SHSeong-Min Hwang

Seong-Min Hwang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Seong-Min Hwang has a total of 60 co-authors. Here are the top co-authors by number of shared publications:

  • Kiwoong Kim

    Korea Research Institute of Standards and Science

    8 shared publications
  • Seong-Joo Lee

    Quantum Magnetic Imaging Team, Korea Research Institute of Standards and Science, Daejeon 34113, Republic of Korea

    7 shared publications
  • Chan Seok Kang

    Center for Brain and Cognition Measurement, Korea Research Institute of Standards and Science (KRISS), Doryong-dong, Yuseong-gu, Daejeon 305-340, Republic of Korea

    5 shared publications
  • Yong-Ho Lee

    Center for Brain and Cognition Measurement, Korea Research Institute of Standards and Science (KRISS), Doryong-dong, Yuseong-gu, Daejeon 305-340, Republic of Korea

    5 shared publications
  • Guy Salama

    University of Pittsburgh, Pittsburgh, Pennsylvania, USA

    3 shared publications
  • Kyoung J. Lee

    National Creative Research Initiative Center for Neuro-Dynamics and Department of Physics, Korea University, Seoul 136-701, Korea

    3 shared publications

Latest Publications

  • Open Access

    Development of a Polymer-Based MEG-Compatible Vibrotactile Stimulator for Studying Neuromagnetic Somatosensory Responses

    by Min-Young Kim, Hyukchan Kwon, Won-Hyeong Park, Tae-Heon Yang, Sang-Youn Kim, Seong-Min Hwang, Kiwoong Kim

    Vibrotactile technology has been gaining increasing interest for effective human-computer communication in various applications. In addition to psychophysical approaches commonly used to study tactile vibrations, neurocognitive responses to vibrotactile stimuli can provide new insights into mechanisms underlying human vibrotactile perception. In this study, we developed a magnetoencephalography (MEG)-compatible vibrotactile stimulation device based on a polyvinyl chloride (PVC) gel actuator to study neuromagnetic somatosensory responses. A symmetric, double-layered PVC gel structure was applied to minimize the magnetic noise from the actuator. The device was used to generate sinusoidal stimuli at high frequencies to activate mechanoreceptors responsible for high-frequency vibrations greater than 50 Hz, and this device showed very little variability in stimulation onset time from the displacement measurements. We successfully observed vibrotactile-evoked magnetic fields by analyzing whole-head MEG data recorded during the high-frequency vibrotactile stimulation of the fingertips. Prominent peak responses were observed at approximately 56 ms (M50) in the contralateral hemisphere and at approximately 100 ms (M100) in both hemispheres. We identified the activation of contralateral primary somatosensory areas as a source of the vibrotactile M50 response. These results demonstrate the feasibility of using our new device to study vibrotactile perception with neuromagnetic imaging methods.


  • Open Access

    Ultralow‐field and spin‐locking relaxation dispersion in postmortem pig brain

    by Hui Dong, Seong‐Min Hwang, Michael Wendland, Lixing You, John Clarke, Ben Inglis

    Purpose: To investigate tissue‐specific differences, a quantitative comparison was made between relaxation dispersion in postmortem pig brain measured at ultralow fields (ULF) and spin locking at 7 tesla (T). The goal was to determine whether ULF‐MRI has potential advantages for in vivo human brain imaging.Methods: Separate specimens of gray matter and white matter were investigated using an ULF‐MRI system with superconducting quantum interference device (SQUID) signal detection to measure at fields from 58.7 to 235.0 μT and using a commercial MRI scanner to measure at spin‐locking fields from 5.0 to 235.0 μT.Results: At matched field strengths, is 50 to 100% longer than . Furthermore, dispersion in is close to linear between 58.7 and 235 µT, whereas dispersion in is highly nonlinear over the same range. A subtle elbow in the dispersion at approximately 140 µT is tentatively attributed to the local dipolar field of macromolecules. It is suggested that different relaxation mechanisms dominate each method and that ULF‐MRI has a fundamentally different sensitivity to the macromolecular structure of neural tissue.Conclusions: Ultralow‐field MRI may offer distinct, quantitative advantages for human brain imaging, while simultaneously avoiding the severe heating limitation imposed on high‐field spin locking. Magn Reson Med 78:2342–2351, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


  • Open Access

    Toward a brain functional connectivity mapping modality by simultaneous imaging of coherent brainwaves

    by Kiwoong Kim, Seong-Joo Lee, Chan Seok Kang, Seong-Min Hwang, Yong-Ho Lee, Kwon-Kyu Yu


  • Development and Applications of SQUIDs in Korea

    by Yong-Ho Lee, Hyukchan Kwon, Jin-Mok Kim, Kiwoong Kim, Kwon-Kyu Yu, In-Seon Kim, Chan-Seok Kang, Seong-Joo Lee, Seong-Min Hwang, Yong-Ki Park

    As sensitive magnetic sensors, magnetometers based on superconducting quantum interference devices can be used for the detection of weak magnetic fields. These signals can be generated by diverse origins, for example, brain electric activity, myocardium electric activity, and nuclear precession of hydrogen protons. In addition, weak current induced in the low-temperature detectors, for example, transition-edge sensors can be detected using SQUIDs. And, change of magnetic flux quantum generated in a superconducting ring can be detected by SQUID, which can be used for realization of mechanical force. Thus, SQUIDs are key elements in precision metrology. In Korea, development of low-temperature SQUIDs based on Nb-Josephson junctions was started in late 1980s, and Nb-based SQUIDs have been used mainly for biomagnetic measurements; magnetocardiography and magnetoencephalography. High-Tc SQUIDs, being developed in mid 1990s, were used for magnetocardiography and nondestructive evaluation. Recently, SQUID-based low-field nuclear magnetic resonance technology is under development. In this paper, we review the past progress and recent activity of SQUID applications in Korea, with focus on biomagnetic measurements.

