Juhani Kataja
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Juhani Kataja has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Ilkka Laakso
Aalto University
5 shared publications - Anouar Belahcen
Aalto University
2 shared publications - Jakub Szałatkiewicz
Industrial Research Institute for Automation and Measurements PIAP
2 shared publications - Janita Nissi
Department of Electrical Engineering and Automation and Aalto Neuroimaging, Aalto University, Espoo, Finland
2 shared publications Juha Ruokolainen
2 shared publicationsJukka I. Toivanen
University of Jyväskylä, Jyäskylä, Finland
2 shared publications
Latest Publications
- Open Access
- 1 November 2025
- Published by AIP Publishing in Physics of Plasmas
- Vol. 32 (11)
Neural networks as a lossy compression and restart/recovery strategy for high-dimensional plasma simulations
High-resolution simulations, such as those of plasma dynamics in the Earth's magnetosphere, generate vast amounts of data that challenge storage and processing capabilities, especially in the Exascale computing era. Managing these data volumes requires innovative solutions that balance compression efficiency with the accuracy required for scientific analysis. In this work, we present a novel approach for lossy runtime data compression tailored for high-dimensional velocity distribution functions (VDFs) using the Vlasiator code. Our method integrates implicit neural representations, specifically Multi-Layer Perceptrons (MLPs), to train on and compress VDFs dynamically during the simulation runtime. We address the challenges of preserving physical correctness while achieving high compression ratios by employing techniques such as Fourier feature encoding and sinusoidal activation functions to mitigate spectral bias. We compare our method with industry-standard methods such as ZFP and demonstrate significant improvements in compression efficiency without compromising physical correctness.
- 1 November 2025
- Published by AIP Publishing in Physics of Plasmas
- Vol. 32 (11)
Open AccessNeural networks as a lossy compression and restart/recovery strategy for high-dimensional plasma simulations
High-resolution simulations, such as those of plasma dynamics in the Earth's magnetosphere, generate vast amounts of data that challenge storage and processing capabilities, especially in the Exascale computing era. Managing these data volumes requires innovative solutions that balance compression efficiency with the accuracy required for scientific analysis. In this work, we present a novel approach for lossy runtime data compression tailored for high-dimensional velocity distribution functions (VDFs) using the Vlasiator code. Our method integrates implicit neural representations, specifically Multi-Layer Perceptrons (MLPs), to train on and compress VDFs dynamically during the simulation runtime. We address the challenges of preserving physical correctness while achieving high compression ratios by employing techniques such as Fourier feature encoding and sinusoidal activation functions to mitigate spectral bias. We compare our method with industry-standard methods such as ZFP and demonstrate significant improvements in compression efficiency without compromising physical correctness.
- Open Access
- 1 August 2024
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 21 (4) , 046038
In vivo and dosimetric investigation on electrical vestibular stimulation with frequency- and amplitude-modulated currents
Objective. Normal function of the vestibular system can be disturbed using a noninvasive technique called electrical vestibular stimulation (EVS), which alters a person’s sense of balance and causes false sensations of movement. EVS has been widely used to study the function of the vestibular system, and it has recently gained interest as a therapeutic tool to improve postural stability and help those suffering from vestibular dysfunction. Yet, understanding of how EVS stimulates the vestibular system, the current intensity needed to produce an effect and the frequencies at which it occurs have remained unclear. Approach. The effect of EVS on postural sway was examined in five participants using sinusoidal alternating current with time-varying amplitude from 0 to 1.5 mA and frequency from 0.1 to 10 Hz for three electrode configurations. Dosimetry of the current flow inside the head was conducted using anatomically realistic computational models created individually for each subject based on magnetic resonance imaging data. An estimate for the minimal field strength capable of affecting the vestibular system was calculated with the finite element method. Main results. Bipolar EVS at frequencies up to 10 Hz caused harmonic full-body swaying, and the frequency of the sway was the same as that of the stimulation current. The size of the sway was amplified by increasing the current intensity. Dosimetry modeling indicated that, for 0.2 mA current, the average electric field strength in the vestibular system was approximately 10–30 mV m−1, depending on the electrode montage. The size of the measured postural sway was proportional to the montage-specific electric field strength in the vestibular system. Significance. The results provide insight to EVS’s working mechanisms and improve its potential as a tool to study the sense of balance.
