Véronique Feipel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Véronique Feipel has a total of 214 co-authors. Here are the top co-authors by number of shared publications:
Marcel Rooze
Université Libre de Bruxelles, Brussels, Belgium; Laboratory of Functional Anatomy, Faculty of Motor Sciences, Université Libre de Bruxelles, Brussels, Belgium; Laboratory of Anatomy, Biomechanics and Organogenesis, Université Libre de Bruxelles, Brussels, Belgium
17 shared publications- Serge Van Sint Jan
Laboratory of Anatomy, Biomechanics and Organogenesis (LABO), Université Libre de Bruxelles, Brussels, Belgium
15 shared publications - Benoît Beyer
National Museum of Natural Sciences
14 shared publications M. Rooze
Laboratory of Anatomy, Biomechanics and Organogenesis, Université Libre de Bruxelles (ULB), Bruxelles, Belgium; Laboratory of Functional Anatomy, Université Libre de Bruxelles, Bruxelles, Belgium; Department of Orthopedic Surgery, Erasme Hospital, Université Libre de Bruxelles, Bruxelles, Belgium
13 shared publications- Patrick Salvia
Université Libre de Bruxelles, Laboratories of Anatomy , Belgium
12 shared publications Patrick Salvia
Laboratory of Anatomy, Biomechanics and Organogenesis, Faculty of Medicine, Université Libre de Bruxelles, Brussels, Belgium
10 shared publications
Latest Publications
- 15 September 2026
- Published by Elsevier in Annals of Anatomy - Anatomischer Anzeiger
- Vol. 269
Anatomical-histological study of the Achilles tendon: The search for subtendons
- 15 September 2026
- Published by Elsevier in Annals of Anatomy - Anatomischer Anzeiger
- Vol. 269
Anatomical-histological study of the Achilles tendon: The search for subtendons
- Open Access
- 15 July 2026
- Published by Wiley in Methods in Ecology and Evolution
- Vol. 17 (9) , 2616-2628
A 4D geometric morphometrics workflow to quantify complex biological motion
Quantifying biological motion is fundamentally tied to quantifying the biological structures that produce that motion. Yet, this dependence makes it essential to decouple motion from static morphology to enable general, comparable analyses across individuals and conditions. In this work, we present a methodological pipeline to study biological motion data obtained from experimental motion capture of human breathing kinematics before and after maximal exercise (gold‐standard optoelectronic plethysmography markers). We used four‐dimensional geometric morphometrics (4DGM; 3D shape through time) to characterize breathing patterns while standardizing torso shape and expiratory and inspiratory times. Results showed not only differences in breathing pattern before and after maximal exercise, but also differences in motion pattern associated with BMI and torso shape. Specifically, we found higher thoracoabdominal asynchrony in low‐BMI subjects compared with high‐BMI subjects. We also found a strong covariation between torso shape and the 3D trajectory of motion, demonstrating the power of the method to detect a shape‐to‐function signal even with a small sample size. This method is proposed as a flexible tool to separate biological motion from its underlying structure, which is particularly useful for studying complex systems. In the case of breathing pattern, it is proposed to investigate possible applications in clinical settings to test whether it detects differences between healthy and pathological kinematics, in sport sciences to attempt to link respiratory function to performance, and in evolutionary studies as a possible tool for inferring respiratory function in extinct morphologies.
