MJMohit Kumar Joshi

Mohit Kumar Joshi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Mohit Kumar Joshi has a total of 29 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Performance evaluation of beam breakup instability analysis of energy recovery linac using physics-inspired neural networks

    by M. K. Joshi, S. P. Sethi, S. Setiniyaz, N. Nuchsirikulaphong, R. Apsimon

    Beam breakup (BBU) instability limits the performance of energy recovery linacs (ERLs). This study presents a new approach to estimating the BBU threshold current using a physics-inspired neural network. The application of neural networks to the highly nonlinear beam dynamics of ERLs opens a new paradigm for the development of efficient future particle accelerators. It is found that figure-of-merit-based data can predict the threshold current with higher accuracy than directly feeding the proposed network with raw parameter-based data. This study investigates how embedding such a physically meaningful feature influences predictive performance and generalization. In this work, the effect of the variation in higher-order modes (HOM) parameters due to the geometrical tolerances in the rf cavity fabrication on the BBU threshold current is analyzed with the proposed multilayered bidirectional long short-term memory (BiLSTM) neural network.

  • Techniques for Monitoring and Fault Diagnostics of Industrial Plasma Processes and Applications

    by Shakti Prasad Sethi, Ajay Pal Singh, Mohit Kumar Joshi

    Plasma science and technology are considered an important source of applications for various industrial processes and scientific research. The scope of plasma sources is applied in various areas of science and engineering disciplines to leverage new applications with better efficiency and productivity. This article presents various techniques developed for monitoring plasma processes and discusses methods applied to diagnosing fault events during operation. It reviews the application of sensors, probes, and invasive as well as noninvasive diagnostic techniques for fault detection and mitigation of challenges in plasma systems. In this article, the role of signal and image processing techniques in fault event diagnosis is highlighted. The study also highlights the application of machine learning (ML) and optimization methods for fault classification and the optimization of plasma processes. Schematics of key experimental setups incorporating various sensing techniques are presented to facilitate better understanding, and the associated application-specific techniques are also explained. This article presents a comprehensive review of implemented techniques for identifying fault events in plasma processes, optimizing overall process efficiency, and enhancing system performance.


  • Ka-Band Meander-Line Slow Wave Structure Design for Traveling Wave Tube for High Data Rate Wireless Links

    by Mohit Kumar Joshi, Vincent Da Costa, Muhammad Zubair, Ahsan Altaf, Rosa Letizia, Claudio Paoloni

    Ka-band (26–40 GHz) is widely used for satellite links. In particular, the 26.5–29.5-GHz band is mostly used for uplink in low-Earth-orbit (LEO) constellations and is also part of the FR2 (24.25–52.6 GHz) for high-capacity terrestrial links. The addition of the 26.5–29.5-GHz band for downlink would increase the satellite throughput, but presently, solid-state power amplifier (SSPA) modules do not provide enough power and have too low efficiency. Ka-band traveling wave tubes (TWTs) are traditionally used in geostationary Earth orbit (GEO) satellites for their high transmission power and high efficiency. Compact and affordable Ka-band TWTs would be a promising solution to provide transmission power to enable downlink at the Ka-band. Meander lines (MLs) have been extensively investigated as slow wave structures (SWSs) for lightweight, small dimensions, and low voltage operation. In this article, an interaction circuit for compact and affordable Ka-band TWTs based on the ML (ML-TWT) is discussed. The first TWT with two ML sections interacting with an elliptical sheet beam with 4.56-kV beam voltage, in the 26.5–29.5-GHz frequency range, is proposed. More than 31-W output power with about 38-dB gain in the linear region is achieved. A single-section ML-SWS and a sever for the two-section ML-TWT are fabricated and measured. The compact dimensions and low voltage of the novel ML-TWT make it a competitive solution for medium transmission power in the future Ka-band high-capacity LEO satellite and terrestrial links for future 5G and 6G network integration.


  • Open Access

    Policy and Regulatory Environment for Utility-Scale Energy Storage: Nepal

    by Amy Rose, Kapil Duwadi, David Palchak, Mohit Joshi

    This report—Policy and Regulatory Environment for Utility-Scale Energy Storage: Nepal—is part of a series investigating the potential for utility-scale energy storage in South Asia. This report is the second in a series of country-specific evaluations of policy and regulatory environments for energy storage in the region. These evaluations apply the previously developed Energy Storage Readiness Assessment to evaluate the policy and regulatory environment for energy storage in Nepal. A similar assessment is already complete for India and a forthcoming report will expand this analysis to Bangladesh. These evaluations are designed to provide insights on the opportunities and barriers for energy storage growth and deployment in each country.

