Si-Huei Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Si-Huei Lee has a total of 44 co-authors. Here are the top co-authors by number of shared publications:
- Bor-Shing Lin
Department of Computer Science and Information Engineering, National Taipei University, New Taipei City, Taiwan
4 shared publications - Shih-Ching Yeh
National Central University
3 shared publications - Chun-Ta Chen
Department of Mechatronic Engineering, National Taiwan Normal University, 162, Section 1, He-ping East Road, Taipei 106, Taiwan
2 shared publications - I-Jung Lee
Department of Computer Science and Information Engineering, National Taipei University, New Taipei City, Taiwan
2 shared publications - Lo-Ping Yu
Attending Physician of Department of Physical Medicine and Rehabilitation, Taipei Veterans General Hospital, 201, Section 2, Shipai Road, Taipei 106, Taiwan
2 shared publications Shih-Ching Yeh
Department of Computer Science and Information Engineering, National Central University, Taoyuan, Taiwan
2 shared publications
Latest Publications
- Open Access
- 20 October 2026
- Published by MDPI AG in Bioengineering
- Vol. 13 (10) , 1226
Sit-to-Stand Assistance for Patients with Parkinson’s Disease Using a Lower-Limb Exoskeleton Robot
Sit-to-stand (STS) transfer is fundamental to many activities of daily living, but it is difficult for individuals with motor dysfunction or impairment. This study presents an observer-based impedance-control framework for a lower-limb exoskeleton robot to assist STS transfer. To account for external disturbances, including the wearer’s joint torques and model uncertainties, a nonlinear disturbance observer (NDO) is used to estimate the lumped disturbance. An impedance-control strategy based on adaptive fuzzy sliding mode control (AFSMC) is then used to regulate the human exoskeleton system by compensating for these unknown terms. STS trials were conducted in one healthy participant and three participants with Parkinson’s disease (PD), with and without exoskeleton assistance, to evaluate the proposed system. Across ten trials in the healthy participant, O-AFSMC had the lowest mean hip/knee RMSE (2.1247°/2.9375°). In PD participants, assistance reduced CoP and CoM excursion at the 3-s STS condition in each individual; in the H-Y stage-2 participant, CoP excursion decreased from 25.39 to 15.18 cm and CoM excursion from 17.83 to 14.21 cm. These pilot findings support the feasibility of STS assistance with a lower-limb exoskeleton robot.
- 20 October 2026
- Published by MDPI AG in Bioengineering
- Vol. 13 (10) , 1226
Open AccessSit-to-Stand Assistance for Patients with Parkinson’s Disease Using a Lower-Limb Exoskeleton Robot
Sit-to-stand (STS) transfer is fundamental to many activities of daily living, but it is difficult for individuals with motor dysfunction or impairment. This study presents an observer-based impedance-control framework for a lower-limb exoskeleton robot to assist STS transfer. To account for external disturbances, including the wearer’s joint torques and model uncertainties, a nonlinear disturbance observer (NDO) is used to estimate the lumped disturbance. An impedance-control strategy based on adaptive fuzzy sliding mode control (AFSMC) is then used to regulate the human exoskeleton system by compensating for these unknown terms. STS trials were conducted in one healthy participant and three participants with Parkinson’s disease (PD), with and without exoskeleton assistance, to evaluate the proposed system. Across ten trials in the healthy participant, O-AFSMC had the lowest mean hip/knee RMSE (2.1247°/2.9375°). In PD participants, assistance reduced CoP and CoM excursion at the 3-s STS condition in each individual; in the H-Y stage-2 participant, CoP excursion decreased from 25.39 to 15.18 cm and CoM excursion from 17.83 to 14.21 cm. These pilot findings support the feasibility of STS assistance with a lower-limb exoskeleton robot.
