Gustavo Kertzscher
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Gustavo Kertzscher has a total of 567 co-authors. Here are the top co-authors by number of shared publications:
- Claus Erik Andersen
Center for Nuclear Technologies, Technical University of Denmark, Roskilde, Denmark
6 shared publications - Sam Beddar
Department of Radiation Physics, The University of Texas MD Anderson Cancer Center, Houston, TX, USA
6 shared publications - Kari Tanderup
Danish Center for Particle Therapy, Aarhus University Hospital, 8200 N Aarhus, Denmark
5 shared publications J E Cygler
2 shared publications- Jacob Graversen Johansen
Aarhus University Hospital
2 shared publications Shirin A. Enger
Medical Physics Unit, McGill University, Montreal, Quebec, Canada; Department of Biomedical Engineering, McGill University, Montreal, Quebec, Canada; Department of Oncology, McGill University, Montreal, Quebec, Canada; Research Institute of the McGill University Health Centre, Montreal, Quebec H3H 2L9, Canada; Lady Davis Institute for Medical Research, Jewish General Hospital, Montreal, Quebec H3T 1E2, Canada
2 shared publications
Latest Publications
- 25 February 2022
- Published by Elsevier in Physica Medica
- Vol. 94, S68-S69
DOSE RATE MEASUREMENTS IN PRE-CLINICAL PROTON FLASH STUDIES WITH FAST INORGANIC SCINTILLATOR DETECTOR
- 25 February 2022
- Published by Elsevier in Physica Medica
- Vol. 94, S68-S69
DOSE RATE MEASUREMENTS IN PRE-CLINICAL PROTON FLASH STUDIES WITH FAST INORGANIC SCINTILLATOR DETECTOR
- 6 September 2019
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 64 (22) , 225018
Inorganic scintillation detectors for 192Ir brachytherapy
Many brachytherapy (BT) errors could be detected with real-time in vivo dosimetry technology. Inorganic scintillation detectors (ISDs) have demonstrated promising capabilities for BT, because some ISD materials can generate scintillation signals large enough that (a) the background signal emitted in the fiber-optic cable (stem signal) is insignificant, and (b) small detector volumes can be used to avoid volume averaging effects in steep dose gradients near BT sources. We investigated the characteristics of five ISD materials to identify one that is appropriate for BT. ISDs consisting of a 0.26 to 1.0-mm3 volume of ruby (Al2O3:Cr), a mixture of Y2O3:Eu and YVO4:Eu, ZnSe:O, or CsI:Tl coupled to a fiber-optic cable were irradiated in a water-equivalent phantom using a high-dose-rate 192Ir BT source. Detectors based on plastic scintillators BCF-12 and BCF-60 (0.8 mm3 volume) were used as a reference. Measurements demonstrated that the ruby, Y2O3:Eu+YVO4:Eu, ZnSe:O, and CsI:Tl ISDs emitted scintillation signals that were up to 19, 19, 250, and 880 times greater, respectively, than that of the BCF-12 detector. While the total signals of the plastic scintillation detectors were dominated by the stem signal for source positions 0.5 cm from the fiber-optic cable and >3.5 cm from the scintillator volume, the stem signal for the ruby and Y2O3:Eu+YVO4:Eu ISDs were 2O3:Eu+YVO4:Eu ISD exhibited unstable scintillation and significant afterglow. All ISDs exhibited significant energy dependence, i.e. their dose response to distance-dependent 192Ir energy spectra differed significantly from the absorbed dose in water. Provided that energy dependence is accounted for, ZnSe:O ISDs are promising for use in error detection and patient safety monitoring during BT.
