Seong-Joo Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Seong-Joo Lee has a total of 102 co-authors. Here are the top co-authors by number of shared publications:
- Kiwoong Kim
Korea Research Institute of Standards and Science
22 shared publications Kwon Kyu Yu
Center for Superconducting Quantum Computer System
14 shared publicationsSeong-Min Hwang
Quantum Magnetic Sensing Group
12 shared publicationsJeong Hyun Shim
Quantum Magnetic Imaging Team, Korea Research Institute of Standards and Science 1 , Daejeon 34113, South Korea
10 shared publications- Jeong Hyun Shim
Korea Research Institute of Standards and Science
9 shared publications - Seong-Min Hwang
National Creative Research Initiative Center for Neuro-Dynamics and Department of Physics, Korea University, Seoul 136-701, Korea
7 shared publications
Latest Publications
- Open Access
- 12 August 2025
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 10 (33) , 37611-37616
Zero-Field Overhauser Dynamic Nuclear Polarization
Overhauser dynamic nuclear polarization (O-DNP) enables the production of hyperpolarization in liquids via the dissolution of nitroxide radicals. However, the application of magnetic fields has been inevitable. In the present study, we experimentally demonstrate that water can be hyperpolarized through O-DNP at effectively zero magnetic field. Selective saturation induced by circularly polarized RF fields, generated by two orthogonal RF coils, effectively circumvents the concurrence of positive and negative polarizations that would otherwise significantly deteriorate O-DNP efficiency. Through electron-to-nuclear spectral mapping, the electron paramagnetic resonance spectrum of the nitroxide radical was recorded at a magnetic field of 2 nT. A direct comparison revealed that O-DNP with circularly polarized RF is more than 103 times as efficient as that with linearly polarized RF. Finally, at a near-zero field, Overhauser-enhanced 1H nuclear magnetic resonance from water was observed without the need for auxiliary aids such as sample shuttling or field cycling.
- 12 August 2025
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 10 (33) , 37611-37616
Open AccessZero-Field Overhauser Dynamic Nuclear Polarization
Overhauser dynamic nuclear polarization (O-DNP) enables the production of hyperpolarization in liquids via the dissolution of nitroxide radicals. However, the application of magnetic fields has been inevitable. In the present study, we experimentally demonstrate that water can be hyperpolarized through O-DNP at effectively zero magnetic field. Selective saturation induced by circularly polarized RF fields, generated by two orthogonal RF coils, effectively circumvents the concurrence of positive and negative polarizations that would otherwise significantly deteriorate O-DNP efficiency. Through electron-to-nuclear spectral mapping, the electron paramagnetic resonance spectrum of the nitroxide radical was recorded at a magnetic field of 2 nT. A direct comparison revealed that O-DNP with circularly polarized RF is more than 103 times as efficient as that with linearly polarized RF. Finally, at a near-zero field, Overhauser-enhanced 1H nuclear magnetic resonance from water was observed without the need for auxiliary aids such as sample shuttling or field cycling.
- 25 October 2023
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 15 (44) , 51593-51605
Dual-Emissive Mn-Doped Lead Halide Perovskite Nanocrystals as Background-Suppressed Latent Fingerprint Detection Probes
Diverse strategies have been developed to visualize latent fingerprints (LFPs) that are undetectable by the naked eye. Among them, fluorescence-based approaches have emerged as an attractive method for enabling high-resolution LFP imaging. However, the use of fluorescent probes for LFP detection remains challenging due to cumbersome processing, low selectivity, and high background interference. Here, we demonstrate highly efficient, sensitive, and background-free LFP detection with dual-color emission arising from manganese (Mn)-doped lead halide perovskite (CsPb(Cl1-yBry)3) nanocrystals (NCs). The resulting bright, fluorescent, solid-state nanopowder (NP) permits the visualization of LFP ridge structures and the resolution of level 1-3 LFP features. The dual-color emission of the Mn-doped perovskite NP provides a simple, robust, and effective route to overcome background interference, thereby increasing the resolution and sensitivity of the LFP detection. The combination of the high quantum efficiency and dual emission of Mn-doped perovskite NP offers great potential for forensic science.
