Zhen Ren
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Zhen Ren has a total of 46 co-authors. Here are the top co-authors by number of shared publications:
- Gregory S. Karczmar
Department of Radiology, The University of Chicago, 5841 S Maryland Ave, MC 2026, Chicago, IL 60637
5 shared publications - Hiroyuki Abe
Department of Radiology, The University of Chicago, 5841 S Maryland Ave, MC 2026, Chicago, IL 60637
4 shared publications Gregory S. Karczmar
Department of Radiology The University of Chicago Chicago Illinois USA
3 shared publications- Kirti Kulkarni
Department of Radiology, The University of Chicago, Chicago, IL 60637, United States of America
3 shared publications Federico D. Pineda
Affiliation Department of Radiology, The University of Pittsburgh, Pittsburgh, Pennsylvania, United States of America
2 shared publicationsFrederick M. Howard
Section of Hematology and Oncology Department of Medicine The University of Chicago Chicago Illinois USA
2 shared publications
Latest Publications
- 1 March 2026
- Published by Radiological Society of North America (RSNA) in Radiology: Imaging Cancer
- Vol. 8 (2) , e250432
Automated Cluster-based Quantitative Analysis of Ultrafast DCE MRI for Differential Breast DCIS Grading
K-means clustering–based quantitative analysis of ultrafast dynamic contrast-enhanced MRI kinetics enabled segmentation-free ductal carcinoma in situ (DCIS) grade classification; contrast agent uptake rate was associated with DCIS grades and performed best for identifying low-grade DCIS.
- 1 March 2026
- Published by Radiological Society of North America (RSNA) in Radiology: Imaging Cancer
- Vol. 8 (2) , e250432
Automated Cluster-based Quantitative Analysis of Ultrafast DCE MRI for Differential Breast DCIS Grading
K-means clustering–based quantitative analysis of ultrafast dynamic contrast-enhanced MRI kinetics enabled segmentation-free ductal carcinoma in situ (DCIS) grade classification; contrast agent uptake rate was associated with DCIS grades and performed best for identifying low-grade DCIS.
- Open Access
- 28 December 2025
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 27 (1) , e70439
K‐means clustering‐based analysis of quantitative ultrafast DCE‐MRI for predicting breast cancer response to neoadjuvant chemotherapy
Purpose: Achieving a pathologic complete response (pCR) following neoadjuvant chemotherapy (NAC) is strongly associated with improved survival. This study investigates whether bilateral asymmetry of quantitative perfusion parameters in normal parenchyma from ultrafast dynamic contrast‐enhanced MRI (DCE‐MRI), measured using k‐means clustering (KMC) before NAC, can predict pCR in breast cancer patients. Materials and methods: Fifty‐six breast cancer patients undergoing NAC with pretreatment ultrafast DCE‐MRI (3–9 s/image at 3T) were enrolled. KMC was used to classify tumor and normal parenchymal voxels into five clusters based on maximum enhancement rate ( A·α ). Ipsilateral‐to‐contralateral (I/C) ratios of background parenchymal enhancement kinetics (kBPE) and tumor kinetics (kT) were compared between pCR and nonpCR groups. Logistic regression models were developed to predict pCR. Statistical tests included bootstrapping, z‐test, chi‐square, and Wilcoxon rank‐sum. Results: Patients with residual disease showed significantly higher kBPE in the normal‐appearing parenchyma of the ipsilateral breast compared to the contralateral side. Parameters including enhancement rate α, A·α , area under the enhancement curve for 30 s AUC30 , volume transfer constant K tran s , and rate constant of contrast transfer, K ep , were significantly higher, while extravascular extracellular space fractional volume, v e , was significantly lower in the ipsilateral breast parenchyma versus contralateral breast parenchyma for women who have residual disease ( p < 0.05). A prediction model using kBPE asymmetry alone achieved an area under the curve (AUC) of 0.83. Including tumor kinetics improved the AUC to 0.85. Conclusions: Bilateral asymmetry of kBPE parameters derived from ultrafast DCE‐MRI using KMC before NAC initiation can predict pCR with high accuracy, providing a new minimal‐invasive biomarker for treatment response.
