  • Open Access

    Effect of Multiple Extrusion Cycles on Particle and Chemical Emissions and Mechanical and Thermal Properties of High-Density Polyethylene 3D Printing Filaments Made from Virgin and Post-Consumer Waste Plastics

    by Aleksandr B. Stefaniak, Lauren N. Bowers, Callee M. Walsh, Sonette Du Preez, Elizabeth D. Brusak, Jason E. Ham, Ryan F. LeBouf, M. Abbas Virji, Johan L. Du Plessis

    Distributed recycling of high-density polyethylene (HDPE) into filament for use in material extrusion 3D printing has been proposed as part of a circular economy. There is a gap in the understanding of the potential for HDPE to release contaminants that are potentially hazardous to human health during reuse. Herein, HDPE from post-consumer packaging waste was sorted into food and non-food (NF) streams and virgin HDPE was taken as a benchmark material. All materials were extruded into filaments and recycled multiple times while monitoring emissions. In general, particle and organic chemical emissions decreased by 93 to 99% and 73 to 99%, respectively, with increased reprocessing cycle without appreciable decline in mechanical (Young’s modulus decreased by 5 to 16%), processability (melt flow index stable from 0.2 to 0.7 g/10 min for waste plastics), and thermal properties (crystallinity ranged from a 6% decrease to a 9% increase) of plastics. An exception was a sub-stream of NF plastic that had increased particle emissions (up to 3100%) with reprocessing cycle. Reductions in emissions during filament extrusion appeared to be more influenced by reprocessing cycle than by any specific process step (grinding, etc.). The progressive decline in emissions without appreciable loss of polymer integrity could be exploited to pre-condition HDPE to reduce potential hazardous emissions prior to extruding into filament. This work helps fill the knowledge gap on approaches to recycling plastics in distributed settings such as home-based businesses, which is critical for developing effective recommendations for controls to enable safe work practices such as the use of ventilation to minimize exposures.

  • Influence of filament loading technique on surrogate active pharmaceutical ingredient particle emissions during material extrusion 3D printing of tablets

    by Aleksandr B. Stefaniak, Lauren N. Bowers, Elizabeth D. Brusak, Robert P. Streicher, Alvaro Goyanes, Sherri A. Friend, Duane R. Hammond, Ryan F. LeBouf, Chaolong Qi, M.ABbas Virji


  • Influence of puff topographies on e-liquid heating temperature, emission characteristics and modeled lung deposition of Puff Bar™

    by Anand Ranpara, Aleksandr B. Stefaniak, Elizabeth Fernandez, Lauren N. Bowers, Elizabeth D. Arnold, Ryan F. LeBouf

    Puff Bar™, one of the latest designs of e-cigarettes, heats a mixture of liquid using a battery-powered coil at certain temperatures to emit aerosol. This study presents a mass-based characterization of emissions from seven flavors of Puff Bar™ devices by aerosolizing with three puff topographies [(puff volume: 55 < 65 < 75-mL) within 4-seconds at 30-seconds interval]. We evaluated the effects of puff topographies on heating temperatures; characterized particles using a cascade impactor; and measured volatile carbonyl compounds (VCCs). Modeled dosimetry and calculated mass median aerodynamic diameters (MMADs) were used to estimate regional, total respiratory deposition of the inhaled aerosol and exhaled fractions that could pose secondhand exposure risk. Temperatures of Puff Bar™ e-liquids increased with increasing puff volumes: 55mL (116.6 °C), 65mL (128.3 °C), and 75mL (168.9 °C). Flavor types significantly influenced MMADs, total mass of particles, and VCCs (µg/puff: 2.15-2.30) in Puff Bar™ emissions (p < 0.05). Increasing puff volume (mL:55 < 65 < 75) significantly increased total mass (mg/puff: 4.6 < 5.6 < 6.2) of particles without substantially changing MMADs (∼1µm:1.02 ∼ 0.99 ∼ 0.98). Aerosol emissions were estimated to deposit in the pulmonary region of e-cigarette user (41–44%), which could have toxicological importance. More than 2/3 (67–77%) of inhaled particles were estimated to be exhaled by users, which could affect bystanders. The VCCs measured contained carcinogens—formaldehyde (29.6%) and acetaldehyde (16.4%)—as well as respiratory irritants: acetone (23.9%), isovaleraldehyde (14.5%), and acrolein (4.9%). As Puff Bar™ emissions contain respirable particles and harmful chemicals, efforts should be made to minimize exposures, especially in indoor settings where people (including vulnerable populations) spend most of their life-time. Graphical abstract