- 15 July 2026
- Published by Wiley in Methods in Ecology and Evolution
- Vol. 17 (9) , 2616-2628
Open AccessA 4D geometric morphometrics workflow to quantify complex biological motion
Quantifying biological motion is fundamentally tied to quantifying the biological structures that produce that motion. Yet, this dependence makes it essential to decouple motion from static morphology to enable general, comparable analyses across individuals and conditions. In this work, we present a methodological pipeline to study biological motion data obtained from experimental motion capture of human breathing kinematics before and after maximal exercise (gold‐standard optoelectronic plethysmography markers). We used four‐dimensional geometric morphometrics (4DGM; 3D shape through time) to characterize breathing patterns while standardizing torso shape and expiratory and inspiratory times. Results showed not only differences in breathing pattern before and after maximal exercise, but also differences in motion pattern associated with BMI and torso shape. Specifically, we found higher thoracoabdominal asynchrony in low‐BMI subjects compared with high‐BMI subjects. We also found a strong covariation between torso shape and the 3D trajectory of motion, demonstrating the power of the method to detect a shape‐to‐function signal even with a small sample size. This method is proposed as a flexible tool to separate biological motion from its underlying structure, which is particularly useful for studying complex systems. In the case of breathing pattern, it is proposed to investigate possible applications in clinical settings to test whether it detects differences between healthy and pathological kinematics, in sport sciences to attempt to link respiratory function to performance, and in evolutionary studies as a possible tool for inferring respiratory function in extinct morphologies.
- Open Access
- 20 June 2026
- Published by Elsevier in Continence Reports
- Vol. 19
Sexual violence and sexual health outcomes among women in the Democratic Republic of the Congo: a multicenter cross-sectional study
- 20 June 2026
- Published by Elsevier in Continence Reports
- Vol. 19
Open AccessSexual violence and sexual health outcomes among women in the Democratic Republic of the Congo: a multicenter cross-sectional study
- Open Access
- 11 May 2026
- Published by MDPI AG in Biomechanics
- Vol. 6 (2) , 47
The A-Palp: A Digitized Manual Palpation Method for Sagittal Spine Assessment—A Study of Reliability over Time and Between Operators
Background/Objectives: The A-Palp enables a calibrated anatomical systems technique (CAST) approach. Previous studies have demonstrated repeatability and concurrent validity for selected spinal curvature angles in patients with scoliosis. However, the inter-operator reproducibility, temporal repeatability, and reliability of sagittal spinal curvature measurements and spinopelvic parameters remain to be established. Methods: Eighteen healthy adults without spinal pathology were assessed. Two operators sampled sagittal spinal profiles with the A-Palp in a 14-camera optoelectronic setup, applying reflective markers and palpating spinous processes. One operator repeated measurements after seven days. Marker data were processed in MATLAB (R2019b) to smooth trajectories, fit curvature arcs, and compute extracorporeal kyphosis, lordosis, and pelvic parameters. Reliability and repeatability were evaluated using Bland & Altman analysis, intraclass correlations (ICCs), standard error of measurement (SEM), mean detectable change (MDC95), root-mean-squared errors (RMSEs), and Statistical Parametric Mapping (SPM). Results: Reliability and repeatability were strong. For global spinal angles, ICCs exceeded 0.90 across operators and sessions. The tangent method yielded low SEM (1–2°) and MDC95 (3–6°) values, whereas the circle-fit/trigonometric methods showed larger errors. Most spinopelvic angles had moderate-to-excellent ICCs (0.65–0.98) with SEM/MDC95 values ≈2.1–4.5°/5.9–12.4°. Ground reaction force-referenced distances showed good ICCs and small intra-operator error (SEM: 3.8–4.8 mm; MDC95: 10.7–13.4 mm) but wider inter-session thresholds (SEM: 10.3–11.6 mm; MDC95: 28.6–32.8 mm). Bland & Altman biases were ~0, with narrower limits for the tangent (≈±5°) than circle-fit/trigonometric (≈±8–12°) methods. Curve tracking was consistent (RMSE: 2.7–3.7 mm, <5% amplitude), and SPM detected no point-wise differences. Conclusions: The A-Palp method demonstrated high reliability and repeatability for extracorporeal sagittal spinal and sacro-spinal evaluation. Variability was low across operators and sessions, supporting its use as a robust, non-invasive clinical and research tool.