  • Design and Analysis of Width-Modulated Two-Section Sine Waveguide for G-Band Traveling-Wave Tube

    by Narugopal Nayek, Mohit Kumar Joshi, Ramesh Kumar Sonkar, Tapeshwar Tiwari, Ratnajit Bhattacharjee

    A novel width-modulated sine waveguide traveling-wave tube (SWGTWT) is proposed for G-band operation. The broadband single-section and two-section SWGTWT are analyzed, which has the potential to address various technological challenges in the THz regime, such as fabrication difficulty, reflection, and attenuation of RF power. The two-section design has separate RF structures for input and output sections of the TWT, which helps to eliminate undesired reflection during high-power operation. The width modulation is employed to enhance the interaction impedance and also to realize the flat dispersion characteristic of the slow wave structure (SWS). The fabrication feasibility of the structure is demonstrated by fabricating the scaled structure at the Ku-band. A 20.4-kV, 50-mA cylindrical beam is employed in the particle-in-cell (PIC) simulation. The single-section structure offers a maximum power of 53 W with a 5.19% efficiency at 210 GHz. The peak power and a 3-dB bandwidth for the two-section structure are estimated to be 38.9 W and 32.5 GHz, respectively. The structure produces greater than 10 W of output power over a 46-GHz frequency band covering the range of 200-246 GHz.


  • Design and Efficiency Enhancement of a Ka-Band Industrial Gyrotron

    by Narugopal Nayek, Mohit Kumar Joshi, Ramesh Kumar Sonkar, Tapeshwar Tiwari, Ratnajit Bhattacharjee

    The key subsystems of a high efficiency material processing gyrotron are designed at an operating frequency of 27.885 GHz. A triode-type electron gun is designed to launch hollow spiraling electron beam. The outer diameter of the gun is kept at 50 mm to lower inside diameter of the magnet. Start oscillation current for TE₀₂ operating as well as competing modes is plotted. The output power and efficiency are predicted to be 18.4 kW and 46%, respectively, based on single mode time-dependent analytical equation. Beam-wave interaction is studied by employing particle-in-cell (PIC) simulation. Electronic efficiency and output power are increased by operating the tube in hard excitation region. An axially slotted cavity is adopted to abridge mode competitions. The output power and electronic efficiency are obtained to be 20.08 kW and 50.2%, respectively, without considering any velocity spread of the electron beam. However, the efficiency is reduced to 45%, when a moderate transverse velocity spread of 5% is considered. The power efficiency is enhanced to 67.07% by introducing a 3-staged depressed collector.


  • Particle-in-Cell Simulation and Analysis of 28-Vane Megawatt-Class Pulsed Power Coaxial Magnetron in X-Band

    by Mohit Kumar Joshi, Sandeep Kumar Vyas, Tapeshwar Tiwari, Ratnajit Bhattacharjee

    This article presents the design and analysis of a 28-vane megawatt-class pulsed power coaxial magnetron operating in X-band for medical linear accelerator (LINAC) applications. The systematic design procedure of the coaxial magnetron is presented. The proposed coaxial magnetron is analyzed using particle-in-cell (PIC) simulations. The output is taken from the standard WR112 waveguide through a rectangular slot in the outer wall of the coaxial cavity. The maximum total efficiency of 62.04% is obtained at 9.2987 GHz, having a 2.12-MW peak output power for stable π-mode operation. The π-mode operation is determined by 14 spokes of electrons in the PIC simulation. Electronic efficiency and circuit efficiency of the designed coaxial magnetron are obtained as 73.86% and 84%, respectively. The output peak power can be enhanced by optimizing the applied magnetic field in the operating region of π-mode. Total efficiency is improved by 2.74% by changing the shape of the cathode end hats from conventional to conical. The dielectric properties of the slot-mode suppressor are optimized based on the output performance of coaxial magnetron. The optimal values of dielectric constant and loss tangents are obtained as 21 and 0.08, respectively. The frequency-tuning characteristics of the magnetron are also analyzed, and the tuning range is obtained as 9.2987 GHz ± 20 MHz.