- 25 October 2023
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 15 (44) , 51593-51605
Dual-Emissive Mn-Doped Lead Halide Perovskite Nanocrystals as Background-Suppressed Latent Fingerprint Detection Probes
Diverse strategies have been developed to visualize latent fingerprints (LFPs) that are undetectable by the naked eye. Among them, fluorescence-based approaches have emerged as an attractive method for enabling high-resolution LFP imaging. However, the use of fluorescent probes for LFP detection remains challenging due to cumbersome processing, low selectivity, and high background interference. Here, we demonstrate highly efficient, sensitive, and background-free LFP detection with dual-color emission arising from manganese (Mn)-doped lead halide perovskite (CsPb(Cl1-yBry)3) nanocrystals (NCs). The resulting bright, fluorescent, solid-state nanopowder (NP) permits the visualization of LFP ridge structures and the resolution of level 1-3 LFP features. The dual-color emission of the Mn-doped perovskite NP provides a simple, robust, and effective route to overcome background interference, thereby increasing the resolution and sensitivity of the LFP detection. The combination of the high quantum efficiency and dual emission of Mn-doped perovskite NP offers great potential for forensic science.
- Open Access
- 29 September 2023
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 8 (40) , 37302-37308
Chemical Analysis of an Isotopically Labeled Molecule Using Two-Dimensional NMR Spectroscopy at 34 μT
Low-field nuclear magnetic resonance (NMR) spectroscopy, conducted at or below a few millitesla, provides only limited spectral information due to its inability to resolve chemical shifts. Thus, chemical analysis based on this technique remains challenging. One potential solution to overcome this limitation is the use of isotopically labeled molecules. However, such compounds, particularly their use in two-dimensional (2D) NMR techniques, have rarely been studied. This study presents the results of both experimental and simulated correlation spectroscopy (COSY) on 1-13C-ethanol at 34.38 μT. The strong heteronuclear coupling in this molecule breaks the magnetic equivalence, causing all J-couplings, including homonuclear coupling, to split the 1H spectrum. The obtained COSY spectrum clearly shows the spectral details. Furthermore, we observed that homonuclear coupling between 1H spins generated cross-peaks only when the associated 1H spins were coupled to identical 13C spin states. Our findings demonstrate that a low-field 2D spectrum, even with a moderate spectral line width, can reveal the J-coupling networks of isotopically labeled molecules.
- 29 September 2023
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 8 (40) , 37302-37308
Open AccessChemical Analysis of an Isotopically Labeled Molecule Using Two-Dimensional NMR Spectroscopy at 34 μT
Low-field nuclear magnetic resonance (NMR) spectroscopy, conducted at or below a few millitesla, provides only limited spectral information due to its inability to resolve chemical shifts. Thus, chemical analysis based on this technique remains challenging. One potential solution to overcome this limitation is the use of isotopically labeled molecules. However, such compounds, particularly their use in two-dimensional (2D) NMR techniques, have rarely been studied. This study presents the results of both experimental and simulated correlation spectroscopy (COSY) on 1-13C-ethanol at 34.38 μT. The strong heteronuclear coupling in this molecule breaks the magnetic equivalence, causing all J-couplings, including homonuclear coupling, to split the 1H spectrum. The obtained COSY spectrum clearly shows the spectral details. Furthermore, we observed that homonuclear coupling between 1H spins generated cross-peaks only when the associated 1H spins were coupled to identical 13C spin states. Our findings demonstrate that a low-field 2D spectrum, even with a moderate spectral line width, can reveal the J-coupling networks of isotopically labeled molecules.
