Seong-Min Hwang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Seong-Min Hwang has a total of 60 co-authors. Here are the top co-authors by number of shared publications:
- Kiwoong Kim
Korea Research Institute of Standards and Science
8 shared publications - Seong-Joo Lee
Quantum Magnetic Imaging Team, Korea Research Institute of Standards and Science, Daejeon 34113, Republic of Korea
7 shared publications Chan Seok Kang
Center for Brain and Cognition Measurement, Korea Research Institute of Standards and Science (KRISS), Doryong-dong, Yuseong-gu, Daejeon 305-340, Republic of Korea
5 shared publicationsYong-Ho Lee
Center for Brain and Cognition Measurement, Korea Research Institute of Standards and Science (KRISS), Doryong-dong, Yuseong-gu, Daejeon 305-340, Republic of Korea
5 shared publicationsGuy Salama
University of Pittsburgh, Pittsburgh, Pennsylvania, USA
3 shared publications- Kyoung J. Lee
National Creative Research Initiative Center for Neuro-Dynamics and Department of Physics, Korea University, Seoul 136-701, Korea
3 shared publications
Latest Publications
- Open Access
- 20 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 9235-9245
Development of a Polymer-Based MEG-Compatible Vibrotactile Stimulator for Studying Neuromagnetic Somatosensory Responses
Vibrotactile technology has been gaining increasing interest for effective human-computer communication in various applications. In addition to psychophysical approaches commonly used to study tactile vibrations, neurocognitive responses to vibrotactile stimuli can provide new insights into mechanisms underlying human vibrotactile perception. In this study, we developed a magnetoencephalography (MEG)-compatible vibrotactile stimulation device based on a polyvinyl chloride (PVC) gel actuator to study neuromagnetic somatosensory responses. A symmetric, double-layered PVC gel structure was applied to minimize the magnetic noise from the actuator. The device was used to generate sinusoidal stimuli at high frequencies to activate mechanoreceptors responsible for high-frequency vibrations greater than 50 Hz, and this device showed very little variability in stimulation onset time from the displacement measurements. We successfully observed vibrotactile-evoked magnetic fields by analyzing whole-head MEG data recorded during the high-frequency vibrotactile stimulation of the fingertips. Prominent peak responses were observed at approximately 56 ms (M50) in the contralateral hemisphere and at approximately 100 ms (M100) in both hemispheres. We identified the activation of contralateral primary somatosensory areas as a source of the vibrotactile M50 response. These results demonstrate the feasibility of using our new device to study vibrotactile perception with neuromagnetic imaging methods.
- 20 December 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 8, 9235-9245
Open AccessDevelopment of a Polymer-Based MEG-Compatible Vibrotactile Stimulator for Studying Neuromagnetic Somatosensory Responses
Vibrotactile technology has been gaining increasing interest for effective human-computer communication in various applications. In addition to psychophysical approaches commonly used to study tactile vibrations, neurocognitive responses to vibrotactile stimuli can provide new insights into mechanisms underlying human vibrotactile perception. In this study, we developed a magnetoencephalography (MEG)-compatible vibrotactile stimulation device based on a polyvinyl chloride (PVC) gel actuator to study neuromagnetic somatosensory responses. A symmetric, double-layered PVC gel structure was applied to minimize the magnetic noise from the actuator. The device was used to generate sinusoidal stimuli at high frequencies to activate mechanoreceptors responsible for high-frequency vibrations greater than 50 Hz, and this device showed very little variability in stimulation onset time from the displacement measurements. We successfully observed vibrotactile-evoked magnetic fields by analyzing whole-head MEG data recorded during the high-frequency vibrotactile stimulation of the fingertips. Prominent peak responses were observed at approximately 56 ms (M50) in the contralateral hemisphere and at approximately 100 ms (M100) in both hemispheres. We identified the activation of contralateral primary somatosensory areas as a source of the vibrotactile M50 response. These results demonstrate the feasibility of using our new device to study vibrotactile perception with neuromagnetic imaging methods.
