YZYuriy Tymofiiovych Zholudov

Yuriy Tymofiiovych Zholudov

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Yuriy Tymofiiovych Zholudov has a total of 77 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Fast counter of pulses for analytical sensor systems

    by S.V. Bakin, D.O. Kolesnykov, Y.T. Zholudov, D.V. Snizhko

    The work considers the device developed to integrate photomultipliers operating in the photon counting mode into a measuring system. The concept of the device construction and its components are considered. Practical solutions are presented for implementing the main functionality of the device, namely, counting pulses without their loss and the absence of "dead" time.

  • Open Access

    INFLUENCE OF THE MEDIUM ON THE ELECTROCHEMILUMINESCENT PROPERTIES OF MODIFIED ELECTRODES

    by D. Yu. Martynov, I. I. Bespalova, E. V. Shlein, M. I. Slipchenko, Yu. T. Zholudov

    This work investigates the specific influence of coreactants and background electrolytes on the electrochemiluminescent (ECL) properties of organic and perovskite luminophores. It is shown that lithium perchlorate (LiClO4), traditionally considered an inert electrolyte, is capable of inducing measurable ECL emission in 9,10-diphenylanthracene/polymethyl methacrylate (DPA/PMMA) films fabricated via the Langmuir–Blodgett technique, even in the absence of classical coreactants. Several hypotheses are proposed to explain this phenomenon, including specific interactions of Li+ cations with the π-system of DPA and the possible stabilization of radical intermediates, highlighting the non-inert role of lithium salts in ECL processes. In parallel, the ECL response of CsPbBr3 perovskite films in the presence of persulfate (S2O82-) as a cathodic coreactant was studied. Two ECL generation processes separated by potential were identified. It was established that the intrinsic ECL of perovskites exceeds the background emission of persulfate, and is characterized by stability and reproducibility over more than 30 electrolysis cycles. Morphological studies revealed surface changes of the films during electrolysis, correlating with the dynamics of the signal. Spectral analysis confirmed the difference between the two processes and revealed partial overlap of the electrolyte emission with the perovskite luminescence, enabling resonance signal enhancement. Furthermore, the influence of oxygen was established, modulating the intensity and stability of ECL. The obtained results demonstrate the critical role of the electrolyte, interfacial processes, and film morphology in the formation of ECL, opening prospects for the development of sensitive and stable luminescent platforms for analytical and biosensing applications.

  • Open Access

    ELECTROCHEMILUMINESCENT SENSORS: MANUFACTURING TECHNOLOGIES AND ANALYTICAL CAPABILITIES. REVIEW

    by D. Yu. Martynov, E. V. Shlein, D. V. Snizhko, Ia. M. Gnilitskyi, I. I. Bespalova, M. I. Slipchenko, Yu. T. Zholudov

    The paper presents a comprehensive review of current research and technological approaches in the development of electrochemiluminescent (ECL) sensors, based on data from the literature and the results of our own research. It analyzes the basic principles of operation of these devices, the design features of electrode systems, methods for modifying their surfaces using nanomaterials and composites, as well as various technologies for applying active layers. The relationship between the structure of the sensor and its analytical efficiency, in particular the increase in sensitivity and selectivity, which is of key importance for use in biomedicine, environmental monitoring, and industrial analytics, is outlined. The article also contains a comparative analysis of modern methods for generating ECL signals and suggests promising areas for further research on the integration of innovative materials and technologies to optimize the performance of sensor systems. The work aims to systematize existing knowledge in the field and identify the main challenges to the expansion of ECL sensor applications.

  • Open Access

    Wireless single-electrode electrochemiluminescence device based on wireless reverse charging or on-the-go USB transmission for multiplex analysis

    by Chengda Meng, Dmytro Viktorovych Snizhko, Yuriy Tymofiiovych Zholudov, Wei Zhang, Yiran Guan, Yu Tian, Guobao Xu

    A wireless electrochemiluminescence device employing the wireless reverse charging function or on-the-go (OTG) USB transmission function of smartphones is developed for wireless multiplex analysis using a smartphone as detector for the first time.


