KKKirti Kulkarni

Kirti Kulkarni

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Kirti Kulkarni has a total of 8 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Ultrafast breast DCE-MRI: comparative analysis of semi-quantitative and pharmacokinetic parameters with gadoterate meglumine versus gadobutrol in malignant lesions and background parenchymal enhancement

    by Saengsiri Chumsaengsri, Hiroyuki Abe, Gregory S. Karczmar, Zhen Ren, Kirti Kulkarni

    Background: There is increasing interest in high temporal resolution imaging techniques in breast magnetic resonance imaging (MRI) for breast cancer detection. The purpose of this study was to compare diagnostic performance and kinetic characteristics of gadoterate meglumine (Dotarem®) and gadobutrol (Gadavist®) in ultrafast breast dynamic contrast-enhanced MRI (DCE-MRI), focusing on semi-quantitative and pharmacokinetic parameters for differentiating malignant lesions from background parenchymal enhancement (BPE). Methods: Ultrafast DCE-MRI acquisition is a high temporal resolution (3.5–4.6 seconds) imaging technique used during the first minute following contrast injection to obtain three-dimensional (3D) whole breast images. All ultrafast images were motion-corrected by a non-rigid registration method. This retrospective study evaluated 60 lesions enhanced with Dotarem and 34 with Gadavist. Semi-automatic volumetric segmentation of the lesions was performed with 3D Slicer. Signal enhancement ratio over time was fitted with an empirical mathematic model (EMM) by using each voxel within the lesion and selected normal parenchymal regions of interest (ROIs). Quantitative pharmacokinetic parameters, including Ktrans (volume transfer constant) and Ve [extravascular extracellular space (EES) fractional volume], are calculated with the Tofts model. The individual arterial input function (AIF) was traced over an ROI within the descending thoracic aorta that was utilized to calibrate the time course of average signal intensity. Diagnostic performance was measured by sensitivity, specificity, and area under the receiver operating characteristic curve (AUROC) at Youden-optimized thresholds. Inter-agent comparisons included Wilcoxon rank-sum testing and Cohen’s d effect sizes. Results: A total of 94 histopathologically confirmed breast lesions were analyzed, comprising 60 Dotarem-enhanced and 34 Gadavist-enhanced lesions. Gadavist demonstrated a steeper early wash-in slope (≈60% vs. 40% signal increase at 20 seconds) and higher absolute tumor enhancement. Dotarem exhibited greater tumor-to-BPE contrast due to lower BPE, improving lesion conspicuity. Amplitude-based kinetic parameters [upper limit of enhancement (A), uptake rate (α), maximal enhancement slope (A*α), area under the enhancement-time curve for the first 30 seconds (AUC30)] most effectively distinguished malignant lesions from BPE (Ptrans (all Ptrans (P vs. 0.58; P=0.036); however, the clinical significance of this difference remains uncertain. Conclusions: In ultrafast breast DCE-MRI, Gadavist demonstrated stronger early enhancement kinetics, whereas Dotarem provided improved tumor-to-BPE contrast and higher sensitivity for select kinetic parameters. These findings underscore the importance of tailoring contrast agent selection to specific diagnostic goals.

  • Open Access

    Clinical application of gadoterate meglumine in abbreviated dynamic contrast-enhanced magnetic resonance imaging of the breast with ultrafast imaging: a single-center retrospective study

    by Saengsiri Chumsaengsri, Hiroyuki Abe, Gregory S. Karczmar, Zhen Ren, Kirti Kulkarni

    Background: There is increasing interest in high temporal resolution imaging techniques in breast magnetic resonance imaging (MRI) for breast cancer detection. The purpose of this study was to evaluate the clinical application of gadoterate meglumine (Dotarem) in abbreviated dynamic contrast-enhanced MRI (DCE-MRI) of the breast for cancer detection, focusing on quantitative kinetic analysis with ultrafast DCE-MRI. Methods: Ultrafast acquisition is a high temporal resolution (3.5–4.6 seconds) imaging technique used during the first minute following contrast injection to obtain three-dimensional (3D) whole breast images. All ultrafast DCE-MRIs were motion-corrected by a non-rigid registration method. A retrospective study was performed for 49 patients with 60 malignant lesions and 2 benign lesions. Background parenchymal enhancement (BPE) was evaluated in 47 of the patients because two patients had breast implants. Semi-automatic volumetric segmentation of the lesions was performed with 3D Slicer. Signal enhancement ratio (SER) over time was fitted with an empirical mathematical model (EMM) by using each voxel within the lesion and selected normal parenchymal regions of interest (ROIs). Quantitative pharmacokinetic parameters, including transfer constant (Ktrans) and fractional volume of the extravascular extracellular space (ve), are calculated with the Tofts model. The individual arterial input function (AIF) was traced over an ROI within the descending thoracic aorta that was utilized to calibrate the time course of average signal intensity. Mean values of kinetic parameters for malignant lesions and BPE were compared with Welch’s t-test for normally distributed variables and the Mann-Whitney U test for non-normally distributed variables. The average ratio of malignant lesions to BPE was computed. Area under the receiver operating characteristic curve (AUC), sensitivity, and specificity at the optimal cutoff point as determined by Youden’s index and 95% confidence interval (CI) were calculated for each parameter to separate the malignant lesions from the BPE. Results: Higher signal enhancement in malignant lesions than signal in BPE was observed in the time course of ultrafast DCE-MRI. The ratio of Ktrans for malignant lesions to BPE is 15.58±14.35 [standard deviation (SD)]. The maximum enhancement slope (A*α), area under the enhancement-time curve over 30 seconds (AUC30), upper limit of initial contrast agent uptake (A), and Ktrans demonstrated excellent discriminating performance for cancer detection, with corresponding AUCs of 0.963, 0.963, 0.955, and 0.938, respectively, listed in descending order of discriminative power. Ktrans had the highest diagnostic sensitivity [98.3% (95% CI: 91.1–100%), PConclusions: Based on quantitative pharmacokinetic analysis of ultrafast DCE-MRI, the study demonstrated the viability of utilizing Dotarem as an intravenous gadolinium-based contrast agent for DCE-MRI of the breast with preserved clinical success for breast cancer detection.

  • Bilateral asymmetry of quantitative parenchymal kinetics at ultrafast DCE-MRI predict response to neoadjuvant chemotherapy in patients with HER2+ breast cancer

    by Zhen Ren, Federico D. Pineda, Frederick M. Howard, Xiaobing Fan, Rita Nanda, Hiroyuki Abe, Kirti Kulkarni, Gregory S. Karczmar