Qiaoqiao Ruan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Qiaoqiao Ruan has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Sergey Y. Tetin
Applied Research and Technology, Abbott Diagnostics Division, Abbott Laboratories, Abbott Park, IL, 60064, USA
3 shared publications Cheng Zhao
Applied Research and Technology, Core Diagnostics, Abbott Laboratories, 100 Abbott Park Road, Abbott Park, IL, 60064-6016, United States
2 shared publicationsJeffrey M. Schaub
Core Diagnostics R&D, Abbott, 100 Abbott Park Road, Abbott Park, IL 60064-6016
2 shared publications- Patrick J. Macdonald
Applied Research and Technology, Abbott Diagnostics Division, Abbott Laboratories, Abbott Park, USA
2 shared publications Quinn A. Best
Core Diagnostics R&D, Abbott, 100 Abbott Park Road, Abbott Park, IL 60064-6016
2 shared publications- Carroll L. Williams
Applied Research and Technology, Abbott Diagnostics Division, Abbott Laboratories, Abbott Park, USA
1 shared publication
Latest Publications
- 30 June 2026
- Published by Elsevier in Analytical Biochemistry
- Vol. 717, 116188
Evaluation of a method for affinity measurement using solution equilibrium titration with magnetic beads
- 30 June 2026
- Published by Elsevier in Analytical Biochemistry
- Vol. 717, 116188
Evaluation of a method for affinity measurement using solution equilibrium titration with magnetic beads
- Open Access
- 8 March 2025
- Published by Elsevier in Biochemistry and Biophysics Reports
- Vol. 42, 101971
Three sample-sparing techniques to estimate the molar absorption coefficient of luminescent dyes
- 8 March 2025
- Published by Elsevier in Biochemistry and Biophysics Reports
- Vol. 42, 101971
Open AccessThree sample-sparing techniques to estimate the molar absorption coefficient of luminescent dyes
- Open Access
- 2 June 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-9
A method for parallel microscale protein labeling and precise control over the average degree of labeling (aDoL)
A widely used approach for protein conjugation is through the lysine residues reacting with NHS- or other active esters. However, it is a challenge to precisely control the degree of labeling (DoL) due to the instability of active ester and variability of reaction efficiencies. Here, we provide a protocol for better control of aDoL using existing Copper-free Click Chemistry reagents. It is a two-step reaction with one purification in between. Briefly, proteins of interest were first activated with azide-NHS. After removing unreacted azide-NHS, the protein-N3 is then reacted with a limited amount of complementary click tag. Our studies have shown the click tag will fully react with the protein-N3 after 24 h’ incubation, and therefore does not require additional purification steps. As such, the aDoL is equal to the input molar ratio of the click tag and the protein. Furthermore, this approach offers a much simpler and more economical way to perform parallel microscale labeling. Once a protein is pre-activated with N3-NHS, any fluorophore or molecule with the complementary click tag can be attached to the protein by mixing the two ingredients. Quantities of the protein used in the click reaction can be at any desired amount. In one example, we labeled an antibody in parallel with 9 different fluorophores using a total of 0.5 mg of antibody. In another example, we labeled Ab with targeted aDoL value from 2 to 8. In a stability comparison study, we have found the conjugated fluorophore using the suggested click protocol stayed attached to the protein longer than with standard NHS-fluorophore labeling.
- 2 June 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-9
Open AccessA method for parallel microscale protein labeling and precise control over the average degree of labeling (aDoL)
A widely used approach for protein conjugation is through the lysine residues reacting with NHS- or other active esters. However, it is a challenge to precisely control the degree of labeling (DoL) due to the instability of active ester and variability of reaction efficiencies. Here, we provide a protocol for better control of aDoL using existing Copper-free Click Chemistry reagents. It is a two-step reaction with one purification in between. Briefly, proteins of interest were first activated with azide-NHS. After removing unreacted azide-NHS, the protein-N3 is then reacted with a limited amount of complementary click tag. Our studies have shown the click tag will fully react with the protein-N3 after 24 h’ incubation, and therefore does not require additional purification steps. As such, the aDoL is equal to the input molar ratio of the click tag and the protein. Furthermore, this approach offers a much simpler and more economical way to perform parallel microscale labeling. Once a protein is pre-activated with N3-NHS, any fluorophore or molecule with the complementary click tag can be attached to the protein by mixing the two ingredients. Quantities of the protein used in the click reaction can be at any desired amount. In one example, we labeled an antibody in parallel with 9 different fluorophores using a total of 0.5 mg of antibody. In another example, we labeled Ab with targeted aDoL value from 2 to 8. In a stability comparison study, we have found the conjugated fluorophore using the suggested click protocol stayed attached to the protein longer than with standard NHS-fluorophore labeling.
