Abdelouahab Bouafia
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Abdelouahab Bouafia has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Fateh Krim
University of Setif-1
9 shared publications Jean-Paul Gaubert
Laboratoire d'Informatique et d'Automatique pour les Systèmes (LIAS), ENSIP, université de Poitiers, France
7 shared publications- Abdelmadjid Chaoui
Laboratoire d'Electronique de Puissance et Commande Industrielle (LEPCI), Université de Sétif, Algérie
6 shared publications - Jean-Paul Gaubert
University of Poitiers
4 shared publications L. Rahmani
Laboratory of Power Electronics and Industrial Control, Department of Electrical Engineering, University of Setif, Algeria
2 shared publications- B. Kahia
Department of Electrotechnics, University of Setif 1, Algeria
1 shared publication
Latest Publications
- 21 May 2016
- Published by Taylor & Francis in Electric Power Components and Systems
- Vol. 44 (10) , 1-14
Experimental Validation of Active Power Filtering with a Simple Robust Control
This article deals with shunt active power filtering for power quality improvement with hysteresis current controllers by two methods of implementation assessed under unfavorable non-linear load and source conditions. Fully digital and simple hybrid hysteresis control strategies are tested based on a numerical integrator proportional DC bus controller combined with phase-locked loop outputs to generate current references. In two cases, reference mains currents are generated to ensure three-phase sinusoidal synchronized waveforms of the mains currents. The experimental evaluation of the robustness control in these two implementation methods is verified using a 10-kVA shunt active power filter in steady state for transitional conditions (step load, switch-on of shunt active power filter) and in the worst case of unbalanced loads (break phase) and source voltages. Several experimental results are presented and discussed to prove the robustness and excellent performance of the proposed simple hybrid technique.
- 21 May 2016
- Published by Taylor & Francis in Electric Power Components and Systems
- Vol. 44 (10) , 1-14
Experimental Validation of Active Power Filtering with a Simple Robust Control
This article deals with shunt active power filtering for power quality improvement with hysteresis current controllers by two methods of implementation assessed under unfavorable non-linear load and source conditions. Fully digital and simple hybrid hysteresis control strategies are tested based on a numerical integrator proportional DC bus controller combined with phase-locked loop outputs to generate current references. In two cases, reference mains currents are generated to ensure three-phase sinusoidal synchronized waveforms of the mains currents. The experimental evaluation of the robustness control in these two implementation methods is verified using a 10-kVA shunt active power filter in steady state for transitional conditions (step load, switch-on of shunt active power filter) and in the worst case of unbalanced loads (break phase) and source voltages. Several experimental results are presented and discussed to prove the robustness and excellent performance of the proposed simple hybrid technique.
- 1 December 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Direct power control of three -level PWM rectifier under unbalanced and harmonically distorted grid voltage conditions
A modified direct power control (DPC) strategy for three-level neutral point clamped (NPC) converters under unbalanced and harmonically distorted grid voltage conditions is proposed in the paper. The modified (DPC) strategy is implemented in the stationary reference frame without the necessity of either the space vector modulation or the synchronous speed d-q transformation. A compensation method is adopted in the conventional DPC to eliminate the negative and harmonic sequence components of grid current for the purpose of obtaining the symmetrical and sinusoidal grid current. Finally, simulation results based on matlab validate the availability of the proposed DPC strategy.
- 1 December 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Direct power control of three -level PWM rectifier under unbalanced and harmonically distorted grid voltage conditions
A modified direct power control (DPC) strategy for three-level neutral point clamped (NPC) converters under unbalanced and harmonically distorted grid voltage conditions is proposed in the paper. The modified (DPC) strategy is implemented in the stationary reference frame without the necessity of either the space vector modulation or the synchronous speed d-q transformation. A compensation method is adopted in the conventional DPC to eliminate the negative and harmonic sequence components of grid current for the purpose of obtaining the symmetrical and sinusoidal grid current. Finally, simulation results based on matlab validate the availability of the proposed DPC strategy.
