Han Seng Chew
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Han Seng Chew has a total of 63 co-authors. Here are the top co-authors by number of shared publications:
- Saleh Lamin
Neuroreadiology, University Hospitals Birmingham NHS Foundation Trust, Birmingham, UK
4 shared publications - Benjamin Butler
From the Department of Neuroradiology, Queen Elizabeth Hospital Birmingham, Birmingham, UK
3 shared publications - Swarupsinh Chavda
From the Department of Neuroradiology, Queen Elizabeth Hospital Birmingham, Birmingham, UK
3 shared publications - Dilina Rajapakse
Interventional Neuroradiology, Queen Elizabeth Hospital, University Hospitals Birmingham NHS Trust, United Kingdom (W.B., S.L., S.C., H.S.C., K.N., S.A.-A., B.B., D.R.).
2 shared publications Saleh Lamin
Interventional Neuroradiology. Radiology, Queen Elizabeth Hospital, Birmingham, UK
2 shared publications- Samer Al-Ali
From the Department of Neuroradiology, Queen Elizabeth Hospital Birmingham, Birmingham, UK
2 shared publications
Latest Publications
- 2 May 2025
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 18 (4) , 1093-1099
Height-preserving sizing method for the new Artisse intrasaccular device based on early findings from 26 cases of intracranial aneurysm embolization
Background and purpose With the recent relaunch of Artisse 2.0, optimal sizing strategies for the device are still being refined. The official sizing chart covers only taller-than-wide aneurysms within a limited diameter range of 3.4–6 mm. To expand its applicability, we propose an intuitive sizing strategy emphasizing the importance of preserving the device’s natural height. Materials and methods Patients treated with the Artisse 2.0 between November 2022 and October 2024 were retrospectively analyzed. Results Among 26 aneurysms treated over a 24-month period, 13 exhibited varying degrees of ‘dog-ear’ formation on post-deployment imaging. These cases showed greater width oversizing (+2.06 vs +1.29 mm, PConclusion In contrast to the Woven EndoBridge (WEB) device, excessive lateral compression and height reduction appear to undermine the stability of the Artisse 2.0. As a result, the device size for spherical or ovoid aneurysms can be determined using the ‘+1/–1’ method, while the ‘+1/–0’ approach is recommended for cylindrical aneurysms to improve neck coverage through height preservation. These proposed sizing strategies may serve as a practical interim solution until more clinical data and user experience become available.
- 2 May 2025
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 18 (4) , 1093-1099
Height-preserving sizing method for the new Artisse intrasaccular device based on early findings from 26 cases of intracranial aneurysm embolization
Background and purpose With the recent relaunch of Artisse 2.0, optimal sizing strategies for the device are still being refined. The official sizing chart covers only taller-than-wide aneurysms within a limited diameter range of 3.4–6 mm. To expand its applicability, we propose an intuitive sizing strategy emphasizing the importance of preserving the device’s natural height. Materials and methods Patients treated with the Artisse 2.0 between November 2022 and October 2024 were retrospectively analyzed. Results Among 26 aneurysms treated over a 24-month period, 13 exhibited varying degrees of ‘dog-ear’ formation on post-deployment imaging. These cases showed greater width oversizing (+2.06 vs +1.29 mm, PConclusion In contrast to the Woven EndoBridge (WEB) device, excessive lateral compression and height reduction appear to undermine the stability of the Artisse 2.0. As a result, the device size for spherical or ovoid aneurysms can be determined using the ‘+1/–1’ method, while the ‘+1/–0’ approach is recommended for cylindrical aneurysms to improve neck coverage through height preservation. These proposed sizing strategies may serve as a practical interim solution until more clinical data and user experience become available.