- 6 September 2019
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 64 (22) , 225018
Inorganic scintillation detectors for 192Ir brachytherapy
Many brachytherapy (BT) errors could be detected with real-time in vivo dosimetry technology. Inorganic scintillation detectors (ISDs) have demonstrated promising capabilities for BT, because some ISD materials can generate scintillation signals large enough that (a) the background signal emitted in the fiber-optic cable (stem signal) is insignificant, and (b) small detector volumes can be used to avoid volume averaging effects in steep dose gradients near BT sources. We investigated the characteristics of five ISD materials to identify one that is appropriate for BT. ISDs consisting of a 0.26 to 1.0-mm3 volume of ruby (Al2O3:Cr), a mixture of Y2O3:Eu and YVO4:Eu, ZnSe:O, or CsI:Tl coupled to a fiber-optic cable were irradiated in a water-equivalent phantom using a high-dose-rate 192Ir BT source. Detectors based on plastic scintillators BCF-12 and BCF-60 (0.8 mm3 volume) were used as a reference. Measurements demonstrated that the ruby, Y2O3:Eu+YVO4:Eu, ZnSe:O, and CsI:Tl ISDs emitted scintillation signals that were up to 19, 19, 250, and 880 times greater, respectively, than that of the BCF-12 detector. While the total signals of the plastic scintillation detectors were dominated by the stem signal for source positions 0.5 cm from the fiber-optic cable and >3.5 cm from the scintillator volume, the stem signal for the ruby and Y2O3:Eu+YVO4:Eu ISDs were 2O3:Eu+YVO4:Eu ISD exhibited unstable scintillation and significant afterglow. All ISDs exhibited significant energy dependence, i.e. their dose response to distance-dependent 192Ir energy spectra differed significantly from the absorbed dose in water. Provided that energy dependence is accounted for, ZnSe:O ISDs are promising for use in error detection and patient safety monitoring during BT.
- 1 September 2019
- Published by Elsevier in Physica Medica
- Vol. 65, 114-120
Characterization of scintillating fibers for use as positron detector in positron emission tomography
- 1 September 2019
- Published by Elsevier in Physica Medica
- Vol. 65, 114-120
Characterization of scintillating fibers for use as positron detector in positron emission tomography
- 1 April 2019
- Published by Elsevier in Physica Medica
- Vol. 60, 156-161
Dwell time verification in brachytherapy based on time resolved in vivo dosimetry
- 1 April 2019
- Published by Elsevier in Physica Medica
- Vol. 60, 156-161
Dwell time verification in brachytherapy based on time resolved in vivo dosimetry
- 1 January 2018
- Published by Elsevier in Brachytherapy
- Vol. 17 (1) , 122-132
Time-resolved in vivo dosimetry for source tracking in brachytherapy
- 1 January 2018
- Published by Elsevier in Brachytherapy
- Vol. 17 (1) , 122-132
Time-resolved in vivo dosimetry for source tracking in brachytherapy
- 26 May 2017
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 62 (12) , 5046-5075
Inorganic scintillation detectors based on Eu-activated phosphors for 192 Ir brachytherapy
The availability of real-time treatment verification during high-dose-rate (HDR) brachytherapy is currently limited. Therefore, we studied the luminescence properties of the widely commercially available scintillators using the inorganic materials Eu-activated phosphors Y 2 O 3 :Eu, YVO 4 :Eu, Y 2 O 2 S:Eu, and Gd 2 O 2 S:Eu to determine whether they could be used to accurately and precisely verify HDR brachytherapy doses in real time. The suitability for HDR brachytherapy of inorganic scintillation detectors (ISDs) based on the 4 Eu-activated phosphors in powder form was determined based on experiments with a 192 Ir HDR brachytherapy source. The scintillation intensities of the phosphors were 16–134 times greater than that of the commonly used organic plastic scintillator BCF-12. High signal intensities were achieved with an optimized packing density of the phosphor mixture and with a shortened fiber-optic cable. The influence of contaminating Cerenkov and fluorescence light induced in the fiber-optic cable (stem signal) was adequately suppressed by inserting between the fiber-optic cable and the photodetector a 25 nm band-pass filter centered at the emission peak. The spurious photoluminescence signal induced by the stem signal was suppressed by placing a long-pass filter between the scintillation detector volume and the fiber-optic cable. The time-dependent luminescence properties of the phosphors were quantified by measuring the non-constant scintillation during irradiation and the afterglow after the brachytherapy source had retracted. We demonstrated that a mixture of Y 2 O 3 :Eu and YVO 4 :Eu suppressed the time-dependence of the ISDs and that the time-dependence of Y 2 O 2 S:Eu and Gd 2 O 2 S:Eu introduced large measurement inaccuracies. We conclude that ISDs based on a mixture of Y 2 O 3 :Eu and YVO 4 :Eu are promising candidates for accurate and precise real-time verification technology for HDR BT that is cost effective and straightforward to manufacture. Widespread dissemination of this technology could lead to an improved understanding of error types and frequencies during BT and to improved patient safety during treatment.
