  • Open Access

    An enhanced control scheme for multifunctional grid connected PV system using fuzzy and predictive direct power control

    by Boualem Boukezata, Abdelmadjid Chaoui, Jean Paul Gaubert, Oussama Boutalbi

    This paper presents a combination between a fuzzy logic control (FLC) and a predictive direct power control for multifunctional grid connected photovoltaic (PV) system, to solve the oscillation problem in the DC link voltage of the in-verter caused by the fast irradiation changing. The whole system consists of a PV system which interface a DC-AC inverter, a FLC maximum power point tracking (MPPT) algorithm has been adopted to operate the DC-DC converter at the MPP. The predictive control strategy is applied to the DC-AC inverter with FLC in its voltage control loop to improve the power exchange between the grid and the PV system. Simulation results have been verified through MATLAB/Simulink software for the purpose of giving the effectiveness of the suggested control against existed controllers.


  • Predictive current control in multifunctional grid connected inverter interfaced by PV system

    by Boualem Boukezata, Jean-Paul Gaubert, Abdelmadjid Chaoui, Mabrouk Hachemi


  • An improved fuzzy logic control MPPT based P&O method to solve fast irradiation change problem

    by Boualem Boukezata, Abdelmadjid Chaoui, Jean-Paul Gaubert, Mabrouk Hachemi

    This paper proposes a fuzzy control method for tracking maximum power point in photovoltaic (PV) power systems to solve a fast irradiation change problem. Perturb and Observe (P&O) is known as a very simple maximum power point tracking and is extensively disseminated. Fuzzy logic is also simple to investigate and provides fast dynamics. The suggested technique combines both fuzzy logic and P&O advantages. A fuzzy logic-based P&O algorithm is illustrated to identify the fault direction tracking of conventional P&O algorithm under trapezoidal irradiation change. The proposed algorithm is verified using Matlab/Simulink™ software. The robust tracking capability under rapidly increasing and decreasing irradiance is verified experimentally with a PV array emulator. Simulation and experimental results confirm that the proposed algorithm provides effective, fast, and accurate tracking compared to the conventional P&O algorithm.


  • Experimental Validation of Active Power Filtering with a Simple Robust Control

    by Abdelmadjid Chaoui, Jean-Paul Gaubert, Abdelouahab Bouafia

    This article deals with shunt active power filtering for power quality improvement with hysteresis current controllers by two methods of implementation assessed under unfavorable non-linear load and source conditions. Fully digital and simple hybrid hysteresis control strategies are tested based on a numerical integrator proportional DC bus controller combined with phase-locked loop outputs to generate current references. In two cases, reference mains currents are generated to ensure three-phase sinusoidal synchronized waveforms of the mains currents. The experimental evaluation of the robustness control in these two implementation methods is verified using a 10-kVA shunt active power filter in steady state for transitional conditions (step load, switch-on of shunt active power filter) and in the worst case of unbalanced loads (break phase) and source voltages. Several experimental results are presented and discussed to prove the robustness and excellent performance of the proposed simple hybrid technique.


  • Direct power control of three -level PWM rectifier under unbalanced and harmonically distorted grid voltage conditions

    by B. Kahia, A. Bouafia, A. Chaoui

    A modified direct power control (DPC) strategy for three-level neutral point clamped (NPC) converters under unbalanced and harmonically distorted grid voltage conditions is proposed in the paper. The modified (DPC) strategy is implemented in the stationary reference frame without the necessity of either the space vector modulation or the synchronous speed d-q transformation. A compensation method is adopted in the conventional DPC to eliminate the negative and harmonic sequence components of grid current for the purpose of obtaining the symmetrical and sinusoidal grid current. Finally, simulation results based on matlab validate the availability of the proposed DPC strategy.


  • Open Access

    Active Power Filtering Using the ZDPC Method under Unbalanced and Distorted Grid Voltage Conditions

    by Kamel Djazia, Fateh Krim, Abdelmadjid Chaoui, Mustapha Sarra

    In this paper, we propose a new Zero Direct Power Control (ZDPC) technique for active compensation of harmonics and reactive power, using shunt active power filter (SAPF), based on cancellation of instantaneous active and reactive power disturbances by comparison with their zero references. To separate harmonic and fundamental components of the line voltage and current a highly selective filter (HSF) has been used. Depending on the power errors and line voltage vector position, a switching table produces the appropriate control vectors leading to the active and reactive power variation required to reach the zero power references, even under grid voltage unbalanced and distorted conditions. The experimental validation of the proposed ZDPC has been performed. The results are compared to other recent techniques to demonstrate the superiority and feasibility of the proposed strategy.