- 28 December 2025
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 27 (1) , e70439
Open AccessK‐means clustering‐based analysis of quantitative ultrafast DCE‐MRI for predicting breast cancer response to neoadjuvant chemotherapy
Purpose: Achieving a pathologic complete response (pCR) following neoadjuvant chemotherapy (NAC) is strongly associated with improved survival. This study investigates whether bilateral asymmetry of quantitative perfusion parameters in normal parenchyma from ultrafast dynamic contrast‐enhanced MRI (DCE‐MRI), measured using k‐means clustering (KMC) before NAC, can predict pCR in breast cancer patients. Materials and methods: Fifty‐six breast cancer patients undergoing NAC with pretreatment ultrafast DCE‐MRI (3–9 s/image at 3T) were enrolled. KMC was used to classify tumor and normal parenchymal voxels into five clusters based on maximum enhancement rate ( A·α ). Ipsilateral‐to‐contralateral (I/C) ratios of background parenchymal enhancement kinetics (kBPE) and tumor kinetics (kT) were compared between pCR and nonpCR groups. Logistic regression models were developed to predict pCR. Statistical tests included bootstrapping, z‐test, chi‐square, and Wilcoxon rank‐sum. Results: Patients with residual disease showed significantly higher kBPE in the normal‐appearing parenchyma of the ipsilateral breast compared to the contralateral side. Parameters including enhancement rate α, A·α , area under the enhancement curve for 30 s AUC30 , volume transfer constant K tran s , and rate constant of contrast transfer, K ep , were significantly higher, while extravascular extracellular space fractional volume, v e , was significantly lower in the ipsilateral breast parenchyma versus contralateral breast parenchyma for women who have residual disease ( p < 0.05). A prediction model using kBPE asymmetry alone achieved an area under the curve (AUC) of 0.83. Including tumor kinetics improved the AUC to 0.85. Conclusions: Bilateral asymmetry of kBPE parameters derived from ultrafast DCE‐MRI using KMC before NAC initiation can predict pCR with high accuracy, providing a new minimal‐invasive biomarker for treatment response.
- Open Access
- 1 November 2025
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 15 (11) , 10582-10594
Ultrafast breast DCE-MRI: comparative analysis of semi-quantitative and pharmacokinetic parameters with gadoterate meglumine versus gadobutrol in malignant lesions and background parenchymal enhancement
Background: There is increasing interest in high temporal resolution imaging techniques in breast magnetic resonance imaging (MRI) for breast cancer detection. The purpose of this study was to compare diagnostic performance and kinetic characteristics of gadoterate meglumine (Dotarem®) and gadobutrol (Gadavist®) in ultrafast breast dynamic contrast-enhanced MRI (DCE-MRI), focusing on semi-quantitative and pharmacokinetic parameters for differentiating malignant lesions from background parenchymal enhancement (BPE). Methods: Ultrafast DCE-MRI acquisition is a high temporal resolution (3.5–4.6 seconds) imaging technique used during the first minute following contrast injection to obtain three-dimensional (3D) whole breast images. All ultrafast images were motion-corrected by a non-rigid registration method. This retrospective study evaluated 60 lesions enhanced with Dotarem and 34 with Gadavist. Semi-automatic volumetric segmentation of the lesions was performed with 3D Slicer. Signal enhancement ratio over time was fitted with an empirical mathematic model (EMM) by using each voxel within the lesion and selected normal parenchymal regions of interest (ROIs). Quantitative pharmacokinetic parameters, including Ktrans (volume transfer constant) and Ve [extravascular extracellular space (EES) fractional volume], are calculated with the Tofts model. The individual arterial input function (AIF) was traced over an ROI within the descending thoracic aorta that was utilized to calibrate the time course of average signal intensity. Diagnostic performance was measured by sensitivity, specificity, and area under the receiver operating characteristic curve (AUROC) at Youden-optimized thresholds. Inter-agent comparisons included Wilcoxon rank-sum testing and