- 11 May 2026
- Published by MDPI AG in Biomechanics
- Vol. 6 (2) , 47
Open AccessThe A-Palp: A Digitized Manual Palpation Method for Sagittal Spine Assessment—A Study of Reliability over Time and Between Operators
Background/Objectives: The A-Palp enables a calibrated anatomical systems technique (CAST) approach. Previous studies have demonstrated repeatability and concurrent validity for selected spinal curvature angles in patients with scoliosis. However, the inter-operator reproducibility, temporal repeatability, and reliability of sagittal spinal curvature measurements and spinopelvic parameters remain to be established. Methods: Eighteen healthy adults without spinal pathology were assessed. Two operators sampled sagittal spinal profiles with the A-Palp in a 14-camera optoelectronic setup, applying reflective markers and palpating spinous processes. One operator repeated measurements after seven days. Marker data were processed in MATLAB (R2019b) to smooth trajectories, fit curvature arcs, and compute extracorporeal kyphosis, lordosis, and pelvic parameters. Reliability and repeatability were evaluated using Bland & Altman analysis, intraclass correlations (ICCs), standard error of measurement (SEM), mean detectable change (MDC95), root-mean-squared errors (RMSEs), and Statistical Parametric Mapping (SPM). Results: Reliability and repeatability were strong. For global spinal angles, ICCs exceeded 0.90 across operators and sessions. The tangent method yielded low SEM (1–2°) and MDC95 (3–6°) values, whereas the circle-fit/trigonometric methods showed larger errors. Most spinopelvic angles had moderate-to-excellent ICCs (0.65–0.98) with SEM/MDC95 values ≈2.1–4.5°/5.9–12.4°. Ground reaction force-referenced distances showed good ICCs and small intra-operator error (SEM: 3.8–4.8 mm; MDC95: 10.7–13.4 mm) but wider inter-session thresholds (SEM: 10.3–11.6 mm; MDC95: 28.6–32.8 mm). Bland & Altman biases were ~0, with narrower limits for the tangent (≈±5°) than circle-fit/trigonometric (≈±8–12°) methods. Curve tracking was consistent (RMSE: 2.7–3.7 mm, <5% amplitude), and SPM detected no point-wise differences. Conclusions: The A-Palp method demonstrated high reliability and repeatability for extracorporeal sagittal spinal and sacro-spinal evaluation. Variability was low across operators and sessions, supporting its use as a robust, non-invasive clinical and research tool.
- 16 March 2026
- Published by Springer Nature in Surgical and Radiologic Anatomy
- Vol. 48 (1)
Anatomical variations in the relationship between the sciatic nerve and the piriformis muscle: clinical implications
- 16 March 2026
- Published by Springer Nature in Surgical and Radiologic Anatomy
- Vol. 48 (1)
Anatomical variations in the relationship between the sciatic nerve and the piriformis muscle: clinical implications
- Open Access
- 10 January 2026
- Published by MDPI AG in Biomechanics
- Vol. 6 (1) , 11
Kinematic Analysis of the Temporomandibular Joints for Different Head Positions—A Reliability Study
Background/Objectives: Considering that the kinematics of the temporomandibular joints (TMJs) is concomitant with head movements and that temporomandibular joint disorders (TMDs) are frequently associated with neck pain in clinics but seldom or never investigated, the aim of this study was to develop a reliable in vivo measurement protocol of the simultaneous amplitudes of the mandible and of the skull. The development of such a protocol is part of a project to build an accurate kinematic assessment tool for clinicians in the orofacial field who treat patients suffering from TMD. Methods: Mouth opening, laterotrusion and protrusion movements for three different positions of the head (neutral, slouched and military) on 12 asymptomatic voluntary subjects (5 men and 7 women, mean 33.6 yo +/− 11.1) were recorded using 20 markers palpated and taped and 14 optoelectronic cameras. The acquisition frequency was set at 150 hertz. The inter- and intra-examiner reliability of marker palpation in mm was calculated using standard deviation (SD), mean difference (MD) and standard error (SE). Amplitudes of movement according to axes defined by the International Society of Biomechanics (ISB) are given for the mandible and skull segments. The propagation of error on the amplitudes was calculated with the root mean square propagation error (RMSPE) in degrees. Repeated-measures ANOVA or Friedman tests were used to assess the influence of the position of the head on the amplitudes of the jaw. Power analysis of the sample size was estimated with Cohen’s f3 size effect test. Steady-state plots (SSPs) and normalized motion graphs between the skull and the mandible motion were performed to study the coordination of their