EBEnrique Bronchalo

Enrique Bronchalo

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Enrique Bronchalo has a total of 73 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Submersible non-uniform slab rectangular waveguide complex permittivity sensor with practical application in food industry

    by Paula Viudes, Germán Torregrosa-Penalva, Enrique Bronchalo, Héctor García-Martínez, Ilona Piekarz, Jakub Sorocki, Sara Barberá-Boix, Julia Arias-Rodríguez, Ernesto Ávila-Navarro

    This work presents the design and experimental validation of a novel non-uniform rectangular waveguide microwave sensor for liquid characterization in the food industry. The sensor offers a low-cost and easy-to-use solution to characterize complex permittivity, and its design can be customized for specific operating frequencies and material permittivity ranges. The sensing parameters are the group delay and the amplitude of the reflection coefficient. The underlying theory is described and compared with other similar structures. As a proof of concept, the device is designed and optimized to measure relative permittivity values ranging from 1 to 15 with loss tangents up to 0.8, within a 5 to 6 GHz bandwidth, thereby maximizing field matching in this specific range. Its open-channel design facilitates easy measurement by allowing direct immersion of the sensor into a container holding the material under test (MUT). The selected test materials include a variety of oils, honeys, and syrups to experimentally validate the sensor application in foodsensing. Experimental measurements were conducted at various temperatures between 28 and 55 ◦C, and the results were compared against those obtained using a coaxial probe as an alternative characterization method. A key advantage of this sensor is its performance in temperature-dependent measurements compared to the coaxial probe. Finally, the sensor’s characteristics are compared with several state-of-the-art sensors.

  • Open Access

    One-Port Tapered Rectangular Waveguide Microwave Permittivity Sensor

    by Paula Viudes, Germán Torregrosa-Penalva, Enrique Bronchalo, Héctor García-Martínez

    This work presents a novel one-port microwave permittivity sensor. The sensor is formed by a non-uniform longitudinal section rectangular waveguide (RW) and makes use of the group delay of the reflected signal at its input as sensing magnitude. With the proposed sensor it is possible to measure the relative permittivity of low-loss dielectrics filling the waveguide. The theoretical background explaining the behavior of the sensor is given, along with expressions for the sensor sensitivity as a function of its geometrical dimensions. Guidelines are provided for designing the proposed sensor structure depending on the targeted range of material permittivities and the desired sensing frequency bandwidth. In order to verify the correct operation of the suggested sensor scheme, a proof-of-concept tapered RW (TRW) one-port sensor has been fabricated to measure relative permittivities between 3.5 and 6.5, for a frequency span from 4.8 GHz to 5.8 GHz. The implementation includes a microstrip to TRW transition for the determination of the dielectric permittivity of different low-loss materials under test.


  • Open Access

    3-D-Printed Two-Dielectric Rectangular Waveguide TE₁₀–TE₂₀ Mode Converter

    by Germán Torregrosa-Penalva, Benjamin Potelon, Paula Viudes-Pérez, Héctor García-Martínez, Enrique Bronchalo, Ernesto Ávila-Navarro, Cédric Quendo

    In this work a novel TE 10 –TE 20 mode converter for rectangular waveguide (RW) is presented. The proposed structure is conceived as a device that can be inserted in an empty straight section of a RW to yield the desired mode conversion. The converter is formed by a single ‘V’ shaped two-dielectric compact solid that can be scaled according to the frequency of operation and to fit inside the targeted RW section. It is a very low-cost light structure easy to fabricate compared to conventional alternatives of mode converters. To demonstrate the advantages of the proposed design and show its performance, a RW TE 10 –TE 20 mode converter has been designed, simulated and measured at a center frequency of 10.7 GHz in a WR-137. It has been implemented by using additive manufacturing techniques and two materials with different dielectric permittivity. Simulated results show a mode conversion efficiency higher than 85% for a frequency bandwidth between 10.1 GHz and 11.7 GHz, and a mode purity higher than 98% for a frequency range between 9.5 GHz and 11.6 GHz. Back-to-back conversion measurements performed using WR-90 to WR-137 adapters and two of the proposed converter designs, are used to demonstrate the response of the novel TE 10 –TE 20 mode converter. Also, the measurement of the H-plane radiation pattern of a TE 20 fed WR-137 aperture is provided to corroborate the good performance of the proposed mode converter. The comparison between these measurements and electromagnetic simulations are in good agreement and show a band of operation between 10.1 GHz and 11.1 GHz.


  • 3-D -Printed Dielectric Slab Rectangular Waveguide for TE 10 and TE 20 Mode Equalization

    by Germán Torregrosa-Penalva, Héctor García-Martínez, Paula Viudes-Pérez, Enrique Bronchalo, Ernesto Ávila-Navarro, Maurizio Bozzi

    The dielectric slab rectangular waveguide (DSRW) has been widely studied and used for increasing the single-mode bandwidth (BW) of rectangular waveguides. This work presents a DSRW for equalizing the group velocity of the first two propagating modes in the structure. Suitably scaled, this DSRW design can be used in chip-to-chip communications to yield interconnects that avoid dispersion while enhancing the BW density of these systems. A theoretical analysis is introduced to show the equalization BW attained depending on the slab dimensions with regard to the rectangular waveguide width and the dielectric permittivity of the materials that fill the waveguide. A proof of concept slab rectangular waveguide is designed to meet a 45% equalization BW around a center frequency of 10.0 GHz. The design is scalable and can be adapted to fit the dielectric permittivity of available materials. Several waveguide sections were fabricated using additive manufacturing (AM) techniques and two dielectric materials with different permittivities. Simulations and measurements confirm the waveguide behavior at the design frequency range. TE $_{10}$ and TE $_{20}$ modes exhibit the same group velocity of 0.36 $\times$ $c_{0}$ at 7.95 GHz.


