In-Seop Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
In-Seop Lee has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Cen Chen
Zhejiang Sci-Tech University
1 shared publication - Dong-Wook Han
Pusan National University
1 shared publication Hye Ryun Lim
Department of Medical Engineering, Yonsei University College of Medicine, 134 Shinchon-dong, Seodaemun-gu, Seoul 120-752, Republic of Korea
1 shared publication- Hyeong-Cheol Yang
Department of Dental Biomaterials Science, Dental Research Institute, School of Dentistry, Seoul National University, Seoul, Korea
1 shared publication Hyun Sook Baek
Department of Medical Engineering, Yonsei University College of Medicine, 134 Shinchon-dong, Seodaemun-gu, Seoul 120-752, Republic of Korea
1 shared publication- Ji-Youn Hong
Department of Periodontology, Kyung Hee University College of Dentistry, Periodontal-Implant Clinical Research Institute, Kyung Hee University Medical Center, Seoul, Korea
1 shared publication
Latest Publications
- 1 August 2026
- Published by IOP Publishing in Biomedical Materials
- Vol. 21 (4) , 045027
Selective laser melting of CoCrMo-Ti6Al4V bimetallic composites: fabrication, characterization, and cytocompatibility
Bimetallic structures integrating Ti6Al4V and CoCrMo alloys present a promising strategy for advanced orthopedic implants by synergistically combining high fracture toughness with excellent wear resistance. However, the direct fabrication of these dissimilar metals via selective laser melting (SLM) is significantly hindered by metallurgical incompatibility and high residual stress, which frequently lead to interfacial delamination and edge warping. In this study, a CoCrMo-Ti6Al4V bimetallic composite was successfully fabricated using SLM. To overcome manufacturing defects, a CoCrMo transition layer printed with low laser energy density was employed as a mechanical buffer to mitigate residual stresses, while optimized external support structures provided physical anchoring to suppress geometric distortion. The microstructural evolution, elemental distribution, and phase composition were systematically characterized using field-emission scanning electron microscopy, energy-dispersive x-ray spectroscopy, and x-ray diffraction. Mechanical performance was evaluated through hardness and sliding wear tests, while the biological response was assessed using human bone marrow mesenchymal stem cells (BMSCs). The results demonstrated that the three-layer architecture effectively eliminated macroscopic defects and ensured structural integrity. Furthermore, the composite exhibited a substantial enhancement in surface hardness and wear resistance, achieving an interfacial bonding strength of 43.21 ± 1.07 MPa. Fracture analysis revealed a cohesive failure mode within the transition layer, indicating robust metallurgical bonding between the dissimilar components. In vitro assessments confirmed excellent cytocompatibility, exhibiting high cell viability (>95%) and proliferation on the composite surfaces. Ultimately, this research establishes a reliable fabrication methodology for complex bimetallic components, offering broad application prospects in personalized medical devices, joint replacements, and tissue engineering.
- 1 August 2026
- Published by IOP Publishing in Biomedical Materials
- Vol. 21 (4) , 045027
Selective laser melting of CoCrMo-Ti6Al4V bimetallic composites: fabrication, characterization, and cytocompatibility
Bimetallic structures integrating Ti6Al4V and CoCrMo alloys present a promising strategy for advanced orthopedic implants by synergistically combining high fracture toughness with excellent wear resistance. However, the direct fabrication of these dissimilar metals via selective laser melting (SLM) is significantly hindered by metallurgical incompatibility and high residual stress, which frequently lead to interfacial delamination and edge warping. In this study, a CoCrMo-Ti6Al4V bimetallic composite was successfully fabricated using SLM. To overcome manufacturing defects, a CoCrMo transition layer printed with low laser energy density was employed as a mechanical buffer to mitigate residual stresses, while optimized external support structures provided physical anchoring to suppress geometric distortion. The microstructural evolution, elemental distribution, and phase composition were systematically characterized using field-emission scanning electron microscopy, energy-dispersive x-ray spectroscopy, and x-ray diffraction. Mechanical performance was evaluated through hardness and sliding wear tests, while the biological response was assessed using human bone marrow mesenchymal stem cells (BMSCs). The results demonstrated that the three-layer architecture effectively eliminated macroscopic defects and ensured structural integrity. Furthermore, the composite exhibited a substantial enhancement in surface hardness and wear resistance, achieving an interfacial bonding strength of 43.21 ± 1.07 MPa. Fracture analysis revealed a cohesive failure mode within the transition layer, indicating robust metallurgical bonding between the dissimilar components. In vitro assessments confirmed excellent cytocompatibility, exhibiting high cell viability (>95%) and proliferation on the composite surfaces. Ultimately, this research establishes a reliable fabrication methodology for complex bimetallic components, offering broad application prospects in personalized medical devices, joint replacements, and tissue engineering.
- Open Access
- 1 January 2014
- Published by XMLink in Journal of Periodontal & Implant Science
- Vol. 44 (5) , 242-250
Early bone healing onto implant surface treated by fibronectin/oxysterol for cell adhesion/osteogenic differentiation:in vivoexperimental study in dogs
Lee JS, et al. J Periodontal Implant Sci. 2014 Oct;44(5):242-250. https://doi.org/10.5051/jpis.2014.44.5.242
- 1 January 2014
- Published by XMLink in Journal of Periodontal & Implant Science
- Vol. 44 (5) , 242-250
Open AccessEarly bone healing onto implant surface treated by fibronectin/oxysterol for cell adhesion/osteogenic differentiation:in vivoexperimental study in dogs
Lee JS, et al. J Periodontal Implant Sci. 2014 Oct;44(5):242-250. https://doi.org/10.5051/jpis.2014.44.5.242
- 1 February 2007
- Published by Elsevier in Surface and Coatings Technology
- Vol. 201 (9-11) , 5729-5732
Differential cytokine responses of murine macrophage J774A.1 cells to stainless steel coated with and without hydroxyapatite
- 1 February 2007
- Published by Elsevier in Surface and Coatings Technology
- Vol. 201 (9-11) , 5729-5732
Differential cytokine responses of murine macrophage J774A.1 cells to stainless steel coated with and without hydroxyapatite