Cohen’s d effect sizes. Results: A total of 94 histopathologically confirmed breast lesions were analyzed, comprising 60 Dotarem-enhanced and 34 Gadavist-enhanced lesions. Gadavist demonstrated a steeper early wash-in slope (≈60% vs. 40% signal increase at 20 seconds) and higher absolute tumor enhancement. Dotarem exhibited greater tumor-to-BPE contrast due to lower BPE, improving lesion conspicuity. Amplitude-based kinetic parameters [upper limit of enhancement (A), uptake rate (α), maximal enhancement slope (A*α), area under the enhancement-time curve for the first 30 seconds (AUC30)] most effectively distinguished malignant lesions from BPE (Ptrans (all Ptrans (P vs. 0.58; P=0.036); however, the clinical significance of this difference remains uncertain. Conclusions: In ultrafast breast DCE-MRI, Gadavist demonstrated stronger early enhancement kinetics, whereas Dotarem provided improved tumor-to-BPE contrast and higher sensitivity for select kinetic parameters. These findings underscore the importance of tailoring contrast agent selection to specific diagnostic goals.
- 1 November 2025
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 15 (11) , 10582-10594
Open AccessUltrafast breast DCE-MRI: comparative analysis of semi-quantitative and pharmacokinetic parameters with gadoterate meglumine versus gadobutrol in malignant lesions and background parenchymal enhancement
Background: There is increasing interest in high temporal resolution imaging techniques in breast magnetic resonance imaging (MRI) for breast cancer detection. The purpose of this study was to compare diagnostic performance and kinetic characteristics of gadoterate meglumine (Dotarem®) and gadobutrol (Gadavist®) in ultrafast breast dynamic contrast-enhanced MRI (DCE-MRI), focusing on semi-quantitative and pharmacokinetic parameters for differentiating malignant lesions from background parenchymal enhancement (BPE). Methods: Ultrafast DCE-MRI acquisition is a high temporal resolution (3.5–4.6 seconds) imaging technique used during the first minute following contrast injection to obtain three-dimensional (3D) whole breast images. All ultrafast images were motion-corrected by a non-rigid registration method. This retrospective study evaluated 60 lesions enhanced with Dotarem and 34 with Gadavist. Semi-automatic volumetric segmentation of the lesions was performed with 3D Slicer. Signal enhancement ratio over time was fitted with an empirical mathematic model (EMM) by using each voxel within the lesion and selected normal parenchymal regions of interest (ROIs). Quantitative pharmacokinetic parameters, including Ktrans (volume transfer constant) and Ve [extravascular extracellular space (EES) fractional volume], are calculated with the Tofts model. The individual arterial input function (AIF) was traced over an ROI within the descending thoracic aorta that was utilized to calibrate the time course of average signal intensity. Diagnostic performance was measured by sensitivity, specificity, and area under the receiver operating characteristic curve (AUROC) at Youden-optimized thresholds. Inter-agent comparisons included Wilcoxon rank-sum testing and Cohen’s d effect sizes. Results: A total of 94 histopathologically confirmed breast lesions were analyzed, comprising 60 Dotarem-enhanced and 34 Gadavist-enhanced lesions. Gadavist demonstrated a steeper early wash-in slope (≈60% vs. 40% signal increase at 20 seconds) and higher absolute tumor enhancement. Dotarem exhibited greater tumor-to-BPE contrast due to lower BPE, improving lesion conspicuity. Amplitude-based kinetic parameters [upper limit of enhancement (A), uptake rate (α), maximal enhancement slope (A*α), area under the enhancement-time curve for the first 30 seconds (AUC30)] most effectively distinguished malignant lesions from BPE (Ptrans (all Ptrans (P vs. 0.58; P=0.036); however, the clinical significance of this difference remains uncertain. Conclusions: In ultrafast breast DCE-MRI, Gadavist demonstrated stronger early enhancement kinetics, whereas Dotarem provided improved tumor-to-BPE contrast and higher sensitivity for select kinetic parameters. These findings underscore the importance of tailoring contrast agent selection to specific diagnostic goals.