- 1 August 2024
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 21 (4) , 046038
Open AccessIn vivo and dosimetric investigation on electrical vestibular stimulation with frequency- and amplitude-modulated currents
Objective. Normal function of the vestibular system can be disturbed using a noninvasive technique called electrical vestibular stimulation (EVS), which alters a person’s sense of balance and causes false sensations of movement. EVS has been widely used to study the function of the vestibular system, and it has recently gained interest as a therapeutic tool to improve postural stability and help those suffering from vestibular dysfunction. Yet, understanding of how EVS stimulates the vestibular system, the current intensity needed to produce an effect and the frequencies at which it occurs have remained unclear. Approach. The effect of EVS on postural sway was examined in five participants using sinusoidal alternating current with time-varying amplitude from 0 to 1.5 mA and frequency from 0.1 to 10 Hz for three electrode configurations. Dosimetry of the current flow inside the head was conducted using anatomically realistic computational models created individually for each subject based on magnetic resonance imaging data. An estimate for the minimal field strength capable of affecting the vestibular system was calculated with the finite element method. Main results. Bipolar EVS at frequencies up to 10 Hz caused harmonic full-body swaying, and the frequency of the sway was the same as that of the stimulation current. The size of the sway was amplified by increasing the current intensity. Dosimetry modeling indicated that, for 0.2 mA current, the average electric field strength in the vestibular system was approximately 10–30 mV m−1, depending on the electrode montage. The size of the measured postural sway was proportional to the montage-specific electric field strength in the vestibular system. Significance. The results provide insight to EVS’s working mechanisms and improve its potential as a tool to study the sense of balance.
- Open Access
- 3 April 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (8) , 085004
Verification of neuronavigated TMS accuracy using structured-light 3D scans
Objective. To investigate the reliability and accuracy of the manual three-point co-registration in neuronavigated transcranial magnetic stimulation (TMS). The effect of the error in landmark pointing on the coil placement and on the induced electric and magnetic fields was examined. Approach. The position of the TMS coil on the head was recorded by the neuronavigation system and by 3D scanning for ten healthy participants. The differences in the coil locations and orientations and the theoretical error values for electric and magnetic fields between the neuronavigated and 3D scanned coil positions were calculated. In addition, the sensitivity of the coil location on landmark accuracy was calculated. Main results. The measured distances between the neuronavigated and 3D scanned coil locations were on average 10.2 mm, ranging from 3.1 to 18.7 mm. The error in angles were on average from two to three degrees. The coil misplacement caused on average a 29% relative error in the electric field with a range from 9% to 51%. In the magnetic field, the same error was on average 33%, ranging from 10% to 58%. The misplacement of landmark points could cause a 1.8-fold error for the coil location. Significance. TMS neuronavigation with three landmark points can cause a significant error in the coil position, hampering research using highly accurate electric field calculations. Including 3D scanning to the process provides an efficient method to achieve a more accurate coil position.
- 3 April 2024
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (8) , 085004
Open AccessVerification of neuronavigated TMS accuracy using structured-light 3D scans
Objective. To investigate the reliability and accuracy of the manual three-point co-registration in neuronavigated transcranial magnetic stimulation (TMS). The effect of the error in landmark pointing on the coil placement and on the induced electric and magnetic fields was examined. Approach. The position of the TMS coil on the head was recorded by the neuronavigation system and by 3D scanning for ten healthy participants. The differences in the coil locations and orientations and the theoretical error values for electric and magnetic fields between the neuronavigated and 3D scanned coil positions were calculated. In addition, the sensitivity of the coil location on landmark accuracy was calculated. Main results. The measured distances between the neuronavigated and 3D scanned coil locations were on average 10.2 mm, ranging from 3.1 to 18.7 mm. The error in angles were on average from two to three degrees. The coil misplacement caused on average a 29% relative error in the electric field with a range from 9% to 51%. In the magnetic field, the same error was on average 33%, ranging from 10% to 58%. The misplacement of landmark points could cause a 1.8-fold error for the coil location. Significance. TMS neuronavigation with three landmark points can cause a significant error in the coil position, hampering research using highly accurate electric field calculations. Including 3D scanning to the process provides an efficient method to achieve a more accurate coil position.
