SMSatoshi Matsuyama

Satoshi Matsuyama

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Satoshi Matsuyama has a total of 219 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Quantitative elemental masses of a single marine phytoplankton evaluated with soft X-ray spectro-ptychography

    by Jordan T. O’NEal, Satoshi Matsuyama, Kai Sakurai, Kyota Yoshinaga, Yu Nakata, Chiho Funaki, Yoko Takeo, Takenori Shimamura, Makina Yabashi, Haruhiko Ohashi, et al.

    We demonstrate quantitative, high-resolution imaging of oxygen and iron in a single centric diatom, Thalassiosira weissflogii , using soft X-ray spectro-ptychography (SP), capable of elemental mapping. The quantitative accuracy of SP is tested by measuring the oxygen mass of SiO 2 microspheres. SP is then directly compared to scanning X-ray fluorescence microscopy by measuring the iron mass within the same T. weissflogii cell, demonstrating consistent distributions with similar spatial resolution. The oxygen mass measurement of the T. weissflogii cell shows significantly higher resolution compared with iron due to the large edge jump ratio, showing the potential for quantitative measurements of the mass of light elements, carbon, nitrogen, and oxygen, in a single cell.

  • Development of an ultraprecise glue-free bimorph deformable mirror with a length of 460 mm

    by Yoshio Ichii, Takato Inoue, Xianbo Shi, Luca Rebuffi, Shinsaku Shiroma, Shinya Aono, Hiroki Nakamori, Fumiharu Teramae, Lahsen Assoufid, Satoshi Matsuyama, et al.

    Lead zirconate titanate (PZT) bimorph mirrors are essential for performing multiple functions, such as beam shaping, wavefront correction, and dynamic focusing with adjustable beam sizes. They typically consist of a mirror substrate with PZT electrodes bonded to the substrate using a thin epoxy film. However, glue-bonded PZT mirrors exhibit low reproducibility in measurement results. One source of this variability is water absorption by the substrate’s epoxy adhesive during wet fabrication processes, such as elastic emission machining (EEM), which leads to swelling and deformation. Additionally, longer deformable bimorph mirrors require larger PZT electrodes, further complicating their design and fabrication, particularly during bonding and ultraprecise metrology. To address these challenges, silver nanoparticles were employed to bond PZT elements to the silicon (Si) mirror, eliminating the need for epoxy glue. In this study, we developed an inorganic-glue-free PZT bimorph mirror with a length of 460 mm and 28 channels. The glue-free bonding method successfully ensured the high reproducibility of measurements after water immersion. This approach resulted in a shape error of only 0.41 nm root mean square after the figure correction process using an ultraprecise EEM process. Scanning acoustic tomography and basic response function tests confirmed the success of the bonding process, showing no critical voids. Furthermore, the shape changes induced by applying voltages to the PZT electrodes closely matched predictions obtained from simulations. These results demonstrate the reliability and precision of the proposed glue-free bonding technique, paving the way for improved performance of new PZT bimorph mirrors.


  • Open Access

    Multi-frame blind deconvolution using X-ray microscope images of an in-plane rotating sample

    by Shinnosuke Kurimoto, Takato Inoue, Hitoshi Aoto, Toshiki Ito, Satsuki Ito, Yoshiki Kohmura, Makina Yabashi, Satoshi Matsuyama

    We propose a multi-frame blind deconvolution method using an in-plane rotating sample optimized for X-ray microscopy, where the application of existing deconvolution methods is technically difficult. Untrained neural networks are employed as the reconstruction algorithm to enable robust reconstruction against stage motion errors caused by the in-plane rotation of samples. From demonstration experiments using full-field X-ray microscopy with advanced Kirkpatrick–Baez mirror optics at SPring-8, a spatial resolution of 34 nm (half period) was successfully achieved by removing the wavefront aberration and improving the apparent numerical aperture. This method can contribute to the cost-effective improvement of X-ray microscopes with imperfect lenses as well as the reconstruction of the phase information of samples and lenses.


  • Monolithic deformable mirror based on lithium niobate single crystal for high-resolution X-ray adaptive microscopy

    by Takato Inoue, Sota Nakabayashi, Kota Uematsu, Yuto Tanaka, Hiroki Nakamori, Yoshiki Kohmura, Makina Yabashi, Satoshi Matsuyama

    X-ray microscopy is very promising not only for nondestructive and high-spatial-resolution observation of the internal structure of a sample but also for elemental distribution and chemical state analysis. However, the spatial resolution of microscopes remains unsatisfactory owing to the fabrication error in the objective lens. To realize an ultra-high-resolution, we propose and develop a monolithic deformable mirror based on a lithium niobite single crystal and a novel adaptive imaging system based on it. An X-ray interferometer confirmed that shape modification is possible with an accuracy of 0.67 nm in peak to valley under high stability (0.17 nm over 7 h) and hysteresis-free deformation control. Introducing this adaptive mirror into an X-ray microscope based on advanced Kirkpatrick-Baez mirror optics and correcting the wavefront aberration demonstrated that the X-ray image quality could be significantly improved.


