAID, and Jcovden (previously Janssen COVID-19 Vaccine) developed by Johnson & Johnson/Janssen (J&J)—induce antibodies to a variety of immunogenic epitopes including the epitopes located in the ACE2 receptor-binding domain (RBD) of the spike protein. Blocking RBD with antibodies interferes with the binding of the virus to ACE2 thus protecting against infection. Methods: We perform measurements in the serum of the recipients of Pfizer, Moderna, and J&J vaccines, and we compare the apparent affinities of vaccine-induced antibodies against the RBD of the ancestral SARS-CoV-2 virus and the Delta and Omicron variants. We use our recently published method to determine the apparent affinity of anti-spike protein antibodies directly in human serum. This involves probing antibody-antigen equilibria with a small number of antigen-coated magnetic microparticles and imaging them on a fluorescence microscope. Results: Recipients of two-dose Pfizer and Moderna vaccines, as well as recipients of the single-dose J&J vaccine, develop high-affinity antibodies toward RBD derived from ancestral SARS-CoV-2. Affinities of these antibodies to Delta-RBD are approximately 10 times weaker, and even more drastically reduced (∼1000-fold) toward Omicron-RBD. Conclusions: Vaccine-induced antibodies against ancestral SARS-CoV-2 RBD demonstrate ~10-fold and ~1000-fold weaker affinities toward Delta- and Omicron-RBD, respectively. Our approach offers a direct means for evaluating vaccine-induced adaptive immunity and can be helpful in designing or updating vaccines.
- 25 August 2022
- Published by Springer Nature in Communications Medicine
- Vol. 2 (1) , 1-7
Open AccessAffinity of anti-spike antibodies to three major SARS-CoV-2 variants in recipients of three major vaccines
Background: Measuring anti-viral antibody affinity in blood plasma or serum is a rational quantitative approach to assess humoral immune response and acquired protection. Three common vaccines against SARS-CoV-2—Comirnaty developed by Pfizer/BioNTech, Spikevax developed by Moderna/NIAID, and Jcovden (previously Janssen COVID-19 Vaccine) developed by Johnson & Johnson/Janssen (J&J)—induce antibodies to a variety of immunogenic epitopes including the epitopes located in the ACE2 receptor-binding domain (RBD) of the spike protein. Blocking RBD with antibodies interferes with the binding of the virus to ACE2 thus protecting against infection. Methods: We perform measurements in the serum of the recipients of Pfizer, Moderna, and J&J vaccines, and we compare the apparent affinities of vaccine-induced antibodies against the RBD of the ancestral SARS-CoV-2 virus and the Delta and Omicron variants. We use our recently published method to determine the apparent affinity of anti-spike protein antibodies directly in human serum. This involves probing antibody-antigen equilibria with a small number of antigen-coated magnetic microparticles and imaging them on a fluorescence microscope. Results: Recipients of two-dose Pfizer and Moderna vaccines, as well as recipients of the single-dose J&J vaccine, develop high-affinity antibodies toward RBD derived from ancestral SARS-CoV-2. Affinities of these antibodies to Delta-RBD are approximately 10 times weaker, and even more drastically reduced (∼1000-fold) toward Omicron-RBD. Conclusions: Vaccine-induced antibodies against ancestral SARS-CoV-2 RBD demonstrate ~10-fold and ~1000-fold weaker affinities toward Delta- and Omicron-RBD, respectively. Our approach offers a direct means for evaluating vaccine-induced adaptive immunity and can be helpful in designing or updating vaccines.