maximum amplitude over time. Results: The protocol demonstrated good intra-examiner reliability (1.5 < MD < 5.8; 2.6 < SD < 7.8; 2.0 < SE < 3.8), good inter-examiner reproducibility (0.2 < MD < 4.0; 3.5 < SD < 4.6; 2.0 < SE < 2.5) and small error propagation (0.0 < RMSPE intra < 2.8; 0.0 < RMSPE inter < 1.0). The amplitudes of the jaw and head found during the three types of movements correspond to the values reported in the literature. Head positions did not appear to significantly influence the amplitudes of jaw movements, which could be explained by the power estimation of our sample (Type II error β = 0.692). The participation of head movements in those of the jaw, for all motions and in all positions, was demonstrated and discussed in detail. Conclusions: The accuracy, test–retest reliability, and intra-individual variability of the TMJ kinematic analysis, including head movements, was ensured. The small sample size and the absence of standardized head positions for the subjects limit the scope of the intra- and inter-group analysis results. Given the natural biological and complex coordination of jaw–head movement, the authors consider its evaluation useful in clinical intervention and would like to further develop the present protocol. The next step should be to test the feasibility of its clinical application with a larger group of asymptomatic subjects compared to patients suffering from TMD.
- 10 January 2026
- Published by MDPI AG in Biomechanics
- Vol. 6 (1) , 11
Open AccessKinematic Analysis of the Temporomandibular Joints for Different Head Positions—A Reliability Study
Background/Objectives: Considering that the kinematics of the temporomandibular joints (TMJs) is concomitant with head movements and that temporomandibular joint disorders (TMDs) are frequently associated with neck pain in clinics but seldom or never investigated, the aim of this study was to develop a reliable in vivo measurement protocol of the simultaneous amplitudes of the mandible and of the skull. The development of such a protocol is part of a project to build an accurate kinematic assessment tool for clinicians in the orofacial field who treat patients suffering from TMD. Methods: Mouth opening, laterotrusion and protrusion movements for three different positions of the head (neutral, slouched and military) on 12 asymptomatic voluntary subjects (5 men and 7 women, mean 33.6 yo +/− 11.1) were recorded using 20 markers palpated and taped and 14 optoelectronic cameras. The acquisition frequency was set at 150 hertz. The inter- and intra-examiner reliability of marker palpation in mm was calculated using standard deviation (SD), mean difference (MD) and standard error (SE). Amplitudes of movement according to axes defined by the International Society of Biomechanics (ISB) are given for the mandible and skull segments. The propagation of error on the amplitudes was calculated with the root mean square propagation error (RMSPE) in degrees. Repeated-measures ANOVA or Friedman tests were used to assess the influence of the position of the head on the amplitudes of the jaw. Power analysis of the sample size was estimated with Cohen’s f3 size effect test. Steady-state plots (SSPs) and normalized motion graphs between the skull and the mandible motion were performed to study the coordination of their maximum amplitude over time. Results: The protocol demonstrated good intra-examiner reliability (1.5 < MD < 5.8; 2.6 < SD < 7.8; 2.0 < SE < 3.8), good inter-examiner reproducibility (0.2 < MD < 4.0; 3.5 < SD < 4.6; 2.0 < SE < 2.5) and small error propagation (0.0 < RMSPE intra < 2.8; 0.0 < RMSPE inter < 1.0). The amplitudes of the jaw and head found during the three types of movements correspond to the values reported in the literature. Head positions did not appear to significantly influence the amplitudes of jaw movements, which could be explained by the power estimation of our sample (Type II error β = 0.692). The participation of head movements in those of the jaw, for all motions and in all positions, was demonstrated and discussed in detail. Conclusions: The accuracy, test–retest reliability, and intra-individual variability of the TMJ kinematic analysis, including head movements, was ensured. The small sample size and the absence of standardized head positions for the subjects limit the scope of the intra- and inter-group analysis results. Given the natural biological and complex coordination of jaw–head movement, the authors consider its evaluation useful in clinical intervention and would like to further develop the present protocol. The next step should be to test the feasibility of its clinical application with a larger group of asymptomatic subjects compared to patients suffering from TMD.