- Open Access
- 13 January 2025
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 18 (2) , 558-567
New Artisse intrasaccular device for intracranial aneurysm treatment: short term clinical and angiographic result from the prospective registry INSPIRE-A
Background: Intrasaccular devices have broadened treatment options for wide necked aneurysms. This study presents the preliminary experience with the Artisse 2.0 device. Methods: Innovative NeurovaScular Product SurveIllance REgistry (INSPIRE) is a non-randomized, multicenter, real world clinical study with treatment arms for aneurysms (INSPIRE-A) and acute ischemic stroke (INSPIRE-S). This interim analysis included 87 patients enrolled from November 2022 to April 2024 in the INSPIRE-A Artisse cohort across 16 Europoean centers. Procedures followed standard clinical care, with 6 months of follow-up. Safety and efficacy endpoints included major stroke, neurological death, serious adverse events (SAEs), aneurysm occlusion, and retreatment rates. An independent core laboratory assessed imaging, and all SAEs were reviewed by a clinical events committee. The Artisse steering committee provided independent oversight of the data. Results: The Artisse device achieved an overall successful implantation rate of 96.6% (84/87), with satisfactory placement rates of 98.7% (74/75) for unruptured and 88.9% (8/9) for ruptured aneurysms. Following the procedure, 46.2% of unruptured aneurysm patients were receiving antiplatelet therapy (APT), predominantly aspirin monotherapy, while no ruptured aneurysm patients received APT. Device related SAE rate was 1.3% (1/87), and the overall stroke rate was 2.3% (2/87), including both ruptured and unruptured aneurysms. At 6 months, 80.0% (28/35) of patients with unruptured aneurysms showed complete obliteration, with no recurrences or retreatments. Conclusions: Preliminary experience with the Artisse 2.0 device demonstrated high technical success, favorable safety, and efficacy in aneurysm obliteration at 6 months. Larger studies with longer follow-up periods are needed to confirm these findings.
- 13 January 2025
- Published by BMJ in Journal of NeuroInterventional Surgery
- Vol. 18 (2) , 558-567
Open AccessNew Artisse intrasaccular device for intracranial aneurysm treatment: short term clinical and angiographic result from the prospective registry INSPIRE-A
Background: Intrasaccular devices have broadened treatment options for wide necked aneurysms. This study presents the preliminary experience with the Artisse 2.0 device. Methods: Innovative NeurovaScular Product SurveIllance REgistry (INSPIRE) is a non-randomized, multicenter, real world clinical study with treatment arms for aneurysms (INSPIRE-A) and acute ischemic stroke (INSPIRE-S). This interim analysis included 87 patients enrolled from November 2022 to April 2024 in the INSPIRE-A Artisse cohort across 16 Europoean centers. Procedures followed standard clinical care, with 6 months of follow-up. Safety and efficacy endpoints included major stroke, neurological death, serious adverse events (SAEs), aneurysm occlusion, and retreatment rates. An independent core laboratory assessed imaging, and all SAEs were reviewed by a clinical events committee. The Artisse steering committee provided independent oversight of the data. Results: The Artisse device achieved an overall successful implantation rate of 96.6% (84/87), with satisfactory placement rates of 98.7% (74/75) for unruptured and 88.9% (8/9) for ruptured aneurysms. Following the procedure, 46.2% of unruptured aneurysm patients were receiving antiplatelet therapy (APT), predominantly aspirin monotherapy, while no ruptured aneurysm patients received APT. Device related SAE rate was 1.3% (1/87), and the overall stroke rate was 2.3% (2/87), including both ruptured and unruptured aneurysms. At 6 months, 80.0% (28/35) of patients with unruptured aneurysms showed complete obliteration, with no recurrences or retreatments. Conclusions: Preliminary experience with the Artisse 2.0 device demonstrated high technical success, favorable safety, and efficacy in aneurysm obliteration at 6 months. Larger studies with longer follow-up periods are needed to confirm these findings.
