Benjamin Butler
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Benjamin Butler has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
- Han Seng Chew
From the Department of Neuroradiology, Queen Elizabeth Hospital Birmingham, Birmingham, UK
3 shared publications - Dilina Rajapakse
Interventional Neuroradiology, Queen Elizabeth Hospital, University Hospitals Birmingham NHS Trust, United Kingdom (W.B., S.L., S.C., H.S.C., K.N., S.A.-A., B.B., D.R.).
2 shared publications - Saleh Lamin
Neuroreadiology, University Hospitals Birmingham NHS Foundation Trust, Birmingham, UK
2 shared publications - Samer Al-Ali
From the Department of Neuroradiology, Queen Elizabeth Hospital Birmingham, Birmingham, UK
2 shared publications - Swarupsinh Chavda
From the Department of Neuroradiology, Queen Elizabeth Hospital Birmingham, Birmingham, UK
2 shared publications - Alex Mortimer
Southmead Hospital, Bristol NHS Foundation Trust, Bristol BS10 5NB, UK
1 shared publication
Latest Publications
- Open Access
- 30 January 2024
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 45 (6) , 731-736
Lateral Compression Manipulation: A Simple Approach for Sizing Taller-Than-Wide Intracranial Aneurysms with the Woven EndoBridge Device
BACKGROUND AND PURPOSE: The Woven EndoBridge (WEB) system (MicroVention in Tustin, CA, USA) has established itself as a safe and effective option for managing wide-necked bifurcation aneurysms. Addressing aneurysms with a greater height than width using conventional WEB sizing methods has proven ineffective due to the inherent configuration of the devices. To overcome this limitation, we propose an intuitive approach which involves swapping the width and height dimensions of the aneurysm to determine the appropriate WEB size. MATERIALS AND METHODS: A retrospective analysis was conducted on patients undergoing WEB embolization treatment at a single neuroscience center from March 2013 to February 2023. RESULTS: Twenty-five eligible aneurysms were identified, with the height dimension exceeding the width by an average of 2.33 mm (ranging from 1.4 to 4.5 mm). Out of these, twenty cases adhered to the recommended sizing technique, resulting in a 100% success rate of adequate occlusion (14/20 complete occlusion, 6/20 proximal recess filling). In contrast, the outcomes for the remaining five cases that did not follow the proposed sizing method were less favorable (p<0.05). Among these, four cases treated with undersized WEBs showed neck remnants during follow-up, and one patient who received an oversized WEB required device replacement during the same procedure. CONCLUSIONS: The simple sizing method we proposed for treating taller-than-wide aneurysms has demonstrated promising results, allowing the WEB system to address twice the original size range of treatable aneurysms. Further research with a larger sample size is recommended. ABBREVIATIONS: WEB = Woven EndoBridge; SL = Single Layer; SLS = Single Layer Sphere.
- 30 January 2024
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 45 (6) , 731-736
Open AccessLateral Compression Manipulation: A Simple Approach for Sizing Taller-Than-Wide Intracranial Aneurysms with the Woven EndoBridge Device
BACKGROUND AND PURPOSE: The Woven EndoBridge (WEB) system (MicroVention in Tustin, CA, USA) has established itself as a safe and effective option for managing wide-necked bifurcation aneurysms. Addressing aneurysms with a greater height than width using conventional WEB sizing methods has proven ineffective due to the inherent configuration of the devices. To overcome this limitation, we propose an intuitive approach which involves swapping the width and height dimensions of the aneurysm to determine the appropriate WEB size. MATERIALS AND METHODS: A retrospective analysis was conducted on patients undergoing WEB embolization treatment at a single neuroscience center from March 2013 to February 2023. RESULTS: Twenty-five eligible aneurysms were identified, with the height dimension exceeding the width by an average of 2.33 mm (ranging from 1.4 to 4.5 mm). Out of these, twenty cases adhered to the recommended sizing technique, resulting in a 100% success rate of adequate occlusion (14/20 complete occlusion, 6/20 proximal recess filling). In contrast, the outcomes for the remaining five cases that did not follow the proposed sizing method were less favorable (p<0.05). Among these, four cases treated with undersized WEBs showed neck remnants during follow-up, and one patient who received an oversized WEB required device replacement during the same procedure. CONCLUSIONS: The simple sizing method we proposed for treating taller-than-wide aneurysms has demonstrated promising results, allowing the WEB system to address twice the original size range of treatable aneurysms. Further research with a larger sample size is recommended. ABBREVIATIONS: WEB = Woven EndoBridge; SL = Single Layer; SLS = Single Layer Sphere.