- Open Access
- 1 October 2025
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 15 (10) , 8755-8767
Clinical application of gadoterate meglumine in abbreviated dynamic contrast-enhanced magnetic resonance imaging of the breast with ultrafast imaging: a single-center retrospective study
Background: There is increasing interest in high temporal resolution imaging techniques in breast magnetic resonance imaging (MRI) for breast cancer detection. The purpose of this study was to evaluate the clinical application of gadoterate meglumine (Dotarem) in abbreviated dynamic contrast-enhanced MRI (DCE-MRI) of the breast for cancer detection, focusing on quantitative kinetic analysis with ultrafast DCE-MRI. Methods: Ultrafast acquisition is a high temporal resolution (3.5–4.6 seconds) imaging technique used during the first minute following contrast injection to obtain three-dimensional (3D) whole breast images. All ultrafast DCE-MRIs were motion-corrected by a non-rigid registration method. A retrospective study was performed for 49 patients with 60 malignant lesions and 2 benign lesions. Background parenchymal enhancement (BPE) was evaluated in 47 of the patients because two patients had breast implants. Semi-automatic volumetric segmentation of the lesions was performed with 3D Slicer. Signal enhancement ratio (SER) over time was fitted with an empirical mathematical model (EMM) by using each voxel within the lesion and selected normal parenchymal regions of interest (ROIs). Quantitative pharmacokinetic parameters, including transfer constant (Ktrans) and fractional volume of the extravascular extracellular space (ve), are calculated with the Tofts model. The individual arterial input function (AIF) was traced over an ROI within the descending thoracic aorta that was utilized to calibrate the time course of average signal intensity. Mean values of kinetic parameters for malignant lesions and BPE were compared with Welch’s t-test for normally distributed variables and the Mann-Whitney U test for non-normally distributed variables. The average ratio of malignant lesions to BPE was computed. Area under the receiver operating characteristic curve (AUC), sensitivity, and specificity at the optimal cutoff point as determined by Youden’s index and 95% confidence interval (CI) were calculated for each parameter to separate the malignant lesions from the BPE. Results: Higher signal enhancement in malignant lesions than signal in BPE was observed in the time course of ultrafast DCE-MRI. The ratio of Ktrans for malignant lesions to BPE is 15.58±14.35 [standard deviation (SD)]. The maximum enhancement slope (A*α), area under the enhancement-time curve over 30 seconds (AUC30), upper limit of initial contrast agent uptake (A), and Ktrans demonstrated excellent discriminating performance for cancer detection, with corresponding AUCs of 0.963, 0.963, 0.955, and 0.938, respectively, listed in descending order of discriminative power. Ktrans had the highest diagnostic sensitivity [98.3% (95% CI: 91.1–100%), PConclusions: Based on quantitative pharmacokinetic analysis of ultrafast DCE-MRI, the study demonstrated the viability of utilizing Dotarem as an intravenous gadolinium-based contrast agent for DCE-MRI of the breast with preserved clinical success for breast cancer detection.