  • Effect of Lithium Ion on Electrochemiluminescent Response of Sensors Based on Langmuir-Blodgett Films with Polycyclic Organic Phosphors

    by Danylo Martynov, Dmytro Snizhko, Mykola Slipchenko, Yuriy Zholudov

    This work reports the results of electrolysis of an aqueous solution containing lithium perchlorate as a supporting electrolyte and tripropylamine (TPrA) electrochemiluminescence (ECL) as a coreactant on ITO electrodes modified with a 9.,10-diphenylanthracene (DPA) phosphor in a polymethylmethacrylate (PMMA) matrix deposited by the Langmuir-Blodgett method. The results show that lithium perchlorate solution gives a background ECL signal in the absence of coreactant, and when TPrA is added, the shape and appearance of the ECL emission change., whereas TPrA/DPA system gives no ECL emission. Changing lithium perchlorate to sodium perchlorate leads to the disappearance of ECL, and purification with an organic solvent of lithium perchlorate does not affect the light emission, indicating the specific behavior of the lithium-ion during electrolysis. Special attention is also paid to the procedure of cleaning ITO substrates before film deposition and after its use with chloroform vapor in a distillation setup.

  • Numerical Simulation of Kinetic Processes in Thin-layer Electrochemiluminescent Light Emitting Cells

    by Danylo Martynov, Yuriy Zholudov, Mykola Slipchenko, Olena Slipchenko, Kyrylo Korobchynskyi

    This study presents a comprehensive mathematical modeling and numerical simulation of electrochemiluminescent (ECL) cells, which are the main elements of ECL sensors and light emitters. The ECL cell is designed to generate optical signal, and its efficiency is crucial for the overall performance of ECL sensors and light emitting devices. The mathematical model is based on the physical principles of electrochemiluminescence, which involve electron transfer reactions between electrochemiluminophores and electrodes. The model takes into account the diffusion of particles, recombination rates, and emission processes, resulting in a system of nonlinear partial differential equations. Two types of ECL cell designs are considered: a cell with counter diffusion of anions and cations, and a cell with a thin film of electrochemiluminophore on the anode. The numerical solutions of the model equations are presented, and the results show that the cell with a thin film of electrochemiluminophore exhibits superior efficiency and a more favorable distribution of emitters. The study also estimates the photon yield in both types of cells and compares their light emission efficiency. The results indicate that the cell with a thin film of electrochemiluminophore would have significantly higher ECL efficiency than the cell with counter diffusion of anions and cations. Overall, this study provides a fundamental understanding of the processes involved in thin-layer ECL cells and offers valuable insights into the design and optimization of thin-layer ECL sensors and light emitters.

  • VS4 Nanodendrites with Narrow Bandgaps in Activating Dissolved Oxygen for Boosted Chemiluminescence and Hemin Detection by Unexpected Quenching

    by Abubakar Abdussalam, Hongzhan Liu, Islam Mohamed Mostafa, Baohua Lou, Dmytro Viktorovych Snizhko, Yuriy Tymofiiovych Zholudov, Wei Zhang, Guobao Xu

    Chemiluminescence (CL)-based analytical methods utilize luminophores that need to be activated with an oxidizing agent to trigger CL emission. Despite its susceptibility to decomposition when exposed to external light or trace metals, hydrogen peroxide (H2O2) has been widely used to develop chemiluminescent methods due to the limited number of suitable alternatives for activating chemiluminescent luminophores. Also, analytical methods based on the well-known luminol/H2O2 CL system have low sensitivity. Dissolved oxygen (DO) is a naturally abundant and environmentally benign alternative oxidant for luminol and other CL luminophores. However, DO alone is inactive and needs an efficient catalyst or a coreaction accelerator for its activation. Because of the narrow bandgap of VS4 (ca. 1.12 eV), it can facilitate fast electron-transfer kinetics with an acceptor molecule such as DO. Here, we introduce vanadium tetrasulfide (VS4) to boost CL for the first time. Under the optimized conditions, VS4 nanodendrite catalyzes the generation of reactive oxygen species by activating DO which subsequently reacts with luminol to generate intense CL. It enhances the CL intensity of luminol/DO by about 10,000 times. Surprisingly, hemin remarkably quenches the generated CL of luminol/DO/VS4 nanodendrites, which is completely opposite to its typical enhancement of luminol CL. Based on the remarkable concentration-dependent quenching of the luminol/DO/VS4 nanodendrite CL by hemin, we have developed a sensitive CL method that can selectively detect hemin in the linear concentration range of 1-250 nM and achieved a limit of detection of 0.11 nM. The practical utility of the developed method was demonstrated by the determination of hemin in a pharmaceutical drug for the treatment of acute intermittent porphyria and in human serum. This study demonstrates that VS4 holds great promise in analytical method development.