- Open Access
- 22 December 2023
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (1) , 015012
Predicting the hotspot location and motor threshold prior to transcranial magnetic stimulation using electric field modelling
Objective. To investigate whether the motor threshold (MT) and the location of the motor hotspot in transcranial magnetic stimulation (TMS) can be predicted with computational models of the induced electric field. Approach. Individualized computational models were constructed from structural magnetic resonance images of ten healthy participants, and the induced electric fields were determined with the finite element method. The models were used to optimize the location and direction of the TMS coil on the scalp to produce the largest electric field at a predetermined cortical target location. The models were also used to predict how the MT changes as the magnetic coil is moved to various locations over the scalp. To validate the model predictions, the motor evoked potentials were measured from the first dorsal interosseous (FDI) muscle with TMS in the ten participants. Both computational and experimental methods were preregistered prior to the experiments. Main results. Computationally optimized hotspot locations were nearly as accurate as those obtained using manual hotspot search procedures. The mean Euclidean distance between the predicted and the measured hotspot locations was approximately 1.3 cm with a 0.8 cm bias towards the anterior direction. Exploratory analyses showed that the bias could be removed by changing the cortical target location that was used for the prediction. The results also indicated a statistically significant relationship ( p < 0.001) between the calculated electric field and the MT measured at several locations on the scalp. Significance. The results show that the individual TMS hotspot can be located using computational analysis without stimulating the subject or patient even once. Adapting computational modelling would save time and effort in research and clinical use of TMS.
- 22 December 2023
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 69 (1) , 015012
Open AccessPredicting the hotspot location and motor threshold prior to transcranial magnetic stimulation using electric field modelling
Objective. To investigate whether the motor threshold (MT) and the location of the motor hotspot in transcranial magnetic stimulation (TMS) can be predicted with computational models of the induced electric field. Approach. Individualized computational models were constructed from structural magnetic resonance images of ten healthy participants, and the induced electric fields were determined with the finite element method. The models were used to optimize the location and direction of the TMS coil on the scalp to produce the largest electric field at a predetermined cortical target location. The models were also used to predict how the MT changes as the magnetic coil is moved to various locations over the scalp. To validate the model predictions, the motor evoked potentials were measured from the first dorsal interosseous (FDI) muscle with TMS in the ten participants. Both computational and experimental methods were preregistered prior to the experiments. Main results. Computationally optimized hotspot locations were nearly as accurate as those obtained using manual hotspot search procedures. The mean Euclidean distance between the predicted and the measured hotspot locations was approximately 1.3 cm with a 0.8 cm bias towards the anterior direction. Exploratory analyses showed that the bias could be removed by changing the cortical target location that was used for the prediction. The results also indicated a statistically significant relationship ( p < 0.001) between the calculated electric field and the MT measured at several locations on the scalp. Significance. The results show that the individual TMS hotspot can be located using computational analysis without stimulating the subject or patient even once. Adapting computational modelling would save time and effort in research and clinical use of TMS.
- Open Access
- 28 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 65 (6) , 1647-1655
Material Coarsening Strategy for Structured Meshless Multigrid Method for Dosimetry in Anisotropic Human Body Models
In this article, a novel multigrid-based method is developed for modeling of electric fields and currents in electrically anisotropic and heterogeneous media. The method is useful for numerical assessment of human exposure to low-frequency electromagnetic fields, which has been typically performed using isotropic models of the human body. The method is matrix-free and based on structured voxelized grids. Numerical tests indicate that the method has all typical benefits of multigrid methods, i.e., convergence in a constant number of iterations and linear complexity in terms of the number of degrees of freedom. The developed method is applied to the dosimetry of the induced electric field in ten anatomically realistic models of the human head exposed to uniform 50-Hz magnetic fields. The models are constructed from magnetic resonance images and account for the electrical anisotropy of the brain tissues via diffusion weighted images. The dosimetry modeling shows that the tissue anisotropy leads to a small but significant increase (14% on average) of the 99th percentile induced electric field strength in the white matter of the brain. However, isotropic models can still provide sufficient accuracy for dosimetry if this slight underestimation of the 99th percentile electric field strength is accounted for.
