Hamza Feza Carlak
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Hamza Feza Carlak has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
- Ergin Kayar
Akdeniz Universitesi
5 shared publications - Şükrü Özen
Akdeniz Universitesi
5 shared publications - Ayhan Şavklıyıldız
Department of Electrical and Electronics Engineering, Faculty of Engineering Akdeniz University Antalya Turkey
2 shared publications - Buket Simsek
Akdeniz Universitesi
2 shared publications Cengiz Besikci
2 shared publicationsErgin Kayar
Department of Electrical and Electronics Engineering , Akdeniz University , Turkey
2 shared publications
Latest Publications
- 27 October 2026
- Published by Türkiye Elektrik Sanayi Birliği Derneği in Turkish Journal of Electrical Power and Energy Systems
- Vol. 6 (3) , 155-166
Optimal Power Flow Control and Emergency Voltage Control with A Unified Power Flow Controller (UPFC) to Improve The Performance of The Power System
The increasing global energy demand has intensified pressure on existing transmission infrastructure, giving rise to thermal overloads, voltage instability, and elevated power losses. Flexible Alternating Current Transmission System (FACTS) devices have emerged as a technically viable solution to enhance the controllability and power transfer capability of existing networks without significant infrastructural expansion. Among FACTS controllers, the Unified Power Flow Controller (UPFC) is distinguished as the most versatile device, capable of regulating active power flow, reactive power flow, and bus voltage magnitude simultaneously. This paper presents a comprehensive simulation study of UPFC performance using the IEEE 9-bus benchmark transmission network, which was modeled in DIgSILENT PowerFactory. The voltage stability indices and line stability factors identify Bus 8 as the optimal point for UPFC installation. Four simulation scenarios are investigated: the base case without UPFC, UPFC integrated at Bus 8 under normal full-load conditions, N-1 line contingency with three compensation strategies compared, and a generator outage response. The findings indicate that the integration of UPFC results in a 19.64% decrease in active power losses and a 32.74% decrease in reactive power losses. In the context of the N-1 line contingency, the uncompensated system permits a voltage collapse of Bus 8 to 0.909 pu. However, UPFC effectively restores the voltage to above 1.020 pu within approximately 20 seconds, thereby demonstrating a substantial performance enhancement in comparison to the fixed capacitor bank compensation. During generator outages, the UPFC has been shown to limit the Bus 7 voltage dip to 0.986 pu with rapid stabilization in comparison to a sustained depression to 0.967 pu without compensation. The findings confirm the technical superiority of UPFC as a multi-functional FACTS controller for modernizing voltage-constrained transmission networks.
- 27 October 2026
- Published by Türkiye Elektrik Sanayi Birliği Derneği in Turkish Journal of Electrical Power and Energy Systems
- Vol. 6 (3) , 155-166
Optimal Power Flow Control and Emergency Voltage Control with A Unified Power Flow Controller (UPFC) to Improve The Performance of The Power System
The increasing global energy demand has intensified pressure on existing transmission infrastructure, giving rise to thermal overloads, voltage instability, and elevated power losses. Flexible Alternating Current Transmission System (FACTS) devices have emerged as a technically viable solution to enhance the controllability and power transfer capability of existing networks without significant infrastructural expansion. Among FACTS controllers, the Unified Power Flow Controller (UPFC) is distinguished as the most versatile device, capable of regulating active power flow, reactive power flow, and bus voltage magnitude simultaneously. This paper presents a comprehensive simulation study of UPFC performance using the IEEE 9-bus benchmark transmission network, which was modeled in DIgSILENT PowerFactory. The voltage stability indices and line stability factors identify Bus 8 as the optimal point for UPFC installation. Four simulation scenarios are investigated: the base case without UPFC, UPFC integrated at Bus 8 under normal full-load conditions, N-1 line contingency with three compensation strategies compared, and a generator outage response. The findings indicate that the integration of UPFC results in a 19.64% decrease in active power losses and a 32.74% decrease in reactive power losses. In the context of the N-1 line contingency, the uncompensated system permits a voltage collapse of Bus 8 to 0.909 pu. However, UPFC effectively restores the voltage to above 1.020 pu within approximately 20 seconds, thereby demonstrating a substantial performance enhancement in comparison to the fixed capacitor bank compensation. During generator outages, the UPFC has been shown to limit the Bus 7 voltage dip to 0.986 pu with rapid stabilization in comparison to a sustained depression to 0.967 pu without compensation. The findings confirm the technical superiority of UPFC as a multi-functional FACTS controller for modernizing voltage-constrained transmission networks.
