Jacob Sturdy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jacob Sturdy has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
Leif R. Hellevik
3 shared publicationsLeif Rune Hellevik
Division of Biomechanics Norwegian University of Science and Technology (NTNU) Norway
3 shared publications- Mette S. Olufsen
Department of Mathematics North Carolina State University Raleigh North Carolina USA
3 shared publications Anders T. Bråten
2 shared publications- Fredrik Eikeland Fossan
St. Olavs Hospital
2 shared publications - Johnny T. Ottesen
Department of Science and Environment, Centre for Mathematical Modeling - Human Health and Disease, IMFUFA, Roskilde University
2 shared publications
Latest Publications
- 5 June 2024
- Published by Wiley in International Journal for Numerical Methods in Biomedical Engineering
- Vol. 40 (8) , e3836
Global sensitivity analysis with multifidelity Monte Carlo and polynomial chaos expansion for vascular haemodynamics
Computational models of the cardiovascular system are increasingly used for the diagnosis, treatment, and prevention of cardiovascular disease. Before being used for translational applications, the predictive abilities of these models need to be thoroughly demonstrated through verification, validation, and uncertainty quantification. When results depend on multiple uncertain inputs, sensitivity analysis is typically the first step required to separate relevant from unimportant inputs, and is key to determine an initial reduction on the problem dimensionality that will significantly affect the cost of all downstream analysis tasks. For computationally expensive models with numerous uncertain inputs, sample‐based sensitivity analysis may become impractical due to the substantial number of model evaluations it typically necessitates. To overcome this limitation, we consider recently proposed Multifidelity Monte Carlo estimators for Sobol’ sensitivity indices, and demonstrate their applicability to an idealized model of the common carotid artery. Variance reduction is achieved combining a small number of three‐dimensional fluid–structure interaction simulations with affordable one‐ and zero‐dimensional reduced‐order models. These multifidelity Monte Carlo estimators are compared with traditional Monte Carlo and polynomial chaos expansion estimates. Specifically, we show consistent sensitivity ranks for both bi‐ (1D/0D) and tri‐fidelity (3D/1D/0D) estimators, and superior variance reduction compared to traditional single‐fidelity Monte Carlo estimators for the same computational budget. As the computational burden of Monte Carlo estimators for Sobol’ indices is significantly affected by the problem dimensionality, polynomial chaos expansion is found to have lower computational cost for idealized models with smooth stochastic response.
- 5 June 2024
- Published by Wiley in International Journal for Numerical Methods in Biomedical Engineering
- Vol. 40 (8) , e3836
Global sensitivity analysis with multifidelity Monte Carlo and polynomial chaos expansion for vascular haemodynamics
Computational models of the cardiovascular system are increasingly used for the diagnosis, treatment, and prevention of cardiovascular disease. Before being used for translational applications, the predictive abilities of these models need to be thoroughly demonstrated through verification, validation, and uncertainty quantification. When results depend on multiple uncertain inputs, sensitivity analysis is typically the first step required to separate relevant from unimportant inputs, and is key to determine an initial reduction on the problem dimensionality that will significantly affect the cost of all downstream analysis tasks. For computationally expensive models with numerous uncertain inputs, sample‐based sensitivity analysis may become impractical due to the substantial number of model evaluations it typically necessitates. To overcome this limitation, we consider recently proposed Multifidelity Monte Carlo estimators for Sobol’ sensitivity indices, and demonstrate their applicability to an idealized model of the common carotid artery. Variance reduction is achieved combining a small number of three‐dimensional fluid–structure interaction simulations with affordable one‐ and zero‐dimensional reduced‐order models. These multifidelity Monte Carlo estimators are compared with traditional Monte Carlo and polynomial chaos expansion estimates. Specifically, we show consistent sensitivity ranks for both bi‐ (1D/0D) and tri‐fidelity (3D/1D/0D) estimators, and superior variance reduction compared to traditional single‐fidelity Monte Carlo estimators for the same computational budget. As the computational burden of Monte Carlo estimators for Sobol’ indices is significantly affected by the problem dimensionality, polynomial chaos expansion is found to have lower computational cost for idealized models with smooth stochastic response.