  • A New Approach for High-Power Coaxial Magnetron Using Stacked Anode Resonators

    by Mohit Kumar Joshi, Sandeep Kumar Vyas, Tapeshwar Tiwari, Ratnajit Bhattacharjee

    A novel design of the X-band megawatt-class coaxial magnetron using multiple-anode resonators placed in a stacked configuration is presented. The proposed design enhances the output power of a coaxial magnetron substantially without requiring external circuitry for power combining. The coaxial magnetron design is presented with two different cathode arrangements: one with separate cathodes and the other with connected cathodes. This article presents a new way for the generation of high-power microwaves by combining powers generated by multiple-anode resonators within a coaxial magnetron itself. The proposed coaxial magnetron is analyzed using the particle-in-cell (PIC) simulations. The output power of double-anode resonator magnetron is found to increase about 2.73 times compared with the coaxial magnetron with a single-anode resonator. The peak output power of 5.78 MW with 49.4% efficiency is obtained at 9.2906 GHz when a separate cathode arrangement is used, and both cathodes are excited simultaneously. The circuit efficiency and electronic efficiency are obtained as 83% and 59.5%, respectively. A wide frequency tuning range of 30.5 MHz is obtained, from 9.2840 to 9.3145 GHz. When only one cathode is excited, a different power level can be obtained. The output power can be enhanced further if more than two anode resonators are used in the connected cathode arrangement. The peak output power of 7.8 MW with 52% total efficiency is obtained with three anode resonators. The output performances of both the designs having different cathode arrangements are compared.


  • Multiphysics and Multipactor Analyses of TE022-Mode High-Power X-Band RF Window

    by Mohit Kumar Joshi, Narugopal Nayek, Tapeshwar Tiwari, Jan Pidanic, Zdenek Nemec, Ratnajit Bhattacharjee

    This letter presents the design of an overmoded X-band RF window for use in high-power microwave tubes, such as klystron, magnetron, and linear accelerator (LINAC). The cylindrical section of the window containing dielectric barrier operates in the TE₀₂₂ mode. Conversion from TE₁₀ mode to TE₀₂₂ mode is achieved using four rectangular slots made on the narrow walls of the rectangular waveguide sections. The simulation results for the proposed design in CST and HFSS are in good agreement. The return loss, insertion loss, and bandwidth are obtained as 52.76 dB, 0.06 dB, and 41.4 MHz, respectively, at 9.3 GHz. Coupled electromagnetic, thermal, and structural simulations are performed to study the multiphysics performance of the RF window. The multipactor analysis is carried out in SPARK3D to determine the multipactor threshold. The proposed TE₀₂₂ mode RF window can operate safely at a 20.75 MW of peak power.


  • Design and Analysis of Overmoded RF Window for High-Power Applications in $X$ -Band

    by Mohit Kumar Joshi, Narugopal Nayek, Tapeshwar Tiwari, Ratnajit Bhattacharjee

    This article presents the design and analysis of overmoded RF window for megawatt-class pulsed coaxial magnetron operating in X-band and other high-power systems such as linear accelerator (LINAC) and devices such as gyrotron and klystron. Three ingenious designs of RF windows are proposed based on the mode excitation techniques. Design 1 operates in TE₀₁₂-type mode (mixed with TE₁₁₃ and TE₂₁₃), Design 2 in TE₀₁₂-type mode (mixed with TE₃₁₂), and Design 3 in TE₀₁₄-type mode. Mixed-mode operation broadens the bandwidth of the RF window compared to single-mode operation. RF windows are simulated in CST and return losses are obtained as 55.04, 51.52, and 53.92 dB, and insertion losses as 0.054, 0.07, 0.194 dB, respectively. Return losses and insertion losses of the proposed designs are verified in HFSS, and results are in good agreement with the results obtained from CST. Coupled multiphysics analyses are carried out to study thermal and structural behaviors of the proposed RF windows. Sensitivity analysis of the windows is also performed to analyze the effect of mechanical deformation on the performance of S-parameters. Multipactor analysis is carried out to determine the safe operating power level, and multipactor thresholds are obtained as 10, 16, and 2.35 MW, respectively.