- Open Access
- 29 December 2021
- Published by Elsevier in EBioMedicine
- Vol. 75, 103796
Affinity of anti-spike antibodies in SARS-CoV-2 patient plasma and its effect on COVID-19 antibody assays
- 29 December 2021
- Published by Elsevier in EBioMedicine
- Vol. 75, 103796
Open AccessAffinity of anti-spike antibodies in SARS-CoV-2 patient plasma and its effect on COVID-19 antibody assays
- 31 March 2021
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 118 (14)
Direct single-molecule imaging for diagnostic and blood screening assays
Every year, over 100 million units of donated blood undergo mandatory screening for HIV, hepatitis B, hepatitis C, and syphilis worldwide. Often, donated blood is also screened for human T cell leukemia–lymphoma virus, Chagas, dengue, Babesia, cytomegalovirus, malaria, and other infections. Several billion diagnostic tests are performed annually around the world to measure more than 400 biomarkers for cardiac, cancer, infectious, and other diseases. Considering such volumes, every improvement in assay performance and/or throughput has a major impact. Here, we show that medically relevant assay sensitivities and specificities can be fundamentally improved by direct single-molecule imaging using regular epifluorescence microscopes. In current microparticle-based assays, an ensemble of bound signal-generating molecules is measured as a whole. By contrast, we acquire intensity profiles to identify and then count individual fluorescent complexes bound to targets on antibody-coated microparticles. This increases the signal-to-noise ratio and provides better discrimination over nonspecific effects. It brings the detection sensitivity down to the attomolar (10−18 M) for model assay systems and to the low femtomolar (10−16 M) for measuring analyte in human plasma. Transitioning from counting single-molecule peaks to averaging pixel intensities at higher analyte concentrations enables a continuous linear response from 10−18 to 10−5 M. Additionally, our assays are insensitive to microparticle number and volume variations during the binding reaction, eliminating the main source of uncertainties in standard assays. Altogether, these features allow for increased assay sensitivity, wide linear detection ranges, shorter incubation times, simpler assay protocols, and minimal reagent consumption. Significance Direct imaging and counting single molecules captured on magnetic microparticles enables diagnostic assays with ultrahigh sensitivities and wide linear detection ranges. The method offers simple assay protocols, short incubation times, minimal reagent consumption, and does not require enzymatic signal amplification. The ratiometric readout, linking the signal and binding area, eliminates the need for strict control over the number of microparticles. Direct imaging provides the sensitivity, flexibility, and simplicity required by rigorous clinical standards. Other benefits of the technique include a seamless transition between digital and analog data analysis modes, scalability, basic consumables, and the reliability to achieve robust implementation in high-throughput automated instruments. HDIA is a versatile tool that can easily be adopted for all receptor–ligand binding assays.
- 31 March 2021
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 118 (14)
Direct single-molecule imaging for diagnostic and blood screening assays
Every year, over 100 million units of donated blood undergo mandatory screening for HIV, hepatitis B, hepatitis C, and syphilis worldwide. Often, donated blood is also screened for human T cell leukemia–lymphoma virus, Chagas, dengue, Babesia, cytomegalovirus, malaria, and other infections. Several billion diagnostic tests are performed annually around the world to measure more than 400 biomarkers for cardiac, cancer, infectious, and other diseases. Considering such volumes, every improvement in assay performance and/or throughput has a major impact. Here, we show that medically relevant assay sensitivities and specificities can be fundamentally improved by direct single-molecule imaging using regular epifluorescence microscopes. In current microparticle-based assays, an ensemble of bound signal-generating molecules is measured as a whole. By contrast, we acquire intensity profiles to identify and then count individual fluorescent complexes bound to targets on antibody-coated microparticles. This increases the signal-to-noise ratio and provides better discrimination over nonspecific effects. It brings the detection sensitivity down to the attomolar (10−18 M) for model assay systems and to the low femtomolar (10−16 M) for measuring analyte in human plasma. Transitioning from counting single-molecule peaks to averaging pixel intensities at higher analyte concentrations enables a continuous linear response from 10−18 to 10−5 M. Additionally, our assays are insensitive to microparticle number and volume variations during the binding reaction, eliminating the main source of uncertainties in standard assays. Altogether, these features allow for increased assay sensitivity, wide linear detection ranges, shorter incubation times, simpler assay protocols, and minimal reagent consumption. Significance Direct imaging and counting single molecules captured on magnetic microparticles enables diagnostic assays with ultrahigh sensitivities and wide linear detection ranges. The method offers simple assay protocols, short incubation times, minimal reagent consumption, and does not require enzymatic signal amplification. The ratiometric readout, linking the signal and binding area, eliminates the need for strict control over the number of microparticles. Direct imaging provides the sensitivity, flexibility, and simplicity required by rigorous clinical standards. Other benefits of the technique include a seamless transition between digital and analog data analysis modes, scalability, basic consumables, and the reliability to achieve robust implementation in high-throughput automated instruments. HDIA is a versatile tool that can easily be adopted for all receptor–ligand binding assays.