- 1 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Human-Machine Systems
- Vol. 56 (3) , 488-497
Smartphone-Based Telerehabilitation for Low Back Pain: A Randomized Controlled Trial on Pain, Disability, Fear-Avoidance, and Trunk Muscle Endurance
Low back pain (LBP) is a widespread global health problem associated with a significant economic burden. Compared with traditional treatment, telerehabilitation may enhance exercise adherence and execution. This randomized controlled trial evaluated the efficacy of a smartphone-based mHealth platform for telerehabilitation (SMPT) in individuals with LBP. Participants were randomly assigned to either the SMPT group (n = 23) or a control group (n = 19) for a 12-week home-based program. Outcomes included pain assessed by the visual analogue scale (VAS), disability by the Roland–Morris disability questionnaire (RMDQ), fear-avoidance beliefs by the fear-avoidance beliefs questionnaire (FABQ), and trunk endurance tests. After the 12-week intervention, the SMPT group showed significantly lower postintervention VAS scores compared with the control group (19.0 [11.5–31.5] vs. 27.0 [20.0–45.5]; p = 0.036; r = 0.35). A greater median reduction in pain intensity was observed in the SMPT group (−29.0 [−44.5 to −17.5]) than in the control group (−11.0 [−33.5 to −4.0]) (p = 0.044; Hodges–Lehmann Δ = 15.0 [95% CI −60.1, 64.3]). Within the SMPT group, disability and fear-avoidance outcomes also improved significantly, with RMDQ scores decreasing from 7.0 [5.0–9.5] to 4.0 [3.0–6.5] (p = 0.013) and FABQ total scores from 34.0 [27.5–41.5] to 27.0 [19.5–34.5] (p = 0.005). These results suggest that the SMPT is effective in reducing pain, disability, and fear-avoidance beliefs, while improving trunk endurance. The SMPT may serve as a practical adjunct to conventional rehabilitation in patients with LBP.
- 1 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Human-Machine Systems
- Vol. 56 (3) , 488-497
Smartphone-Based Telerehabilitation for Low Back Pain: A Randomized Controlled Trial on Pain, Disability, Fear-Avoidance, and Trunk Muscle Endurance
Low back pain (LBP) is a widespread global health problem associated with a significant economic burden. Compared with traditional treatment, telerehabilitation may enhance exercise adherence and execution. This randomized controlled trial evaluated the efficacy of a smartphone-based mHealth platform for telerehabilitation (SMPT) in individuals with LBP. Participants were randomly assigned to either the SMPT group (n = 23) or a control group (n = 19) for a 12-week home-based program. Outcomes included pain assessed by the visual analogue scale (VAS), disability by the Roland–Morris disability questionnaire (RMDQ), fear-avoidance beliefs by the fear-avoidance beliefs questionnaire (FABQ), and trunk endurance tests. After the 12-week intervention, the SMPT group showed significantly lower postintervention VAS scores compared with the control group (19.0 [11.5–31.5] vs. 27.0 [20.0–45.5]; p = 0.036; r = 0.35). A greater median reduction in pain intensity was observed in the SMPT group (−29.0 [−44.5 to −17.5]) than in the control group (−11.0 [−33.5 to −4.0]) (p = 0.044; Hodges–Lehmann Δ = 15.0 [95% CI −60.1, 64.3]). Within the SMPT group, disability and fear-avoidance outcomes also improved significantly, with RMDQ scores decreasing from 7.0 [5.0–9.5] to 4.0 [3.0–6.5] (p = 0.013) and FABQ total scores from 34.0 [27.5–41.5] to 27.0 [19.5–34.5] (p = 0.005). These results suggest that the SMPT is effective in reducing pain, disability, and fear-avoidance beliefs, while improving trunk endurance. The SMPT may serve as a practical adjunct to conventional rehabilitation in patients with LBP.
- Open Access
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Translational Engineering in Health and Medicine
- Vol. 14, 445-459
A Context-Aware Webcam-Based AIoMT Framework for Translational Frailty Screening Using Skeleton–Environment Fusion
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Translational Engineering in Health and Medicine
- Vol. 14, 445-459
Open AccessA Context-Aware Webcam-Based AIoMT Framework for Translational Frailty Screening Using Skeleton–Environment Fusion
- Open Access
Assisting Standing Balance Recovery for Parkinson’s Patients with a Lower-Extremity Exoskeleton Robot
Parkinson’s disease (PD) is a neurodegenerative disorder and always results in balance loss. Although studies in lower-extremity exoskeleton robots are ample, applications with a lower-extremity exoskeleton robot for PD patients are still challenging. This paper aims to develop an effective assistive control for PD patients with a lower-extremity exoskeleton robot to maintain standing balance while being subjected to external disturbances. When an external force is applied to participants to force them to lose balance, the hip strategy for balance recovery based on the zero moment point (ZMP) metrics is used to generate a reference trajectory of the hip joint, and then, a model-free linear extended state observer (LESO)-based fuzzy sliding mode control (FSMC) is synthesized to regulate the human body to recover balance. Balance recovery trials for healthy individuals and PD patients with and without exoskeleton assistance were conducted to evaluate the performance of the proposed exoskeleton robot and balance recovery strategy. Our experiments demonstrated the potential effectiveness of the proposed exoskeleton robot and controller for standing balance recovery control in PD patients.