- Open Access
- 30 January 2024
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 45 (6) , 731-736
Lateral Compression Manipulation: A Simple Approach for Sizing Taller-Than-Wide Intracranial Aneurysms with the Woven EndoBridge Device
BACKGROUND AND PURPOSE: The Woven EndoBridge (WEB) system (MicroVention in Tustin, CA, USA) has established itself as a safe and effective option for managing wide-necked bifurcation aneurysms. Addressing aneurysms with a greater height than width using conventional WEB sizing methods has proven ineffective due to the inherent configuration of the devices. To overcome this limitation, we propose an intuitive approach which involves swapping the width and height dimensions of the aneurysm to determine the appropriate WEB size. MATERIALS AND METHODS: A retrospective analysis was conducted on patients undergoing WEB embolization treatment at a single neuroscience center from March 2013 to February 2023. RESULTS: Twenty-five eligible aneurysms were identified, with the height dimension exceeding the width by an average of 2.33 mm (ranging from 1.4 to 4.5 mm). Out of these, twenty cases adhered to the recommended sizing technique, resulting in a 100% success rate of adequate occlusion (14/20 complete occlusion, 6/20 proximal recess filling). In contrast, the outcomes for the remaining five cases that did not follow the proposed sizing method were less favorable (p<0.05). Among these, four cases treated with undersized WEBs showed neck remnants during follow-up, and one patient who received an oversized WEB required device replacement during the same procedure. CONCLUSIONS: The simple sizing method we proposed for treating taller-than-wide aneurysms has demonstrated promising results, allowing the WEB system to address twice the original size range of treatable aneurysms. Further research with a larger sample size is recommended. ABBREVIATIONS: WEB = Woven EndoBridge; SL = Single Layer; SLS = Single Layer Sphere.
- 30 January 2024
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 45 (6) , 731-736
Open AccessLateral Compression Manipulation: A Simple Approach for Sizing Taller-Than-Wide Intracranial Aneurysms with the Woven EndoBridge Device
BACKGROUND AND PURPOSE: The Woven EndoBridge (WEB) system (MicroVention in Tustin, CA, USA) has established itself as a safe and effective option for managing wide-necked bifurcation aneurysms. Addressing aneurysms with a greater height than width using conventional WEB sizing methods has proven ineffective due to the inherent configuration of the devices. To overcome this limitation, we propose an intuitive approach which involves swapping the width and height dimensions of the aneurysm to determine the appropriate WEB size. MATERIALS AND METHODS: A retrospective analysis was conducted on patients undergoing WEB embolization treatment at a single neuroscience center from March 2013 to February 2023. RESULTS: Twenty-five eligible aneurysms were identified, with the height dimension exceeding the width by an average of 2.33 mm (ranging from 1.4 to 4.5 mm). Out of these, twenty cases adhered to the recommended sizing technique, resulting in a 100% success rate of adequate occlusion (14/20 complete occlusion, 6/20 proximal recess filling). In contrast, the outcomes for the remaining five cases that did not follow the proposed sizing method were less favorable (p<0.05). Among these, four cases treated with undersized WEBs showed neck remnants during follow-up, and one patient who received an oversized WEB required device replacement during the same procedure. CONCLUSIONS: The simple sizing method we proposed for treating taller-than-wide aneurysms has demonstrated promising results, allowing the WEB system to address twice the original size range of treatable aneurysms. Further research with a larger sample size is recommended. ABBREVIATIONS: WEB = Woven EndoBridge; SL = Single Layer; SLS = Single Layer Sphere.
- Open Access
- 4 May 2022
- Published by Wolters Kluwer Health in Stroke
- Vol. 53 (9) , 2770-2778
Perfusion Imaging for Endovascular Thrombectomy in Acute Ischemic Stroke Is Associated With Improved Functional Outcomes in the Early and Late Time Windows
Background: The impact on clinical outcomes of patient selection using perfusion imaging for endovascular thrombectomy (EVT) in patients with acute ischemic stroke presenting beyond 6 hours from onset remains undetermined in routine clinical practice. Methods: Patients from a national stroke registry that underwent EVT selected with or without perfusion imaging (noncontrast computed tomography/computed tomography angiography) in the early (P =0.001). There was no significant difference in functional independence (29.3% with perfusion versus 24.8% without; P =0.210) or in the safety outcome measures of symptomatic intracerebral hemorrhage ( P =0.53) and in-hospital mortality (10.6% with perfusion versus 14.3% without; P =0.053). In the early time window, patients with perfusion imaging had significantly improved odds of functional outcome (adjusted common OR, 1.51 [95% CI, 1.28–1.78]; P =0.0001) and functional independence (41.6% versus 33.6%, adjusted OR, 1.31 [95% CI, 1.08–1.59]; P =0.006). Perfusion imaging was associated with lower odds of futile recanalization in both time windows (late: adjusted OR, 0.70 [95% CI, 0.50–0.97]; P =0.034; early: adjusted OR, 0.80 [95% CI, 0.65–0.99]; P =0.047). Conclusions: In this real-world study, acquisition of perfusion imaging for EVT was associated with improvement in functional disability in the early and late time windows compared with nonperfusion neuroimaging. These indirect comparisons should be interpreted with caution while awaiting confirmatory data from prospective randomized trials.