- Open Access
- 25 August 2022
- Published by Springer Nature in Communications Medicine
- Vol. 2 (1) , 1-7
Affinity of anti-spike antibodies to three major SARS-CoV-2 variants in recipients of three major vaccines
Background: Measuring anti-viral antibody affinity in blood plasma or serum is a rational quantitative approach to assess humoral immune response and acquired protection. Three common vaccines against SARS-CoV-2—Comirnaty developed by Pfizer/BioNTech, Spikevax developed by Moderna/NIAID, and Jcovden (previously Janssen COVID-19 Vaccine) developed by Johnson & Johnson/Janssen (J&J)—induce antibodies to a variety of immunogenic epitopes including the epitopes located in the ACE2 receptor-binding domain (RBD) of the spike protein. Blocking RBD with antibodies interferes with the binding of the virus to ACE2 thus protecting against infection. Methods: We perform measurements in the serum of the recipients of Pfizer, Moderna, and J&J vaccines, and we compare the apparent affinities of vaccine-induced antibodies against the RBD of the ancestral SARS-CoV-2 virus and the Delta and Omicron variants. We use our recently published method to determine the apparent affinity of anti-spike protein antibodies directly in human serum. This involves probing antibody-antigen equilibria with a small number of antigen-coated magnetic microparticles and imaging them on a fluorescence microscope. Results: Recipients of two-dose Pfizer and Moderna vaccines, as well as recipients of the single-dose J&J vaccine, develop high-affinity antibodies toward RBD derived from ancestral SARS-CoV-2. Affinities of these antibodies to Delta-RBD are approximately 10 times weaker, and even more drastically reduced (∼1000-fold) toward Omicron-RBD. Conclusions: Vaccine-induced antibodies against ancestral SARS-CoV-2 RBD demonstrate ~10-fold and ~1000-fold weaker affinities toward Delta- and Omicron-RBD, respectively. Our approach offers a direct means for evaluating vaccine-induced adaptive immunity and can be helpful in designing or updating vaccines.
- 25 August 2022
- Published by Springer Nature in Communications Medicine
- Vol. 2 (1) , 1-7
Open AccessAffinity of anti-spike antibodies to three major SARS-CoV-2 variants in recipients of three major vaccines
Background: Measuring anti-viral antibody affinity in blood plasma or serum is a rational quantitative approach to assess humoral immune response and acquired protection. Three common vaccines against SARS-CoV-2—Comirnaty developed by Pfizer/BioNTech, Spikevax developed by Moderna/NIAID, and Jcovden (previously Janssen COVID-19 Vaccine) developed by Johnson & Johnson/Janssen (J&J)—induce antibodies to a variety of immunogenic epitopes including the epitopes located in the ACE2 receptor-binding domain (RBD) of the spike protein. Blocking RBD with antibodies interferes with the binding of the virus to ACE2 thus protecting against infection. Methods: We perform measurements in the serum of the recipients of Pfizer, Moderna, and J&J vaccines, and we compare the apparent affinities of vaccine-induced antibodies against the RBD of the ancestral SARS-CoV-2 virus and the Delta and Omicron variants. We use our recently published method to determine the apparent affinity of anti-spike protein antibodies directly in human serum. This involves probing antibody-antigen equilibria with a small number of antigen-coated magnetic microparticles and imaging them on a fluorescence microscope. Results: Recipients of two-dose Pfizer and Moderna vaccines, as well as recipients of the single-dose J&J vaccine, develop high-affinity antibodies toward RBD derived from ancestral SARS-CoV-2. Affinities of these antibodies to Delta-RBD are approximately 10 times weaker, and even more drastically reduced (∼1000-fold) toward Omicron-RBD. Conclusions: Vaccine-induced antibodies against ancestral SARS-CoV-2 RBD demonstrate ~10-fold and ~1000-fold weaker affinities toward Delta- and Omicron-RBD, respectively. Our approach offers a direct means for evaluating vaccine-induced adaptive immunity and can be helpful in designing or updating vaccines.
