Hon Ming Yip
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Hon Ming Yip has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Raymond H. W. Lam
Department of Biomedical Engineering, College of Biomedicine, City University of Hong Kong, Hong Kong 999077, China
3 shared publications - Xin Cui
Key Laboratory of Biomaterials of Guangdong Higher Education Institutes, Department of Biomedical Engineering, Jinan University, Guangzhou 510632, China
2 shared publications - Agrim Prasad
Department of Mechanical and Biomedical Engineering, City University of Hong Kong, Kowloon, Hong Kong
1 shared publication - Alan T. H. Lau
Department of Mechanical and Biomedical Engineering, City University of Hong Kong, Hong Kong
1 shared publication - Benjamin Meyer
University of Geneva
1 shared publication Chengpeng Yang
Department of Mechanical and Biomedical Engineering, City University of Hong Kong, Hong Kong
1 shared publication
Latest Publications
- Open Access
- 6 January 2023
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 120 (2)
Perfect adaptation achieved by transport limitations governs the inorganic phosphate response in S. cerevisiae
Cells cope with and adapt to ever-changing environmental conditions. Sophisticated regulatory networks allow cells to adjust to these fluctuating environments. One such archetypal system is the Saccharomyces cerevisiae Pho regulon. When external inorganic phosphate ( P i ) concentration is low, the Pho regulon activates, expressing genes that scavenge external and internal P i . However, the precise mechanism controlling this regulon remains elusive. We conducted a systems analysis of the Pho regulon on the single-cell level under well-controlled environmental conditions. This analysis identified a robust, perfectly adapted Pho regulon state in intermediate P i conditions, and we identified an intermediate nuclear localization state of the transcriptional master regulator Pho4p. The existence of an intermediate nuclear Pho4p state unifies and resolves outstanding incongruities associated with the Pho regulon, explains the observed programmatic states of the Pho regulon, and improves our general understanding of how nature evolves and controls sophisticated gene regulatory networks. We further propose that robustness and perfect adaptation are not achieved through complex network-centric control but by simple transport biophysics. The ubiquity of multitransporter systems suggests that similar mechanisms could govern the function of other regulatory networks as well.
- 6 January 2023
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 120 (2)
Open AccessPerfect adaptation achieved by transport limitations governs the inorganic phosphate response in S. cerevisiae
Cells cope with and adapt to ever-changing environmental conditions. Sophisticated regulatory networks allow cells to adjust to these fluctuating environments. One such archetypal system is the Saccharomyces cerevisiae Pho regulon. When external inorganic phosphate ( P i ) concentration is low, the Pho regulon activates, expressing genes that scavenge external and internal P i . However, the precise mechanism controlling this regulon remains elusive. We conducted a systems analysis of the Pho regulon on the single-cell level under well-controlled environmental conditions. This analysis identified a robust, perfectly adapted Pho regulon state in intermediate P i conditions, and we identified an intermediate nuclear localization state of the transcriptional master regulator Pho4p. The existence of an intermediate nuclear Pho4p state unifies and resolves outstanding incongruities associated with the Pho regulon, explains the observed programmatic states of the Pho regulon, and improves our general understanding of how nature evolves and controls sophisticated gene regulatory networks. We further propose that robustness and perfect adaptation are not achieved through complex network-centric control but by simple transport biophysics. The ubiquity of multitransporter systems suggests that similar mechanisms could govern the function of other regulatory networks as well.
- Open Access
- 16 April 2021
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 118 (18)
A high-throughput microfluidic nanoimmunoassay for detecting anti–SARS-CoV-2 antibodies in serum or ultralow-volume blood samples
Significance: COVID-19, caused by SARS-CoV-2, led to an unprecedented global health crisis. As the majority of people infected with SARS-CoV-2 have no or only mild symptoms, many cases aren’t captured by direct testing. However, it is important to establish the true spread of the virus by identifying how many people have been exposed. Detection of anti–SARS-CoV-2–specific antibodies in blood samples can help us understand how the pandemic is evolving over time. We developed a sensitive and specific assay that performs 1,024 measurements in parallel. To enable decentralized blood sample collection, the method can detect antibodies in a small drop of blood obtainable by finger pricking, and the blood can be collected and shipped with a simple, low-cost blood glucose test strip.
- 16 April 2021
- Published by National Academy of Sciences in Proceedings of the National Academy of Sciences
- Vol. 118 (18)
Open AccessA high-throughput microfluidic nanoimmunoassay for detecting anti–SARS-CoV-2 antibodies in serum or ultralow-volume blood samples
Significance: COVID-19, caused by SARS-CoV-2, led to an unprecedented global health crisis. As the majority of people infected with SARS-CoV-2 have no or only mild symptoms, many cases aren’t captured by direct testing. However, it is important to establish the true spread of the virus by identifying how many people have been exposed. Detection of anti–SARS-CoV-2–specific antibodies in blood samples can help us understand how the pandemic is evolving over time. We developed a sensitive and specific assay that performs 1,024 measurements in parallel. To enable decentralized blood sample collection, the method can detect antibodies in a small drop of blood obtainable by finger pricking, and the blood can be collected and shipped with a simple, low-cost blood glucose test strip.