- Open Access
- 23 April 2023
- Published by Elsevier in Measurement
- Vol. 216
Evaluating the precision and reproducibility of non-invasive deformation measurements in an arterial phantom
- 23 April 2023
- Published by Elsevier in Measurement
- Vol. 216
Open AccessEvaluating the precision and reproducibility of non-invasive deformation measurements in an arterial phantom
- Open Access
- 1 January 2022
- Published by Elsevier in Mathematical Biosciences
- Vol. 343, 108731
Parameter estimation for closed-loop lumped parameter models of the systemic circulation using synthetic data
- 1 January 2022
- Published by Elsevier in Mathematical Biosciences
- Vol. 343, 108731
Open AccessParameter estimation for closed-loop lumped parameter models of the systemic circulation using synthetic data
- Open Access
- 1 October 2021
- Published by Elsevier in Computer Methods in Applied Mechanics and Engineering
- Vol. 384
Machine learning augmented reduced-order models for FFR-prediction
- 1 October 2021
- Published by Elsevier in Computer Methods in Applied Mechanics and Engineering
- Vol. 384
Open AccessMachine learning augmented reduced-order models for FFR-prediction
- Open Access
- 1 April 2020
- Published by Elsevier in Journal of Biomechanics
- Vol. 103, 109698
Effect of side branch flow upon physiological indices in coronary artery disease
- 1 April 2020
- Published by Elsevier in Journal of Biomechanics
- Vol. 103, 109698
Open AccessEffect of side branch flow upon physiological indices in coronary artery disease
- Open Access
- 1 February 2019
- Published by Elsevier in Journal of Computational Science
- Vol. 31, 137-150
Uncertainty quantification of computational coronary stenosis assessment and model based mitigation of image resolution limitations
- 1 February 2019
- Published by Elsevier in Journal of Computational Science
- Vol. 31, 137-150
Open AccessUncertainty quantification of computational coronary stenosis assessment and model based mitigation of image resolution limitations
- 31 October 2018
- Published by Springer Nature in Cardiovascular Engineering and Technology
- Vol. 9 (4) , 597-622
Uncertainty Quantification and Sensitivity Analysis for Computational FFR Estimation in Stable Coronary Artery Disease
The main objectives of this study are to validate a reduced-order model for the estimation of the fractional flow reserve (FFR) index based on blood flow simulations that incorporate clinical imaging and patient-specific characteristics, and to assess the uncertainty of FFR predictions with respect to input data on a per patient basis.
- 31 October 2018
- Published by Springer Nature in Cardiovascular Engineering and Technology
- Vol. 9 (4) , 597-622
Uncertainty Quantification and Sensitivity Analysis for Computational FFR Estimation in Stable Coronary Artery Disease
The main objectives of this study are to validate a reduced-order model for the estimation of the fractional flow reserve (FFR) index based on blood flow simulations that incorporate clinical imaging and patient-specific characteristics, and to assess the uncertainty of FFR predictions with respect to input data on a per patient basis.
- Open Access
- 31 August 2018
- Published by Mathematical Sciences Publishers in Journal of Mechanics of Materials and Structures
- Vol. 13 (3) , 379-400
Uncertainty quantification and sensitivity analysis of material parameters in crystal plasticity finite element models
A number of studies have directly compared measurements of polycrystals' deformation to the solution of a crystal plasticity model of the same polycrystal. An accurate representation of the full 3D microstructure and the boundary conditions has been shown to be important to obtain a good correspondence between the behaviour of the real and the simulated polycrystal. However, much less is known about the relationship between the global and the local solutions of crystal plasticity models and the influence of material parameters on the local response of the polycrystal. To address these questions, uncertainty quantification and sensitivity analysis are performed on finite element models of oligocrystals with a crystal plasticity material model. The results show significant variations in the simulated stress and strain fields due to variations in the material parameters. Sensitivity analysis is used to quantify the contribution of crystal orientation, latent hardening and other material model parameters to the variability of the crystal plasticity finite element model solution. The uncertainty in the stress and strain fields and their sensitivities vary between the oligocrystals, but nevertheless, some distinct trends can be identified. The most prominent trend is that, in general, the solution is most sensitive to the variations of the latent hardening description and the crystallographic orientations of the constituent crystals.