- 1 October 2025
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 15 (10) , 8755-8767
Open AccessClinical application of gadoterate meglumine in abbreviated dynamic contrast-enhanced magnetic resonance imaging of the breast with ultrafast imaging: a single-center retrospective study
Background: There is increasing interest in high temporal resolution imaging techniques in breast magnetic resonance imaging (MRI) for breast cancer detection. The purpose of this study was to evaluate the clinical application of gadoterate meglumine (Dotarem) in abbreviated dynamic contrast-enhanced MRI (DCE-MRI) of the breast for cancer detection, focusing on quantitative kinetic analysis with ultrafast DCE-MRI. Methods: Ultrafast acquisition is a high temporal resolution (3.5–4.6 seconds) imaging technique used during the first minute following contrast injection to obtain three-dimensional (3D) whole breast images. All ultrafast DCE-MRIs were motion-corrected by a non-rigid registration method. A retrospective study was performed for 49 patients with 60 malignant lesions and 2 benign lesions. Background parenchymal enhancement (BPE) was evaluated in 47 of the patients because two patients had breast implants. Semi-automatic volumetric segmentation of the lesions was performed with 3D Slicer. Signal enhancement ratio (SER) over time was fitted with an empirical mathematical model (EMM) by using each voxel within the lesion and selected normal parenchymal regions of interest (ROIs). Quantitative pharmacokinetic parameters, including transfer constant (Ktrans) and fractional volume of the extravascular extracellular space (ve), are calculated with the Tofts model. The individual arterial input function (AIF) was traced over an ROI within the descending thoracic aorta that was utilized to calibrate the time course of average signal intensity. Mean values of kinetic parameters for malignant lesions and BPE were compared with Welch’s t-test for normally distributed variables and the Mann-Whitney U test for non-normally distributed variables. The average ratio of malignant lesions to BPE was computed. Area under the receiver operating characteristic curve (AUC), sensitivity, and specificity at the optimal cutoff point as determined by Youden’s index and 95% confidence interval (CI) were calculated for each parameter to separate the malignant lesions from the BPE. Results: Higher signal enhancement in malignant lesions than signal in BPE was observed in the time course of ultrafast DCE-MRI. The ratio of Ktrans for malignant lesions to BPE is 15.58±14.35 [standard deviation (SD)]. The maximum enhancement slope (A*α), area under the enhancement-time curve over 30 seconds (AUC30), upper limit of initial contrast agent uptake (A), and Ktrans demonstrated excellent discriminating performance for cancer detection, with corresponding AUCs of 0.963, 0.963, 0.955, and 0.938, respectively, listed in descending order of discriminative power. Ktrans had the highest diagnostic sensitivity [98.3% (95% CI: 91.1–100%), PConclusions: Based on quantitative pharmacokinetic analysis of ultrafast DCE-MRI, the study demonstrated the viability of utilizing Dotarem as an intravenous gadolinium-based contrast agent for DCE-MRI of the breast with preserved clinical success for breast cancer detection.
- Open Access
- 1 June 2025
- Published by SAGE Publications in Technology in Cancer Research & Treatment
- Vol. 24
A Translational Research Leveraging Diagnostic Accuracy of Innovations in MRI as a Model for Early Breast Cancer Detection in Uganda
Introduction: Breast cancer remains a leading cause of cancer-related morbidity and mortality in sub-Saharan Africa, with Uganda experiencing a reported 5% annual increase in cases. Alarmingly, 87% of women in Uganda present with advanced-stage disease that is less responsive to treatment, contributing to the region's disproportionately low survival rate. Early breast cancer detection will be the fundamental intervention to reverse the mortality resulting from breast cancer in Uganda. This study aims to enhance breast cancer screening and early detection in Ugandan women who are at risk through innovative use of quantitative MRI to differentiate between benign and malignant breast lesions for women at risk. Methods: The study prospectively recruited women at risk of breast cancer who underwent breast ultrafast DCE-MRI from July 2023 to April 2024. A 3.0-T MRI system with a16 channel breast dedicated coil was used with scan durations of up to 10 min. The T1 weighted pre-contrast, T1 weighted post-contrast, T1 weighted dynamic subtracted and Maximum Intensity projection (MIP) sequences were acquired and the histology blinded pharmacokinetic analysis for the breast lesion was done. The initial area under the curve in 30 s after contrast injection ( iAUC30 ), MaxSlope , K trans , BAT , and υ e were calculated and used to assess the diagnostic performance. Results: A total of 52 women were recruited and imaged and 36 lesions were found. Unlike the MaxSlope , K trans , BAT and υ e the iAUC30 values exhibited significant differences between benign and malignant lesions with a P -value <.005 and the area under the ROC curve ( iAUC30 ) was 0.9147. The sensitivity, specificity, PPV and NPV of MRI using histology as the gold standard at 95% confidence interval were 70%, 100%, 100% and 73.9% respectively. Conclusions: Abbreviated DCE-MRI protocols with quantitative analysis can effectively differentiate malignant from benign breast lesions with improved compliance and can be adopted as a model of breast cancer screening and early detection for women at risk.