- Open Access
- 14 January 2026
- Published by Walter de Gruyter GmbH in B&H Electrical Engineering
- Vol. 20 (1) , 29-37
Power System Recovery Strategy After a Major Blackout
A plethora of factors have been identified as contributing to the current deficit in energy production and supply. These include power outages, transmission line overloads, discrepancies between energy production and demand, errors in load forecasting, meteorological phenomena, maintenance issues, cyber-attacks, and terrorist or criminal acts. The unpredictability in the production of renewable energy sources, aggravating the problem of consistently matching supply to demand in electricity grids. This article considers the possibility of a power outage over a large area of the interconnected electricity transmission system. It also presents how to prevent such a possibility, as well as the remedial actions to follow to prevent a catastrophic event such as a power outage. The safety criteria of the transmission system, the defense plans and the remedial actions that the system operator should prepare to prevent a major power outage are described. First, the major power outages that have occurred in recent years are presented and their causes are examined. In addition, it has been tried to find similarities between the past power cuts in Turkey and the state of the European electricity grid. A transmission failure simulation test environment has been developed to understand the characteristics of realistic transmission level disturbances propagated to the power system and the effects of such disturbances on the performance of conventional conservation and restoration technologies. By using both Black Start units and connection lines from neighboring system operators, it was ensured that restoration time was minimized by creating separate islands that would eventually be synchronized. In the study, a restoration strategy was presented. The proposed strategy has been tested and validated in the IEEE-39 bus system. The results proved the efficiency of the restoration strategy, as the total restoration time was sufficiently short depending on the complexity of each system, and critical loads were primarily fed.
- 14 January 2026
- Published by Walter de Gruyter GmbH in B&H Electrical Engineering
- Vol. 20 (1) , 29-37
Open AccessPower System Recovery Strategy After a Major Blackout
A plethora of factors have been identified as contributing to the current deficit in energy production and supply. These include power outages, transmission line overloads, discrepancies between energy production and demand, errors in load forecasting, meteorological phenomena, maintenance issues, cyber-attacks, and terrorist or criminal acts. The unpredictability in the production of renewable energy sources, aggravating the problem of consistently matching supply to demand in electricity grids. This article considers the possibility of a power outage over a large area of the interconnected electricity transmission system. It also presents how to prevent such a possibility, as well as the remedial actions to follow to prevent a catastrophic event such as a power outage. The safety criteria of the transmission system, the defense plans and the remedial actions that the system operator should prepare to prevent a major power outage are described. First, the major power outages that have occurred in recent years are presented and their causes are examined. In addition, it has been tried to find similarities between the past power cuts in Turkey and the state of the European electricity grid. A transmission failure simulation test environment has been developed to understand the characteristics of realistic transmission level disturbances propagated to the power system and the effects of such disturbances on the performance of conventional conservation and restoration technologies. By using both Black Start units and connection lines from neighboring system operators, it was ensured that restoration time was minimized by creating separate islands that would eventually be synchronized. In the study, a restoration strategy was presented. The proposed strategy has been tested and validated in the IEEE-39 bus system. The results proved the efficiency of the restoration strategy, as the total restoration time was sufficiently short depending on the complexity of each system, and critical loads were primarily fed.