- 26 May 2017
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 62 (12) , 5046-5075
Inorganic scintillation detectors based on Eu-activated phosphors for 192 Ir brachytherapy
The availability of real-time treatment verification during high-dose-rate (HDR) brachytherapy is currently limited. Therefore, we studied the luminescence properties of the widely commercially available scintillators using the inorganic materials Eu-activated phosphors Y 2 O 3 :Eu, YVO 4 :Eu, Y 2 O 2 S:Eu, and Gd 2 O 2 S:Eu to determine whether they could be used to accurately and precisely verify HDR brachytherapy doses in real time. The suitability for HDR brachytherapy of inorganic scintillation detectors (ISDs) based on the 4 Eu-activated phosphors in powder form was determined based on experiments with a 192 Ir HDR brachytherapy source. The scintillation intensities of the phosphors were 16–134 times greater than that of the commonly used organic plastic scintillator BCF-12. High signal intensities were achieved with an optimized packing density of the phosphor mixture and with a shortened fiber-optic cable. The influence of contaminating Cerenkov and fluorescence light induced in the fiber-optic cable (stem signal) was adequately suppressed by inserting between the fiber-optic cable and the photodetector a 25 nm band-pass filter centered at the emission peak. The spurious photoluminescence signal induced by the stem signal was suppressed by placing a long-pass filter between the scintillation detector volume and the fiber-optic cable. The time-dependent luminescence properties of the phosphors were quantified by measuring the non-constant scintillation during irradiation and the afterglow after the brachytherapy source had retracted. We demonstrated that a mixture of Y 2 O 3 :Eu and YVO 4 :Eu suppressed the time-dependence of the ISDs and that the time-dependence of Y 2 O 2 S:Eu and Gd 2 O 2 S:Eu introduced large measurement inaccuracies. We conclude that ISDs based on a mixture of Y 2 O 3 :Eu and YVO 4 :Eu are promising candidates for accurate and precise real-time verification technology for HDR BT that is cost effective and straightforward to manufacture. Widespread dissemination of this technology could lead to an improved understanding of error types and frequencies during BT and to improved patient safety during treatment.
- Open Access
- 1 May 2017
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 847 (1) , 012036
Inorganic scintillator detectors for real-time verification during brachytherapy
Widespread use of real-time dose measurement technology to verify brachytherapy (BT) treatments is currently limited because only few detectors exhibit the large dynamic range and signal intensities that is required to accurately report the data. Inorganic scintillator detectors (ISDs) are promising for real-time BT verification because they can exhibit large signal intensities. Luminescence properties of ISDs based on ruby, Y2O3:Eu and CsI:Tl were compared with BCF-60 plastic scintillators to determine their potential for BT verification. Measurements revealed that ISDs can exhibit signal intensities 1800 times larger than BCF-60 and that the Čerenkov and fluorescence light contamination is negligible. The favourable luminescence properties of ISDs opens the possibility to manufacture simplified detector systems that can lead to more widespread real-time verification during BT treatment deliveries.
- 1 May 2017
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 847 (1) , 012036
Open AccessInorganic scintillator detectors for real-time verification during brachytherapy
Widespread use of real-time dose measurement technology to verify brachytherapy (BT) treatments is currently limited because only few detectors exhibit the large dynamic range and signal intensities that is required to accurately report the data. Inorganic scintillator detectors (ISDs) are promising for real-time BT verification because they can exhibit large signal intensities. Luminescence properties of ISDs based on ruby, Y2O3:Eu and CsI:Tl were compared with BCF-60 plastic scintillators to determine their potential for BT verification. Measurements revealed that ISDs can exhibit signal intensities 1800 times larger than BCF-60 and that the Čerenkov and fluorescence light contamination is negligible. The favourable luminescence properties of ISDs opens the possibility to manufacture simplified detector systems that can lead to more widespread real-time verification during BT treatment deliveries.
