Zhou Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Zhou Liu has a total of 87 co-authors. Here are the top co-authors by number of shared publications:
- Zhe Chen
School of Economics and Management, Beihang University, Beijing, China
23 shared publications Yanting Hu
Department of Engineering and Physics Science, Glyndwr University, Wrexham, UK
8 shared publications- Chengxi Liu
Wuhan University
6 shared publications Haishun Sun
State key laboratory of strong electromagnetic engineering and new technology, Huazhong University of Science and Technology, Wuhan, China
6 shared publicationsZhe Chen
5 shared publications- Marjan Popov
Delft University of Technology, Delft, The Netherlands
4 shared publications
Latest Publications
- 24 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 38 (6) , 3950-3958
Estimating the Harmonic Impacts of Multiple Harmonic-Producing Loads Considering Network Impedance Variations
The existing methods for evaluating harmonic impacts of multiple harmonic-producing loads (HLs) usually assume that all the network impedances are constant in the concerned whole-time interval. While considering the actual situations in power grids, the network impedances may have continuous or sudden variations due to grid operation changes, such as power line maintenance, filter switching, and capacitor switching, which causes the unreliable estimation of harmonic impacts by the existing methods. In view of this shortcoming, a novel multi-point model considering the variations of multiple network impedances is proposed. Furthermore, two weight matrices are formulated to fit the abrupt changes in network impedances. Based on the model and the matrices, the continuous and sudden variations of multiple network impedances can be tracked simultaneously according to the proposed minimum weighted variation constraint. Finally, more realistic and accurate harmonic impacts can be obtained. The performed simulation and experiment have demonstrated the validity of this method.
- 24 July 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 38 (6) , 3950-3958
Estimating the Harmonic Impacts of Multiple Harmonic-Producing Loads Considering Network Impedance Variations
The existing methods for evaluating harmonic impacts of multiple harmonic-producing loads (HLs) usually assume that all the network impedances are constant in the concerned whole-time interval. While considering the actual situations in power grids, the network impedances may have continuous or sudden variations due to grid operation changes, such as power line maintenance, filter switching, and capacitor switching, which causes the unreliable estimation of harmonic impacts by the existing methods. In view of this shortcoming, a novel multi-point model considering the variations of multiple network impedances is proposed. Furthermore, two weight matrices are formulated to fit the abrupt changes in network impedances. Based on the model and the matrices, the continuous and sudden variations of multiple network impedances can be tracked simultaneously according to the proposed minimum weighted variation constraint. Finally, more realistic and accurate harmonic impacts can be obtained. The performed simulation and experiment have demonstrated the validity of this method.
- 19 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 39 (1) , 2093-2105
A Hierarchical Identification Method of Commutation Failure Risk Areas in Multi-Infeed LCC-HVDC Systems
In the multi-infeed LCC-HVDC system, the concurrent commutation failure (CCF) caused by the AC fault of the receiving-end system may lead to the blocking of multiple converter stations, which challenges power grid security and stability. This paper proposes a novel method to quickly and accurately identify the CF risk areas, considering the CF probability (CFP) during the single-line-to-ground (SLG) fault. First, an AC-DC voltage asymmetry factor (ADVAF) and its theoretical derivation are proposed to quantify the influence of the fault position on the CF. Second, the critical ADVAF (CADVAF) is derived based on the equivalent method. By comparing ADVAF and CADVAF, the CF risk areas can be quickly divided into non-, possible- and inevitable-concurrent CF risk areas. Third, the relationship between local CFP (LCFP) and fault position is established, and the concurrent CFP (CCFP) is calculated. The proposed method has improved the accuracy and computational efficiency of theoretical analysis than earlier methods. Finally, the validity and accuracy of the proposed method are verified in dual-infeed and five-infeed LCC-HVDC systems built based on the IEEE 39-bus and IEEE 118-bus models, respectively.
- 19 April 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 39 (1) , 2093-2105
A Hierarchical Identification Method of Commutation Failure Risk Areas in Multi-Infeed LCC-HVDC Systems
In the multi-infeed LCC-HVDC system, the concurrent commutation failure (CCF) caused by the AC fault of the receiving-end system may lead to the blocking of multiple converter stations, which challenges power grid security and stability. This paper proposes a novel method to quickly and accurately identify the CF risk areas, considering the CF probability (CFP) during the single-line-to-ground (SLG) fault. First, an AC-DC voltage asymmetry factor (ADVAF) and its theoretical derivation are proposed to quantify the influence of the fault position on the CF. Second, the critical ADVAF (CADVAF) is derived based on the equivalent method. By comparing ADVAF and CADVAF, the CF risk areas can be quickly divided into non-, possible- and inevitable-concurrent CF risk areas. Third, the relationship between local CFP (LCFP) and fault position is established, and the concurrent CFP (CCFP) is calculated. The proposed method has improved the accuracy and computational efficiency of theoretical analysis than earlier methods. Finally, the validity and accuracy of the proposed method are verified in dual-infeed and five-infeed LCC-HVDC systems built based on the IEEE 39-bus and IEEE 118-bus models, respectively.