- 1 June 2025
- Published by SAGE Publications in Technology in Cancer Research & Treatment
- Vol. 24
Open AccessA Translational Research Leveraging Diagnostic Accuracy of Innovations in MRI as a Model for Early Breast Cancer Detection in Uganda
Introduction: Breast cancer remains a leading cause of cancer-related morbidity and mortality in sub-Saharan Africa, with Uganda experiencing a reported 5% annual increase in cases. Alarmingly, 87% of women in Uganda present with advanced-stage disease that is less responsive to treatment, contributing to the region's disproportionately low survival rate. Early breast cancer detection will be the fundamental intervention to reverse the mortality resulting from breast cancer in Uganda. This study aims to enhance breast cancer screening and early detection in Ugandan women who are at risk through innovative use of quantitative MRI to differentiate between benign and malignant breast lesions for women at risk. Methods: The study prospectively recruited women at risk of breast cancer who underwent breast ultrafast DCE-MRI from July 2023 to April 2024. A 3.0-T MRI system with a16 channel breast dedicated coil was used with scan durations of up to 10 min. The T1 weighted pre-contrast, T1 weighted post-contrast, T1 weighted dynamic subtracted and Maximum Intensity projection (MIP) sequences were acquired and the histology blinded pharmacokinetic analysis for the breast lesion was done. The initial area under the curve in 30 s after contrast injection ( iAUC30 ), MaxSlope , K trans , BAT , and υ e were calculated and used to assess the diagnostic performance. Results: A total of 52 women were recruited and imaged and 36 lesions were found. Unlike the MaxSlope , K trans , BAT and υ e the iAUC30 values exhibited significant differences between benign and malignant lesions with a P -value <.005 and the area under the ROC curve ( iAUC30 ) was 0.9147. The sensitivity, specificity, PPV and NPV of MRI using histology as the gold standard at 95% confidence interval were 70%, 100%, 100% and 73.9% respectively. Conclusions: Abbreviated DCE-MRI protocols with quantitative analysis can effectively differentiate malignant from benign breast lesions with improved compliance and can be adopted as a model of breast cancer screening and early detection for women at risk.
- Open Access
- 15 June 2023
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 18 (6) , e0286123
Pharmacokinetic Analysis of Enhancement-Constrained Acceleration (ECA) reconstruction-based high temporal resolution breast DCE-MRI
The high spatial and temporal resolution of dynamic contrast-enhanced MRI (DCE-MRI) can improve the diagnostic accuracy of breast cancer screening in patients who have dense breasts or are at high risk of breast cancer. However, the spatiotemporal resolution of DCE-MRI is limited by technical issues in clinical practice. Our earlier work demonstrated the use of image reconstruction with enhancement-constrained acceleration (ECA) to increase temporal resolution. ECA exploits the correlation in k-space between successive image acquisitions. Because of this correlation, and due to the very sparse enhancement at early times after contrast media injection, we can reconstruct images from highly under-sampled k-space data. Our previous results showed that ECA reconstruction at 0.25 seconds per image (4 Hz) can estimate bolus arrival time (BAT) and initial enhancement slope (iSlope) more accurately than a standard inverse fast Fourier transform (IFFT) when k-space data is sampled following a Cartesian based sampling trajectory with adequate signal-to-noise ratio (SNR). In this follow-up study, we investigated the effect of different Cartesian based sampling trajectories, SNRs and acceleration rates on the performance of ECA reconstruction in estimating contrast media kinetics in lesions (BAT, iSlope and Ktrans) and in arteries (Peak signal intensity of first pass, time to peak, and BAT). We further validated ECA reconstruction with a flow phantom experiment. Our results show that ECA reconstruction of k-space data acquired with ‘Under-sampling with Repeated Advancing Phase’ (UnWRAP) trajectories with an acceleration factor of 14, and temporal resolution of 0.5 s/image and high SNR (SNR ≥ 30 dB, noise standard deviation (std) < 3%) ensures minor errors (5% or 1 s error) in lesion kinetics. Medium SNR (SNR ≥ 20 dB, noise std ≤ 10%) was needed to accurately measure arterial enhancement kinetics. Our results also suggest that accelerated temporal resolution with ECA with 0.5 s/image is practical.