- 31 August 2018
- Published by Mathematical Sciences Publishers in Journal of Mechanics of Materials and Structures
- Vol. 13 (3) , 379-400
Open AccessUncertainty quantification and sensitivity analysis of material parameters in crystal plasticity finite element models
A number of studies have directly compared measurements of polycrystals' deformation to the solution of a crystal plasticity model of the same polycrystal. An accurate representation of the full 3D microstructure and the boundary conditions has been shown to be important to obtain a good correspondence between the behaviour of the real and the simulated polycrystal. However, much less is known about the relationship between the global and the local solutions of crystal plasticity models and the influence of material parameters on the local response of the polycrystal. To address these questions, uncertainty quantification and sensitivity analysis are performed on finite element models of oligocrystals with a crystal plasticity material model. The results show significant variations in the simulated stress and strain fields due to variations in the material parameters. Sensitivity analysis is used to quantify the contribution of crystal orientation, latent hardening and other material model parameters to the variability of the crystal plasticity finite element model solution. The uncertainty in the stress and strain fields and their sensitivities vary between the oligocrystals, but nevertheless, some distinct trends can be identified. The most prominent trend is that, in general, the solution is most sensitive to the variations of the latent hardening description and the crystallographic orientations of the constituent crystals.
- 1 January 2017
- Published by Elsevier in Journal of Biomechanics
- Vol. 50, 188-194
Effects of arterial wall models and measurement uncertainties on cardiovascular model predictions
- 1 January 2017
- Published by Elsevier in Journal of Biomechanics
- Vol. 50, 188-194
Effects of arterial wall models and measurement uncertainties on cardiovascular model predictions
- 5 October 2016
- Published by Springer Nature in Journal of Computational Neuroscience
- Vol. 42 (1) , 11-30
Modeling the differentiation of A- and C-type baroreceptor firing patterns
The baroreceptor neurons serve as the primary transducers of blood pressure for the autonomic nervous system and are thus critical in enabling the body to respond effectively to changes in blood pressure. These neurons can be separated into two types (A and C) based on the myelination of their axons and their distinct firing patterns elicited in response to specific pressure stimuli. This study has developed a comprehensive model of the afferent baroreceptor discharge built on physiological knowledge of arterial wall mechanics, firing rate responses to controlled pressure stimuli, and ion channel dynamics within the baroreceptor neurons. With this model, we were able to predict firing rates observed in previously published experiments in both A- and C-type neurons. These results were obtained by adjusting model parameters determining the maximal ion-channel conductances. The observed variation in the model parameters are hypothesized to correspond to physiological differences between A- and C-type neurons. In agreement with published experimental observations, our simulations suggest that a twofold lower potassium conductance in C-type neurons is responsible for the observed sustained basal firing, where as a tenfold higher mechanosensitive conductance is responsible for the greater firing rate observed in A-type neurons. A better understanding of the difference between the two neuron types can potentially be used to gain more insight about pathophysiology and treatment of diseases related to baroreflex function, e.g. in patients with autonomic failure, a syndrome that is difficult to diagnose in terms of its pathophysiology.
- 5 October 2016
- Published by Springer Nature in Journal of Computational Neuroscience
- Vol. 42 (1) , 11-30
Modeling the differentiation of A- and C-type baroreceptor firing patterns
The baroreceptor neurons serve as the primary transducers of blood pressure for the autonomic nervous system and are thus critical in enabling the body to respond effectively to changes in blood pressure. These neurons can be separated into two types (A and C) based on the myelination of their axons and their distinct firing patterns elicited in response to specific pressure stimuli. This study has developed a comprehensive model of the afferent baroreceptor discharge built on physiological knowledge of arterial wall mechanics, firing rate responses to controlled pressure stimuli, and ion channel dynamics within the baroreceptor neurons. With this model, we were able to predict firing rates observed in previously published experiments in both A- and C-type neurons. These results were obtained by adjusting model parameters determining the maximal ion-channel conductances. The observed variation in the model parameters are hypothesized to correspond to physiological differences between A- and C-type neurons. In agreement with published experimental observations, our simulations suggest that a twofold lower potassium conductance in C-type neurons is responsible for the observed sustained basal firing, where as a tenfold higher mechanosensitive conductance is responsible for the greater firing rate observed in A-type neurons. A better understanding of the difference between the two neuron types can potentially be used to gain more insight about pathophysiology and treatment of diseases related to baroreflex function, e.g. in patients with autonomic failure, a syndrome that is difficult to diagnose in terms of its pathophysiology.