- Open Access
Integration of Machine-Learning Weather Forecasts into Photovoltaic Power Plant Modeling: Analysis of Forecast Accuracy and Energy Output Impact
Accurate forecasting of meteorological parameters is essential for the reliable operation and performance optimization of photovoltaic (PV) power plants. Among these parameters, ambient temperature and global horizontal irradiance (GHI) have the most direct impact on PV output. This study investigates the integration of machine-learning-based (ML) weather forecasts into PV energy modeling and quantifies how forecast accuracy propagates into PV generation estimation errors. Three commonly used ML algorithms—Artificial Neural Networks (ANN), Support Vector Regression (SVR), and Random Forest (RF)—were developed and compared. Antalya (Turkey), representing a Mediterranean climate zone, was selected as the case study location. High-resolution meteorological data from 2018–2023 were used to train and evaluate the forecasting models for prediction horizons from 1 to 10 days. Model performance was assessed using root mean square error (RMSE) and the coefficient of determination (R2). The results indicate that RF provides the highest accuracy for temperature prediction, while ANN demonstrates superior performance for GHI forecasting. The generated forecasts were incorporated into a PV power output simulation using the PVLib library. The analysis reveals that inaccuracies in GHI forecasts have the largest impact on PV energy estimation, whereas temperature forecast errors contribute significantly less. Overall, the study demonstrates the practical benefits of integrating ML-based meteorological forecasting with PV performance modeling and provides guidance on selecting suitable forecasting techniques for renewable energy system planning and optimization.
Open AccessIntegration of Machine-Learning Weather Forecasts into Photovoltaic Power Plant Modeling: Analysis of Forecast Accuracy and Energy Output Impact
Accurate forecasting of meteorological parameters is essential for the reliable operation and performance optimization of photovoltaic (PV) power plants. Among these parameters, ambient temperature and global horizontal irradiance (GHI) have the most direct impact on PV output. This study investigates the integration of machine-learning-based (ML) weather forecasts into PV energy modeling and quantifies how forecast accuracy propagates into PV generation estimation errors. Three commonly used ML algorithms—Artificial Neural Networks (ANN), Support Vector Regression (SVR), and Random Forest (RF)—were developed and compared. Antalya (Turkey), representing a Mediterranean climate zone, was selected as the case study location. High-resolution meteorological data from 2018–2023 were used to train and evaluate the forecasting models for prediction horizons from 1 to 10 days. Model performance was assessed using root mean square error (RMSE) and the coefficient of determination (R2). The results indicate that RF provides the highest accuracy for temperature prediction, while ANN demonstrates superior performance for GHI forecasting. The generated forecasts were incorporated into a PV power output simulation using the PVLib library. The analysis reveals that inaccuracies in GHI forecasts have the largest impact on PV energy estimation, whereas temperature forecast errors contribute significantly less. Overall, the study demonstrates the practical benefits of integrating ML-based meteorological forecasting with PV performance modeling and provides guidance on selecting suitable forecasting techniques for renewable energy system planning and optimization.
- Open Access
- 1 January 2026
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 20 (1) , e70347
A Scalable and Unified Framework for Optimal Black Start Placement and Restoration Path Selection in Large‐Scale Power Systems: The Hybrid ACO‐A* Approach
Power system restoration (PSR) is a time‐critical and complex combinatorial optimization problem, particularly in the transmission path selection phase following a blackout. When applied to large‐scale power grids, traditional metaheuristic algorithms often suffer from slow convergence and entrapment in local optima. To address these limitations, this paper proposes a novel hybrid ACO‐A* algorithm, which embeds the deterministic A* search heuristic into the probabilistic transition rules of ant colony optimization (ACO). A comprehensive comparative analysis is conducted against the standard genetic algorithm (GA), standard ACO, hybrid GA‐A*, Dijkstra shortest path and mixed‐integer linear programming (MILP) via the IEEE 39‐, 68‐ and 118‐bus test systems. The methodology incorporates a hierarchical Dijkstra‐based subsystem partitioning strategy to decompose complex networks into manageable restoration zones. All restoration paths are validated using AC power flow analysis to ensure voltage, thermal and transient stability constraints are satisfied. The simulation results demonstrate that the proposed hybrid ACO‐A* significantly outperforms other methods, achieving a 100% success rate and reducing computation time by approximately 69% compared with standard ACO on the IEEE 118‐bus system, demonstrating favourable scaling characteristics. The method shows potential for online decision support pending validation on utility‐scale systems. Furthermore, this study extends the algorithm's application to strategic infrastructure planning, identifying optimal black‐start (BS) unit locations that reduce the total system restoration impedance by 18% compared with betweenness‐centrality‐based approaches. Statistical validation using 20 independent runs per test case confirms result robustness. The findings demonstrate that the hybrid ACO‐A* is a robust, scalable and superior solver for both operational recovery and resilience planning.