- 31 March 2021
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 118 (14)
Direct single-molecule imaging for diagnostic and blood screening assays
Every year, over 100 million units of donated blood undergo mandatory screening for HIV, hepatitis B, hepatitis C, and syphilis worldwide. Often, donated blood is also screened for human T cell leukemia–lymphoma virus, Chagas, dengue, Babesia, cytomegalovirus, malaria, and other infections. Several billion diagnostic tests are performed annually around the world to measure more than 400 biomarkers for cardiac, cancer, infectious, and other diseases. Considering such volumes, every improvement in assay performance and/or throughput has a major impact. Here, we show that medically relevant assay sensitivities and specificities can be fundamentally improved by direct single-molecule imaging using regular epifluorescence microscopes. In current microparticle-based assays, an ensemble of bound signal-generating molecules is measured as a whole. By contrast, we acquire intensity profiles to identify and then count individual fluorescent complexes bound to targets on antibody-coated microparticles. This increases the signal-to-noise ratio and provides better discrimination over nonspecific effects. It brings the detection sensitivity down to the attomolar (10−18 M) for model assay systems and to the low femtomolar (10−16 M) for measuring analyte in human plasma. Transitioning from counting single-molecule peaks to averaging pixel intensities at higher analyte concentrations enables a continuous linear response from 10−18 to 10−5 M. Additionally, our assays are insensitive to microparticle number and volume variations during the binding reaction, eliminating the main source of uncertainties in standard assays. Altogether, these features allow for increased assay sensitivity, wide linear detection ranges, shorter incubation times, simpler assay protocols, and minimal reagent consumption. Significance Direct imaging and counting single molecules captured on magnetic microparticles enables diagnostic assays with ultrahigh sensitivities and wide linear detection ranges. The method offers simple assay protocols, short incubation times, minimal reagent consumption, and does not require enzymatic signal amplification. The ratiometric readout, linking the signal and binding area, eliminates the need for strict control over the number of microparticles. Direct imaging provides the sensitivity, flexibility, and simplicity required by rigorous clinical standards. Other benefits of the technique include a seamless transition between digital and analog data analysis modes, scalability, basic consumables, and the reliability to achieve robust implementation in high-throughput automated instruments. HDIA is a versatile tool that can easily be adopted for all receptor–ligand binding assays.
- 31 March 2021
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 118 (14)
Direct single-molecule imaging for diagnostic and blood screening assays
Every year, over 100 million units of donated blood undergo mandatory screening for HIV, hepatitis B, hepatitis C, and syphilis worldwide. Often, donated blood is also screened for human T cell leukemia–lymphoma virus, Chagas, dengue, Babesia, cytomegalovirus, malaria, and other infections. Several billion diagnostic tests are performed annually around the world to measure more than 400 biomarkers for cardiac, cancer, infectious, and other diseases. Considering such volumes, every improvement in assay performance and/or throughput has a major impact. Here, we show that medically relevant assay sensitivities and specificities can be fundamentally improved by direct single-molecule imaging using regular epifluorescence microscopes. In current microparticle-based assays, an ensemble of bound signal-generating molecules is measured as a whole. By contrast, we acquire intensity profiles to identify and then count individual fluorescent complexes bound to targets on antibody-coated microparticles. This increases the signal-to-noise ratio and provides better discrimination over nonspecific effects. It brings the detection sensitivity down to the attomolar (10−18 M) for model assay systems and to the low femtomolar (10−16 M) for measuring analyte in human plasma. Transitioning from counting single-molecule peaks to averaging pixel intensities at higher analyte concentrations enables a continuous linear response from 10−18 to 10−5 M. Additionally, our assays are insensitive to microparticle number and volume variations during the binding reaction, eliminating the main source of uncertainties in standard assays. Altogether, these features allow for increased assay sensitivity, wide linear detection ranges, shorter incubation times, simpler assay protocols, and minimal reagent consumption. Significance Direct imaging and counting single molecules captured on magnetic microparticles enables diagnostic assays with ultrahigh sensitivities and wide linear detection ranges. The method offers simple assay protocols, short incubation times, minimal reagent consumption, and does not require enzymatic signal amplification. The ratiometric readout, linking the signal and binding area, eliminates the need for strict control over the number of microparticles. Direct imaging provides the sensitivity, flexibility, and simplicity required by rigorous clinical standards. Other benefits of the technique include a seamless transition between digital and analog data analysis modes, scalability, basic consumables, and the reliability to achieve robust implementation in high-throughput automated instruments. HDIA is a versatile tool that can easily be adopted for all receptor–ligand binding assays.
- 1 March 2008
- Published by Elsevier in Analytical Biochemistry
- Vol. 374 (1) , 182-195
Applications of dual-color fluorescence cross-correlation spectroscopy in antibody binding studies
- 1 March 2008
- Published by Elsevier in Analytical Biochemistry
- Vol. 374 (1) , 182-195
Applications of dual-color fluorescence cross-correlation spectroscopy in antibody binding studies
- 1 August 2004
- Published by Elsevier in Biophysical Journal
- Vol. 87 (2) , 1260-1267
Spatial-Temporal Studies of Membrane Dynamics: Scanning Fluorescence Correlation Spectroscopy (SFCS)
- 1 August 2004
- Published by Elsevier in Biophysical Journal
- Vol. 87 (2) , 1260-1267
Spatial-Temporal Studies of Membrane Dynamics: Scanning Fluorescence Correlation Spectroscopy (SFCS)