Sirisha Senthil
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sirisha Senthil has a total of 235 co-authors. Here are the top co-authors by number of shared publications:
Chandrasekhar Garudadri
VST Center for Glaucoma, L V Prasad Eye Institute, Hyderabad, India
15 shared publicationsNikhil Choudhari
Glaucoma Department, VST Center for Glaucoma Care, L V Prasad Eye Institute, Banjara Hills, India
11 shared publicationsAnil K. Mandal
Centre for Sight, Banjara Hills, Hyderabad, India
8 shared publicationsKiranmaye Turaga
L.V. Prasad Eye Institute, GMR Varalakshmi Campus, Visakhapatnam, India
8 shared publicationsRaghava Chary
Department of Glaucoma, VST Glaucoma Centre, Dr. Kallam Anji Reddy Campus, L V Prasad Eye Institute, Banjara Hills, Hyderabad, Telangana, India
8 shared publications- Rashmi Krishnamurthy
LV Prasad Eye Institute
8 shared publications
Latest Publications
- 11 November 2026
- Published by BMJ in BMJ Case Reports
- Vol. 19 (11) , e275844
Congenital glaucoma as the presenting ophthalmic manifestation of Aicardi-Goutières syndrome type 1 (TREX1 mutation): a diagnostic and management challenge
- 11 November 2026
- Published by BMJ in BMJ Case Reports
- Vol. 19 (11) , e275844
Congenital glaucoma as the presenting ophthalmic manifestation of Aicardi-Goutières syndrome type 1 (TREX1 mutation): a diagnostic and management challenge
- Open Access
- 29 September 2026
- Published by Wolters Kluwer Health in Indian Journal Of Ophthalmology
- Vol. 74 (10) , 1525-1530
Visual field loss in Sturge–Weber syndrome and phakomatosis pigmentovascularis: Implications for glaucoma assessment
Objectives: To evaluate the patterns of visual field (VF) defects in patients with Sturge–Weber syndrome (SWS) and phakomatosis pigmentovascularis (PPV) using standard automated perimetry. Methods: This retrospective study analyzed the clinical and VF data of patients with SWS or PPV undergoing treatment for glaucoma and had VF test data over a 27-year period. VF defects were classified as glaucomatous, neurological, combined, or unclassifiable. Statistical analyses were performed to determine factors associated with type of field defects. Results: A total of 86 patients (172 eyes) were included, with 62 (72%) having SWS and 24 (28%) PPV. Glaucoma was present in 49.2% of SWS eyes and 91.6% of PPV eyes. Reliable VF tests were more common in SWS than in PPV ( P < 0.001). Glaucomatous defects were observed in 35.5% of eyes, 7.7% had neurological defects, and 4.1% had combined defects. Advanced field loss was the most common glaucomatous defect (54%). Eyes treated with external beam radiotherapy for diffuse choroidal hemangioma developed localized field defects mimicking glaucoma and homonymous hemianopia. Conclusions: Glaucoma remains the primary cause of VF loss in SWS and PPV, with a significant proportion of patients demonstrating advanced glaucomatous damage. Accurate interpretation of VF results is crucial for differentiating glaucomatous progression from other ocular and neurological causes in these rare phakomatoses.
- 29 September 2026
- Published by Wolters Kluwer Health in Indian Journal Of Ophthalmology
- Vol. 74 (10) , 1525-1530
Open AccessVisual field loss in Sturge–Weber syndrome and phakomatosis pigmentovascularis: Implications for glaucoma assessment
Objectives: To evaluate the patterns of visual field (VF) defects in patients with Sturge–Weber syndrome (SWS) and phakomatosis pigmentovascularis (PPV) using standard automated perimetry. Methods: This retrospective study analyzed the clinical and VF data of patients with SWS or PPV undergoing treatment for glaucoma and had VF test data over a 27-year period. VF defects were classified as glaucomatous, neurological, combined, or unclassifiable. Statistical analyses were performed to determine factors associated with type of field defects. Results: A total of 86 patients (172 eyes) were included, with 62 (72%) having SWS and 24 (28%) PPV. Glaucoma was present in 49.2% of SWS eyes and 91.6% of PPV eyes. Reliable VF tests were more common in SWS than in PPV ( P < 0.001). Glaucomatous defects were observed in 35.5% of eyes, 7.7% had neurological defects, and 4.1% had combined defects. Advanced field loss was the most common glaucomatous defect (54%). Eyes treated with external beam radiotherapy for diffuse choroidal hemangioma developed localized field defects mimicking glaucoma and homonymous hemianopia. Conclusions: Glaucoma remains the primary cause of VF loss in SWS and PPV, with a significant proportion of patients demonstrating advanced glaucomatous damage. Accurate interpretation of VF results is crucial for differentiating glaucomatous progression from other ocular and neurological causes in these rare phakomatoses.