- Open Access
- 15 July 2014
- Published by Wiley in The Scientific World Journal
- Vol. 2014, 1-14
Automated Long-Term Monitoring of Parallel Microfluidic Operations Applying a Machine Vision-Assisted Positioning Method
As microfluidics has been applied extensively in many cell and biochemical applications, monitoring the related processes is an important requirement. In this work, we design and fabricate a high-throughput microfluidic device which contains 32 microchambers to perform automated parallel microfluidic operations and monitoring on an automated stage of a microscope. Images are captured at multiple spots on the device during the operations for monitoring samples in microchambers in parallel; yet the device positions may vary at different time points throughout operations as the device moves back and forth on a motorized microscopic stage. Here, we report an image-based positioning strategy to realign the chamber position before every recording of microscopic image. We fabricate alignment marks at defined locations next to the chambers in the microfluidic device as reference positions. We also develop image processing algorithms to recognize the chamber positions in real-time, followed by realigning the chambers to their preset positions in the captured images. We perform experiments to validate and characterize the device functionality and the automated realignment operation. Together, this microfluidic realignment strategy can be a platform technology to achieve precise positioning of multiple chambers for general microfluidic applications requiring long-term parallel monitoring of cell and biochemical activities.
- 15 July 2014
- Published by Wiley in The Scientific World Journal
- Vol. 2014, 1-14
Open AccessAutomated Long-Term Monitoring of Parallel Microfluidic Operations Applying a Machine Vision-Assisted Positioning Method
As microfluidics has been applied extensively in many cell and biochemical applications, monitoring the related processes is an important requirement. In this work, we design and fabricate a high-throughput microfluidic device which contains 32 microchambers to perform automated parallel microfluidic operations and monitoring on an automated stage of a microscope. Images are captured at multiple spots on the device during the operations for monitoring samples in microchambers in parallel; yet the device positions may vary at different time points throughout operations as the device moves back and forth on a motorized microscopic stage. Here, we report an image-based positioning strategy to realign the chamber position before every recording of microscopic image. We fabricate alignment marks at defined locations next to the chambers in the microfluidic device as reference positions. We also develop image processing algorithms to recognize the chamber positions in real-time, followed by realigning the chambers to their preset positions in the captured images. We perform experiments to validate and characterize the device functionality and the automated realignment operation. Together, this microfluidic realignment strategy can be a platform technology to achieve precise positioning of multiple chambers for general microfluidic applications requiring long-term parallel monitoring of cell and biochemical activities.
- 1 June 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 10, 162-167
Development of an omnidirectional mobile robot using a RGB-D sensor for indoor navigation
The demand of service robots has increased in recent decades, especially for indoor robotics. Omnidirectional drive system is suitable to work in crowded and small space indoor environment like home, office, hospital etc. In modern robotics, researchers are keen to equip sensing ability into robots, which encourages the development and application of sensors in robot such as gyroscope and camera. Using a RGB-D sensor is a possible method to provide vision ability to a mobile robot. Moreover, simultaneous localization and mapping (SLAM) is one of popular approach to make robot identify its position by sensing the surrounding environment. In this work, we developed an omnidirectional driving mobile robot using Mecanum wheels, which is equipped a RGB-D camera to obtain the surrounding information. The calibration of the robot including the motors, the velocity and the object depth information were done. Demonstrations of object detection and mapping are included in this paper.
- 1 June 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 10, 162-167
Development of an omnidirectional mobile robot using a RGB-D sensor for indoor navigation
The demand of service robots has increased in recent decades, especially for indoor robotics. Omnidirectional drive system is suitable to work in crowded and small space indoor environment like home, office, hospital etc. In modern robotics, researchers are keen to equip sensing ability into robots, which encourages the development and application of sensors in robot such as gyroscope and camera. Using a RGB-D sensor is a possible method to provide vision ability to a mobile robot. Moreover, simultaneous localization and mapping (SLAM) is one of popular approach to make robot identify its position by sensing the surrounding environment. In this work, we developed an omnidirectional driving mobile robot using Mecanum wheels, which is equipped a RGB-D camera to obtain the surrounding information. The calibration of the robot including the motors, the velocity and the object depth information were done. Demonstrations of object detection and mapping are included in this paper.