- Open Access
Frequency Limits of Sequential Readout for Sensing AC Magnetic Fields Using Nitrogen-Vacancy Centers in Diamond
The nitrogen-vacancy (NV) centers in diamond have the ability to sense alternating-current (AC) magnetic fields with high spatial resolution. However, the frequency range of AC sensing protocols based on dynamical decoupling (DD) sequences has not been thoroughly explored experimentally. In this work, we aimed to determine the sensitivity of the ac magnetic field as a function of frequency using the sequential readout method. The upper limit at high frequency is clearly determined by Rabi frequency, in line with the expected effect of finite DD-pulse width. In contrast, the lower frequency limit is primarily governed by the duration of optical repolarization rather than the decoherence time (T) of NV spins. This becomes particularly crucial when the repetition (dwell) time of the sequential readout is fixed to maintain the acquisition bandwidth. The equation we provide successfully describes the tendency in the frequency dependence. In addition, at the near-optimal frequency of 1 MHz, we reached a maximum sensitivity of 229 pT/ by employing the XY4-(4) DD sequence.Open AccessFrequency Limits of Sequential Readout for Sensing AC Magnetic Fields Using Nitrogen-Vacancy Centers in Diamond
The nitrogen-vacancy (NV) centers in diamond have the ability to sense alternating-current (AC) magnetic fields with high spatial resolution. However, the frequency range of AC sensing protocols based on dynamical decoupling (DD) sequences has not been thoroughly explored experimentally. In this work, we aimed to determine the sensitivity of the ac magnetic field as a function of frequency using the sequential readout method. The upper limit at high frequency is clearly determined by Rabi frequency, in line with the expected effect of finite DD-pulse width. In contrast, the lower frequency limit is primarily governed by the duration of optical repolarization rather than the decoherence time (T) of NV spins. This becomes particularly crucial when the repetition (dwell) time of the sequential readout is fixed to maintain the acquisition bandwidth. The equation we provide successfully describes the tendency in the frequency dependence. In addition, at the near-optimal frequency of 1 MHz, we reached a maximum sensitivity of 229 pT/ by employing the XY4-(4) DD sequence. - Open Access
- 23 May 2023
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 133 (20)
Quantum diamond microscopy with optimized magnetic field sensitivity and sub-ms temporal resolution
Quantum diamond magnetometers using lock-in detection have successfully detected weak bio-magnetic fields from neurons, a live mammalian muscle, and a live mouse heart. This opens up the possibility of quantum diamond magnetometers visualizing microscopic distributions of the bio-magnetic fields. Here, we demonstrate a lock-in-based widefield quantum diamond microscopy, achieving a mean volume-normalized per-pixel sensitivity of 43.9 nTμm1.5/Hz0.5. We optimize the sensitivity by implementing a double resonance with hyperfine driving and magnetic field alignment along the ⟨001⟩ orientation of the diamond. Additionally, we show that sub-ms temporal resolution (∼0.4 ms) can be achieved while keeping the per-pixel sensitivity at a few tens of nanotesla per second using quantum diamond microscopy. This lock-in-based diamond quantum microscopy could be a step forward in mapping functional activity in neuronal networks in micrometer spatial resolution.
- 23 May 2023
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 133 (20)
Open AccessQuantum diamond microscopy with optimized magnetic field sensitivity and sub-ms temporal resolution
Quantum diamond magnetometers using lock-in detection have successfully detected weak bio-magnetic fields from neurons, a live mammalian muscle, and a live mouse heart. This opens up the possibility of quantum diamond magnetometers visualizing microscopic distributions of the bio-magnetic fields. Here, we demonstrate a lock-in-based widefield quantum diamond microscopy, achieving a mean volume-normalized per-pixel sensitivity of 43.9 nTμm1.5/Hz0.5. We optimize the sensitivity by implementing a double resonance with hyperfine driving and magnetic field alignment along the ⟨001⟩ orientation of the diamond. Additionally, we show that sub-ms temporal resolution (∼0.4 ms) can be achieved while keeping the per-pixel sensitivity at a few tens of nanotesla per second using quantum diamond microscopy. This lock-in-based diamond quantum microscopy could be a step forward in mapping functional activity in neuronal networks in micrometer spatial resolution.