- 24 March 2021
- Published by IOP Publishing in Methods and Applications in Fluorescence
- Vol. 9 (2) , 025006
Acridone and acridinium constructs with red-shifted emission
Acridinium 9-carboxylic acid derivatives have been extensively used as chemiluminescent labels in diagnostic assays. Triggering acridinium with basic hydrogen peroxide produces a highly strained dioxetanone intermediate, which converts into an acridone in an electronically excited state and emits light at 420–440 nm. Here, we introduce a novel acridinium-fluorescein construct emitting at 530 nm, in which fluorescein is covalently attached to the acridinium N-10 nitrogen via a propyl sulfonamide linker. To characterize the spectral properties of the acridinium-fluorescein chemiluminophores, we synthesized the analogous acridone-fluorescein constructs. Both acridinium and acridone were linked to either 5- or 6-carboxyfluorescein and independently synthesized as individual structural isomers. Using fluorescent acridone -fluorophore tandems, we investigated and optimized the diluent composition to prevent dye aggregation. As monomolecular species, the acridone isomers demonstrated similar absorption, excitation, and emission spectra, as well as the expected fluorescence lifetimes and molecular brightness. Chemical triggering of acridinium-fluorescein tandems, as well as direct excitation of their acridone-fluorescein analogs, resulted in a nearly complete energy transfer from acridone to fluorescein. Acridone-based dyes can be studied with steady-state spectroscopy. Thus, they will serve as useful tools for structure and solvent optimizations, as well as for studying chemiluminescent energy transfer mechanisms in related acridinium-fluorophore tandems. Direct investigations of the light-emitting molecules generated in the acridinium chemiluminescent reaction empower further development of chemiluminescent labels with red-shifted emission. As illustrated by the two-color HIV model immunoassay, such labels can find immediate applications for multicolor detection in clinical diagnostic assays.
- 24 March 2021
- Published by IOP Publishing in Methods and Applications in Fluorescence
- Vol. 9 (2) , 025006
Acridone and acridinium constructs with red-shifted emission
Acridinium 9-carboxylic acid derivatives have been extensively used as chemiluminescent labels in diagnostic assays. Triggering acridinium with basic hydrogen peroxide produces a highly strained dioxetanone intermediate, which converts into an acridone in an electronically excited state and emits light at 420–440 nm. Here, we introduce a novel acridinium-fluorescein construct emitting at 530 nm, in which fluorescein is covalently attached to the acridinium N-10 nitrogen via a propyl sulfonamide linker. To characterize the spectral properties of the acridinium-fluorescein chemiluminophores, we synthesized the analogous acridone-fluorescein constructs. Both acridinium and acridone were linked to either 5- or 6-carboxyfluorescein and independently synthesized as individual structural isomers. Using fluorescent acridone -fluorophore tandems, we investigated and optimized the diluent composition to prevent dye aggregation. As monomolecular species, the acridone isomers demonstrated similar absorption, excitation, and emission spectra, as well as the expected fluorescence lifetimes and molecular brightness. Chemical triggering of acridinium-fluorescein tandems, as well as direct excitation of their acridone-fluorescein analogs, resulted in a nearly complete energy transfer from acridone to fluorescein. Acridone-based dyes can be studied with steady-state spectroscopy. Thus, they will serve as useful tools for structure and solvent optimizations, as well as for studying chemiluminescent energy transfer mechanisms in related acridinium-fluorophore tandems. Direct investigations of the light-emitting molecules generated in the acridinium chemiluminescent reaction empower further development of chemiluminescent labels with red-shifted emission. As illustrated by the two-color HIV model immunoassay, such labels can find immediate applications for multicolor detection in clinical diagnostic assays.
- 26 November 2018
- Published by Elsevier in Analytical Biochemistry
- Vol. 566, 139-145
Direct single-molecule counting for immunoassay applications
- 26 November 2018
- Published by Elsevier in Analytical Biochemistry
- Vol. 566, 139-145
Direct single-molecule counting for immunoassay applications
- 20 July 2018
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 90 (16) , 9695-9699
Characterization of Fluorescently Labeled Protein with Electrospray Ionization-MS and Fluorescence Spectroscopy: How Random is Random Labeling?
Solvent exposed lysine residues are abundantly present in many proteins. Their highly reactive ε-amino groups serve as universal targets for coupling with active esters of various extrinsic labels including a vast arsenal of fluorescent probes. Here, we describe fluorescent properties and preferential localization of two frequently used fluorescent labels, AlexaFluor488 (AF488) and Cy3, on the surface of a small highly soluble serum protein Neutrophil Gelatinase-Associated Lipocalin (NGAL), which serves as a diagnostic marker for acute kidney failure. Using a standard protocol for labeling with either AF488-SDP or AF488-NHS, we achieved >95% labeling efficiency of the protein as determined by UV-VIS absorption and ESI-MS. However, fluorescence intensity of the labeled protein was less than 10% of the expected value. To understand the unusually high quenching of the probe, we identified the sites of AF488 attachments by means of LC-MS/MS combined with trypsin digestion. Surprisingly, we found that the AF488 label is not randomly distributed among all accessible lysines, but predominantly bound to the residues K125, K126 and K135, which are located in the NGAL calyx and are likely quenched by neighboring tryptophans and tyrosines. On the other hand, when NGAL was labeled with Cy3, the probe’s fluorescence was almost fully retained. The LC-MS/MS data indicated that Cy3 was predominately bound to another lysine, K31, on the protein surface. Our findings suggest that a combination of the inherent properties of the label and peculiarities of the protein microenvironment may selectively lead probes to specific lysine residues and thus challenge the common view that protein labeling is a random process.