  • Multi-instrument assessment of fine and ultrafine titanium dioxide aerosols

    by Anand Ranpara, Ryan F. LeBouf, Timothy R. Nurkiewicz, Jinghai Yi, Jared L. Cumpston, Aleksandr B. Stefaniak

    The measurement of fine (diameter: 100 nanometers–2.5 micrometers) and ultrafine (UF: < 100 nanometers) titanium dioxide (TiO2) particles is instrument dependent. Differences in measurements exist between toxicological and field investigations for the same exposure metric such as mass, number, or surface area because of variations in instruments used, operating parameters, or particle-size measurement ranges. Without appropriate comparison, instrument measurements create a disconnect between toxicological and field investigations for a given exposure metric. Our objective was to compare a variety of instruments including multiple metrics including mass, number, and surface area (SA) concentrations for assessing different concentrations of separately aerosolized fine and UF TiO2 particles. The instruments studied were (1) DustTrak™ DRX, (2) personal DataRAMs™ (PDR), (3) GRIMMTM, and (4) diffusion charger (DC). Two devices of each field-study instrument (DRX, PDR, GRIMM, and DC) were used to measure various metrics while adjusting for gravimetric mass concentrations of fine and UF TiO2 particles in controlled chamber tests. An analysis of variance (ANOVA) was used to apportion the variance to inter-instrument (between different instrument-types), inter-device (within instrument), and intra-device components. Performance of each instrument-device was calculated using root mean squared error compared to reference methods: close-faced cassette and gravimetric analysis for mass and scanning mobility particle sizer (SMPS) real-time monitoring for number and SA concentrations. Generally, inter-instrument variability accounted for the greatest (62.6% or more) source of variance for mass, and SA-based concentrations of fine and UF TiO2 particles. However, higher intra-device variability (53.7%) was observed for number concentrations measurements with fine particles compared to inter-instrument variability (40.8%). Inter-device variance range(0.5–5.5%) was similar for all exposure metrics. DRX performed better in measuring mass closer to gravimetric than PDRs for fine and UF TiO2. Number concentrations measured by GRIMMs and SA measurements by DCs were considerably (40.8–86.9%) different from the reference (SMPS) method for comparable size ranges of fine and UF TiO2. This information may serve to aid in interpreting assessments in risk models, epidemiologic studies, and development of occupational exposure limits, relating to health effect endpoints identified in toxicological studies considering similar instruments evaluated in this study. Graphical abstract


  • Inhalation and Skin Exposure to Chemicals in Hospital Settings

    by M. Abbas Virji, Lauren N. Bowers, Ryan F. LeBouf


  • Open Access

    Potential for Exposure to Particles and Gases throughout Vat Photopolymerization Additive Manufacturing Processes

    by Lauren N. Bowers, Aleksandr B. Stefaniak, Alycia K. Knepp, Ryan F. LeBouf, Stephen B. Martin, Anand C. Ranpara, Dru A. Burns, M. Abbas Virji

    Vat photopolymerization (VP), a type of additive manufacturing process that cures resin to build objects, can emit potentially hazardous particles and gases. We evaluated two VP technologies, stereolithography (SLA) and digital light processing (DLP), in three separate environmental chambers to understand task-based impacts on indoor air quality. Airborne particles, total volatile organic compounds (TVOCs), and/or specific volatile organic compounds (VOCs) were monitored during each task to evaluate their exposure potential. Regardless of duration, all tasks released particles and organic gases, though concentrations varied between SLA and DLP processes and among tasks. Maximum particle concentrations reached 1200 #/cm3 and some aerosols contained potentially hazardous elements such as barium, chromium, and manganese. TVOC concentrations were highest for the isopropyl alcohol (IPA) rinsing, soaking, and drying post-processing tasks (up to 36.8 mg/m3), lowest for the resin pouring pre-printing, printing, and resin recovery post-printing tasks (up to 0.1 mg/m3), and intermediate for the curing post-processing task (up to 3 mg/m3). Individual VOCs included, among others, the potential occupational carcinogen acetaldehyde and the immune sensitizer 2-hydroxypropyl methacrylate (pouring, printing, recovery, and curing tasks). Careful consideration of all tasks is important for the development of strategies to minimize indoor air pollution and exposure potential from VP processes.


