Vibration Isolation by an Actively Compliantly Mounted Sensor Applied to a Coriolis Mass-Flow Meter
- 12 January 2016
- journal article
- Published by ASME International in Journal of Dynamic Systems, Measurement, and Control
- Vol. 138 (3) , 031005
Abstract
In this paper, a vibration isolated design of a Coriolis mass-flow meter (CMFM) is proposed by introducing a compliant connection between the casing and the tube displacement sensors, with the objective to obtain a relative displacement measurement of the fluid conveying tube, dependent on the tube actuation and mass-flow, but independent of external vibrations. The transfer from external vibrations to the relative displacement measurement is analyzed and the design is optimized to minimize this transfer. The influence of external vibrations on a compliant sensor element and the tube are made equal by tuning the resonance frequency and damping of the compliant sensor element and therefore the influence on the relative displacement measurement is minimized. The optimal tuning of the parameters is done actively by acceleration feedback. Based on simulation results, a prototype is built and validated. The validated design shows more than 24 dB reduction of the influence of external vibrations on the mass-flow measurement value of a CMFM, without affecting the sensitivity for mass-flow.Keywords
This publication has 12 references indexed in Scilit:
- Active vibration isolation feedback control for Coriolis Mass-Flow MetersControl Engineering Practice, 2014
- Coriolis flowmeters: a review of developments over the past 20 years, and an assessment of the state of the art and likely future directionsFlow Measurement and Instrumentation, 2014
- Quantification of the influence of external vibrations on the measurement error of a Coriolis mass-flow meterFlow Measurement and Instrumentation, 2014
- Vibration Control of Active Structures2011
- Mechatronic Design of Hard-Mount Concepts for Precision Equipment2008
- Coriolis mass flowmeters: Overview of the current state of the art and latest researchFlow Measurement and Instrumentation, 2006
- Effect of Mechanical Vibrations on Coriolis Mass Flow MetersJournal of Dynamic Systems, Measurement, and Control, 2003
- The influence upon Coriolis mass flow meters of external vibrations at selected frequenciesFlow Measurement and Instrumentation, 2003
- Passive Vibration Isolation2003
- A finite element dynamic analysis of spatial mechanisms with flexible linksComputer Methods in Applied Mechanics and Engineering, 1989