Open AccessAssisting Standing Balance Recovery for Parkinson’s Patients with a Lower-Extremity Exoskeleton Robot
Parkinson’s disease (PD) is a neurodegenerative disorder and always results in balance loss. Although studies in lower-extremity exoskeleton robots are ample, applications with a lower-extremity exoskeleton robot for PD patients are still challenging. This paper aims to develop an effective assistive control for PD patients with a lower-extremity exoskeleton robot to maintain standing balance while being subjected to external disturbances. When an external force is applied to participants to force them to lose balance, the hip strategy for balance recovery based on the zero moment point (ZMP) metrics is used to generate a reference trajectory of the hip joint, and then, a model-free linear extended state observer (LESO)-based fuzzy sliding mode control (FSMC) is synthesized to regulate the human body to recover balance. Balance recovery trials for healthy individuals and PD patients with and without exoskeleton assistance were conducted to evaluate the performance of the proposed exoskeleton robot and balance recovery strategy. Our experiments demonstrated the potential effectiveness of the proposed exoskeleton robot and controller for standing balance recovery control in PD patients.
- Open Access
Design of a Multi-Sensor System for Exploring the Relation between Finger Spasticity and Voluntary Movement in Patients with Stroke
A novel wearable multi-sensor data glove system is developed to explore the relation between finger spasticity and voluntary movement in patients with stroke. Many stroke patients suffer from finger spasticity, which is detrimental to their manual dexterity. Diagnosing and assessing the degrees of spasticity require neurological testing performed by trained professionals to estimate finger spasticity scores via the modified Ashworth scale (MAS). The proposed system offers an objective, quantitative solution to assess the finger spasticity of patients with stroke and complements the manual neurological test. In this work, the hardware and software components of this system are described. By requiring patients to perform five designated tasks, biomechanical measurements including linear and angular speed, acceleration, and pressure at every finger joint and upper limb are recorded, making up more than 1000 features for each task. We conducted a preliminary clinical test with 14 subjects using this system. Statistical analysis is performed on the acquired measurements to identify a small subset of features that are most likely to discriminate a healthy patient from patients suffering from finger spasticity. This encouraging result validates the feasibility of this proposed system to quantitatively and objectively assess finger spasticity.
Open AccessDesign of a Multi-Sensor System for Exploring the Relation between Finger Spasticity and Voluntary Movement in Patients with Stroke
A novel wearable multi-sensor data glove system is developed to explore the relation between finger spasticity and voluntary movement in patients with stroke. Many stroke patients suffer from finger spasticity, which is detrimental to their manual dexterity. Diagnosing and assessing the degrees of spasticity require neurological testing performed by trained professionals to estimate finger spasticity scores via the modified Ashworth scale (MAS). The proposed system offers an objective, quantitative solution to assess the finger spasticity of patients with stroke and complements the manual neurological test. In this work, the hardware and software components of this system are described. By requiring patients to perform five designated tasks, biomechanical measurements including linear and angular speed, acceleration, and pressure at every finger joint and upper limb are recorded, making up more than 1000 features for each task. We conducted a preliminary clinical test with 14 subjects using this system. Statistical analysis is performed on the acquired measurements to identify a small subset of features that are most likely to discriminate a healthy patient from patients suffering from finger spasticity. This encouraging result validates the feasibility of this proposed system to quantitatively and objectively assess finger spasticity.