  • Evaluation of cancellation coil for precision magnetic measurements with strong prepolarization field inside shielded environment

    by Seong-Min Hwang, Kiwoong Kim, Chan Seok Kang, Seong-Joo Lee, Yong-Ho Lee

    Many precision magnetic measurements can benefit significantly from or even require strong prepolarization fields (Bp) and magnetically shielded environments. We describe here in detail a cancellation coil (CC) which can neutralize the Bp on the electrically conductive shield walls that may otherwise induce currents on the walls to produce a lingering transient residual field (Btr) inside the shielded environment and disrupt the measurement operations. The CC was designed using the inverse problem method to effectively neutralize magnetic fields generated on the shield walls by the Bp coil. The implemented CC was evaluated by measuring Btr using a fluxgate magnetometer at different magnetometer positions and cancellation coil currents (ICC). Multi-mode component analysis on the Btr measurements revealed two dominant components, where the component with shorter time constant comes from the current induced around the shield side walls and the other with longer time constant from the current induced on the ceiling and floor of the magnetically shielded room. The analysis also revealed the optimal ICC for each of the top, side, and bottom sections of the CC, which enables significantly easier fine-tuning of individual sections of the CC to enhance CC performance.


  • Effective cancellation of residual magnetic interference induced from a shielded environment for precision magnetic measurements

    by Seong-Min Hwang, Kiwoong Kim, Chan Seok Kang, Seong-Joo Lee, Yong-Ho Lee

    Using the method of inverse problem, we designed a cancellation coil that prevents a strong pulsed magnetic field inside a magnetically shielded room (MSR) from magnetizing and inducing large-scale eddy currents around the shielding materials. We implemented this coil with discrete current loops and evaluated it numerically and experimentally. Without the cancellation coil, the transient residual magnetic field in the middle of the MSR was greater than 0.1 μT for 63.5 ms, while the cancellation coil reduced it to less than 0.1 μT after 10.8 ms, shortening the decay time by 83.0%.


  • Application of the double relaxation oscillation superconducting quantum interference device sensor to micro-tesla 1H nuclear magnetic resonance experiments

    by Chan Seok Kang, Kiwoong Kim, Seong-Joo Lee, Seong-Min Hwang, Jin-Mok Kim, Kwon Kyu Yu, Hyukchan Kwon, Sang Kil Lee, Yong-Ho Lee

    We developed an ultra-low field (ULF)-nuclear magnetic resonance (NMR) measurement system capable of working with a measurement field (Bm) of several micro-tesla and performed basic NMR studies with a double relaxation oscillation superconducting quantum interference device (DROS) instead of conventional dc-SQUIDs. DROS is a SQUID sensor utilizing a relaxation oscillation between a dc-SQUID and a relaxation circuit; the new unit consists of an inductor and a resistor, and is connected in parallel with the SQUID. DROS has a 10 times larger flux-to-voltage transfer coefficient (∼mV/ϕ0) than that of the dc-SQUID, and this large transfer coefficient enables the acquisition of the SQUID signal with a simple flux-locked-loop (FLL) circuit using room temperature pre-amplifiers. The DROS second-order gradiometer showed average field noise of 9.2 μϕ0/√Hz in a magnetically shielded room (MSR). In addition, a current limiter formed of a Josephson junction array was put in a flux-transformer of DROS to prevent excessive currents that can be generated from the high pre-polarization field (Bp). Using this system, we measured an 1H NMR signal in water under 2.8 μT Bm field and reconstructed a one-dimensional MR image from the 1H NMR signal under a gradient field BG of 4.09 nT/mm. In addition, we confirmed that the ULF-NMR system can measure the NMR signal in the presence of metal without any distortion by measuring the NMR signal of a sample wrapped with metal. Lastly, we have measured the scalar J-coupling of trimethylphosphate and were able to confirm a clear doublet NMR signal with the coupling strength J3[P,H] = 10.4 ± 0.8 Hz. Finally, because the existing ULF-NMR/MRI studies were almost all performed with dc-SQUID based systems, we constructed a dc-SQUID-based ULF-NMR system in addition to the DROS based system and compared the characteristics of the two different systems by operating the two systems under identical experimental conditions.


  • Open Access

    Simultaneous Optical Mapping of Intracellular Free Calcium and Action Potentials from Langendorff Perfused Hearts

    by Guy Salama, Seong‐Min Hwang

    The cardiac action potential (AP) controls the rise and fall of intracellular free Ca2+(Cai), and thus the amplitude and kinetics of force generation. Besides excitation‐contraction coupling, the reverse process where Caiinfluences the AP through Cai‐dependent ionic currents has been implicated as the mechanism underlying QT alternans and cardiac arrhythmias in heart failure, ischemia/reperfusion, cardiac myopathy, myocardial infarction, congenital and drug‐induced long QT syndrome, and ventricular fibrillation. The development of dual optical mapping at high spatial and temporal resolution provides a powerful tool to investigate the role of Caianomalies in eliciting cardiac arrhythmias. This unit describes experimental protocols to map APs and Caitransients from perfused hearts by labeling the heart with two fluorescent dyes, one to measure transmembrane potential (Vm), the other Caitransients. High spatial and temporal resolution is achieved by selecting Vm and Caiprobes with the same excitation but different emission wavelengths, to avoid cross‐talk and mechanical components.Curr. Protoc. Cytom. 49:12.17.1‐12.17.32. © 2009 by John Wiley & Sons, Inc.