- 20 July 2018
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 90 (16) , 9695-9699
Characterization of Fluorescently Labeled Protein with Electrospray Ionization-MS and Fluorescence Spectroscopy: How Random is Random Labeling?
Solvent exposed lysine residues are abundantly present in many proteins. Their highly reactive ε-amino groups serve as universal targets for coupling with active esters of various extrinsic labels including a vast arsenal of fluorescent probes. Here, we describe fluorescent properties and preferential localization of two frequently used fluorescent labels, AlexaFluor488 (AF488) and Cy3, on the surface of a small highly soluble serum protein Neutrophil Gelatinase-Associated Lipocalin (NGAL), which serves as a diagnostic marker for acute kidney failure. Using a standard protocol for labeling with either AF488-SDP or AF488-NHS, we achieved >95% labeling efficiency of the protein as determined by UV-VIS absorption and ESI-MS. However, fluorescence intensity of the labeled protein was less than 10% of the expected value. To understand the unusually high quenching of the probe, we identified the sites of AF488 attachments by means of LC-MS/MS combined with trypsin digestion. Surprisingly, we found that the AF488 label is not randomly distributed among all accessible lysines, but predominantly bound to the residues K125, K126 and K135, which are located in the NGAL calyx and are likely quenched by neighboring tryptophans and tyrosines. On the other hand, when NGAL was labeled with Cy3, the probe’s fluorescence was almost fully retained. The LC-MS/MS data indicated that Cy3 was predominately bound to another lysine, K31, on the protein surface. Our findings suggest that a combination of the inherent properties of the label and peculiarities of the protein microenvironment may selectively lead probes to specific lysine residues and thus challenge the common view that protein labeling is a random process.
- 25 June 2018
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 90 (15) , 9165-9173
Rhodamine-Derived Fluorescent Dye with Inherent Blinking Behavior for Super-Resolution Imaging
Super-resolution microscopy enables imaging of structures smaller than the diffraction limit. Single-molecule localization microscopy methods, such as PALM and STORM, reconstruct images by plotting the centroids of fluorescent point sources from a series of frames in which only a few molecules are fluorescing at a time. These approaches require simpler instrumentation than methods that depend on structured illumination, and thus are becoming widespread. The functionalized rhodamine derivative reported in this paper spontaneously converts between a bright and dark state due to pH-dependent cyclization. At pH 7, less than 0.5% of the dye molecules are fluorescent at any given time. Blinking occurs on timescales of seconds to minutes and can therefore be used for single-molecule localization microscopy without sample treatment or activation. The dye is easy to synthesize and functionalize. It is bright and straightforward to use making it suitable for super-resolution imaging.
- 25 June 2018
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 90 (15) , 9165-9173
Rhodamine-Derived Fluorescent Dye with Inherent Blinking Behavior for Super-Resolution Imaging
Super-resolution microscopy enables imaging of structures smaller than the diffraction limit. Single-molecule localization microscopy methods, such as PALM and STORM, reconstruct images by plotting the centroids of fluorescent point sources from a series of frames in which only a few molecules are fluorescing at a time. These approaches require simpler instrumentation than methods that depend on structured illumination, and thus are becoming widespread. The functionalized rhodamine derivative reported in this paper spontaneously converts between a bright and dark state due to pH-dependent cyclization. At pH 7, less than 0.5% of the dye molecules are fluorescent at any given time. Blinking occurs on timescales of seconds to minutes and can therefore be used for single-molecule localization microscopy without sample treatment or activation. The dye is easy to synthesize and functionalize. It is bright and straightforward to use making it suitable for super-resolution imaging.
- 1 August 2017
- Published by Elsevier in Analytical Biochemistry
- Vol. 531, 78-82
The photostability of the commonly used biotin-4-fluorescein probe
- 1 August 2017
- Published by Elsevier in Analytical Biochemistry
- Vol. 531, 78-82
The photostability of the commonly used biotin-4-fluorescein probe
- 1 February 2017
- Published by Elsevier in Biophysical Journal
- Vol. 112 (3) , 150a
Single-Molecule Counting Applied to Immunoassays
- 1 February 2017
- Published by Elsevier in Biophysical Journal
- Vol. 112 (3) , 150a
Single-Molecule Counting Applied to Immunoassays