- 1 January 2026
- Published by Institution of Engineering and Technology (IET) in IET Generation, Transmission & Distribution
- Vol. 20 (1) , e70347
Open AccessA Scalable and Unified Framework for Optimal Black Start Placement and Restoration Path Selection in Large‐Scale Power Systems: The Hybrid ACO‐A* Approach
Power system restoration (PSR) is a time‐critical and complex combinatorial optimization problem, particularly in the transmission path selection phase following a blackout. When applied to large‐scale power grids, traditional metaheuristic algorithms often suffer from slow convergence and entrapment in local optima. To address these limitations, this paper proposes a novel hybrid ACO‐A* algorithm, which embeds the deterministic A* search heuristic into the probabilistic transition rules of ant colony optimization (ACO). A comprehensive comparative analysis is conducted against the standard genetic algorithm (GA), standard ACO, hybrid GA‐A*, Dijkstra shortest path and mixed‐integer linear programming (MILP) via the IEEE 39‐, 68‐ and 118‐bus test systems. The methodology incorporates a hierarchical Dijkstra‐based subsystem partitioning strategy to decompose complex networks into manageable restoration zones. All restoration paths are validated using AC power flow analysis to ensure voltage, thermal and transient stability constraints are satisfied. The simulation results demonstrate that the proposed hybrid ACO‐A* significantly outperforms other methods, achieving a 100% success rate and reducing computation time by approximately 69% compared with standard ACO on the IEEE 118‐bus system, demonstrating favourable scaling characteristics. The method shows potential for online decision support pending validation on utility‐scale systems. Furthermore, this study extends the algorithm's application to strategic infrastructure planning, identifying optimal black‐start (BS) unit locations that reduce the total system restoration impedance by 18% compared with betweenness‐centrality‐based approaches. Statistical validation using 20 independent runs per test case confirms result robustness. The findings demonstrate that the hybrid ACO‐A* is a robust, scalable and superior solver for both operational recovery and resilience planning.
- Open Access
- 1 January 2026
- Published by Wiley in International Journal of Photoenergy
- Vol. 2026 (1)
Evaluation of Machine Learning Algorithms for Weather Forecasting in Two Climatic Zones for Solar PV Modeling
Accurate weather forecasting is a key requirement for the reliable operation and optimization of renewable energy systems, particularly solar photovoltaic (PV) installations. This study presents a comparative evaluation of three widely used machine learning algorithms—artificial neural networks (ANN), support vector regression (SVR), and random forest (RF)—for forecasting three critical meteorological parameters: ambient temperature, wind speed at 10 m, and global horizontal irradiance (GHI). Two climatically distinct cities were selected as case studies: Antalya (Turkey), representing a Mediterranean climate, and Cheboksary (Russia), representing a temperate continental climate. Using high‐resolution weather datasets spanning from 2018 to 2023, the models were trained and tested for forecast horizons ranging from 1 to 10 days. The model performance was assessed using three standard evaluation metrics: root mean square error (RMSE), mean absolute error (MAE), and the coefficient of determination ( R 2 ). The results demonstrate that RF provided the lowest prediction error for temperature and wind speed across both locations, whereas ANN yielded the most accurate forecasts for GHI. Moreover, paired forecasts involving temperature and GHI showed the highest R 2 values using ANN (0.968 and 0.948), and RF showed optimal accuracy for temperature and wind speed pairs (0.975 and 0.967). The findings underscore the importance of algorithm–climate interaction and offer insights for model selection in hybrid renewable energy system modeling.
- 1 January 2026
- Published by Wiley in International Journal of Photoenergy
- Vol. 2026 (1)
Open AccessEvaluation of Machine Learning Algorithms for Weather Forecasting in Two Climatic Zones for Solar PV Modeling
Accurate weather forecasting is a key requirement for the reliable operation and optimization of renewable energy systems, particularly solar photovoltaic (PV) installations. This study presents a comparative evaluation of three widely used machine learning algorithms—artificial neural networks (ANN), support vector regression (SVR), and random forest (RF)—for forecasting three critical meteorological parameters: ambient temperature, wind speed at 10 m, and global horizontal irradiance (GHI). Two climatically distinct cities were selected as case studies: Antalya (Turkey), representing a Mediterranean climate, and Cheboksary (Russia), representing a temperate continental climate. Using high‐resolution weather datasets spanning from 2018 to 2023, the models were trained and tested for forecast horizons ranging from 1 to 10 days. The model performance was assessed using three standard evaluation metrics: root mean square error (RMSE), mean absolute error (MAE), and the coefficient of determination ( R 2 ). The results demonstrate that RF provided the lowest prediction error for temperature and wind speed across both locations, whereas ANN yielded the most accurate forecasts for GHI. Moreover, paired forecasts involving temperature and GHI showed the highest R 2 values using ANN (0.968 and 0.948), and RF showed optimal accuracy for temperature and wind speed pairs (0.975 and 0.967). The findings underscore the importance of algorithm–climate interaction and offer insights for model selection in hybrid renewable energy system modeling.