- Open Access
- 5 February 2017
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 78 (6) , 2342-2351
Ultralow‐field and spin‐locking relaxation dispersion in postmortem pig brain
Purpose: To investigate tissue‐specific differences, a quantitative comparison was made between relaxation dispersion in postmortem pig brain measured at ultralow fields (ULF) and spin locking at 7 tesla (T). The goal was to determine whether ULF‐MRI has potential advantages for in vivo human brain imaging.Methods: Separate specimens of gray matter and white matter were investigated using an ULF‐MRI system with superconducting quantum interference device (SQUID) signal detection to measure at fields from 58.7 to 235.0 μT and using a commercial MRI scanner to measure at spin‐locking fields from 5.0 to 235.0 μT.Results: At matched field strengths, is 50 to 100% longer than . Furthermore, dispersion in is close to linear between 58.7 and 235 µT, whereas dispersion in is highly nonlinear over the same range. A subtle elbow in the dispersion at approximately 140 µT is tentatively attributed to the local dipolar field of macromolecules. It is suggested that different relaxation mechanisms dominate each method and that ULF‐MRI has a fundamentally different sensitivity to the macromolecular structure of neural tissue.Conclusions: Ultralow‐field MRI may offer distinct, quantitative advantages for human brain imaging, while simultaneously avoiding the severe heating limitation imposed on high‐field spin locking. Magn Reson Med 78:2342–2351, 2017. © 2016 International Society for Magnetic Resonance in Medicine.
- 5 February 2017
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 78 (6) , 2342-2351
Open AccessUltralow‐field and spin‐locking relaxation dispersion in postmortem pig brain
Purpose: To investigate tissue‐specific differences, a quantitative comparison was made between relaxation dispersion in postmortem pig brain measured at ultralow fields (ULF) and spin locking at 7 tesla (T). The goal was to determine whether ULF‐MRI has potential advantages for in vivo human brain imaging.Methods: Separate specimens of gray matter and white matter were investigated using an ULF‐MRI system with superconducting quantum interference device (SQUID) signal detection to measure at fields from 58.7 to 235.0 μT and using a commercial MRI scanner to measure at spin‐locking fields from 5.0 to 235.0 μT.Results: At matched field strengths, is 50 to 100% longer than . Furthermore, dispersion in is close to linear between 58.7 and 235 µT, whereas dispersion in is highly nonlinear over the same range. A subtle elbow in the dispersion at approximately 140 µT is tentatively attributed to the local dipolar field of macromolecules. It is suggested that different relaxation mechanisms dominate each method and that ULF‐MRI has a fundamentally different sensitivity to the macromolecular structure of neural tissue.Conclusions: Ultralow‐field MRI may offer distinct, quantitative advantages for human brain imaging, while simultaneously avoiding the severe heating limitation imposed on high‐field spin locking. Magn Reson Med 78:2342–2351, 2017. © 2016 International Society for Magnetic Resonance in Medicine.
- Open Access
- 1 May 2014
- Published by Elsevier in NeuroImage
- Vol. 91, 63-69
Toward a brain functional connectivity mapping modality by simultaneous imaging of coherent brainwaves
- 1 May 2014
- Published by Elsevier in NeuroImage
- Vol. 91, 63-69
Open AccessToward a brain functional connectivity mapping modality by simultaneous imaging of coherent brainwaves
- 1 January 2013
- Published by Institute of Electronics, Information and Communications Engineers (IEICE) in IEICE Transactions on Electronics
- Vol. E96.C (3) , 307-312
Development and Applications of SQUIDs in Korea
As sensitive magnetic sensors, magnetometers based on superconducting quantum interference devices can be used for the detection of weak magnetic fields. These signals can be generated by diverse origins, for example, brain electric activity, myocardium electric activity, and nuclear precession of hydrogen protons. In addition, weak current induced in the low-temperature detectors, for example, transition-edge sensors can be detected using SQUIDs. And, change of magnetic flux quantum generated in a superconducting ring can be detected by SQUID, which can be used for realization of mechanical force. Thus, SQUIDs are key elements in precision metrology. In Korea, development of low-temperature SQUIDs based on Nb-Josephson junctions was started in late 1980s, and Nb-based SQUIDs have been used mainly for biomagnetic measurements; magnetocardiography and magnetoencephalography. High-Tc SQUIDs, being developed in mid 1990s, were used for magnetocardiography and nondestructive evaluation. Recently, SQUID-based low-field nuclear magnetic resonance technology is under development. In this paper, we review the past progress and recent activity of SQUID applications in Korea, with focus on biomagnetic measurements.