- 30 June 2021
- Published by Korean Open Association for Early Childhood Education in The Journal of Korea Open Association for Early Childhood Education
- Vol. 26 (3) , 115-143
Case-based learning(CBL) model design and its application in early childhood education to enhance teachers’ responsive interactions
본 연구의 목적은 교사의 반응성 상호작용을 증진할 수 있는 사례기반학습을 설계하고 유아교사를 대상으로 교육을 실시하여 그 효과를 검증하는 것이다. 연구 목적을 달성하기 위해 문헌분석, 사례수집 및 범주화, 교사 심층면담, 전문가 검토 등을 통해 사례기반학습을 설계하고, 유아교사를 대상으로 사례기반학습을 적용한 교육을 실시하였다. 또한, 유아교사의 반응성 상호작용을 관찰하고, 대비분석을 통해 사례기반 학습의 효과를 검증하였다. 연구결과, 첫째, 사례기반학습은 교수학습 단계 선정, 교수학습 전략 선정, 놀이 사례 시나리오 선정, 사례분석 준거 도출, 예비 연구, 최종설계안 도출의 6단계 과정을 거쳐 설계되었다. 둘째, 사례기반학습은 유아교사의 반응성 상호작용에 긍정적인 영향을 주는 것으로 나타났다. 본 연구는 유아교사의 실천적 지식 향상을 위한 지원 방안으로 사례기반학습의 현장 적용 가능성을 제고하고, 유아 중심의 교실을 만드는데 필요한 전략 수립을 위한 기초자료를 제공할 수 있을 것이다.
- 30 June 2021
- Published by Korean Open Association for Early Childhood Education in The Journal of Korea Open Association for Early Childhood Education
- Vol. 26 (3) , 115-143
Case-based learning(CBL) model design and its application in early childhood education to enhance teachers’ responsive interactions
본 연구의 목적은 교사의 반응성 상호작용을 증진할 수 있는 사례기반학습을 설계하고 유아교사를 대상으로 교육을 실시하여 그 효과를 검증하는 것이다. 연구 목적을 달성하기 위해 문헌분석, 사례수집 및 범주화, 교사 심층면담, 전문가 검토 등을 통해 사례기반학습을 설계하고, 유아교사를 대상으로 사례기반학습을 적용한 교육을 실시하였다. 또한, 유아교사의 반응성 상호작용을 관찰하고, 대비분석을 통해 사례기반 학습의 효과를 검증하였다. 연구결과, 첫째, 사례기반학습은 교수학습 단계 선정, 교수학습 전략 선정, 놀이 사례 시나리오 선정, 사례분석 준거 도출, 예비 연구, 최종설계안 도출의 6단계 과정을 거쳐 설계되었다. 둘째, 사례기반학습은 유아교사의 반응성 상호작용에 긍정적인 영향을 주는 것으로 나타났다. 본 연구는 유아교사의 실천적 지식 향상을 위한 지원 방안으로 사례기반학습의 현장 적용 가능성을 제고하고, 유아 중심의 교실을 만드는데 필요한 전략 수립을 위한 기초자료를 제공할 수 있을 것이다.
- Open Access
- 27 August 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-8
SQUID-based ultralow-field MRI of a hyperpolarized material using signal amplification by reversible exchange
The signal amplification by reversible exchange (SABRE) technique is a very promising method for increasing magnetic resonance (MR) signals. SABRE can play a particularly large role in studies with a low or ultralow magnetic field because they suffer from a low signal-to-noise ratio. In this work, we conducted real-time superconducting quantum interference device (SQUID)-based nuclear magnetic resonance (NMR)/magnetic resonance imaging (MRI) studies in a microtesla-range magnetic field using the SABRE technique after designing a bubble-separated phantom. A maximum enhancement of 2658 for 1H was obtained for pyridine in the SABRE-NMR experiment. A clear SABRE-enhanced MR image of the bubble-separated phantom, in which the para-hydrogen gas was bubbling at only the margin, was successfully obtained at 34.3 μT. The results show that SABRE can be successfully incorporated into an ultralow-field MRI system, which enables new SQUID-based MRI applications. SABRE can shorten the MRI operation time by more than 6 orders of magnitude and establish a firm basis for future low-field MRI applications.