- Open Access
- 4 May 2022
- Published by Wolters Kluwer Health in Stroke
- Vol. 53 (9) , 2770-2778
Perfusion Imaging for Endovascular Thrombectomy in Acute Ischemic Stroke Is Associated With Improved Functional Outcomes in the Early and Late Time Windows
Background: The impact on clinical outcomes of patient selection using perfusion imaging for endovascular thrombectomy (EVT) in patients with acute ischemic stroke presenting beyond 6 hours from onset remains undetermined in routine clinical practice. Methods: Patients from a national stroke registry that underwent EVT selected with or without perfusion imaging (noncontrast computed tomography/computed tomography angiography) in the early (P =0.001). There was no significant difference in functional independence (29.3% with perfusion versus 24.8% without; P =0.210) or in the safety outcome measures of symptomatic intracerebral hemorrhage ( P =0.53) and in-hospital mortality (10.6% with perfusion versus 14.3% without; P =0.053). In the early time window, patients with perfusion imaging had significantly improved odds of functional outcome (adjusted common OR, 1.51 [95% CI, 1.28–1.78]; P =0.0001) and functional independence (41.6% versus 33.6%, adjusted OR, 1.31 [95% CI, 1.08–1.59]; P =0.006). Perfusion imaging was associated with lower odds of futile recanalization in both time windows (late: adjusted OR, 0.70 [95% CI, 0.50–0.97]; P =0.034; early: adjusted OR, 0.80 [95% CI, 0.65–0.99]; P =0.047). Conclusions: In this real-world study, acquisition of perfusion imaging for EVT was associated with improvement in functional disability in the early and late time windows compared with nonperfusion neuroimaging. These indirect comparisons should be interpreted with caution while awaiting confirmatory data from prospective randomized trials.
- 4 May 2022
- Published by Wolters Kluwer Health in Stroke
- Vol. 53 (9) , 2770-2778
Open AccessPerfusion Imaging for Endovascular Thrombectomy in Acute Ischemic Stroke Is Associated With Improved Functional Outcomes in the Early and Late Time Windows
Background: The impact on clinical outcomes of patient selection using perfusion imaging for endovascular thrombectomy (EVT) in patients with acute ischemic stroke presenting beyond 6 hours from onset remains undetermined in routine clinical practice. Methods: Patients from a national stroke registry that underwent EVT selected with or without perfusion imaging (noncontrast computed tomography/computed tomography angiography) in the early (P =0.001). There was no significant difference in functional independence (29.3% with perfusion versus 24.8% without; P =0.210) or in the safety outcome measures of symptomatic intracerebral hemorrhage ( P =0.53) and in-hospital mortality (10.6% with perfusion versus 14.3% without; P =0.053). In the early time window, patients with perfusion imaging had significantly improved odds of functional outcome (adjusted common OR, 1.51 [95% CI, 1.28–1.78]; P =0.0001) and functional independence (41.6% versus 33.6%, adjusted OR, 1.31 [95% CI, 1.08–1.59]; P =0.006). Perfusion imaging was associated with lower odds of futile recanalization in both time windows (late: adjusted OR, 0.70 [95% CI, 0.50–0.97]; P =0.034; early: adjusted OR, 0.80 [95% CI, 0.65–0.99]; P =0.047). Conclusions: In this real-world study, acquisition of perfusion imaging for EVT was associated with improvement in functional disability in the early and late time windows compared with nonperfusion neuroimaging. These indirect comparisons should be interpreted with caution while awaiting confirmatory data from prospective randomized trials.