- 1 September 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-11
Experimental validation of new direct power control switching table for shunt active power filter
This paper deals with a new concept and analysis of direct power control (DPC) switching table for a three phase shunt active power filter (SAPF) to improve power quality. The active power reference is obtained from the VSI dc-bus voltage controlled at the required level using an integrator proportional corrector. Compared to their references, active and reactive powers are directly controlled by selecting the optimal vector using a new switching table. From the SAPF's equivalent scheme analysis the instantaneous active and reactive powers (IARP) variations are obtained. The new predefined switching table is designed based on comparative study and voltage source inverter (VSI) switching vectors effect on the total IARP variations. The main advantages of this control technique are that it provides a sinusoidal source current and unity power factor with no need of linear current controllers and coordinates transformations or modulators. Extensive simulation and experimental results, obtained from steady and transient states, prove the excellent performance and verify the validity and effectiveness of the proposed power control for improving the power quality.
- 1 September 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-11
Experimental validation of new direct power control switching table for shunt active power filter
This paper deals with a new concept and analysis of direct power control (DPC) switching table for a three phase shunt active power filter (SAPF) to improve power quality. The active power reference is obtained from the VSI dc-bus voltage controlled at the required level using an integrator proportional corrector. Compared to their references, active and reactive powers are directly controlled by selecting the optimal vector using a new switching table. From the SAPF's equivalent scheme analysis the instantaneous active and reactive powers (IARP) variations are obtained. The new predefined switching table is designed based on comparative study and voltage source inverter (VSI) switching vectors effect on the total IARP variations. The main advantages of this control technique are that it provides a sinusoidal source current and unity power factor with no need of linear current controllers and coordinates transformations or modulators. Extensive simulation and experimental results, obtained from steady and transient states, prove the excellent performance and verify the validity and effectiveness of the proposed power control for improving the power quality.
- 1 September 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-8
High performance direct power control of three-phase PWM boost rectifier under different supply voltage conditions
Conventional direct power control (DPC) technique is a simple and efficient control strategy for three-phase PWM rectifier. However, its performance is deteriorated when the converter is supplied by unbalanced or distorted grid voltages. This paper presents the design and implementation of a new DPC scheme based on disturbance rejection principle to achieve sinusoidal input currents operation of three-phase PWM rectifier under different supply voltage conditions. In the proposed DPC, instantaneous active and reactive powers provided by harmonic component of input currents are chosen as controlled variables. Both controlled power reference are given from the outside of the controller and are set to zero to achieve full rejection of any grid disturbance. Moreover, the control strategy minimizes a cost function to select the optimum converter voltage vector allowing the best tracking of controlled powers. Finally, the effectiveness of the proposed DPC scheme is verified through several simulation and experimental tests. Results have proven an excellent performance and good robustness of the proposed DPC under different supply voltage conditions, compared to lookup table-based conventional DPC.
- 1 September 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-8
High performance direct power control of three-phase PWM boost rectifier under different supply voltage conditions
Conventional direct power control (DPC) technique is a simple and efficient control strategy for three-phase PWM rectifier. However, its performance is deteriorated when the converter is supplied by unbalanced or distorted grid voltages. This paper presents the design and implementation of a new DPC scheme based on disturbance rejection principle to achieve sinusoidal input currents operation of three-phase PWM rectifier under different supply voltage conditions. In the proposed DPC, instantaneous active and reactive powers provided by harmonic component of input currents are chosen as controlled variables. Both controlled power reference are given from the outside of the controller and are set to zero to achieve full rejection of any grid disturbance. Moreover, the control strategy minimizes a cost function to select the optimum converter voltage vector allowing the best tracking of controlled powers. Finally, the effectiveness of the proposed DPC scheme is verified through several simulation and experimental tests. Results have proven an excellent performance and good robustness of the proposed DPC under different supply voltage conditions, compared to lookup table-based conventional DPC.