- Open Access
- 23 November 2025
- Published by Wiley in International Wound Journal
- Vol. 22 (11) , e70792
Determination of Hemodynamic Response Using fNIRS in Lower Extremity Amputee and Replant Patients
This study investigates cortical reorganisation and hemodynamic responses in individuals with lower extremity amputation and replantation using functional near‐infrared spectroscopy (fNIRS). A total of 15 healthy controls, four left lower limb amputees and one replantation patient were included. Oxyhemoglobin (oxy‐Hb) activations were measured during 10 unilateral lower limb motor tasks (toe, ankle, knee and hip movements). Non‐parametric analyses revealed significant differences in cortical activation between amputees and controls, particularly during knee flexion and extension. Three‐dimensional contrast maps demonstrated that oxy‐Hb activity in amputees extended from the M1‐leg area into somatosensory regions, reflecting neuroplastic remapping. In contrast, the replantation patient exhibited activation patterns closer to the control group, especially in knee and hip tasks. These findings indicate that fNIRS can sensitively capture hemispheric dynamics during unilateral lower limb movements and highlight neuroplastic adaptations following amputation and replantation. Such insights may guide future neuroprosthetic design and rehabilitation strategies.
- 23 November 2025
- Published by Wiley in International Wound Journal
- Vol. 22 (11) , e70792
Open AccessDetermination of Hemodynamic Response Using fNIRS in Lower Extremity Amputee and Replant Patients
This study investigates cortical reorganisation and hemodynamic responses in individuals with lower extremity amputation and replantation using functional near‐infrared spectroscopy (fNIRS). A total of 15 healthy controls, four left lower limb amputees and one replantation patient were included. Oxyhemoglobin (oxy‐Hb) activations were measured during 10 unilateral lower limb motor tasks (toe, ankle, knee and hip movements). Non‐parametric analyses revealed significant differences in cortical activation between amputees and controls, particularly during knee flexion and extension. Three‐dimensional contrast maps demonstrated that oxy‐Hb activity in amputees extended from the M1‐leg area into somatosensory regions, reflecting neuroplastic remapping. In contrast, the replantation patient exhibited activation patterns closer to the control group, especially in knee and hip tasks. These findings indicate that fNIRS can sensitively capture hemispheric dynamics during unilateral lower limb movements and highlight neuroplastic adaptations following amputation and replantation. Such insights may guide future neuroprosthetic design and rehabilitation strategies.
- Open Access
- 20 March 2025
- Published by Muhendislik Bilimleri ve Tasarim Dergisi in Mühendislik Bilimleri ve Tasarım Dergisi
- Vol. 13 (1) , 286-305
YILDIRIM KAYNAKLI ENERJİ İLETİM HATTI ARIZALARININ İZOLATÖR BOYU VE TOPRAKLAMA DİRENCİ AÇISINDAN SINIR DEĞERLERİNİN BELİRLENMESİ
Yıldırım, doğanın en etkileyici fiziksel fenomenlerinden biri olarak, yüksek enerjiye sahip elektriksel boşalma olarak tanımlanabilir. Dünya üzerinde 3 milyar yıldan beri var olduğu düşünülen ve kontrolsüz elektrik hareketi olarak özetlenebilecek yıldırım, havai enerji iletim hatları için en büyük arıza kaynağıdır. Bu çalışmada işletmede bulunan ve yıllık bazda en fazla yıldırım alan mevcut enerji iletim hattı karakter özellikleriyle (direk temel topraklama direnci, izolatör boyu, koruma iletken tipi, iletken tipi) Bergeron Yöntemi ile PSCAD kullanılarak modellenmiştir. Meteoroloji Bölge Müdürlüğü’nden alınan yıldırım verilerine göre hangi yıldırım şiddetinde hatta arızanın meydana geldiği ve hattın enerjisiz kaldığı belirlenmiştir. Hattın işletmecisinden mesafe koruma rölesi arıza bilgileri alınarak arızanın oluştuğu direk belirlenmiştir. Bu veriler ışığında hazırlanan modele değişik akım şiddetlerinde yıldırım enjekte edilerek, yıldırım akım şiddeti, direk topraklama direnci ve izolatör boyu arasında korelasyon elde edilmiştir. Bu korelasyon sonucunda yıldırım akım şiddetine bağlı olarak, hangi izolatör boyunda ve direk toprak değerinde hatların enerjisiz kalıp kalmayacağı belirlenmiştir.