- 4 May 2022
- Published by Wolters Kluwer Health in Stroke
- Vol. 53 (9) , 2770-2778
Open AccessPerfusion Imaging for Endovascular Thrombectomy in Acute Ischemic Stroke Is Associated With Improved Functional Outcomes in the Early and Late Time Windows
Background: The impact on clinical outcomes of patient selection using perfusion imaging for endovascular thrombectomy (EVT) in patients with acute ischemic stroke presenting beyond 6 hours from onset remains undetermined in routine clinical practice. Methods: Patients from a national stroke registry that underwent EVT selected with or without perfusion imaging (noncontrast computed tomography/computed tomography angiography) in the early (P =0.001). There was no significant difference in functional independence (29.3% with perfusion versus 24.8% without; P =0.210) or in the safety outcome measures of symptomatic intracerebral hemorrhage ( P =0.53) and in-hospital mortality (10.6% with perfusion versus 14.3% without; P =0.053). In the early time window, patients with perfusion imaging had significantly improved odds of functional outcome (adjusted common OR, 1.51 [95% CI, 1.28–1.78]; P =0.0001) and functional independence (41.6% versus 33.6%, adjusted OR, 1.31 [95% CI, 1.08–1.59]; P =0.006). Perfusion imaging was associated with lower odds of futile recanalization in both time windows (late: adjusted OR, 0.70 [95% CI, 0.50–0.97]; P =0.034; early: adjusted OR, 0.80 [95% CI, 0.65–0.99]; P =0.047). Conclusions: In this real-world study, acquisition of perfusion imaging for EVT was associated with improvement in functional disability in the early and late time windows compared with nonperfusion neuroimaging. These indirect comparisons should be interpreted with caution while awaiting confirmatory data from prospective randomized trials.
- 23 December 2021
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 43 (1) , 98-101
Mechanical Thrombectomy for Treatment of Cerebral Venous Sinus Thrombosis in Vaccine-Induced Immune Thrombotic Thrombocytopenia
SUMMARY: Reports of a rare form of cerebral venous sinus thrombosis with profound thrombocytopenia have emerged following introduction of the adenovirus-vectored coronavirus disease 2019 (COVID-19) vaccines. Between March and June 2021, seven cases of refractory vaccine-induced immune thrombotic thrombocytopenia were referred to our institution for mechanical thrombectomy. The condition of 1 patient deteriorated during interhospital transfer, and the remaining 6 underwent successful recanalization. No procedure-related adverse events were reported. At the time of this writing, 3 patients have been discharged with a good functional outcome (mRS 0–1), one required rehabilitation for mild dysarthria and vocal cord palsy (mRS 3), and 2 have died due to severe mass effect. Our anecdotal experience suggests that endovascular therapy may be safe and effective in reducing thrombus burden in selected cases of postvaccination cerebral venous sinus thrombosis.
- 23 December 2021
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 43 (1) , 98-101
Mechanical Thrombectomy for Treatment of Cerebral Venous Sinus Thrombosis in Vaccine-Induced Immune Thrombotic Thrombocytopenia
SUMMARY: Reports of a rare form of cerebral venous sinus thrombosis with profound thrombocytopenia have emerged following introduction of the adenovirus-vectored coronavirus disease 2019 (COVID-19) vaccines. Between March and June 2021, seven cases of refractory vaccine-induced immune thrombotic thrombocytopenia were referred to our institution for mechanical thrombectomy. The condition of 1 patient deteriorated during interhospital transfer, and the remaining 6 underwent successful recanalization. No procedure-related adverse events were reported. At the time of this writing, 3 patients have been discharged with a good functional outcome (mRS 0–1), one required rehabilitation for mild dysarthria and vocal cord palsy (mRS 3), and 2 have died due to severe mass effect. Our anecdotal experience suggests that endovascular therapy may be safe and effective in reducing thrombus burden in selected cases of postvaccination cerebral venous sinus thrombosis.