- 14 October 2016
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 61 (21) , 7744-7764
Ruby-based inorganic scintillation detectors for192Ir brachytherapy
We tested the potential of ruby inorganic scintillation detectors (ISDs) for use in brachytherapy and investigated various unwanted luminescence properties that may compromise their accuracy. The ISDs were composed of a ruby crystal coupled to a poly(methyl methacrylate) fiber-optic cable and a charge-coupled device camera. The ISD also included a long-pass filter that was sandwiched between the ruby crystal and the fiber-optic cable. The long-pass filter prevented the Cerenkov and fluorescence background light (stem signal) induced in the fiber-optic cable from striking the ruby crystal, which generates unwanted photoluminescence rather than the desired radioluminescence. The relative contributions of the radioluminescence signal and the stem signal were quantified by exposing the ruby detectors to a high-dose-rate brachytherapy source. The photoluminescence signal was quantified by irradiating the fiber-optic cable with the detector volume shielded. Other experiments addressed time-dependent luminescence properties and compared the ISDs to commonly used organic scintillator detectors (BCF-12, BCF-60). When the brachytherapy source dwelled 0.5 cm away from the fiber-optic cable, the unwanted photoluminescence was reduced from >5% to <1% of the total signal as long as the ISD incorporated the long-pass filter. The stem signal was suppressed with a band-pass filter and was <3% as long as the source distance from the scintillator was 5% within 10 s from the onset of irradiation and after the source had retracted. The ruby-based ISDs generated signals of up to 20 times that of BCF-12-based detectors. The study presents solutions to unwanted luminescence properties of ruby-based ISDs for high-dose-rate brachytherapy. An optic filter should be sandwiched between the ruby crystal and the fiber-optic cable to suppress the photoluminescence. Furthermore, we recommend avoiding ruby crystals that exhibit significant time-dependent luminescence.
- 14 October 2016
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 61 (21) , 7744-7764
Ruby-based inorganic scintillation detectors for192Ir brachytherapy
We tested the potential of ruby inorganic scintillation detectors (ISDs) for use in brachytherapy and investigated various unwanted luminescence properties that may compromise their accuracy. The ISDs were composed of a ruby crystal coupled to a poly(methyl methacrylate) fiber-optic cable and a charge-coupled device camera. The ISD also included a long-pass filter that was sandwiched between the ruby crystal and the fiber-optic cable. The long-pass filter prevented the Cerenkov and fluorescence background light (stem signal) induced in the fiber-optic cable from striking the ruby crystal, which generates unwanted photoluminescence rather than the desired radioluminescence. The relative contributions of the radioluminescence signal and the stem signal were quantified by exposing the ruby detectors to a high-dose-rate brachytherapy source. The photoluminescence signal was quantified by irradiating the fiber-optic cable with the detector volume shielded. Other experiments addressed time-dependent luminescence properties and compared the ISDs to commonly used organic scintillator detectors (BCF-12, BCF-60). When the brachytherapy source dwelled 0.5 cm away from the fiber-optic cable, the unwanted photoluminescence was reduced from >5% to <1% of the total signal as long as the ISD incorporated the long-pass filter. The stem signal was suppressed with a band-pass filter and was <3% as long as the source distance from the scintillator was 5% within 10 s from the onset of irradiation and after the source had retracted. The ruby-based ISDs generated signals of up to 20 times that of BCF-12-based detectors. The study presents solutions to unwanted luminescence properties of ruby-based ISDs for high-dose-rate brachytherapy. An optic filter should be sandwiched between the ruby crystal and the fiber-optic cable to suppress the photoluminescence. Furthermore, we recommend avoiding ruby crystals that exhibit significant time-dependent luminescence.