- 1 October 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 1553572X,p. 1286-1294
Direct power control concept and analysis for three phase shunt active power filter
This paper deals with the concept and analysis of direct power control (DPC) for a three phase shunt active power filter (SAPF). From the topology of the SAPF and its equivalent scheme a new predefined switching table is designed by analyzing the voltage source inverter (VSI) switching vectors effect on the total derivatives of instantaneous and reactive power. To maintain the VSI dc-bus voltage at the required level an IP controller is used to obtain the active power control. The active and reactive powers are directly controlled by selecting the optimal switching state. The main advantages of this method are that it provides a sinusoidal source current and unity power factor with no need of linear current controllers and coordinates transformations or modulators. Extensive simulation and experimental results obtained from steady and transient states have proven the excellent performance and verify the validity and effectiveness of the proposed power control scheme.
- 1 October 2012
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 1553572X,p. 1286-1294
Direct power control concept and analysis for three phase shunt active power filter
This paper deals with the concept and analysis of direct power control (DPC) for a three phase shunt active power filter (SAPF). From the topology of the SAPF and its equivalent scheme a new predefined switching table is designed by analyzing the voltage source inverter (VSI) switching vectors effect on the total derivatives of instantaneous and reactive power. To maintain the VSI dc-bus voltage at the required level an IP controller is used to obtain the active power control. The active and reactive powers are directly controlled by selecting the optimal switching state. The main advantages of this method are that it provides a sinusoidal source current and unity power factor with no need of linear current controllers and coordinates transformations or modulators. Extensive simulation and experimental results obtained from steady and transient states have proven the excellent performance and verify the validity and effectiveness of the proposed power control scheme.
- 1 December 2010
- Published by Elsevier in Energy Conversion and Management
- Vol. 51 (12) , 2473-2481
Design and implementation of predictive current control of three-phase PWM rectifier using space-vector modulation (SVM)
- 1 December 2010
- Published by Elsevier in Energy Conversion and Management
- Vol. 51 (12) , 2473-2481
Design and implementation of predictive current control of three-phase PWM rectifier using space-vector modulation (SVM)
- Top Cited Papers
- 18 August 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 25 (1) , 228-236
Predictive Direct Power Control of Three-Phase Pulsewidth Modulation (PWM) Rectifier Using Space-Vector Modulation (SVM)
In this paper, we present a direct power control (DPC) of three-phase pulsewidth modulation rectifier with constant switching frequency using space-vector modulation (SVM). The developed DPC scheme is based on the predictive control strategy to achieve direct control of instantaneous active and reactive power of the converter. For this purpose, at the beginning of each switching period, the required rectifier average voltage vector allowing the cancellation of active and reactive power tracking errors, at the end of the switching period, is calculated by means of predictive control algorithm in the sense of deadbeat control. The main advantages of the proposed control, compared to the works published in this subject, are that no need to use predefined switching table and voltage vector or virtual flux position, PI-based active and reactive power control loops are not necessary and constant-switching frequency. The proposed predictive direct power control was tested both in simulations and experimentally and compared with DPC using switching table. Results have proved excellent performance, and verify the validity of the proposed DPC scheme, which is much better than conventional DPC using switching table.
- 18 August 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 25 (1) , 228-236
Top Cited PapersPredictive Direct Power Control of Three-Phase Pulsewidth Modulation (PWM) Rectifier Using Space-Vector Modulation (SVM)
In this paper, we present a direct power control (DPC) of three-phase pulsewidth modulation rectifier with constant switching frequency using space-vector modulation (SVM). The developed DPC scheme is based on the predictive control strategy to achieve direct control of instantaneous active and reactive power of the converter. For this purpose, at the beginning of each switching period, the required rectifier average voltage vector allowing the cancellation of active and reactive power tracking errors, at the end of the switching period, is calculated by means of predictive control algorithm in the sense of deadbeat control. The main advantages of the proposed control, compared to the works published in this subject, are that no need to use predefined switching table and voltage vector or virtual flux position, PI-based active and reactive power control loops are not necessary and constant-switching frequency. The proposed predictive direct power control was tested both in simulations and experimentally and compared with DPC using switching table. Results have proved excellent performance, and verify the validity of the proposed DPC scheme, which is much better than conventional DPC using switching table.