- 1 January 2013
- Published by Institute of Electronics, Information and Communications Engineers (IEICE) in IEICE Transactions on Electronics
- Vol. E96.C (3) , 307-312
Development and Applications of SQUIDs in Korea
As sensitive magnetic sensors, magnetometers based on superconducting quantum interference devices can be used for the detection of weak magnetic fields. These signals can be generated by diverse origins, for example, brain electric activity, myocardium electric activity, and nuclear precession of hydrogen protons. In addition, weak current induced in the low-temperature detectors, for example, transition-edge sensors can be detected using SQUIDs. And, change of magnetic flux quantum generated in a superconducting ring can be detected by SQUID, which can be used for realization of mechanical force. Thus, SQUIDs are key elements in precision metrology. In Korea, development of low-temperature SQUIDs based on Nb-Josephson junctions was started in late 1980s, and Nb-based SQUIDs have been used mainly for biomagnetic measurements; magnetocardiography and magnetoencephalography. High-Tc SQUIDs, being developed in mid 1990s, were used for magnetocardiography and nondestructive evaluation. Recently, SQUID-based low-field nuclear magnetic resonance technology is under development. In this paper, we review the past progress and recent activity of SQUID applications in Korea, with focus on biomagnetic measurements.
- 15 April 2012
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 111 (8) , 083916
Evaluation of cancellation coil for precision magnetic measurements with strong prepolarization field inside shielded environment
Many precision magnetic measurements can benefit significantly from or even require strong prepolarization fields (Bp) and magnetically shielded environments. We describe here in detail a cancellation coil (CC) which can neutralize the Bp on the electrically conductive shield walls that may otherwise induce currents on the walls to produce a lingering transient residual field (Btr) inside the shielded environment and disrupt the measurement operations. The CC was designed using the inverse problem method to effectively neutralize magnetic fields generated on the shield walls by the Bp coil. The implemented CC was evaluated by measuring Btr using a fluxgate magnetometer at different magnetometer positions and cancellation coil currents (ICC). Multi-mode component analysis on the Btr measurements revealed two dominant components, where the component with shorter time constant comes from the current induced around the shield side walls and the other with longer time constant from the current induced on the ceiling and floor of the magnetically shielded room. The analysis also revealed the optimal ICC for each of the top, side, and bottom sections of the CC, which enables significantly easier fine-tuning of individual sections of the CC to enhance CC performance.
- 15 April 2012
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 111 (8) , 083916
Evaluation of cancellation coil for precision magnetic measurements with strong prepolarization field inside shielded environment
Many precision magnetic measurements can benefit significantly from or even require strong prepolarization fields (Bp) and magnetically shielded environments. We describe here in detail a cancellation coil (CC) which can neutralize the Bp on the electrically conductive shield walls that may otherwise induce currents on the walls to produce a lingering transient residual field (Btr) inside the shielded environment and disrupt the measurement operations. The CC was designed using the inverse problem method to effectively neutralize magnetic fields generated on the shield walls by the Bp coil. The implemented CC was evaluated by measuring Btr using a fluxgate magnetometer at different magnetometer positions and cancellation coil currents (ICC). Multi-mode component analysis on the Btr measurements revealed two dominant components, where the component with shorter time constant comes from the current induced around the shield side walls and the other with longer time constant from the current induced on the ceiling and floor of the magnetically shielded room. The analysis also revealed the optimal ICC for each of the top, side, and bottom sections of the CC, which enables significantly easier fine-tuning of individual sections of the CC to enhance CC performance.