- Open Access
- 8 December 2016
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 38 (1) , 127-131
Embolization of Intracranial Dural Arteriovenous Fistulas Using PHIL Liquid Embolic Agent in 26 Patients: A Multicenter Study
BACKGROUND AND PURPOSE: The introduction of liquid embolic agents has revolutionized endovascular approach to cranial vascular malformations. The aim of the study was to retrospectively assess the efficacy and safety of Precipitating Hydrophobic Injectable Liquid (PHIL), a new nonadhesive liquid embolic agent, in the treatment of patients with cranial dural arteriovenous fistulas. The primary end point was the rate of complete occlusion of dural arteriovenous fistulas. Secondary end points included the incidence of adverse events and clinical status at 3-month follow-up. MATERIALS AND METHODS: This was a retrospective multicenter study. Twenty-six consecutive patients with dural arteriovenous fistulas (de novo or previously treated) treated by injection of PHIL only or with PHIL in combination with other embolization products (such as Onyx or detachable coils) were included in the study. Recruitment started in August 2014 and ended in September 2015. RESULTS: Twenty-two (85%) patients were treated with PHIL only, with 3 patients treated with both PHIL and Onyx, and 1, with both PHIL and coils. Immediate complete angiographic occlusion was achieved in 20 (77%) patients. Of the 6 patients with residual fistulas, 3 were retreated with PHIL and 1 achieved angiographic cure. An adverse event was seen in 1 patient who developed worsening of preexisting ataxia due to acute thrombosis of the draining vein. CONCLUSIONS: PHIL appears to be safe and effective for endovascular treatment of cranial dural arteriovenous fistulas. Short-term angiographic and clinical results are comparable with those of Onyx, with the added advantage of easier preparation and improved homogeneous cast visualization. The use of iodine as a radio-opacifier also produces considerably less artifacts on CT compared with tantalum-based embolic materials.
- 8 December 2016
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 38 (1) , 127-131
Open AccessEmbolization of Intracranial Dural Arteriovenous Fistulas Using PHIL Liquid Embolic Agent in 26 Patients: A Multicenter Study
BACKGROUND AND PURPOSE: The introduction of liquid embolic agents has revolutionized endovascular approach to cranial vascular malformations. The aim of the study was to retrospectively assess the efficacy and safety of Precipitating Hydrophobic Injectable Liquid (PHIL), a new nonadhesive liquid embolic agent, in the treatment of patients with cranial dural arteriovenous fistulas. The primary end point was the rate of complete occlusion of dural arteriovenous fistulas. Secondary end points included the incidence of adverse events and clinical status at 3-month follow-up. MATERIALS AND METHODS: This was a retrospective multicenter study. Twenty-six consecutive patients with dural arteriovenous fistulas (de novo or previously treated) treated by injection of PHIL only or with PHIL in combination with other embolization products (such as Onyx or detachable coils) were included in the study. Recruitment started in August 2014 and ended in September 2015. RESULTS: Twenty-two (85%) patients were treated with PHIL only, with 3 patients treated with both PHIL and Onyx, and 1, with both PHIL and coils. Immediate complete angiographic occlusion was achieved in 20 (77%) patients. Of the 6 patients with residual fistulas, 3 were retreated with PHIL and 1 achieved angiographic cure. An adverse event was seen in 1 patient who developed worsening of preexisting ataxia due to acute thrombosis of the draining vein. CONCLUSIONS: PHIL appears to be safe and effective for endovascular treatment of cranial dural arteriovenous fistulas. Short-term angiographic and clinical results are comparable with those of Onyx, with the added advantage of easier preparation and improved homogeneous cast visualization. The use of iodine as a radio-opacifier also produces considerably less artifacts on CT compared with tantalum-based embolic materials.