- 15 June 2026
- Published by BMJ in BMJ Case Reports
- Vol. 19 (6) , e270525
Rho-kinase inhibitors predisposing to secondary keratitis
- 15 June 2026
- Published by BMJ in BMJ Case Reports
- Vol. 19 (6) , e270525
Rho-kinase inhibitors predisposing to secondary keratitis
- 5 February 2026
- Published by Elsevier in Journal of American Association for Pediatric Ophthalmology and Strabismus
- Vol. 30 (1) , 104755
Offline AI-assisted fundus imaging for preliminary screening of childhood glaucoma
- 5 February 2026
- Published by Elsevier in Journal of American Association for Pediatric Ophthalmology and Strabismus
- Vol. 30 (1) , 104755
Offline AI-assisted fundus imaging for preliminary screening of childhood glaucoma
- 9 December 2025
- Published by Elsevier in Ophthalmology Glaucoma
- Vol. 9 (3) , 343-352
Phacomatosis Pigmentovascularis and Sturge-Weber Syndrome
- 9 December 2025
- Published by Elsevier in Ophthalmology Glaucoma
- Vol. 9 (3) , 343-352
Phacomatosis Pigmentovascularis and Sturge-Weber Syndrome
- Open Access
- 24 November 2025
- Published by Wolters Kluwer Health in Indian Journal Of Ophthalmology
- Vol. 73 (12) , 1786-1791
Concordance between the new modular slit-lamp mounted Goldmann applanation tonometer (GAT), conventional slit-lamp mounted GAT, and Perkins tonometer
Purpose: To evaluate a new device, the Goldmann applanation tonometer (GAT) mounted on a novel handheld 3D-printed modular slit lamp (MSL), and compare it with the gold standard slit-lamp-mounted GAT and the handheld Perkins tonometer. Methods: One hundred eyes from 100 participants were included in this cross-sectional observational study. The MSL mount was customized for the selected tonometer (Model AT030, Carl Zeiss, India). A Samsung Galaxy S2 mobile phone was used for observing mires and photography during tonometry. One observer measured intraocular pressure (IOP) with slit-lamp GAT, and another observer measured with MSL GAT and Perkins tonometers. The tonometry sequence was slit-lamp GAT, MSL GAT, and Perkins tonometer, with a 5-minute interval between readings. Results: The median age of participants was 56 years (range: 16–83). The median IOP by slit-lamp GAT was 15 mmHg (range: 9–41). Tonometers were compared in pairs: slit-lamp GAT and Perkins, slit-lamp GAT and MSL GAT, and Perkins and MSL GAT. The pairwise Spearman rank correlations were 0.988, 0.988, and 0.983 (all P < 0.001). The mean differences in IOP (95% limits of agreement) were 0.5 (-0.6 to 1.6), 1.2 (0 to 2.4), and 0.7 (-0.7 to 2.1) mmHg, respectively. Conclusion: The MSL-mounted GAT provides reliable IOP readings with minor underestimation (within 2 mmHg in 88% of cases), suggesting its potential utility in clinical practice as a portable slit lamp and anterior segment imaging device.