- Open Access
- 5 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 30 (15344320) , 2682-2691
Development of a Smartphone-Based mHealth Platform for Telerehabilitation
Telerehabilitation is becoming increasingly valuable as a method for expanding medical services. The smartphone-based mHealth platform (SMPT) has been developed to provide high-quality remote rehabilitation through a smartphone and inertial measurement units. The SMPT uses smartphone as a main platform with connection to medical backend server to provide telerehabilitation. Patients would be referred to therapists to receive a tutorial of exercise technique prior to conducting their home exercise. Once patients begin their home exercises, they can report any problems instantly through the SMPT. The medical staff can adjust the exercise program according to patient feedback and the data collected by the SMPT. After completing the exercise program, patients visit their clinician for re-evaluation. A Service User Technology Acceptability Questionnaire from both medical professional and public perspective revealed a high level of agreement on enhanced care, increased accessibility, and satisfaction and a moderate level of agreement on the use of this platform as a substitute for traditional rehabilitation. Concerns about privacy and discomfort were low in the medical professional and public groups. Concerns about care personnel were also significantly different between the two groups. The SMPT is a promising system for providing telerehabilitation as an adjunct to traditional rehabilitation, which may result in improved outcomes compared with those achieved when using traditional rehabilitation alone.
- 5 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Neural Systems and Rehabilitation Engineering
- Vol. 30 (15344320) , 2682-2691
Open AccessDevelopment of a Smartphone-Based mHealth Platform for Telerehabilitation
Telerehabilitation is becoming increasingly valuable as a method for expanding medical services. The smartphone-based mHealth platform (SMPT) has been developed to provide high-quality remote rehabilitation through a smartphone and inertial measurement units. The SMPT uses smartphone as a main platform with connection to medical backend server to provide telerehabilitation. Patients would be referred to therapists to receive a tutorial of exercise technique prior to conducting their home exercise. Once patients begin their home exercises, they can report any problems instantly through the SMPT. The medical staff can adjust the exercise program according to patient feedback and the data collected by the SMPT. After completing the exercise program, patients visit their clinician for re-evaluation. A Service User Technology Acceptability Questionnaire from both medical professional and public perspective revealed a high level of agreement on enhanced care, increased accessibility, and satisfaction and a moderate level of agreement on the use of this platform as a substitute for traditional rehabilitation. Concerns about privacy and discomfort were low in the medical professional and public groups. Concerns about care personnel were also significantly different between the two groups. The SMPT is a promising system for providing telerehabilitation as an adjunct to traditional rehabilitation, which may result in improved outcomes compared with those achieved when using traditional rehabilitation alone.
- Open Access
Assessment System for Predicting Maximal Safe Range for Heel Height by Using Force-Sensing Resistor Sensors and Regression Models
Women often wear high-heeled shoes for professional or esthetic reasons. However, high-heeled shoes can cause discomfort and injury and can change the body’s center of gravity when maintaining balance. This study developed an assessment system for predicting the maximal safe range for heel height by recording the plantar pressure of participants’ feet by using force-sensing resistor (FSR) sensors and conducting analyses using regression models. Specifically, 100 young healthy women stood on an adjustable platform while physicians estimated the maximal safe height of high-heeled shoes. The collected FSR data combined with and without personal features were analyzed using regression models. The experimental results showed that the regression model based on the pressure data for the right foot had better predictive power than that based on data for the left foot, regardless of the module. The model with two heights had higher predictive power than that with a single height. Furthermore, adding personal features under the condition of two heights afforded the best predictive effect. These results can help wearers choose maximal safe high-heeled shoes to reduce injuries to the bones and lower limbs.
Open AccessAssessment System for Predicting Maximal Safe Range for Heel Height by Using Force-Sensing Resistor Sensors and Regression Models
Women often wear high-heeled shoes for professional or esthetic reasons. However, high-heeled shoes can cause discomfort and injury and can change the body’s center of gravity when maintaining balance. This study developed an assessment system for predicting the maximal safe range for heel height by recording the plantar pressure of participants’ feet by using force-sensing resistor (FSR) sensors and conducting analyses using regression models. Specifically, 100 young healthy women stood on an adjustable platform while physicians estimated the maximal safe height of high-heeled shoes. The collected FSR data combined with and without personal features were analyzed using regression models. The experimental results showed that the regression model based on the pressure data for the right foot had better predictive power than that based on data for the left foot, regardless of the module. The model with two heights had higher predictive power than that with a single height. Furthermore, adding personal features under the condition of two heights afforded the best predictive effect. These results can help wearers choose maximal safe high-heeled shoes to reduce injuries to the bones and lower limbs.