- 20 January 2022
- Published by Wiley in Internal Medicine Journal
- Vol. 52 (1) , 150-151
Chronic cough and drug‐induced eosinophilic bronchitis
- 20 January 2022
- Published by Wiley in Internal Medicine Journal
- Vol. 52 (1) , 150-151
Chronic cough and drug‐induced eosinophilic bronchitis
- 23 December 2021
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 43 (1) , 98-101
Mechanical Thrombectomy for Treatment of Cerebral Venous Sinus Thrombosis in Vaccine-Induced Immune Thrombotic Thrombocytopenia
SUMMARY: Reports of a rare form of cerebral venous sinus thrombosis with profound thrombocytopenia have emerged following introduction of the adenovirus-vectored coronavirus disease 2019 (COVID-19) vaccines. Between March and June 2021, seven cases of refractory vaccine-induced immune thrombotic thrombocytopenia were referred to our institution for mechanical thrombectomy. The condition of 1 patient deteriorated during interhospital transfer, and the remaining 6 underwent successful recanalization. No procedure-related adverse events were reported. At the time of this writing, 3 patients have been discharged with a good functional outcome (mRS 0–1), one required rehabilitation for mild dysarthria and vocal cord palsy (mRS 3), and 2 have died due to severe mass effect. Our anecdotal experience suggests that endovascular therapy may be safe and effective in reducing thrombus burden in selected cases of postvaccination cerebral venous sinus thrombosis.
- 23 December 2021
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 43 (1) , 98-101
Mechanical Thrombectomy for Treatment of Cerebral Venous Sinus Thrombosis in Vaccine-Induced Immune Thrombotic Thrombocytopenia
SUMMARY: Reports of a rare form of cerebral venous sinus thrombosis with profound thrombocytopenia have emerged following introduction of the adenovirus-vectored coronavirus disease 2019 (COVID-19) vaccines. Between March and June 2021, seven cases of refractory vaccine-induced immune thrombotic thrombocytopenia were referred to our institution for mechanical thrombectomy. The condition of 1 patient deteriorated during interhospital transfer, and the remaining 6 underwent successful recanalization. No procedure-related adverse events were reported. At the time of this writing, 3 patients have been discharged with a good functional outcome (mRS 0–1), one required rehabilitation for mild dysarthria and vocal cord palsy (mRS 3), and 2 have died due to severe mass effect. Our anecdotal experience suggests that endovascular therapy may be safe and effective in reducing thrombus burden in selected cases of postvaccination cerebral venous sinus thrombosis.
- Open Access
- 10 November 2016
- Published by Wiley in Case Reports in Infectious Diseases
- Vol. 2016, 1-3
Symptomatic Acute Hepatitis C Infection Following a Single Episode of Unprotected Sexual Intercourse
A previously healthy 23-year-old MSM presented with jaundice, systemic upset, and rash 2 months after a single episode of unprotected sexual intercourse. Liver biochemistry was grossly deranged, with markedly elevated transaminases and hyperbilirubinaemia. Serology was positive for genotype 1a hepatitis C virus (HCV) and in the absence of other causes, acute HCV infection was suspected. He was subsequently successfully treated with pegylated interferon and ribavirin for 24 weeks and made a full clinical and biochemical recovery.
- 10 November 2016
- Published by Wiley in Case Reports in Infectious Diseases
- Vol. 2016, 1-3
Open AccessSymptomatic Acute Hepatitis C Infection Following a Single Episode of Unprotected Sexual Intercourse
A previously healthy 23-year-old MSM presented with jaundice, systemic upset, and rash 2 months after a single episode of unprotected sexual intercourse. Liver biochemistry was grossly deranged, with markedly elevated transaminases and hyperbilirubinaemia. Serology was positive for genotype 1a hepatitis C virus (HCV) and in the absence of other causes, acute HCV infection was suspected. He was subsequently successfully treated with pegylated interferon and ribavirin for 24 weeks and made a full clinical and biochemical recovery.