- 24 November 2025
- Published by Wolters Kluwer Health in Indian Journal Of Ophthalmology
- Vol. 73 (12) , 1786-1791
Open AccessConcordance between the new modular slit-lamp mounted Goldmann applanation tonometer (GAT), conventional slit-lamp mounted GAT, and Perkins tonometer
Purpose: To evaluate a new device, the Goldmann applanation tonometer (GAT) mounted on a novel handheld 3D-printed modular slit lamp (MSL), and compare it with the gold standard slit-lamp-mounted GAT and the handheld Perkins tonometer. Methods: One hundred eyes from 100 participants were included in this cross-sectional observational study. The MSL mount was customized for the selected tonometer (Model AT030, Carl Zeiss, India). A Samsung Galaxy S2 mobile phone was used for observing mires and photography during tonometry. One observer measured intraocular pressure (IOP) with slit-lamp GAT, and another observer measured with MSL GAT and Perkins tonometers. The tonometry sequence was slit-lamp GAT, MSL GAT, and Perkins tonometer, with a 5-minute interval between readings. Results: The median age of participants was 56 years (range: 16–83). The median IOP by slit-lamp GAT was 15 mmHg (range: 9–41). Tonometers were compared in pairs: slit-lamp GAT and Perkins, slit-lamp GAT and MSL GAT, and Perkins and MSL GAT. The pairwise Spearman rank correlations were 0.988, 0.988, and 0.983 (all P < 0.001). The mean differences in IOP (95% limits of agreement) were 0.5 (-0.6 to 1.6), 1.2 (0 to 2.4), and 0.7 (-0.7 to 2.1) mmHg, respectively. Conclusion: The MSL-mounted GAT provides reliable IOP readings with minor underestimation (within 2 mmHg in 88% of cases), suggesting its potential utility in clinical practice as a portable slit lamp and anterior segment imaging device.
- Open Access
- 24 November 2025
- Published by Wolters Kluwer Health in Indian Journal Of Ophthalmology
- Vol. 73 (12) , 1859-1860
“Priming” Aids to Detect the Possible Dysfunction of the Ahmed Glaucoma Valve Devices
Background: Simple priming of the implant is always suggested before Ahmed glaucoma valve (AGV) device implantation. This helps the two valve leaflets to get separated, which aids in smooth jet outflow of fluid from the tube outlet of AGV implant and is initiated only after the priming. Purpose: To detect the anterior fluid leak and possible dysfunction of the AGV implant by the simple priming procedure. Synopsis: Standard priming of the implant was carried out with a 5 cc syringe using a 27-gauge cannula under the operating microscope; normally, jet flow of fluid at the valve outlet indicates implant was in good condition and can be implanted. But in this video, partial flow at the valve outlet and reflux of fluid was noted anteriorly at the tube valve junction, after a few seconds of initial priming, which suggests defection in the AGV implant. Highlights: Intraoperatively, in our experience, over almost 20 years, we have found three faulty devices. The first and only one postoperative experience we had was with the child with acute proptosis at 5 weeks post implant. [1] This video highlights the importance of the simple priming procedure that should be done under a surgical microscope with cautious observation in identifying any dysfunction in the AGV devices. Video Link: https://youtu.be/cr1sBo03jiM
- 24 November 2025
- Published by Wolters Kluwer Health in Indian Journal Of Ophthalmology
- Vol. 73 (12) , 1859-1860
Open Access“Priming” Aids to Detect the Possible Dysfunction of the Ahmed Glaucoma Valve Devices
Background: Simple priming of the implant is always suggested before Ahmed glaucoma valve (AGV) device implantation. This helps the two valve leaflets to get separated, which aids in smooth jet outflow of fluid from the tube outlet of AGV implant and is initiated only after the priming. Purpose: To detect the anterior fluid leak and possible dysfunction of the AGV implant by the simple priming procedure. Synopsis: Standard priming of the implant was carried out with a 5 cc syringe using a 27-gauge cannula under the operating microscope; normally, jet flow of fluid at the valve outlet indicates implant was in good condition and can be implanted. But in this video, partial flow at the valve outlet and reflux of fluid was noted anteriorly at the tube valve junction, after a few seconds of initial priming, which suggests defection in the AGV implant. Highlights: Intraoperatively, in our experience, over almost 20 years, we have found three faulty devices. The first and only one postoperative experience we had was with the child with acute proptosis at 5 weeks post implant. [1] This video highlights the importance of the simple priming procedure that should be done under a surgical microscope with cautious observation in identifying any dysfunction in the AGV devices. Video Link: https://youtu.be/cr1sBo03jiM
- 20 November 2025
- Published by Springer Nature
- p. 397-408