- 20 June 2021
- Published by Springer Nature in International Journal of Fuzzy Systems
- Vol. 23 (7) , 1919-1933
Evaluating Power Rehabilitation Actions Using a Fuzzy Inference Method
The older population faces a high probability of experiencing age-related problems, such as osteoporosis, immobility, gait disturbances, stroke, Parkinson’s disease, and cognitive behavioral functional difficulties. Such problems negatively affect their lives. Thus, access to long-term care is a critical issue for older adults. In response to the aforementioned serious health issues, society must strive to provide a supportive and effective rehabilitation environment for older adults. This study designed an intelligent active and passive limb rehabilitation system to track and quantify the effectiveness of joint movements in patients automatically. The proposed method uses a camera and PoseNet to capture key feature information regarding human skeleton nodes and identify rehabilitation actions through joint movements. In addition, to solve the problem of joint occlusion during joint angle measurement, the designed system is equipped with a self-designed inertial measurement unit with GY-85 nine-axis sensors, which are mounted on the occluding part of the joints. A fuzzy inference system was developed to provide scores, suggestions, and encouragement for each rehabilitation session. This system also provides an interactive interface for users to monitor each rehabilitation session and examine whether rehabilitation is performed accurately.
- 20 June 2021
- Published by Springer Nature in International Journal of Fuzzy Systems
- Vol. 23 (7) , 1919-1933
Evaluating Power Rehabilitation Actions Using a Fuzzy Inference Method
The older population faces a high probability of experiencing age-related problems, such as osteoporosis, immobility, gait disturbances, stroke, Parkinson’s disease, and cognitive behavioral functional difficulties. Such problems negatively affect their lives. Thus, access to long-term care is a critical issue for older adults. In response to the aforementioned serious health issues, society must strive to provide a supportive and effective rehabilitation environment for older adults. This study designed an intelligent active and passive limb rehabilitation system to track and quantify the effectiveness of joint movements in patients automatically. The proposed method uses a camera and PoseNet to capture key feature information regarding human skeleton nodes and identify rehabilitation actions through joint movements. In addition, to solve the problem of joint occlusion during joint angle measurement, the designed system is equipped with a self-designed inertial measurement unit with GY-85 nine-axis sensors, which are mounted on the occluding part of the joints. A fuzzy inference system was developed to provide scores, suggestions, and encouragement for each rehabilitation session. This system also provides an interactive interface for users to monitor each rehabilitation session and examine whether rehabilitation is performed accurately.
- Open Access
- 16 June 2020
- Published by Frontiers Media SA in Frontiers in Neuroscience
- Vol. 14, 548
Synchrony Between Default-Mode and Sensorimotor Networks Facilitates Motor Function in Stroke Rehabilitation: A Pilot fMRI Study
Stroke is the most common cause of complex disability in Taiwan. After stroke onset, persistent physical practice or exercise in the rehabilitation procedure reorganizes neural assembly for reducing motor deficits, known as neuroplasticity. Neuroimaging literature showed rehabilitative effects specific to the brain networks of the sensorimotor network (SMN) and default-mode network (DMN). However, whether between-network interactions facilitate the neuroplasticity after stroke rehabilitation remains a mystery. Therefore, we conducted the longitudinal assessment protocol of stroke rehabilitation, including three types of clinical evaluations and two types of functional magnetic resonance imaging (fMRI) techniques (resting state and grasp task). Twelve chronic stroke patients completed the rehabilitation protocol for at least 24 h and finished the three-time assessments: before, after rehabilitation, and 1 month after the cessation of rehabilitation. For comparison, age-matched normal controls (NC) underwent the same fMRI evaluation once without repeated measure. Increasing scores of the Fugl–Meyer assessment (FMA) and upper extremity performance test reflected the enhanced motor performances after the stroke rehabilitation process. Analysis of covariance (ANCOVA) results showed that the connections between posterior cingulate cortex (PCC) and iM1 were persistently enhanced in contrast to the pre-rehabilitation condition. The interactions between PCC and SMN were positively associated with motor performances. The enhanced cross-network connectivity facilitates the motor recovery after stroke rehabilitation, but the cross-network interaction was low before the rehabilitation process, similar to the level of NCs. Our findings suggested that cross-network connectivity plays a facilitatory role following the stroke rehabilitation, which can serve as a neurorehabilitative biomarker for future intervention evaluations.