  • Assessment of worker chemical exposures in California vape shops

    by Kathleen R. Attfield, Marley Zalay, Leonard M. Zwack, Eric K. Glassford, Ryan F. LeBouf, Barbara L. Materna

    E-cigarettes are battery-operated devices that heat a liquid mixture to make an aerosol that is inhaled, or vaped, by the user. Vape shops are retail environments for customer demand of diverse e-liquid flavors and hardware options, which create unique worker exposure concerns. To characterize exposures to vape shop workers, especially to flavoring chemicals associated with known respiratory toxicity, this study recruited vape shops from the San Francisco Bay Area. In six shops, air concentrations were measured for volatile organic compounds, formaldehyde, flavoring chemicals, and nicotine in personal and/or area samples; analyzed components of e-liquids vaped during field visits; and assessed metals on surface wipe samples. Interviews and observations were conducted over the course of a workday in the same six shops and performed interviews only in an additional six where sampling was not conducted. Detections of the alpha-diketone butter flavoring chemicals diacetyl and/or 2,3-pentanedione were common: in the headspace of purchased e-liquids (18 of 26 samples), in personal air samples (five of 16), and in area air samples (two of six shops). Two exceedances of recommended exposure limits for 2,3-pentanedione (a short-term exposure limit and an eight-hour time weighted average) were measured in personal air samples. Other compounds detected in area and personal air samples included substitutes for diacetyl and 2,3-pentanedione (acetoin and 2,3-hexanedione) and compounds that may be contaminants or impurities. Furthermore, a large variety (82) of other flavoring chemicals were detected in area air samples. None of the 12 shops interviewed had a health and safety program. Six shops reported no use of any personal protective equipment (PPE) (e.g., gloves, chemical resistant aprons, eye protection) and the others stated occasional use; however, no PPE use was observed during any field investigation day. Recommendations were provided to shops that included making improvements to ventilation, hygiene, use of personal protective equipment, and, if possible, avoidance of products containing the alpha-diketone flavoring chemicals. Future research is needed to evaluate the long-term health risks among workers in the vape shop retail industry and for e-cigarette use generally. Specific areas include further characterizing e-liquid constituents and emissions, evaluating ingredient health risks, evaluating the contributions of different routes of exposure (dermal, inhalation, and ingestion) and determining effective exposure mitigation measures.


  • Open Access

    Model Predictions of Occupational Exposures to Diacetyl and 2,3-Pentanedione Emitted From Roasted Whole Bean and Ground Coffee: Influence of Roast Level and Physical Form on Specific Emission Rates

    by Ryan F. LeBouf, Anand Ranpara, Elizabeth Fernandez, Dru A. Burns, Alyson R. Fortner

    Roasted coffee emits hazardous volatile organic compounds including diacetyl and 2,3-pentanedione. Workers in non-flavored coffee roasting and packaging facilities might inhale diacetyl and 2,3-pentanedione from roasted coffee above occupational exposure limits depending on their work activities and proximity to the source of emissions. Objectives of this laboratory study were to: (1) investigate factors affecting specific emission rates (SERs) of diacetyl and 2,3-pentanedione from freshly roasted coffee, (2) explore the effect of time on SERs of coffee stored in sealed bags for 10-days, and (3) predict exposures to workers in hypothetical workplace scenarios. Two roast levels (light and dark) and three physical forms (whole bean, coarse ground, and fine ground) were investigated. Particle size for whole bean and ground coffee were analyzed using geometric mean of Feret diameter. Emitted chemicals were collected on thermal desorption tubes and quantified using mass spectrometry analysis. SERs developed here coupled with information from previous field surveys provided model input to estimate worker exposures during various activities using a probabilistic, near-field/far-field model. For freshly roasted coffee, mean SER of diacetyl and 2,3-pentantedione increased with decreasing particle size of the physical form (whole bean < coarse ground < fine ground) but was not consistent with roast levels. SERs from freshly roasted coffee increased with roast level for diacetyl but did not change for 2,3-pentanedione. Mean SERs were greatest for diacetyl at 3.60 mg kg−1 h−1 for dark, fine ground and for 2,3-pentanedione at 3.88 mg kg−1 h−1 for light, fine ground. For storage, SERs of whole bean remained constant while SERs of dark roast ground coffee decreased and light roast ground coffee increased. Modeling demonstrated that near-field exposures depend on proximity to the source, duration of exposure, and air velocities in the near-field further supporting previously reported chemical air measurements in coffee roasting and packaging facilities. Control of source emissions using local exhaust ventilation especially around grinding activities as well as modification of work practices could be used to reduce exposures in this workforce.