- 28 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 65 (6) , 1647-1655
Open AccessMaterial Coarsening Strategy for Structured Meshless Multigrid Method for Dosimetry in Anisotropic Human Body Models
In this article, a novel multigrid-based method is developed for modeling of electric fields and currents in electrically anisotropic and heterogeneous media. The method is useful for numerical assessment of human exposure to low-frequency electromagnetic fields, which has been typically performed using isotropic models of the human body. The method is matrix-free and based on structured voxelized grids. Numerical tests indicate that the method has all typical benefits of multigrid methods, i.e., convergence in a constant number of iterations and linear complexity in terms of the number of degrees of freedom. The developed method is applied to the dosimetry of the induced electric field in ten anatomically realistic models of the human head exposed to uniform 50-Hz magnetic fields. The models are constructed from magnetic resonance images and account for the electrical anisotropy of the brain tissues via diffusion weighted images. The dosimetry modeling shows that the tissue anisotropy leads to a small but significant increase (14% on average) of the 99th percentile induced electric field strength in the white matter of the brain. However, isotropic models can still provide sufficient accuracy for dosimetry if this slight underestimation of the 99th percentile electric field strength is accounted for.
- Open Access
- 1 August 2021
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 18 (4) , 0460f3
A probabilistic transcranial magnetic stimulation localization method
Objective. Transcranial magnetic stimulation (TMS) can be used to safely and noninvasively activate brain tissue. However, the characteristic parameters of the neuronal activation have been largely unclear. In this work, we propose a novel neuronal activation model and develop a method to infer its parameters from measured motor evoked potential signals. Approach. The connection between neuronal activation due to an induced electric field and a measured motor threshold is modeled. The posterior distribution of the model parameters are inferred from measurement data using Bayes’ formula. The measurements are the active motor thresholds obtained with multiple stimulating coil locations, and the parameters of the model are the location, preferred direction of activation, and threshold electric field value of the activation site. The posterior distribution is sampled using a Markov chain Monte Carlo method. We quantify the plausibility of the model by calculating the marginal likelihood of the measured thresholds. The method is validated with synthetic data and applied to motor threshold measurements from the first dorsal interosseus muscle in five healthy participants. Main results. The method produces a probability distribution for the activation location, from which a minimal volume where the activation occurs with 95% probability can be derived. For eight or nine stimulating coil locations, the smallest such a volume obtained was approximately 100 mm3. The 95% probability volume intersected the pre-central gyral crown and the anterior wall of the central sulcus, and the preferred direction was perpendicular to the central sulcus, both findings being consistent with the literature. Furthermore, it was not possible to rule out if the activation occurred either in the white or grey matter. In one participant, two distinct activations sites were found while others exhibited a unique site. Significance. The method is both generic and robust, and it lays a foundation for a framework that enables accurate analysis and characterization of TMS activation mechanisms.
- 1 August 2021
- Published by IOP Publishing in Journal of Neural Engineering
- Vol. 18 (4) , 0460f3
Open AccessA probabilistic transcranial magnetic stimulation localization method
Objective. Transcranial magnetic stimulation (TMS) can be used to safely and noninvasively activate brain tissue. However, the characteristic parameters of the neuronal activation have been largely unclear. In this work, we propose a novel neuronal activation model and develop a method to infer its parameters from measured motor evoked potential signals. Approach. The connection between neuronal activation due to an induced electric field and a measured motor threshold is modeled. The posterior distribution of the model parameters are inferred from measurement data using Bayes’ formula. The measurements are the active motor thresholds obtained with multiple stimulating coil locations, and the parameters of the model are the location, preferred direction of activation, and threshold electric field value of the activation site. The posterior distribution is sampled using a Markov chain Monte Carlo method. We quantify the plausibility of the model by calculating the marginal likelihood of the measured thresholds. The method is validated with synthetic data and applied to motor threshold measurements from the first dorsal interosseus muscle in five healthy participants. Main results. The method produces a probability distribution for the activation location, from which a minimal volume where the activation occurs with 95% probability can be derived. For eight or nine stimulating coil locations, the smallest such a volume obtained was approximately 100 mm3. The 95% probability volume intersected the pre-central gyral crown and the anterior wall of the central sulcus, and the preferred direction was perpendicular to the central sulcus, both findings being consistent with the literature. Furthermore, it was not possible to rule out if the activation occurred either in the white or grey matter. In one participant, two distinct activations sites were found while others exhibited a unique site. Significance. The method is both generic and robust, and it lays a foundation for a framework that enables accurate analysis and characterization of TMS activation mechanisms.