  • Improvingthe qualityof energy in grid connected photovoltaicsystems

    by B. Boukezata, A. Chaoui, J.-P. Gaubert, M. Hachemi

    This paper proposes the effective utilization of active power filter (APF) for interconnecting the PV modules to the grid using direct power control (DPC) method. Its main feature is the capability to compensate the reactive power and harmonic currents drawn by nonlinear loads and simultaneously inject the maximum power available from the PV array into the grid. The reference current containing PV maximum power and harmonic components is developed based on direct power control via an integral-proportional (IP) controller, exploiting optimal solar energy was extracted by an algorithm of maximization MPPT is the INC-COND. The whole system (single stage converter) presents increased efficiency when compared to the conventional system. Simulation results on MATLAB/Simulink of the proposed system have been done and the obtained results prove the effectiveness of using a shunt active power filter as the interfacing unit for grid integrated renewable energy system.


  • Experimental validation of new direct power control switching table for shunt active power filter

    by Abdelmadjid Chaoui, Jean-Paul Gaubert, Abdelouahab Bouafia

    This paper deals with a new concept and analysis of direct power control (DPC) switching table for a three phase shunt active power filter (SAPF) to improve power quality. The active power reference is obtained from the VSI dc-bus voltage controlled at the required level using an integrator proportional corrector. Compared to their references, active and reactive powers are directly controlled by selecting the optimal vector using a new switching table. From the SAPF's equivalent scheme analysis the instantaneous active and reactive powers (IARP) variations are obtained. The new predefined switching table is designed based on comparative study and voltage source inverter (VSI) switching vectors effect on the total IARP variations. The main advantages of this control technique are that it provides a sinusoidal source current and unity power factor with no need of linear current controllers and coordinates transformations or modulators. Extensive simulation and experimental results, obtained from steady and transient states, prove the excellent performance and verify the validity and effectiveness of the proposed power control for improving the power quality.


  • High performance direct power control of three-phase PWM boost rectifier under different supply voltage conditions

    by Abdelouahab Bouafia, Jean-Paul Gaubert, Abdelmadjid Chaoui

    Conventional direct power control (DPC) technique is a simple and efficient control strategy for three-phase PWM rectifier. However, its performance is deteriorated when the converter is supplied by unbalanced or distorted grid voltages. This paper presents the design and implementation of a new DPC scheme based on disturbance rejection principle to achieve sinusoidal input currents operation of three-phase PWM rectifier under different supply voltage conditions. In the proposed DPC, instantaneous active and reactive powers provided by harmonic component of input currents are chosen as controlled variables. Both controlled power reference are given from the outside of the controller and are set to zero to achieve full rejection of any grid disturbance. Moreover, the control strategy minimizes a cost function to select the optimum converter voltage vector allowing the best tracking of controlled powers. Finally, the effectiveness of the proposed DPC scheme is verified through several simulation and experimental tests. Results have proven an excellent performance and good robustness of the proposed DPC under different supply voltage conditions, compared to lookup table-based conventional DPC.


  • Control strategy of a transformerless three phase shunt hybrid power filter using a robust PLL

    by Mustapha Sarra, Jean-Paul Gaubert, Abdelmadjid Chaoui, Fateh Krim

    This paper deals with a shunt hybrid active power filter (SHAPF) based on a advanced control algorithm consisting of synchronous reference frame (SRF) rotating at fundamental angular speed using a Multi-Variable Filters (MFV) based robust PLL to determine the reference current for the SHAPF in order to improve the power quality and compensate reactive power required by nonlinear load. The SHAPF is formed by a single 7th tuned LC filter per phase and a small-rated three-phase active filter, which are directly connected in series without any matching transformer. The required rating of the active filter is much smaller than that of a conventional standalone active filter be. All simulations are performed by using Matlab-Simulink Power System Blockset and validated with an experimental test bench developed in the LIAS laboratory, University of Poitiers. Various simulation and experimental results of the proposed control algorithm are presented under steady state and transient conditions to confirm his validity and effectiveness.