- 20 March 2025
- Published by Muhendislik Bilimleri ve Tasarim Dergisi in Mühendislik Bilimleri ve Tasarım Dergisi
- Vol. 13 (1) , 286-305
Open AccessYILDIRIM KAYNAKLI ENERJİ İLETİM HATTI ARIZALARININ İZOLATÖR BOYU VE TOPRAKLAMA DİRENCİ AÇISINDAN SINIR DEĞERLERİNİN BELİRLENMESİ
Yıldırım, doğanın en etkileyici fiziksel fenomenlerinden biri olarak, yüksek enerjiye sahip elektriksel boşalma olarak tanımlanabilir. Dünya üzerinde 3 milyar yıldan beri var olduğu düşünülen ve kontrolsüz elektrik hareketi olarak özetlenebilecek yıldırım, havai enerji iletim hatları için en büyük arıza kaynağıdır. Bu çalışmada işletmede bulunan ve yıllık bazda en fazla yıldırım alan mevcut enerji iletim hattı karakter özellikleriyle (direk temel topraklama direnci, izolatör boyu, koruma iletken tipi, iletken tipi) Bergeron Yöntemi ile PSCAD kullanılarak modellenmiştir. Meteoroloji Bölge Müdürlüğü’nden alınan yıldırım verilerine göre hangi yıldırım şiddetinde hatta arızanın meydana geldiği ve hattın enerjisiz kaldığı belirlenmiştir. Hattın işletmecisinden mesafe koruma rölesi arıza bilgileri alınarak arızanın oluştuğu direk belirlenmiştir. Bu veriler ışığında hazırlanan modele değişik akım şiddetlerinde yıldırım enjekte edilerek, yıldırım akım şiddeti, direk topraklama direnci ve izolatör boyu arasında korelasyon elde edilmiştir. Bu korelasyon sonucunda yıldırım akım şiddetine bağlı olarak, hangi izolatör boyunda ve direk toprak değerinde hatların enerjisiz kalıp kalmayacağı belirlenmiştir.
- Open Access
- 24 January 2025
- Published by Wiley in Wind Energy
- Vol. 28 (2)
Volt/VAr Regulation of the West Mediterranean Regional Electrical Grids Using SVC/STATCOM Devices With Neural Network Algorithms
Reactive power compensation is now a challenging issue in maintaining adequate power quality and improving the performance of the transmission system. Many researchers have focused on the behavior of voltage in the unbalanced state, and the majority of the studies have been done with STATCOM. In this study, the increasing power demand in power grids and the challenges associated with maintaining power quality and stability are discussed. The power system in the western Mediterranean region of Turkey is modeled with the DigSILENT Power Factory program using real data. It highlights the importance of reactive power compensation and introduces FACTS devices as a solution to control power factors and reactive power in the grid. In the realistic model, voltage and reactive power regulation is achieved by using SVC and STATCOM devices to ensure voltage stability. A load flow and short circuit analysis is performed on the designed transmission system for a number of critical scenarios. The modeled power system is optimized for the size and location of the FACTS devices by applying genetic algorithms (GAs) and particle swarm optimization (PSO) algorithms to the selected busbars of the FACTS devices, a strategy designed to significantly reduce system losses. The load values used in the heuristics differ from those used in other studies in that they use a realistic load profile that varies randomly and instantaneously over the long term, as opposed to a fixed load profile. All the comparative results show that the STATCOM controller can maintain the most significant reduction in technical losses and excellent performance in controlling the reactive power response under various outages. The effectiveness of the proposed methodology has been validated in various outage scenarios, and it has been shown that it will reduce the total cost of electricity generation in the western Mediterranean region on an annual basis. Considering the results of the Turkish National Transmission System, increasing voltage sensitivity and reactive power control can be beneficial in reducing power transmission costs and maintaining the balance between generation and consumption.