- 25 March 2014
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 4 (32) , 16662-16673
Microfluidic long-term differential oxygenation for bacterial growth characteristics analyses
Dissolved oxygen is a critical micro-environmental factor to determine the growth characteristics of bacteria, such as cell viability, migration, aggregation and metabolic processes. Here, we report a microfluidic long-term oxygenator which can support high-throughput parallel cell cultures under multiple defined oxygenation conditions (0–42 ppm). An array of oxygen–nitrogen gas micro-mixers is developed and fabricated in the device to generate stable oxygen concentrations for the oxygenation process. A water-jacket layer located between the gas layer and the cell culture chamber is applied to block evaporation and maintain the conditions of the culture media in the chamber. Furthermore, we perform simulations and experiments to investigate the functions of the gas mixers and the water jackets. We also conduct culture experiments to study the long-term growth (up to one week) and aggregation of three selected dental bacteria (Streptococcus mutans, Actinomyces viscosus and Fusobacterium nucleatum) under ranges of oxygenation conditions. These particular results can provide important insights into their roles in dental biofilm formation. Overall, this work demonstrates that the long-term microfluidic oxygenation approach can effectively regulate defined dissolved-oxygen levels in cell microenvironments. Importantly, this oxygenation approach can be further applied to general long-term analyses of cells for their behavioral, metabolic and genetic responses, and their biofilm formation processes.
- 25 March 2014
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 4 (32) , 16662-16673
Microfluidic long-term differential oxygenation for bacterial growth characteristics analyses
Dissolved oxygen is a critical micro-environmental factor to determine the growth characteristics of bacteria, such as cell viability, migration, aggregation and metabolic processes. Here, we report a microfluidic long-term oxygenator which can support high-throughput parallel cell cultures under multiple defined oxygenation conditions (0–42 ppm). An array of oxygen–nitrogen gas micro-mixers is developed and fabricated in the device to generate stable oxygen concentrations for the oxygenation process. A water-jacket layer located between the gas layer and the cell culture chamber is applied to block evaporation and maintain the conditions of the culture media in the chamber. Furthermore, we perform simulations and experiments to investigate the functions of the gas mixers and the water jackets. We also conduct culture experiments to study the long-term growth (up to one week) and aggregation of three selected dental bacteria (Streptococcus mutans, Actinomyces viscosus and Fusobacterium nucleatum) under ranges of oxygenation conditions. These particular results can provide important insights into their roles in dental biofilm formation. Overall, this work demonstrates that the long-term microfluidic oxygenation approach can effectively regulate defined dissolved-oxygen levels in cell microenvironments. Importantly, this oxygenation approach can be further applied to general long-term analyses of cells for their behavioral, metabolic and genetic responses, and their biofilm formation processes.
- Open Access
- 10 February 2014
- Published by MDPI AG in Micromachines
- Vol. 5 (1) , 50-65
Dynamics of Microvalve Operations in Integrated Microfluidics
Pneumatic microvalves are widely used key components for automating liquid manipulation and flow control in microfluidics for more than one decade. Due to their robust operations and the ease of fabrication, tremendous microfluidic systems have been developed with the multiple microvalves for higher throughput and extended functionalities. Therefore, operation performance of the microvalves in the integrated microfluidic devices is crucial to the related applications, in fields such as micro-flows, cell analyses, drug discovery, and physical/chemical detections. It has been reported that operation performance of the microvalves are highly sensitive to the device configuration and pressurization scheme. This implies the further development of integrated microfluidics with a larger number of the valves may suffer the problems of undetermined microvalve behaviors during operations, which can become an unavoidable hurdle in the device design and optimization processes. Herein, we characterize responses of the individual microvalves for different operation configurations, e.g., membrane thicknesses and driving pressures. We investigate also the effects in microfluidics integrated with the more valves, through experiments, modeling and simulations. We show that dynamics of the microvalves is indeed influenced by the configurations, levels of design complexity and positions in the devices. Overall, taken dynamics of the microvalve responses into considerations, this work provides insights and guidelines for better designs of integrated microfluidics for the future applications requiring higher throughput and improved operation performance.
- 10 February 2014
- Published by MDPI AG in Micromachines
- Vol. 5 (1) , 50-65
Open AccessDynamics of Microvalve Operations in Integrated Microfluidics
Pneumatic microvalves are widely used key components for automating liquid manipulation and flow control in microfluidics for more than one decade. Due to their robust operations and the ease of fabrication, tremendous microfluidic systems have been developed with the multiple microvalves for higher throughput and extended functionalities. Therefore, operation performance of the microvalves in the integrated microfluidic devices is crucial to the related applications, in fields such as micro-flows, cell analyses, drug discovery, and physical/chemical detections. It has been reported that operation performance of the microvalves are highly sensitive to the device configuration and pressurization scheme. This implies the further development of integrated microfluidics with a larger number of the valves may suffer the problems of undetermined microvalve behaviors during operations, which can become an unavoidable hurdle in the device design and optimization processes. Herein, we characterize responses of the individual microvalves for different operation configurations, e.g., membrane thicknesses and driving pressures. We investigate also the effects in microfluidics integrated with the more valves, through experiments, modeling and simulations. We show that dynamics of the microvalves is indeed influenced by the configurations, levels of design complexity and positions in the devices. Overall, taken dynamics of the microvalve responses into considerations, this work provides insights and guidelines for better designs of integrated microfluidics for the future applications requiring higher throughput and improved operation performance.