  • Open Access

    GLOSSY CARBON ELECTRODES WITH LASER-INDUCED PERIODIC SURFACE STRUCTURES FOR ELECTROCHEMILUMINESCENT ANALYSIS

    by Volodymyr Vasylkovskyi, Iaroslav Gnilitskyi, Dmytro Snizhko, Yuriy Zholudov, Mykola Slipchenko, Kateryna Muzyka

    In this paper, the possibility of using glassy carbon electrodes modified with laser-induced periodic surface structures for conducting electrochemical and electrochemiluminescent studies and creating appropriate analytical systems is investigated. Modification of the surface of the electrodes is carried out with the help of a femtosecond laser. The surface morphology of the modified electrodes by atomic force microscopy shows the stable formation of periodic surface structures. Electrochemiluminescence studies indicate the possibility of effective use of such modified electrodes for the creation of electrochemiluminescent analytical systems.


  • Much Stronger Chemiluminescence of 9-Mesityl-10-methylacridinium Ion than Lucigenin at Neutral Conditions for Co2+ Detection

    by Hongzhan Liu, Fangshuo Liu, Kaixiang Ji, Yuriy T. Zholudov, Islam M. Mostafa, Baohua Lou, Wei Zhang, Guobao Xu

    9-Mesityl-10-methylacridinium ion (Acr+-Mes) is a donor-acceptor molecule with a much longer lifetime and a higher energy electron transfer excited state than natural photosynthetic reaction centers. Unlike lucigenin with a coplanar geometry, Acr+-Mes has an orthogonal geometry. There is no π conjugation between Acr+ and Mes. Due to its special electron donor-acceptor structure, it does not rely on strong alkalinity to generate an electron transfer state like lucigenin, which makes it possible to achieve chemiluminescence (CL) under weakly alkaline or neutral conditions. In this study, we report Acr+-Mes CL for the first time. Acr+-Mes generates about 400 times stronger CL intensity than lucigenin under neutral conditions (pH = 7) using KHSO5 as the coreactant. Moreover, Co2+ can enhance Acr+-Mes/KHSO5 CL remarkably. Acr+-Mes/KHSO5 CL enables Co2+ detection with a linear range of 0.5-500 nM and a limit of detection of 28 pM (S/N = 3). This method was tested for the detection of Co2+ in lake water, and the standard recovery rate of 96.8-107% was achieved. This study provides a new way to develop efficient CL systems in neutral solutions.


  • Open Access

    Laser Synthesis of Cerium-Doped Garnet Nanoparticles

    by Volodymyr Vasylkovskyi, Iryna Bespalova, Andrey Evlyukhin, Yuriy Zholudov, Iaroslav Gerasymov, Daniil Kurtsev, Denys Kofanov, Olena Slipchenko, Mykola Slipchenko, Boris Chichkov

    The application of a pulsed laser ablation technique for the generation of cerium-doped garnet nanoparticles in liquids is investigated. The morphological and optical properties of the obtained nanoparticles are demonstrated. Features introduced by the single crystals of Gd3Al2.4Ga2.6O12:Ce3+, Lu3Al5O12:Ce3+, and Y3Al1.25Ga3.75O12:Ce3+ from which the nanoparticles are generated, as well as the parameters of a liquid media on the garnet nanoparticle generation are experimentally studied using TEM and UV-Vis spectroscopy methods. It is shown how the size, shape, and internal structure of the nanoparticles are related to the external laser ablation conditions, as well as to the laser melting processes of NPs in the colloidal solutions. This work provides important information about the generated nanoparticles, which can be used as building blocks for specially designed structures with predetermined optical properties.