- 24 January 2025
- Published by Wiley in Wind Energy
- Vol. 28 (2)
Open AccessVolt/VAr Regulation of the West Mediterranean Regional Electrical Grids Using SVC/STATCOM Devices With Neural Network Algorithms
Reactive power compensation is now a challenging issue in maintaining adequate power quality and improving the performance of the transmission system. Many researchers have focused on the behavior of voltage in the unbalanced state, and the majority of the studies have been done with STATCOM. In this study, the increasing power demand in power grids and the challenges associated with maintaining power quality and stability are discussed. The power system in the western Mediterranean region of Turkey is modeled with the DigSILENT Power Factory program using real data. It highlights the importance of reactive power compensation and introduces FACTS devices as a solution to control power factors and reactive power in the grid. In the realistic model, voltage and reactive power regulation is achieved by using SVC and STATCOM devices to ensure voltage stability. A load flow and short circuit analysis is performed on the designed transmission system for a number of critical scenarios. The modeled power system is optimized for the size and location of the FACTS devices by applying genetic algorithms (GAs) and particle swarm optimization (PSO) algorithms to the selected busbars of the FACTS devices, a strategy designed to significantly reduce system losses. The load values used in the heuristics differ from those used in other studies in that they use a realistic load profile that varies randomly and instantaneously over the long term, as opposed to a fixed load profile. All the comparative results show that the STATCOM controller can maintain the most significant reduction in technical losses and excellent performance in controlling the reactive power response under various outages. The effectiveness of the proposed methodology has been validated in various outage scenarios, and it has been shown that it will reduce the total cost of electricity generation in the western Mediterranean region on an annual basis. Considering the results of the Turkish National Transmission System, increasing voltage sensitivity and reactive power control can be beneficial in reducing power transmission costs and maintaining the balance between generation and consumption.
- Open Access
- 21 January 2025
- Published by Walter de Gruyter GmbH in B&H Electrical Engineering
- Vol. 20 (1) , 109-116
The Voltage Regulation of Power Systems Using STATCOM and Battery Energy Storage System: a Simulation Study
Power plants must have sufficient installed power capacity to accomplish high demand and must be operated continuously with sufficient capability to meet real-time demand. Integrating an energy storage system, such as a battery energy storage system, into a Flexible Alternating Current Transmission System (FACTS) device can provide the much-needed flexibility to reduce dynamic decentralized active power capabilities and transmission-level power flow issues. This article establishes a control strategy for optimal use of STATCOM and the Battery energy storage system. The architecture of the BESS, its utility-scale applications and the benefits of its application in power systems have been studied, as well as the operation control methods of large-scale STATCOM and BESS systems have been examined. Application scenarios such as power grid frequency tuning and power flow optimization are presented. In addition, in the study where STATCOM and BESS are integrated into the power system, specific features to support voltage in power grids are demonstrated. STATCOM and BESS units have been shown to be integrated and improved with optimum power factors. To reduce energy loss and improve voltage stability, STATCOM has been validated to simultaneously improve the voltage profile in the interconnected grid by regulating the active and reactive power in the power transmission line. Finally, all the comparative results show that STATCOM and BESS devices can maintain excellent performance in controlling the voltage regulation response under various faults. The results were considered considering the current Turkish interconnection system, with a view to identifying potential avenues for enhancement.