- 26 September 2011
- Published by AIP Publishing in Applied Physics Letters
- Vol. 99 (13) , 132506
Effective cancellation of residual magnetic interference induced from a shielded environment for precision magnetic measurements
Using the method of inverse problem, we designed a cancellation coil that prevents a strong pulsed magnetic field inside a magnetically shielded room (MSR) from magnetizing and inducing large-scale eddy currents around the shielding materials. We implemented this coil with discrete current loops and evaluated it numerically and experimentally. Without the cancellation coil, the transient residual magnetic field in the middle of the MSR was greater than 0.1 μT for 63.5 ms, while the cancellation coil reduced it to less than 0.1 μT after 10.8 ms, shortening the decay time by 83.0%.
- 26 September 2011
- Published by AIP Publishing in Applied Physics Letters
- Vol. 99 (13) , 132506
Effective cancellation of residual magnetic interference induced from a shielded environment for precision magnetic measurements
Using the method of inverse problem, we designed a cancellation coil that prevents a strong pulsed magnetic field inside a magnetically shielded room (MSR) from magnetizing and inducing large-scale eddy currents around the shielding materials. We implemented this coil with discrete current loops and evaluated it numerically and experimentally. Without the cancellation coil, the transient residual magnetic field in the middle of the MSR was greater than 0.1 μT for 63.5 ms, while the cancellation coil reduced it to less than 0.1 μT after 10.8 ms, shortening the decay time by 83.0%.
- 1 September 2011
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 110 (5) , 053906
Application of the double relaxation oscillation superconducting quantum interference device sensor to micro-tesla 1H nuclear magnetic resonance experiments
We developed an ultra-low field (ULF)-nuclear magnetic resonance (NMR) measurement system capable of working with a measurement field (Bm) of several micro-tesla and performed basic NMR studies with a double relaxation oscillation superconducting quantum interference device (DROS) instead of conventional dc-SQUIDs. DROS is a SQUID sensor utilizing a relaxation oscillation between a dc-SQUID and a relaxation circuit; the new unit consists of an inductor and a resistor, and is connected in parallel with the SQUID. DROS has a 10 times larger flux-to-voltage transfer coefficient (∼mV/ϕ0) than that of the dc-SQUID, and this large transfer coefficient enables the acquisition of the SQUID signal with a simple flux-locked-loop (FLL) circuit using room temperature pre-amplifiers. The DROS second-order gradiometer showed average field noise of 9.2 μϕ0/√Hz in a magnetically shielded room (MSR). In addition, a current limiter formed of a Josephson junction array was put in a flux-transformer of DROS to prevent excessive currents that can be generated from the high pre-polarization field (Bp). Using this system, we measured an 1H NMR signal in water under 2.8 μT Bm field and reconstructed a one-dimensional MR image from the 1H NMR signal under a gradient field BG of 4.09 nT/mm. In addition, we confirmed that the ULF-NMR system can measure the NMR signal in the presence of metal without any distortion by measuring the NMR signal of a sample wrapped with metal. Lastly, we have measured the scalar J-coupling of trimethylphosphate and were able to confirm a clear doublet NMR signal with the coupling strength J3[P,H] = 10.4 ± 0.8 Hz. Finally, because the existing ULF-NMR/MRI studies were almost all performed with dc-SQUID based systems, we constructed a dc-SQUID-based ULF-NMR system in addition to the DROS based system and compared the characteristics of the two different systems by operating the two systems under identical experimental conditions.
- 1 September 2011
- Published by AIP Publishing in Journal of Applied Physics
- Vol. 110 (5) , 053906
Application of the double relaxation oscillation superconducting quantum interference device sensor to micro-tesla 1H nuclear magnetic resonance experiments
We developed an ultra-low field (ULF)-nuclear magnetic resonance (NMR) measurement system capable of working with a measurement field (Bm) of several micro-tesla and performed basic NMR studies with a double relaxation oscillation superconducting quantum interference device (DROS) instead of conventional dc-SQUIDs. DROS is a SQUID sensor utilizing a relaxation oscillation between a dc-SQUID and a relaxation circuit; the new unit consists of an inductor and a resistor, and is connected in parallel with the SQUID. DROS has a 10 times larger flux-to-voltage transfer coefficient (∼mV/ϕ0) than that of the dc-SQUID, and this large transfer coefficient enables the acquisition of the SQUID signal with a simple flux-locked-loop (FLL) circuit using room temperature pre-amplifiers. The DROS second-order gradiometer showed average field noise of 9.2 μϕ0/√Hz in a magnetically shielded room (MSR). In addition, a current limiter formed of a Josephson junction array was put in a flux-transformer of DROS to prevent excessive currents that can be generated from the high pre-polarization field (Bp). Using this system, we measured an 1H NMR signal in water under 2.8 μT Bm field and reconstructed a one-dimensional MR image from the 1H NMR signal under a gradient field BG of 4.09 nT/mm. In addition, we confirmed that the ULF-NMR system can measure the NMR signal in the presence of metal without any distortion by measuring the NMR signal of a sample wrapped with metal. Lastly, we have measured the scalar J-coupling of trimethylphosphate and were able to confirm a clear doublet NMR signal with the coupling strength J3[P,H] = 10.4 ± 0.8 Hz. Finally, because the existing ULF-NMR/MRI studies were almost all performed with dc-SQUID based systems, we constructed a dc-SQUID-based ULF-NMR system in addition to the DROS based system and compared the characteristics of the two different systems by operating the two systems under identical experimental conditions.