- 10 February 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 56 (6) , 1984-1992
Fuzzy-Logic-Based Switching State Selection for Direct Power Control of Three-Phase PWM Rectifier
This paper proposes a novel and simple direct power control (DPC) scheme of a three-phase pulsewidth-modulated rectifier without the use of a predefined switching table. The converter switching state selection is based on fuzzy logic rules, using the instantaneous active and reactive power tracking errors as fuzzy logic variables. The basic idea of fuzzy rules synthesis is based on the knowledge of the instantaneous variation of active and reactive power. According to the input fuzzy variables and in a specific moment, the best switching state of the converter is chosen to restrict the instantaneous active and reactive power tracking errors simultaneously, for maintaining the DC-bus voltage close to the reference value and guarantying the unity-power-factor operation. The main advantages of the proposed DPC scheme, compared to the classical one, are that it is not necessary to use hysteresis comparators, and smooth control of active and reactive power is obtained during all sectors. Finally, the developed DPC was tested both in simulations and experimentally, and illustrative results are presented here. Results have proven excellent performance, and verify the validity of the proposed DPC scheme which is much better than the classical DPC.
- 10 February 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 56 (6) , 1984-1992
Fuzzy-Logic-Based Switching State Selection for Direct Power Control of Three-Phase PWM Rectifier
This paper proposes a novel and simple direct power control (DPC) scheme of a three-phase pulsewidth-modulated rectifier without the use of a predefined switching table. The converter switching state selection is based on fuzzy logic rules, using the instantaneous active and reactive power tracking errors as fuzzy logic variables. The basic idea of fuzzy rules synthesis is based on the knowledge of the instantaneous variation of active and reactive power. According to the input fuzzy variables and in a specific moment, the best switching state of the converter is chosen to restrict the instantaneous active and reactive power tracking errors simultaneously, for maintaining the DC-bus voltage close to the reference value and guarantying the unity-power-factor operation. The main advantages of the proposed DPC scheme, compared to the classical one, are that it is not necessary to use hysteresis comparators, and smooth control of active and reactive power is obtained during all sectors. Finally, the developed DPC was tested both in simulations and experimentally, and illustrative results are presented here. Results have proven excellent performance, and verify the validity of the proposed DPC scheme which is much better than the classical DPC.
- 1 January 2009
- Published by Elsevier in Energy Conversion and Management
- Vol. 50 (1) , 6-13
Design and implementation of high performance direct power control of three-phase PWM rectifier, via fuzzy and PI controller for output voltage regulation
- 1 January 2009
- Published by Elsevier in Energy Conversion and Management
- Vol. 50 (1) , 6-13
Design and implementation of high performance direct power control of three-phase PWM rectifier, via fuzzy and PI controller for output voltage regulation
- 1 September 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 703-709
Analysis and design of new switching table for direct power control of three-phase PWM rectifier
In this paper, a new switching table is presented for direct power control (DPC) of three-phase PWM rectifiers. The proposed switching table is synthesized by analyzing the instantaneous active and reactive power correction. For this reason, and based on the sign and magnitude of the change in instantaneous active and reactive power, the best converter switching state allowing smooth control of active and reactive power simultaneously during each sector is selected. The dc-bus voltage is maintained at the required level by controlling active power to be constant and equal to its reference value. The unity power factor (UPF) operation of the converter is achieved by maintaining the reactive power zero during all sectors. Simulation and experimental results have proven that the proposed DPC is much better than the classical one and verify the validity and performance of the presented DPC.
- 1 September 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 703-709
Analysis and design of new switching table for direct power control of three-phase PWM rectifier
In this paper, a new switching table is presented for direct power control (DPC) of three-phase PWM rectifiers. The proposed switching table is synthesized by analyzing the instantaneous active and reactive power correction. For this reason, and based on the sign and magnitude of the change in instantaneous active and reactive power, the best converter switching state allowing smooth control of active and reactive power simultaneously during each sector is selected. The dc-bus voltage is maintained at the required level by controlling active power to be constant and equal to its reference value. The unity power factor (UPF) operation of the converter is achieved by maintaining the reactive power zero during all sectors. Simulation and experimental results have proven that the proposed DPC is much better than the classical one and verify the validity and performance of the presented DPC.