- 21 January 2025
- Published by Walter de Gruyter GmbH in B&H Electrical Engineering
- Vol. 20 (1) , 109-116
Open AccessThe Voltage Regulation of Power Systems Using STATCOM and Battery Energy Storage System: a Simulation Study
Power plants must have sufficient installed power capacity to accomplish high demand and must be operated continuously with sufficient capability to meet real-time demand. Integrating an energy storage system, such as a battery energy storage system, into a Flexible Alternating Current Transmission System (FACTS) device can provide the much-needed flexibility to reduce dynamic decentralized active power capabilities and transmission-level power flow issues. This article establishes a control strategy for optimal use of STATCOM and the Battery energy storage system. The architecture of the BESS, its utility-scale applications and the benefits of its application in power systems have been studied, as well as the operation control methods of large-scale STATCOM and BESS systems have been examined. Application scenarios such as power grid frequency tuning and power flow optimization are presented. In addition, in the study where STATCOM and BESS are integrated into the power system, specific features to support voltage in power grids are demonstrated. STATCOM and BESS units have been shown to be integrated and improved with optimum power factors. To reduce energy loss and improve voltage stability, STATCOM has been validated to simultaneously improve the voltage profile in the interconnected grid by regulating the active and reactive power in the power transmission line. Finally, all the comparative results show that STATCOM and BESS devices can maintain excellent performance in controlling the voltage regulation response under various faults. The results were considered considering the current Turkish interconnection system, with a view to identifying potential avenues for enhancement.
- Open Access
- 31 December 2024
- Published by AVES YAYINCILIK A.Ş. in Archives of Rheumatology
- Vol. 39 (4) , 617-623
A comparison of thermal characteristics of the small joints of the hands between patients with rheumatoid arthritis and healthy controls
Objectives: This study aims to investigate the thermal characteristics of the small joints of the hands between patients with rheumatoid arthritis (RA) and healthy controls. Patients and methods: Between December 2020 and May 2021, a total of 52 RA patients (9 males, 43 females; mean age: 52.1±11.1 years; range, 38 to 68 years) who met the revised American College of Rheumatology and European League Against Rheumatism (ACR/EULAR) classification criteria and 26 healthy controls (10 males, 16 females; mean age: 51.2±8.2 years; range, 38 to 68 years) were included. Joint tenderness was evaluated using Ritchie articular index (RAI). Joint tenderness was scored from 0 to 3. Thermal data were collected from the hand regions of individuals. A FLIR T450sc microbolometer infrared thermal camera with 320×240 resolution was used for the thermography of individuals. Bilaterally proximal interphalangeal joints (1-5) and metacarpophalangeal joints (1-5) were evaluated. The mean temperature was compared between the patients and healthy controls. Results: The mean disease duration of patients with RA was 10.4±8.9 years. The mean temperature values of the joints in the patients with a RA RAI score of 0, 1, 2, 3 were 32.43±1.59°C; 32.71±1.36°C; 33.12±1.23°C; 33.60±0.99°C, respectively. The mean temperature was 31.14±1.51°C in healthy controls. The mean temperature values of the joints in the RA patients with RAI score of 0 was higher compared to healthy controls (p
- 31 December 2024
- Published by AVES YAYINCILIK A.Ş. in Archives of Rheumatology
- Vol. 39 (4) , 617-623
Open AccessA comparison of thermal characteristics of the small joints of the hands between patients with rheumatoid arthritis and healthy controls
Objectives: This study aims to investigate the thermal characteristics of the small joints of the hands between patients with rheumatoid arthritis (RA) and healthy controls. Patients and methods: Between December 2020 and May 2021, a total of 52 RA patients (9 males, 43 females; mean age: 52.1±11.1 years; range, 38 to 68 years) who met the revised American College of Rheumatology and European League Against Rheumatism (ACR/EULAR) classification criteria and 26 healthy controls (10 males, 16 females; mean age: 51.2±8.2 years; range, 38 to 68 years) were included. Joint tenderness was evaluated using Ritchie articular index (RAI). Joint tenderness was scored from 0 to 3. Thermal data were collected from the hand regions of individuals. A FLIR T450sc microbolometer infrared thermal camera with 320×240 resolution was used for the thermography of individuals. Bilaterally proximal interphalangeal joints (1-5) and metacarpophalangeal joints (1-5) were evaluated. The mean temperature was compared between the patients and healthy controls. Results: The mean disease duration of patients with RA was 10.4±8.9 years. The mean temperature values of the joints in the patients with a RA RAI score of 0, 1, 2, 3 were 32.43±1.59°C; 32.71±1.36°C; 33.12±1.23°C; 33.60±0.99°C, respectively. The mean temperature was 31.14±1.51°C in healthy controls. The mean temperature values of the joints in the RA patients with RAI score of 0 was higher compared to healthy controls (p