L. van de Ridder
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Interests
L. van de Ridder has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
A. de Boer
3 shared publicationsJ. van Dijk
3 shared publicationsJ.C. Lötters
3 shared publicationsW.B.J. Hakvoort
3 shared publicationsAndré de Boer
Applied Mechanics Laboratory, Faculty of Engineering Technology, University of Twente, P.O. Box 217, Enschede 7500AE, The Netherlands
1 shared publication- Dannis M. Brouwer
University of Twente
1 shared publication
Latest Publications
- 1 June 2016
- Published by Elsevier in Mechatronics
- Vol. 36, 167-179
Coriolis mass-flow meter with integrated multi-DOF active vibration isolation
- 1 June 2016
- Published by Elsevier in Mechatronics
- Vol. 36, 167-179
Coriolis mass-flow meter with integrated multi-DOF active vibration isolation
- 12 January 2016
- Published by ASME International in Journal of Dynamic Systems, Measurement, and Control
- Vol. 138 (3) , 031005
Vibration Isolation by an Actively Compliantly Mounted Sensor Applied to a Coriolis Mass-Flow Meter
In this paper, a vibration isolated design of a Coriolis mass-flow meter (CMFM) is proposed by introducing a compliant connection between the casing and the tube displacement sensors, with the objective to obtain a relative displacement measurement of the fluid conveying tube, dependent on the tube actuation and mass-flow, but independent of external vibrations. The transfer from external vibrations to the relative displacement measurement is analyzed and the design is optimized to minimize this transfer. The influence of external vibrations on a compliant sensor element and the tube are made equal by tuning the resonance frequency and damping of the compliant sensor element and therefore the influence on the relative displacement measurement is minimized. The optimal tuning of the parameters is done actively by acceleration feedback. Based on simulation results, a prototype is built and validated. The validated design shows more than 24 dB reduction of the influence of external vibrations on the mass-flow measurement value of a CMFM, without affecting the sensitivity for mass-flow.
- 12 January 2016
- Published by ASME International in Journal of Dynamic Systems, Measurement, and Control
- Vol. 138 (3) , 031005
Vibration Isolation by an Actively Compliantly Mounted Sensor Applied to a Coriolis Mass-Flow Meter
In this paper, a vibration isolated design of a Coriolis mass-flow meter (CMFM) is proposed by introducing a compliant connection between the casing and the tube displacement sensors, with the objective to obtain a relative displacement measurement of the fluid conveying tube, dependent on the tube actuation and mass-flow, but independent of external vibrations. The transfer from external vibrations to the relative displacement measurement is analyzed and the design is optimized to minimize this transfer. The influence of external vibrations on a compliant sensor element and the tube are made equal by tuning the resonance frequency and damping of the compliant sensor element and therefore the influence on the relative displacement measurement is minimized. The optimal tuning of the parameters is done actively by acceleration feedback. Based on simulation results, a prototype is built and validated. The validated design shows more than 24 dB reduction of the influence of external vibrations on the mass-flow measurement value of a CMFM, without affecting the sensitivity for mass-flow.
- 1 December 2014
- Published by Elsevier in Control Engineering Practice
- Vol. 33, 76-83
Active vibration isolation feedback control for Coriolis Mass-Flow Meters
- 1 December 2014
- Published by Elsevier in Control Engineering Practice
- Vol. 33, 76-83
Active vibration isolation feedback control for Coriolis Mass-Flow Meters
- 1 December 2014
- Published by Elsevier in Flow Measurement and Instrumentation
- Vol. 40, 39-49
Quantification of the influence of external vibrations on the measurement error of a Coriolis mass-flow meter
- 1 December 2014
- Published by Elsevier in Flow Measurement and Instrumentation
- Vol. 40, 39-49
Quantification of the influence of external vibrations on the measurement error of a Coriolis mass-flow meter