  • Open Access

    Influence of E-Liquid Humectants, Nicotine, and Flavorings on Aerosol Particle Size Distribution and Implications for Modeling Respiratory Deposition

    by Aleksandr B. Stefaniak, Anand C. Ranpara, Mohammed Abbas Virji, Ryan F. LeBouf

    Electronic cigarette, or vaping, products are used to heat an e-liquid to form an aerosol (liquid droplets suspended in gas) that the user inhales; a portion of this aerosol deposits in their respiratory tract and the remainder is exhaled, thereby potentially creating opportunity for secondhand exposure to bystanders (e.g., in homes, automobiles, and workplaces). Particle size, a critical factor in respiratory deposition (and therefore potential for secondhand exposure), could be influenced by e-liquid composition. Hence, the purposes of this study were to (1) test the influence of laboratory-prepared e-liquid composition [ratio of propylene glycol (PG) to vegetable glycerin (VG) humectants, nicotine, and flavorings] on particle size distribution and (2) model respiratory dosimetry. All e-liquids were aerosolized using a second-generation reference e-cigarette. We measured particle size distribution based on mass using a low-flow cascade impactor (LFCI) and size distribution based on number using real-time mobility sizers. Mass median aerodynamic diameters (MMADs) of aerosol from e-liquids that contained only humectants were significantly larger compared with e-liquids that contained flavorings or nicotine (p = 0.005). Humectant ratio significantly influenced MMADs; all aerosols from e-liquids prepared with 70:30 PG:VG were significantly larger compared with e-liquids prepared with 30:70 PG:VG (p = 0.017). In contrast to the LFCI approach, the high dilution and sampling flow rate of a fast mobility particle sizer strongly influenced particle size measurements (i.e., all calculated MMAD values were < 75 nm). Dosimetry modeling using LFCI data indicated that a portion of inhaled particles will deposit throughout the respiratory tract, though statistical differences in aerosol MMADs among e-liquid formulations did not translate into large differences in deposition estimates. A portion of inhaled aerosol will be exhaled and could be a source for secondhand exposure. Use of laboratory-prepared e-liquids and a reference e-cigarette to standardize aerosol generation and a LFCI to measure particle size distribution without dilution represents an improved method to characterize physical properties of volatile aerosol particles and permitted determination of MMAD values more representative of e-cigarette aerosol in situ, which in turn, can help to improve dose modeling for users and bystanders.


  • Open Access

    Chemical Emissions From Heated Vitamin E Acetate—Insights to Respiratory Risks From Electronic Cigarette Liquid Oil Diluents Used in the Aerosolization of Δ9-THC-Containing Products

    by Ryan F. LeBouf, Anand Ranpara, Jason Ham, Michael Aldridge, Elizabeth Fernandez, Kenneth Williams, Dru A. Burns, Aleksandr B. Stefaniak

    As of February 18, 2020, the e-cigarette, or vaping, product use associated lung injury (EVALI) outbreak caused the hospitalization of a total of 2,807 patients and claimed 68 lives in the United States. Though investigations have reported a strong association with vitamin E acetate (VEA), evidence from reported EVALI cases is not sufficient to rule out the contribution of other chemicals of concern, including chemicals in either THC or non-THC products. This study characterized chemicals evolved when diluent oils were heated to temperatures that mimic e-cigarette, or vaping, products (EVPs) to investigate production of potentially toxic chemicals that might have caused lung injury. VEA, vitamin E, coconut, and medium chain triglyceride (MCT) oil were each diluted with ethanol and then tested for constituents and impurities using a gas chromatograph mass spectrometer (GC/MS). Undiluted oils were heated at 25°C (control), 150°C, and 250°C in an inert chamber to mimic a range of temperatures indicative of aerosolization from EVPs. Volatilized chemicals were collected using thermal desorption tubes, analyzed using a GC/MS, and identified. Presence of identified chemicals was confirmed using retention time and ion spectra matching with analytic standards. Direct analysis of oils, as received, revealed that VEA and vitamin E were the main constituents of their oils, and coconut and MCT oils were nearly identical having two main constituents: glycerol tricaprylate and 2-(decanoyloxy) propane-1,3-diyl dioctanoate. More chemicals were measured and with greater intensities when diluent oils were heated at 250°C compared to 150°C and 25°C. Vitamin E and coconut/MCT oils produced different chemical emissions. The presence of some identified chemicals is of potential health consequence because many are known respiratory irritants and acute respiratory toxins. Exposure to a mixture of hazardous chemicals may be relevant to the development or exacerbation of EVALI, especially when in concert with physical damage caused by lung deposition of aerosols produced by aerosolizing diluent oils.