- 27 August 2019
- Published by Springer Nature in Scientific Reports
- Vol. 9 (1) , 1-8
Open AccessSQUID-based ultralow-field MRI of a hyperpolarized material using signal amplification by reversible exchange
The signal amplification by reversible exchange (SABRE) technique is a very promising method for increasing magnetic resonance (MR) signals. SABRE can play a particularly large role in studies with a low or ultralow magnetic field because they suffer from a low signal-to-noise ratio. In this work, we conducted real-time superconducting quantum interference device (SQUID)-based nuclear magnetic resonance (NMR)/magnetic resonance imaging (MRI) studies in a microtesla-range magnetic field using the SABRE technique after designing a bubble-separated phantom. A maximum enhancement of 2658 for 1H was obtained for pyridine in the SABRE-NMR experiment. A clear SABRE-enhanced MR image of the bubble-separated phantom, in which the para-hydrogen gas was bubbling at only the margin, was successfully obtained at 34.3 μT. The results show that SABRE can be successfully incorporated into an ultralow-field MRI system, which enables new SQUID-based MRI applications. SABRE can shorten the MRI operation time by more than 6 orders of magnitude and establish a firm basis for future low-field MRI applications.
- 1 August 2019
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 305, 138-145
Dynamic nuclear polarisation of liquids at one microtesla using circularly polarised RF with application to millimetre resolution MRI
- 1 August 2019
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 305, 138-145
Dynamic nuclear polarisation of liquids at one microtesla using circularly polarised RF with application to millimetre resolution MRI
- 23 July 2019
- Published by IOP Publishing in Metrologia
- Vol. 56 (4) , 045011
Overhauser proton spin-echo magnetometer for magnetic fields below 1 μ T
Overhauser dynamic nuclear polarization (O-DNP) can significantly boost the intensity of the nuclear magnetic resonance (NMR) signal in comparison to the thermal magnetization for field strengths in the microtesla range. We demonstrate the development and use of an Overhauser spin-echo magnetometer using a superconducting quantum interference device-based microtesla NMR system and dissolved nitroxide radicals in deoxygenated tetramethylsilane liquid. A spin-echo train with an enhanced signal was successfully obtained with the O-DNP technique. A magnetic field strength of about 0.92 T was measured with an uncertainty of 0.7 pT in the presence of a field gradient of 0.038 T cm −1 . The Overhauser proton spin-echo magnetometer will be useful for the measurement of low magnetic fields by minimizing the generation of disturbing magnetic fields without the need to compensate for residual field gradients.
- 23 July 2019
- Published by IOP Publishing in Metrologia
- Vol. 56 (4) , 045011
Overhauser proton spin-echo magnetometer for magnetic fields below 1 μ T
Overhauser dynamic nuclear polarization (O-DNP) can significantly boost the intensity of the nuclear magnetic resonance (NMR) signal in comparison to the thermal magnetization for field strengths in the microtesla range. We demonstrate the development and use of an Overhauser spin-echo magnetometer using a superconducting quantum interference device-based microtesla NMR system and dissolved nitroxide radicals in deoxygenated tetramethylsilane liquid. A spin-echo train with an enhanced signal was successfully obtained with the O-DNP technique. A magnetic field strength of about 0.92 T was measured with an uncertainty of 0.7 pT in the presence of a field gradient of 0.038 T cm −1 . The Overhauser proton spin-echo magnetometer will be useful for the measurement of low magnetic fields by minimizing the generation of disturbing magnetic fields without the need to compensate for residual field gradients.
- Open Access
- 1 March 2019
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 300, 149-152
In-situ Overhauser-enhanced nuclear magnetic resonance at less than 1 μ T using an atomic magnetometer
- 1 March 2019
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 300, 149-152
Open AccessIn-situ Overhauser-enhanced nuclear magnetic resonance at less than 1 μ T using an atomic magnetometer