- 5 October 2010
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 23 (11)
Pre-polarization enhancement by dynamic nuclear polarization in SQUID-based ultra-low-field nuclear magnetic resonance
- 5 October 2010
- Published by IOP Publishing in Superconductor Science and Technology
- Vol. 23 (11)
Pre-polarization enhancement by dynamic nuclear polarization in SQUID-based ultra-low-field nuclear magnetic resonance
- Open Access
- 1 July 2009
- Published by Wiley in Current Protocols in Cytometry
- Vol. 49 (1) , 12.17.1-12.17.32
Simultaneous Optical Mapping of Intracellular Free Calcium and Action Potentials from Langendorff Perfused Hearts
The cardiac action potential (AP) controls the rise and fall of intracellular free Ca2+(Cai), and thus the amplitude and kinetics of force generation. Besides excitation‐contraction coupling, the reverse process where Caiinfluences the AP through Cai‐dependent ionic currents has been implicated as the mechanism underlying QT alternans and cardiac arrhythmias in heart failure, ischemia/reperfusion, cardiac myopathy, myocardial infarction, congenital and drug‐induced long QT syndrome, and ventricular fibrillation. The development of dual optical mapping at high spatial and temporal resolution provides a powerful tool to investigate the role of Caianomalies in eliciting cardiac arrhythmias. This unit describes experimental protocols to map APs and Caitransients from perfused hearts by labeling the heart with two fluorescent dyes, one to measure transmembrane potential (Vm), the other Caitransients. High spatial and temporal resolution is achieved by selecting Vm and Caiprobes with the same excitation but different emission wavelengths, to avoid cross‐talk and mechanical components.Curr. Protoc. Cytom. 49:12.17.1‐12.17.32. © 2009 by John Wiley & Sons, Inc.
- 1 July 2009
- Published by Wiley in Current Protocols in Cytometry
- Vol. 49 (1) , 12.17.1-12.17.32
Open AccessSimultaneous Optical Mapping of Intracellular Free Calcium and Action Potentials from Langendorff Perfused Hearts
The cardiac action potential (AP) controls the rise and fall of intracellular free Ca2+(Cai), and thus the amplitude and kinetics of force generation. Besides excitation‐contraction coupling, the reverse process where Caiinfluences the AP through Cai‐dependent ionic currents has been implicated as the mechanism underlying QT alternans and cardiac arrhythmias in heart failure, ischemia/reperfusion, cardiac myopathy, myocardial infarction, congenital and drug‐induced long QT syndrome, and ventricular fibrillation. The development of dual optical mapping at high spatial and temporal resolution provides a powerful tool to investigate the role of Caianomalies in eliciting cardiac arrhythmias. This unit describes experimental protocols to map APs and Caitransients from perfused hearts by labeling the heart with two fluorescent dyes, one to measure transmembrane potential (Vm), the other Caitransients. High spatial and temporal resolution is achieved by selecting Vm and Caiprobes with the same excitation but different emission wavelengths, to avoid cross‐talk and mechanical components.Curr. Protoc. Cytom. 49:12.17.1‐12.17.32. © 2009 by John Wiley & Sons, Inc.