  • Optimal Power Flow Control and Emergency Voltage Control with A Unified Power Flow Controller (UPFC) to Improve The Performance of The Power System

    by Hamza Feza Carlak, Ergin Kayar

    The increasing global energy demand has intensified pressure on existing transmission infrastructure, giving rise to thermal overloads, voltage instability, and elevated power losses. Flexible Alternating Current Transmission System (FACTS) devices have emerged as a technically viable solution to enhance the controllability and power transfer capability of existing networks without significant infrastructural expansion. Among FACTS controllers, the Unified Power Flow Controller (UPFC) is distinguished as the most versatile device, capable of regulating active power flow, reactive power flow, and bus voltage magnitude simultaneously. This paper presents a comprehensive simulation study of UPFC performance using the IEEE 9-bus benchmark transmission network, which was modeled in DIgSILENT PowerFactory. The voltage stability indices and line stability factors identify Bus 8 as the optimal point for UPFC installation. Four simulation scenarios are investigated: the base case without UPFC, UPFC integrated at Bus 8 under normal full-load conditions, N-1 line contingency with three compensation strategies compared, and a generator outage response. The findings indicate that the integration of UPFC results in a 19.64% decrease in active power losses and a 32.74% decrease in reactive power losses. In the context of the N-1 line contingency, the uncompensated system permits a voltage collapse of Bus 8 to 0.909 pu. However, UPFC effectively restores the voltage to above 1.020 pu within approximately 20 seconds, thereby demonstrating a substantial performance enhancement in comparison to the fixed capacitor bank compensation. During generator outages, the UPFC has been shown to limit the Bus 7 voltage dip to 0.986 pu with rapid stabilization in comparison to a sustained depression to 0.967 pu without compensation. The findings confirm the technical superiority of UPFC as a multi-functional FACTS controller for modernizing voltage-constrained transmission networks.

  • Open Access

    A Scalable and Unified Framework for Optimal Black Start Placement and Restoration Path Selection in Large‐Scale Power Systems: The Hybrid ACO‐A* Approach

    by Ergin Kayar, H. Feza Carlak

    Power system restoration (PSR) is a time‐critical and complex combinatorial optimization problem, particularly in the transmission path selection phase following a blackout. When applied to large‐scale power grids, traditional metaheuristic algorithms often suffer from slow convergence and entrapment in local optima. To address these limitations, this paper proposes a novel hybrid ACO‐A* algorithm, which embeds the deterministic A* search heuristic into the probabilistic transition rules of ant colony optimization (ACO). A comprehensive comparative analysis is conducted against the standard genetic algorithm (GA), standard ACO, hybrid GA‐A*, Dijkstra shortest path and mixed‐integer linear programming (MILP) via the IEEE 39‐, 68‐ and 118‐bus test systems. The methodology incorporates a hierarchical Dijkstra‐based subsystem partitioning strategy to decompose complex networks into manageable restoration zones. All restoration paths are validated using AC power flow analysis to ensure voltage, thermal and transient stability constraints are satisfied. The simulation results demonstrate that the proposed hybrid ACO‐A* significantly outperforms other methods, achieving a 100% success rate and reducing computation time by approximately 69% compared with standard ACO on the IEEE 118‐bus system, demonstrating favourable scaling characteristics. The method shows potential for online decision support pending validation on utility‐scale systems. Furthermore, this study extends the algorithm's application to strategic infrastructure planning, identifying optimal black‐start (BS) unit locations that reduce the total system restoration impedance by 18% compared with betweenness‐centrality‐based approaches. Statistical validation using 20 independent runs per test case confirms result robustness. The findings demonstrate that the hybrid ACO‐A* is a robust, scalable and superior solver for both operational recovery and resilience planning.