- 15 June 2023
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 18 (6) , e0286123
Open AccessPharmacokinetic Analysis of Enhancement-Constrained Acceleration (ECA) reconstruction-based high temporal resolution breast DCE-MRI
The high spatial and temporal resolution of dynamic contrast-enhanced MRI (DCE-MRI) can improve the diagnostic accuracy of breast cancer screening in patients who have dense breasts or are at high risk of breast cancer. However, the spatiotemporal resolution of DCE-MRI is limited by technical issues in clinical practice. Our earlier work demonstrated the use of image reconstruction with enhancement-constrained acceleration (ECA) to increase temporal resolution. ECA exploits the correlation in k-space between successive image acquisitions. Because of this correlation, and due to the very sparse enhancement at early times after contrast media injection, we can reconstruct images from highly under-sampled k-space data. Our previous results showed that ECA reconstruction at 0.25 seconds per image (4 Hz) can estimate bolus arrival time (BAT) and initial enhancement slope (iSlope) more accurately than a standard inverse fast Fourier transform (IFFT) when k-space data is sampled following a Cartesian based sampling trajectory with adequate signal-to-noise ratio (SNR). In this follow-up study, we investigated the effect of different Cartesian based sampling trajectories, SNRs and acceleration rates on the performance of ECA reconstruction in estimating contrast media kinetics in lesions (BAT, iSlope and Ktrans) and in arteries (Peak signal intensity of first pass, time to peak, and BAT). We further validated ECA reconstruction with a flow phantom experiment. Our results show that ECA reconstruction of k-space data acquired with ‘Under-sampling with Repeated Advancing Phase’ (UnWRAP) trajectories with an acceleration factor of 14, and temporal resolution of 0.5 s/image and high SNR (SNR ≥ 30 dB, noise standard deviation (std) < 3%) ensures minor errors (5% or 1 s error) in lesion kinetics. Medium SNR (SNR ≥ 20 dB, noise std ≤ 10%) was needed to accurately measure arterial enhancement kinetics. Our results also suggest that accelerated temporal resolution with ECA with 0.5 s/image is practical.
- 26 March 2022
- Published by Elsevier in Academic Radiology
- Vol. 29 (10) , 1469-1479
Differences Between Ipsilateral and Contralateral Early Parenchymal Enhancement Kinetics Predict Response of Breast Cancer to Neoadjuvant Therapy
- 26 March 2022
- Published by Elsevier in Academic Radiology
- Vol. 29 (10) , 1469-1479
Differences Between Ipsilateral and Contralateral Early Parenchymal Enhancement Kinetics Predict Response of Breast Cancer to Neoadjuvant Therapy
- 23 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 68 (3) , 754-761
Development of a Novel Linear ERT Sensor to Measure Surface Deposits
This paper investigates the feasibility of using electrical resistance tomography (ERT) to visualize the surface deposit during a cleaning-in-place (CIP) process, which is a common problem in various industries. A pilot scale cleaning rig with a purposely designed ERT test section was used for monitoring the prerinse CIP stage of cleaning milk paste adhering to a test section. The ERT test section comprises a CIP-ERT multilinear sensor consisting of four planes of eight electrodes. The industrial tomography system, P2000 ERT system, was used to collect the voltage data that were processed in a MATLAB-based ERT toolkit. 3-D images were reconstructed using the L-curve Tikhonov method. A feasibility study was conducted to evaluate the performance of the CIP-ERT sensor. Image analysis showed that ERT is suitable for monitoring and visualizing the CIP process for the materials that foul similar to milk pastes. The success of this paper contributes to a time/energy efficient industrial process as the cleaning process can be visualized and over cleaning can be avoided.