  • Top Cited Papers

    Extreme focusing of hard X-ray free-electron laser pulses enables 7 nm focus width and 1022 W cm−2 intensity

    by Jumpei Yamada, Satoshi Matsuyama, Ichiro Inoue, Taito Osaka, Takato Inoue, Nami Nakamura, Yuto Tanaka, Yuichi Inubushi, Toshinori Yabuuchi, Kensuke Tono, et al.


  • Open Access

    A lipid index for risk of hyperlipidemia caused by anti-retroviral drugs

    by Mari Shimura, Nobuyo Higashi-Kuwata, Asuka Fujiwara, Mai Taniguchi, Takayuki Ichinose, Fumie Hamano, Masaaki Uematsu, Takato Inoue, Satoshi Matsuyama, Takahiro Suzuki, et al.


  • Propagation-based phase-contrast imaging method for full-field X-ray microscopy using advanced Kirkpatrick–Baez mirrors

    by Yuto Tanaka, Jumpei Yamada, Takato Inoue, Takashi Kimura, Mari Shimura, Yoshiki Kohmura, Makina Yabashi, Tetsuya Ishikawa, Kazuto Yamauchi, Satoshi Matsuyama

    We demonstrate a propagation-based phase-contrast imaging method for full-field X-ray microscopy based on advanced Kirkpatrick–Baez (AKB) mirrors to achieve high-contrast observations of weak phase objects and correct field curvature aberrations. Through a demonstration performed at SPring-8, the phase contrast of weak phase objects such as polystyrene spheres and chemically fixed cells was successfully observed with high sensitivity (∼0.03 rad). Furthermore, the field of view of the AKB mirrors was expanded to the full area of the obtained images (25 × 30 µm) by correcting the field curvature aberration using reconstructed complex wavefields.


  • Wide field-of-view x-ray imaging optical system using grazing-incidence mirrors

    by Satoshi Matsuyama, Takato Inoue, Kentaro Hata, Haruhito Iriyama, Kazuto Yamauchi

    A field-curvature-corrected imaging optical system for x-ray microscopy using only grazing-incidence mirrors is proposed. It combines a Wolter type I (WO1) mirror pair, which forms a real image, with field curvature correction (FCC) optics—a convex hyperbolic mirror pair—that form a virtual image; compensation of the field curvatures realizes a wide field-of-view (FOV) and high magnification. Ray-tracing and wave-optics simulations verified the efficacy of the design, for which a FOV width was 111 µm—4.7 times larger than that for the uncorrected WO1 design. The addition of FCC optics also produced a 2.3-fold increase in magnification.

  • Fabrication for a 400 mm long glue-free deformable mirror (Conference Presentation)

    by Yoshio Ichii, Hiromi Okada, Shinsaku Shiroma, Shinya Aono, Masahiko Kanaoka, Takato Inoue, Satoshi Matsuyama, Kazuto Yamauchi

    PZT (lead zirconate titanate)-glued bimorph deformable mirrors are widely used in hard X-ray regimes, however, they have not yet been used in soft X-ray regimes because they are less compatible for usage under high vacuum. Therefore, we have developed a glue-free bimorph deformable mirror, in which silver nanoparticles were employed to bond PZT actuators to mirror substrates. In this study, we manufactured a 400 mm long deformable mirror which has 30 channels on plane mirror surfaces. We evaluated the PZT response by applying voltage to each electrode.

  • High-throughput deterministic plasma etching using array-type plasma generator system

    by Yasuhisa Sano, Ken Nishida, Ryohei Asada, Shinya Okayama, Daisetsu Toh, Satoshi Matsuyama, Kazuto Yamauchi

    A deterministic processing method is a high-precision finishing method, where the to-be-removed amount of material at each point of the work surface is calculated based on an accurately measured present surface shape and is removed precisely using a numerically controlled (NC) processing system. Although this method has achieved nanometer-scale accuracy, the method requires considerable time to scan the work surface, leading to low productivity. Therefore, using an individual on–off controllable array-type plasma generator covering the entire work surface, enabling simultaneous NC plasma processing is proposed herein. A novel intermittent gas flow system was constructed using cyclic on–off control of the gas supply and exhaust valves instead of the commonly used continuous gas flow to achieve uniform in-plane plasma etching. It was found that uniform removal could be achieved by combining it with a pulse-modulated high-frequency power supply and setting the plasma generation time in one cycle to be sufficiently short. Furthermore, a power control approach was developed for maintaining a constant plasma state, even while varying the plasma-generating array elements, which resulted in a demonstration experiment of NC plasma etching that successfully reduced the thickness variation of a silicon substrate.