  • Open Access

    Volt/VAr Regulation of the West Mediterranean Regional Electrical Grids Using SVC/STATCOM Devices With Neural Network Algorithms

    by H. Feza Carlak, Ergin Kayar

    Reactive power compensation is now a challenging issue in maintaining adequate power quality and improving the performance of the transmission system. Many researchers have focused on the behavior of voltage in the unbalanced state, and the majority of the studies have been done with STATCOM. In this study, the increasing power demand in power grids and the challenges associated with maintaining power quality and stability are discussed. The power system in the western Mediterranean region of Turkey is modeled with the DigSILENT Power Factory program using real data. It highlights the importance of reactive power compensation and introduces FACTS devices as a solution to control power factors and reactive power in the grid. In the realistic model, voltage and reactive power regulation is achieved by using SVC and STATCOM devices to ensure voltage stability. A load flow and short circuit analysis is performed on the designed transmission system for a number of critical scenarios. The modeled power system is optimized for the size and location of the FACTS devices by applying genetic algorithms (GAs) and particle swarm optimization (PSO) algorithms to the selected busbars of the FACTS devices, a strategy designed to significantly reduce system losses. The load values used in the heuristics differ from those used in other studies in that they use a realistic load profile that varies randomly and instantaneously over the long term, as opposed to a fixed load profile. All the comparative results show that the STATCOM controller can maintain the most significant reduction in technical losses and excellent performance in controlling the reactive power response under various outages. The effectiveness of the proposed methodology has been validated in various outage scenarios, and it has been shown that it will reduce the total cost of electricity generation in the western Mediterranean region on an annual basis. Considering the results of the Turkish National Transmission System, increasing voltage sensitivity and reactive power control can be beneficial in reducing power transmission costs and maintaining the balance between generation and consumption.


  • Open Access

    Volt / VAR Regulation in Energy Transmission Systems Using SVC and STATCOM Devices

    by Hamza Feza Carlak, Ergin Kayar

    To ensure energy continuity in the interconnected power systems, production and consumption amounts should be in balance, and that can be possible by providing constant voltage and frequency. Otherwise, undesirable large dynamic oscillations, voltage collapse may occur, and the quality of the electrical energy deteriorates. In this study, the power system of the Denizli Region in the Western Mediterranean Region is modeled using realistic national data. The simulation study is carried out to obtain the voltages, active and reactive powers of buses in the case of no-fault and fault occurrence. Using FACTS (Flexible Alternating Current Transmission Systems) technology such as SVC and STATCOM, the power systems can be controlled, and the carrying capacities can be improved within specified limits. Facts devices are capable of producing and consuming reactive power depending on immediate needs, safe and operating flexibility, and having a high reaction time in the simulation studies. The maximum load limits are increased, and the control of the power system is facilitated. STATCOM provides 31.09 % more achievement with respect to SVC device at energy production and consumption rates for the modeled pilot region. The reliability of the power system has been increased against a voltage collapse, thanks to the SVC and STATCOM controllers. Furthermore, the voltage stability of the generator is also raised, and correspondingly the capacity of the power system enhances. The results are compared to the existing system, and the obtained improvements may be assessed for the enhancement of the interconnected network grid of Turkey.


  • Voltage Regulation Analysis in Energy Transmission Systems Using STATCOM

    by Hamza Feza Carlak, Ergin Kayar

    Due to the difficulties to insert new power transmission lines, dramatic increases in electricity demand, and proceeding the stability of power systems turns out to be the most critical and challenging problem. Modeling of the energy transmission system is performed for the pilot region to optimize controllable parameters of the power system to maintain energy quality at the most appropriate value. The simulation study is implemented for the Denizli western region energy transmission system with realistic values. The load flow analysis of the system has been carried out by using DigSilent power system analysis software. The control of voltage fluctuations of the national electric energy network system by the help of FACTS (Flexible Alternating Current Transmission Systems) technology is carried out with the proposed method using real national data for the pilot region, and the results are compared with the existing network system. The usage of STATCOM (Static Synchronous Compensators) controllers which are a part of a new control system called FACTS, and capacitor banks are compared for the dynamic power system model, and the results of each device are presented in the study. The STATCOM has a very high reaction time and operates in a wide range depending on their capacity and provides more flexible and safe operation. Moreover, the maximum load limits can be increased, and the control of the power system may be facilitated utilizing the STATCOM devices.