  • Open Access

    On the Selectivity of Planar Microwave Glucose Sensors with Multicomponent Solutions

    by Carlos G. Juan, Enrique Bronchalo, Benjamin Potelon, Cédric Quendo, Víctor F. Muñoz, José M. Ferrández-Vicente, José M. Sabater-Navarro

    The development of glucose concentration sensors by means of microwave planar resonant technology is an active field attracting considerable attention from the scientific community. Although showing promising results, the current experimental sensors are facing some fundamental challenges. Among them, the most critical one seems to be the selectivity of glucose concentration against the variations of the concentrations of other components or parameters. In this article, we investigate the selectivity of microwave planar resonant sensors when measuring multicomponent solutions. Three sensors are involved, two of them having been designed looking for a more simplified system with a reduced size, and the third one has been specially developed to improve the sensitivity. The performance of these sensors is thoroughly assessed with a large set of measurements involving multicomponent solutions composed of pure water, NaCl, albumin at different concentrations and glucose at different concentrations. The impact of the simultaneous variations of the concentrations of glucose and albumin on the final measurements is analyzed, and the effective selectivity of the sensors is discussed. The results show a clear influence of the albumin concentration on the measurements of the glucose concentration, thereby pointing to a lack of selectivity for all sensors. This influence has been modeled, and strategies to manage this selectivity challenge are inferred.


  • Study of Qᵤ-Based Resonant Microwave Sensors and Design of 3-D-Printed Devices Dedicated to Glucose Monitoring

    by Carlos G. Juan, Benjamin Potelon, Cedric Quendo, Hector Garcia-Martinez, Ernesto Avila-Navarro, Enrique Bronchalo, Jose M. Sabater-Navarro

    A low-cost, additively manufactured, biocompatible glucose sensor based on the changes in the unloaded quality factor ( $Q_{\mathbf {u}}$ ) with a single split-ring resonator is presented. An exposition of the fundamentals for the use of the $Q_{\mathbf {u}}$ as sensing parameter with microwave planar resonant sensors is shown. The convenience of this sensing parameter is analyzed from the theoretical point of view, and practical design and optimization guidelines are inferred with a special focus on the optimization of $Q_{\mathbf {u}}$ sensitivity to glucose concentration. For practical demonstration and experimental assessment, a novel inverted microstrip configuration is considered, built upon a customized structure made with a certified biocompatible material thanks to 3-D printing techniques, which is aimed to provide for a stronger interaction between the electromagnetic fields and the sample. Two metallization solutions are investigated, yielding devices operating at 4.50 and 4.62 GHz, with operating $Q_{\mathbf {u}}$ of 16.36 and 22.00, relative $Q_{\mathbf {u}}$ sensitivities of 1.377 and 2.727, $Q_{\mathbf {u}}$ sensitivities to glucose content within the physiological range of $0.3\times 10^{-3}$ per mg/dL and $0.6\times 10^{-3}$ per mg/dL, sensing areas of approximately $11.7\times8.8$ mm 2 and total structure sizes of 950.0 $\times 35.0\times3.5$ mm 3 . The devices show good performance with water–glucose solutions covering a wide range of concentrations, involving physiological as well as industry-related ones.


  • Open Access

    Microwave Planar Resonant Solutions for Glucose Concentration Sensing: A Systematic Review

    by Carlos G. Juan, Benjamin Potelon, Cédric Quendo, Enrique Bronchalo

    The measurement of glucose concentration finds interesting potential applications in both industry and biomedical contexts. Among the proposed solutions, the use of microwave planar resonant sensors has led to remarkable scientific activity during the last years. These sensors rely on the changes in the dielectric properties of the medium due to variations in the glucose concentration. These devices show electrical responses dependent on the surrounding dielectric properties, and therefore the changes in their response can be related to variations in the glucose content. This work shows an up-to-date review of this sensing approach after more than one decade of research and development. The attempts involved are sorted by the sensing parameter, and the computation of a common relative sensitivity to glucose is proposed as general comparison tool. The manuscript also discusses the key points of each sensor category and the possible future lines and challenges of the sensing approach.


  • Planar Diplexer Design Using an Energetic Coupling Approach

    by Héctor García-Martínez, David Ramírez-Gil, Germán Torregrosa-Penalva, Ernesto Ávila-Navarro, Enrique Bronchalo, Carolina Blanco-Angulo

    This paper presents a simple procedure to design planar diplexers making use of an energetic coupling approach. The targeted diplexer uses a stepped impedance resonator (SIR) to generate two resonant frequencies at the desired pass bands. The energetic coupling theory is employed to obtain appropriate coupling factors between the SIR and the diplexer outputs. In order to validate the proposed design method two diplexers satisfying the GSM and WLAN application frequencies have been fabricated and characterized. One prototype has been implemented in microstrip technology, while for the fabrication of the other one a low-cost 3D printing multilayer process has been used. In both cases measurements are in good agreement with simulated responses.


  • Multilayered additive-manufactured half-wavelength coupled line filters

    by Héctor García-Martínez, Ernesto Ávila-Navarro, Germán Torregrosa-Penalva, Enrique Bronchalo, Carolina Blanco-Angulo, Maurizio Bozzi