Fundus Image Classification—A Comparison of GAN-Based Image Augmentation Techniques
- 20 November 2025
- Published by Springer Nature
- p. 397-408
Fundus Image Classification—A Comparison of GAN-Based Image Augmentation Techniques
- Open Access
- 26 June 2025
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 20 (6) , e0324883
Evaluating real-world performance of an automated offline glaucoma AI on a smartphone fundus camera across glaucoma severity stages
Purpose: Leveraging an artificial intelligence system (AI) for glaucoma screening can mitigate the current challenges and provide prompt detection and management crucial in averting irreversible blindness. The study reports the real-world performance of a glaucoma AI system deployed on a smartphone-based fundus camera across various severities of glaucoma. Methods: In this prospective comparative study at a tertiary care glaucoma clinic, consecutive patients were evaluated by a glaucoma specialist using clinical assessment, visual field tests, and SD-OCT, and categorized as definite glaucoma, glaucoma suspect, or no glaucoma. For glaucoma patients, severity was determined using Hoddap-Parrish-Anderson criteria based on visual field mean deviation (MD). A disc-centered image per eye was captured using a validated portable non-mydriatic fundus camera. The AI tool’s ability to detect referral-warranted glaucoma (glaucoma and glaucoma suspects) versus no glaucoma was compared to the specialist’s diagnosis. Results: We included 213 participants with a mean age of 55 ± 14.7 years (18, 88). The glaucoma specialist diagnosed 129 subjects as definite glaucoma (early-23, moderate-31, severe-75), 33-disc suspects and 51 as no-glaucoma. The automated AI system based on fundus images achieved an overall diagnostic accuracy of 92.02%, sensitivity of 91.36% (95%CI 85.93% to 95.19%) and specificity of 94.12% (83.76% to 98.77%) for referral warranted glaucoma. The 14 false negatives included 5-disc suspects and 9 definite glaucoma (3-early, 3-moderate and 3-advanced glaucoma). The sensitivity of AI for detecting early, moderate and advanced glaucoma was 86.9% (95%CI 66.4–97.2), 90.3% (95%CI 74.3–97.96), and 96% (88.75% to 99.17%) respectively. Conclusion: In a real-world setting, the AI-based offline tool integrated on a smartphone fundus camera showed a promising performance in detecting referral-warranted glaucoma compared to a glaucoma specialist’s diagnosis. The AI showed higher accuracy in detecting advanced glaucoma followed by moderate and early glaucoma.
- 26 June 2025
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 20 (6) , e0324883
Open AccessEvaluating real-world performance of an automated offline glaucoma AI on a smartphone fundus camera across glaucoma severity stages
Purpose: Leveraging an artificial intelligence system (AI) for glaucoma screening can mitigate the current challenges and provide prompt detection and management crucial in averting irreversible blindness. The study reports the real-world performance of a glaucoma AI system deployed on a smartphone-based fundus camera across various severities of glaucoma. Methods: In this prospective comparative study at a tertiary care glaucoma clinic, consecutive patients were evaluated by a glaucoma specialist using clinical assessment, visual field tests, and SD-OCT, and categorized as definite glaucoma, glaucoma suspect, or no glaucoma. For glaucoma patients, severity was determined using Hoddap-Parrish-Anderson criteria based on visual field mean deviation (MD). A disc-centered image per eye was captured using a validated portable non-mydriatic fundus camera. The AI tool’s ability to detect referral-warranted glaucoma (glaucoma and glaucoma suspects) versus no glaucoma was compared to the specialist’s diagnosis. Results: We included 213 participants with a mean age of 55 ± 14.7 years (18, 88). The glaucoma specialist diagnosed 129 subjects as definite glaucoma (early-23, moderate-31, severe-75), 33-disc suspects and 51 as no-glaucoma. The automated AI system based on fundus images achieved an overall diagnostic accuracy of 92.02%, sensitivity of 91.36% (95%CI 85.93% to 95.19%) and specificity of 94.12% (83.76% to 98.77%) for referral warranted glaucoma. The 14 false negatives included 5-disc suspects and 9 definite glaucoma (3-early, 3-moderate and 3-advanced glaucoma). The sensitivity of AI for detecting early, moderate and advanced glaucoma was 86.9% (95%CI 66.4–97.2), 90.3% (95%CI 74.3–97.96), and 96% (88.75% to 99.17%) respectively. Conclusion: In a real-world setting, the AI-based offline tool integrated on a smartphone fundus camera showed a promising performance in detecting referral-warranted glaucoma compared to a glaucoma specialist’s diagnosis. The AI showed higher accuracy in detecting advanced glaucoma followed by moderate and early glaucoma.
- 6 June 2025
- Published by Wolters Kluwer Health in Cornea
- Vol. 44 (8) , e19-e20
Reply