- 13 September 2022
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 144, 108622
A novel deep learning–based fault diagnosis algorithm for preventing protection malfunction
- 13 September 2022
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 144, 108622
A novel deep learning–based fault diagnosis algorithm for preventing protection malfunction
- 30 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 38 (1) , 642-654
A Control Method for Converter-Interfaced Sources to Improve Operation of Directional Protection Elements
The traditional fault control strategy of converter-interfaced renewable energy sources (CIRESs) may bring about a lower sensitivity level or misoperation of fault component-based directional elements. To overcome this problem, a new control scheme is proposed to adjust sequence impedance angles of CIRESs by computing suitable current references of the CIRES controller. Meanwhile, these current references are maximized by an iterative algorithm to make full use of the short-circuit capacity of CIRESs. The proposed control scheme is applicable to various faulty conditions such as different fault types, power factors, weak grids, and larger fault resistances. Compared with the new directional elements that need to update protection algorithms, the proposed control strategies can make CIRESs compatible with the existing directional elements whilst the necessary fault ride-through (FRT) requirements can still be satisfied. Furthermore, all the controller parameters are not required to be revised based on the detected fault type, even with only local measured data collected. The associated PSCAD simulations, real-time digital simulator (RTDS) testing and the downscale hardware experiment verify the proposed method.
- 30 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 38 (1) , 642-654
A Control Method for Converter-Interfaced Sources to Improve Operation of Directional Protection Elements
The traditional fault control strategy of converter-interfaced renewable energy sources (CIRESs) may bring about a lower sensitivity level or misoperation of fault component-based directional elements. To overcome this problem, a new control scheme is proposed to adjust sequence impedance angles of CIRESs by computing suitable current references of the CIRES controller. Meanwhile, these current references are maximized by an iterative algorithm to make full use of the short-circuit capacity of CIRESs. The proposed control scheme is applicable to various faulty conditions such as different fault types, power factors, weak grids, and larger fault resistances. Compared with the new directional elements that need to update protection algorithms, the proposed control strategies can make CIRESs compatible with the existing directional elements whilst the necessary fault ride-through (FRT) requirements can still be satisfied. Furthermore, all the controller parameters are not required to be revised based on the detected fault type, even with only local measured data collected. The associated PSCAD simulations, real-time digital simulator (RTDS) testing and the downscale hardware experiment verify the proposed method.
- 28 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 38 (2) , 1094-1110
Enhanced Frequency-Constrained Unit Commitment Considering Variable-Droop Frequency Control From Converter-Based Generator
To improve the frequency stability of power systems with a high penetration of converter-based generators, this paper proposes an Enhanced Frequency-Constrained Unit Commitment (E-FCUC) considering variable-droop-controlled Frequency Control (FC) from converter-based generators. Unlike previous studies emphasizing conventional and fix-droop converter-based generators participating in primary frequency response, the impact of converter-based generators with variable-droop FC schemes is investigated, modeled, and then incorporated into the UC problems. Firstly, the transfer function of variable-droop-controlled converter-based generators is modeled; then the available primary power reserves bounding provided by converter-based generators is derived. Secondly, the frequency dynamic of power systems considering joint frequency control from conventional generators and variable-droop-controlled converter-based generators is derived based on an analytical aggregated System Frequency Response (SFR) model. Since the nonlinear non-smooth nature of frequency dynamic function, the max-affine Piece Wise Linearization (PWL) method is used to fitting the dynamic frequency function. The fitting function is subsequently reformulated into mix-integer linearized constraints participating in UC studies. Case studies based on a modified IEEE 6 bus test system and a modified IEEE 118 bus test system are carried out to verify the effectiveness of the proposed E-FCUC through comparisons of results with existing empirical models.
- 28 April 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 38 (2) , 1094-1110
Enhanced Frequency-Constrained Unit Commitment Considering Variable-Droop Frequency Control From Converter-Based Generator
To improve the frequency stability of power systems with a high penetration of converter-based generators, this paper proposes an Enhanced Frequency-Constrained Unit Commitment (E-FCUC) considering variable-droop-controlled Frequency Control (FC) from converter-based generators. Unlike previous studies emphasizing conventional and fix-droop converter-based generators participating in primary frequency response, the impact of converter-based generators with variable-droop FC schemes is investigated, modeled, and then incorporated into the UC problems. Firstly, the transfer function of variable-droop-controlled converter-based generators is modeled; then the available primary power reserves bounding provided by converter-based generators is derived. Secondly, the frequency dynamic of power systems considering joint frequency control from conventional generators and variable-droop-controlled converter-based generators is derived based on an analytical aggregated System Frequency Response (SFR) model. Since the nonlinear non-smooth nature of frequency dynamic function, the max-affine Piece Wise Linearization (PWL) method is used to fitting the dynamic frequency function. The fitting function is subsequently reformulated into mix-integer linearized constraints participating in UC studies. Case studies based on a modified IEEE 6 bus test system and a modified IEEE 118 bus test system are carried out to verify the effectiveness of the proposed E-FCUC through comparisons of results with existing empirical models.
- Open Access
- 1 April 2022
- Published by Elsevier in Energy Reports
- Vol. 8, 1350-1356
Bayesian inference for short-time risk evaluation considering time-varying contingencies
- 1 April 2022
- Published by Elsevier in Energy Reports
- Vol. 8, 1350-1356
Open AccessBayesian inference for short-time risk evaluation considering time-varying contingencies
- Open Access
- 1 April 2022
- Published by Elsevier in Energy Reports
- Vol. 8, 1302-1312
Intelligent coordinated damping control in active distribution network based on PSO
- 1 April 2022
- Published by Elsevier in Energy Reports
- Vol. 8, 1302-1312
Open AccessIntelligent coordinated damping control in active distribution network based on PSO
- 1 September 2021
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 130, 107009
Protection collaborative fault control for power electronic-based power plants during unbalanced grid faults
- 1 September 2021
- Published by Elsevier in International Journal of Electrical Power & Energy Systems
- Vol. 130, 107009
Protection collaborative fault control for power electronic-based power plants during unbalanced grid faults