- Open Access
- 20 December 2017
- Published by Walter de Gruyter GmbH in Archives of Electrical Engineering
- Vol. 66 (4) , 745-750
Open source ELMER software based FEM modeling of waveguides and resonant cavities for microwave heating and drying devices
Microwave devices are widely used in the industry and in the specialized laboratory analyses. Development of such devices requires the possibility of modeling of microwave energy distribution in the specific resonant chambers. Until now, such modeling was possible only with the use of commercial software or was limited to specific cases. The paper presents an open-source module for ELMER software for solving timeharmonic Maxwell’s equations, allowing modeling of microwave waveguide lines. Three test cases of different resonant chambers are investigated at 2.45 GHz frequency. Modeling results obtained from the open-source ELMER Vectorial Helmholtz module show that the application of this software can be effective in R&D works, enabling high-tech small and medium enterprises involvement in advanced microwave technology.
- 20 December 2017
- Published by Walter de Gruyter GmbH in Archives of Electrical Engineering
- Vol. 66 (4) , 745-750
Open AccessOpen source ELMER software based FEM modeling of waveguides and resonant cavities for microwave heating and drying devices
Microwave devices are widely used in the industry and in the specialized laboratory analyses. Development of such devices requires the possibility of modeling of microwave energy distribution in the specific resonant chambers. Until now, such modeling was possible only with the use of commercial software or was limited to specific cases. The paper presents an open-source module for ELMER software for solving timeharmonic Maxwell’s equations, allowing modeling of microwave waveguide lines. Three test cases of different resonant chambers are investigated at 2.45 GHz frequency. Modeling results obtained from the open-source ELMER Vectorial Helmholtz module show that the application of this software can be effective in R&D works, enabling high-tech small and medium enterprises involvement in advanced microwave technology.
- 17 August 2017
- Published by Springer Nature
- p. 123-137
OpenMP $^*$ SIMD Vectorization and Threading of the Elmer Finite Element Software- 17 August 2017
- Published by Springer Nature
- p. 123-137
OpenMP $^*$ SIMD Vectorization and Threading of the Elmer Finite Element Software- 20 January 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 53 (6) , 1-4
Computation of Magnetic Forces Using Degenerated Air-Gap Element
This paper presents an efficient method to calculate the magnetic forces on bodies in contact. The forces are computed through the local application of the virtual work principle on degenerated air-gap elements. The results from this method are compared with those from other software and validated with measurements on a permanent magnet setup. Not only is this technique very accurate, but it also reduces the computational burden related to the problematic meshing of thin layers. The implementation of this method in an open source finite element software having facilities for higher order elements and parallel computation unlocks a cost effective and effectual platform for an electromechanical computation of electromechanical devices and magnetic materials.
- 20 January 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Magnetics
- Vol. 53 (6) , 1-4
Computation of Magnetic Forces Using Degenerated Air-Gap Element
This paper presents an efficient method to calculate the magnetic forces on bodies in contact. The forces are computed through the local application of the virtual work principle on degenerated air-gap elements. The results from this method are compared with those from other software and validated with measurements on a permanent magnet setup. Not only is this technique very accurate, but it also reduces the computational burden related to the problematic meshing of thin layers. The implementation of this method in an open source finite element software having facilities for higher order elements and parallel computation unlocks a cost effective and effectual platform for an electromechanical computation of electromechanical devices and magnetic materials.
- 1 December 2016
- Published by Springer Nature
- p. 172-186
Advances in FEM Based Modeling of Waveguide and Waveguide Systems for Microwave Applications, Using Newly Developed Open Source Software
- 1 December 2016
- Published by Springer Nature
- p. 172-186
Advances in FEM Based Modeling of Waveguide and Waveguide Systems for Microwave Applications, Using Newly Developed Open Source Software