- 5 December 2014
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 60 (1) , 1-14
Use of novel fibre-coupled radioluminescence and RADPOS dosimetry systems for total scatter factor measurements in small fields
A dosimetry system based on Al2O3:C radioluminescence (RL), and RADPOS, a novel 4D dosimetry system using microMOSFETs, were used to measure total scatter factors, (S(c,p))(f(clin))(det), for the CyberKnife robotic radiosugery system. New Monte Carlo calculated correction factors are presented and applied for the RL detector response for the 5, 7.5 and 10 mm collimators in order to correct for the detector geometry and increased photoelectric cross section of Al2O3:C relative to water. For comparison, measurements were also carried out using a micro MOSFET, PTW60012 diode and GAFCHROMIC(®) film (EBT and EBT2). Uncorrected (S(c,p))(f(clin))(det) were obtained by taking the ratio of the detector response for each collimator to that for the 60 mm diameter reference field. Published Monte Carlo calculated correction factors were applied to the RADPOS, microMOSFET and diode detector measurements to yield corrected field factors, Ω(f(clin),f(msr))(Q(clin),Q(msr)), following the terminology of a recent formalism introduced for small and composite field relative dosimetry. With corrections, the RL measured Ω(f(clin),f(msr))(Q(clin),Q(msr)) were 0.656 ± 0.002, 0.815 ± 0.002 and 0.865 ± 0.003 for the 5, 7.5 and 10 mm collimators, respectively. This was in good agreement with RADPOS corrected field factors of 0.650 ± 0.010, 0.816 ± 0.024 and 0.867 ± 0.010 for the 5, 7.5 and 10 mm collimators, respectively. Both RL and RADPOS total scatter factors agreed within approximately two standard deviations of the GAFCHROMIC film values (average of EBT and EBT2) of 0.640 ± 0.006, 0.806 ± 0.007 and 0.859 ± 0.09. Corrected total scatter factors for all dosimetry systems agreed within one standard deviation for collimator sizes 10-60 mm. Our study suggests that the microMOSFET/RADPOS and optical fibre-coupled RL dosimetry system are well suited for total scatter factor measurements over the entire range of field sizes, provided that appropriate correction factors are applied for the collimator diameters smaller than 10 mm.
- 5 December 2014
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 60 (1) , 1-14
Use of novel fibre-coupled radioluminescence and RADPOS dosimetry systems for total scatter factor measurements in small fields
A dosimetry system based on Al2O3:C radioluminescence (RL), and RADPOS, a novel 4D dosimetry system using microMOSFETs, were used to measure total scatter factors, (S(c,p))(f(clin))(det), for the CyberKnife robotic radiosugery system. New Monte Carlo calculated correction factors are presented and applied for the RL detector response for the 5, 7.5 and 10 mm collimators in order to correct for the detector geometry and increased photoelectric cross section of Al2O3:C relative to water. For comparison, measurements were also carried out using a micro MOSFET, PTW60012 diode and GAFCHROMIC(®) film (EBT and EBT2). Uncorrected (S(c,p))(f(clin))(det) were obtained by taking the ratio of the detector response for each collimator to that for the 60 mm diameter reference field. Published Monte Carlo calculated correction factors were applied to the RADPOS, microMOSFET and diode detector measurements to yield corrected field factors, Ω(f(clin),f(msr))(Q(clin),Q(msr)), following the terminology of a recent formalism introduced for small and composite field relative dosimetry. With corrections, the RL measured Ω(f(clin),f(msr))(Q(clin),Q(msr)) were 0.656 ± 0.002, 0.815 ± 0.002 and 0.865 ± 0.003 for the 5, 7.5 and 10 mm collimators, respectively. This was in good agreement with RADPOS corrected field factors of 0.650 ± 0.010, 0.816 ± 0.024 and 0.867 ± 0.010 for the 5, 7.5 and 10 mm collimators, respectively. Both RL and RADPOS total scatter factors agreed within approximately two standard deviations of the GAFCHROMIC film values (average of EBT and EBT2) of 0.640 ± 0.006, 0.806 ± 0.007 and 0.859 ± 0.09. Corrected total scatter factors for all dosimetry systems agreed within one standard deviation for collimator sizes 10-60 mm. Our study suggests that the microMOSFET/RADPOS and optical fibre-coupled RL dosimetry system are well suited for total scatter factor measurements over the entire range of field sizes, provided that appropriate correction factors are applied for the collimator diameters smaller than 10 mm.