- 23 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 68 (3) , 754-761
Development of a Novel Linear ERT Sensor to Measure Surface Deposits
This paper investigates the feasibility of using electrical resistance tomography (ERT) to visualize the surface deposit during a cleaning-in-place (CIP) process, which is a common problem in various industries. A pilot scale cleaning rig with a purposely designed ERT test section was used for monitoring the prerinse CIP stage of cleaning milk paste adhering to a test section. The ERT test section comprises a CIP-ERT multilinear sensor consisting of four planes of eight electrodes. The industrial tomography system, P2000 ERT system, was used to collect the voltage data that were processed in a MATLAB-based ERT toolkit. 3-D images were reconstructed using the L-curve Tikhonov method. A feasibility study was conducted to evaluate the performance of the CIP-ERT sensor. Image analysis showed that ERT is suitable for monitoring and visualizing the CIP process for the materials that foul similar to milk pastes. The success of this paper contributes to a time/energy efficient industrial process as the cleaning process can be visualized and over cleaning can be avoided.
- 17 June 2018
- Published by ASME International
Numerical Simulations of Ship Bow and Shoulder Wave Breaking in Different Advancing Speeds
The KCS model is employed for the numerical simulations to investigate the wave breaking phenomena of the bow and shoulder wave. RANS approach coupled with high resolution VOF technique is used to resolve the free surface. In order to study the speed effects on the phenomena of ship wave breaking, four different speeds, i.e. Fr = 0.26, 0.30, 0.32, 0.35, are investigated in calm water. Predicted resistance and wave patterns under Fr = 0.26 are validated with the available experiment data, and good agreement is achieved. For the Fr = 0.26 case, the wave pattern is steady, and the alternate variation of vorticity appear near the free surface is associated with the wake field. The breaking wave phenomena can be observed when the Froude number is over 0.32 and the Fr = 0.35 case shows most violent breaking bow wave. For the Fr = 0.35 case, the process of overturning and breaking of bow wave is observed clearly, and at the tail of bow wave, some breaking features of free surface are also captured. The reconnection of the initial plunger with the free surface results in a pair of counter-rotating vortex that is responsible for the second plunger and scar.
- 17 June 2018
- Published by ASME International
Numerical Simulations of Ship Bow and Shoulder Wave Breaking in Different Advancing Speeds
The KCS model is employed for the numerical simulations to investigate the wave breaking phenomena of the bow and shoulder wave. RANS approach coupled with high resolution VOF technique is used to resolve the free surface. In order to study the speed effects on the phenomena of ship wave breaking, four different speeds, i.e. Fr = 0.26, 0.30, 0.32, 0.35, are investigated in calm water. Predicted resistance and wave patterns under Fr = 0.26 are validated with the available experiment data, and good agreement is achieved. For the Fr = 0.26 case, the wave pattern is steady, and the alternate variation of vorticity appear near the free surface is associated with the wake field. The breaking wave phenomena can be observed when the Froude number is over 0.32 and the Fr = 0.35 case shows most violent breaking bow wave. For the Fr = 0.35 case, the process of overturning and breaking of bow wave is observed clearly, and at the tail of bow wave, some breaking features of free surface are also captured. The reconnection of the initial plunger with the free surface results in a pair of counter-rotating vortex that is responsible for the second plunger and scar.