- 16 June 2020
- Published by Frontiers Media SA in Frontiers in Neuroscience
- Vol. 14, 548
Open AccessSynchrony Between Default-Mode and Sensorimotor Networks Facilitates Motor Function in Stroke Rehabilitation: A Pilot fMRI Study
Stroke is the most common cause of complex disability in Taiwan. After stroke onset, persistent physical practice or exercise in the rehabilitation procedure reorganizes neural assembly for reducing motor deficits, known as neuroplasticity. Neuroimaging literature showed rehabilitative effects specific to the brain networks of the sensorimotor network (SMN) and default-mode network (DMN). However, whether between-network interactions facilitate the neuroplasticity after stroke rehabilitation remains a mystery. Therefore, we conducted the longitudinal assessment protocol of stroke rehabilitation, including three types of clinical evaluations and two types of functional magnetic resonance imaging (fMRI) techniques (resting state and grasp task). Twelve chronic stroke patients completed the rehabilitation protocol for at least 24 h and finished the three-time assessments: before, after rehabilitation, and 1 month after the cessation of rehabilitation. For comparison, age-matched normal controls (NC) underwent the same fMRI evaluation once without repeated measure. Increasing scores of the Fugl–Meyer assessment (FMA) and upper extremity performance test reflected the enhanced motor performances after the stroke rehabilitation process. Analysis of covariance (ANCOVA) results showed that the connections between posterior cingulate cortex (PCC) and iM1 were persistently enhanced in contrast to the pre-rehabilitation condition. The interactions between PCC and SMN were positively associated with motor performances. The enhanced cross-network connectivity facilitates the motor recovery after stroke rehabilitation, but the cross-network interaction was low before the rehabilitation process, similar to the level of NCs. Our findings suggested that cross-network connectivity plays a facilitatory role following the stroke rehabilitation, which can serve as a neurorehabilitative biomarker for future intervention evaluations.
- Open Access
- 10 April 2019
- Published by Wiley in Journal of Healthcare Engineering
- Vol. 2019, 1-6
Wearable Sensors Integrated with Virtual Reality: A Self-Guided Healthcare System Measuring Shoulder Joint Mobility for Frozen Shoulder
Frozen shoulder is a common clinical shoulder condition. Measuring the degree of shoulder joint movement is crucial to the rehabilitation process. Such measurements can be used to evaluate the severity of patients’ condition, establish rehabilitation goals and appropriate activity difficulty levels, and understand the effects of rehabilitation. Currently, measurements of the shoulder joint movement degree are typically conducted by therapists using a protractor. However, along with the growth of telerehabilitation, measuring the shoulder joint mobility on patients’ own at home will be needed. In this study, wireless inertial sensors were combined with the virtual reality interactive technology to provide an innovative shoulder joint mobility self-measurement system that can enable patients to measure their performance of four shoulder joint movements on their own at home. Pilot clinical trials were conducted with 25 patients to confirm the feasibility of the system. In addition, the results of correlation and differential analyses compared with the results of traditional measurement methods exhibited a high correlation, verifying the accuracy of the proposed system. Moreover, according to interviews with patients, they are confident in their ability to measure shoulder joint mobility themselves.
- 10 April 2019
- Published by Wiley in Journal of Healthcare Engineering
- Vol. 2019, 1-6
Open AccessWearable Sensors Integrated with Virtual Reality: A Self-Guided Healthcare System Measuring Shoulder Joint Mobility for Frozen Shoulder
Frozen shoulder is a common clinical shoulder condition. Measuring the degree of shoulder joint movement is crucial to the rehabilitation process. Such measurements can be used to evaluate the severity of patients’ condition, establish rehabilitation goals and appropriate activity difficulty levels, and understand the effects of rehabilitation. Currently, measurements of the shoulder joint movement degree are typically conducted by therapists using a protractor. However, along with the growth of telerehabilitation, measuring the shoulder joint mobility on patients’ own at home will be needed. In this study, wireless inertial sensors were combined with the virtual reality interactive technology to provide an innovative shoulder joint mobility self-measurement system that can enable patients to measure their performance of four shoulder joint movements on their own at home. Pilot clinical trials were conducted with 25 patients to confirm the feasibility of the system. In addition, the results of correlation and differential analyses compared with the results of traditional measurement methods exhibited a high correlation, verifying the accuracy of the proposed system. Moreover, according to interviews with patients, they are confident in their ability to measure shoulder joint mobility themselves.