- Open Access
- 23 November 2025
- Published by Elsevier in Continence Reports
- Vol. 16
Prevalence and determinants of urinary incontinence among adult women in the Democratic Republic of Congo: a community-based cross-sectional study
- 23 November 2025
- Published by Elsevier in Continence Reports
- Vol. 16
Open AccessPrevalence and determinants of urinary incontinence among adult women in the Democratic Republic of Congo: a community-based cross-sectional study
- 8 July 2025
- Published by Elsevier in Morphologie
- Vol. 109 (366) , 101055
Histological study of the capsular and discal insertions of the lateral pterygoid muscle
- 8 July 2025
- Published by Elsevier in Morphologie
- Vol. 109 (366) , 101055
Histological study of the capsular and discal insertions of the lateral pterygoid muscle
- Open Access
Kinect-Based Gait Analysis System Design and Concurrent Validity in Persons with Anterolateral Shoulder Pain Syndrome, Results from a Pilot Study
As part of an investigation to detect asymmetries in gait patterns in persons with shoulder injuries, the goal of the present study was to design and validate a Kinect-based motion capture system that would enable the extraction of joint kinematics curves during gait and to compare them with the data obtained through a commercial motion capture system. The study included eight male and two female participants, all diagnosed with anterolateral shoulder pain syndrome in their right upper extremity with a minimum 18 months of disorder evolution. The participants had an average age of 31.8 ± 9.8 years, a height of 173 ± 18 cm, and a weight of 81 ± 15 kg. The gait kinematics were sampled simultaneously with the new system and the Clinical 3DMA system. Shoulder, elbow, hip, and knee kinematics were compared between systems for the pathological and non-pathological sides using repeated measures ANOVA and 1D statistical parametric mapping. For most variables, no significant difference was found between systems. Evidence of a significant difference between the newly developed system and the commercial system was found for knee flexion–extension (p < 0.004, between 60 and 80% of the gait cycle), and for shoulder abduction–adduction. The good concurrent validity of the new Kinect-based motion analysis system found in this study opens promising perspectives for clinical motion tracking using an affordable and simple system.
Open AccessKinect-Based Gait Analysis System Design and Concurrent Validity in Persons with Anterolateral Shoulder Pain Syndrome, Results from a Pilot Study
As part of an investigation to detect asymmetries in gait patterns in persons with shoulder injuries, the goal of the present study was to design and validate a Kinect-based motion capture system that would enable the extraction of joint kinematics curves during gait and to compare them with the data obtained through a commercial motion capture system. The study included eight male and two female participants, all diagnosed with anterolateral shoulder pain syndrome in their right upper extremity with a minimum 18 months of disorder evolution. The participants had an average age of 31.8 ± 9.8 years, a height of 173 ± 18 cm, and a weight of 81 ± 15 kg. The gait kinematics were sampled simultaneously with the new system and the Clinical 3DMA system. Shoulder, elbow, hip, and knee kinematics were compared between systems for the pathological and non-pathological sides using repeated measures ANOVA and 1D statistical parametric mapping. For most variables, no significant difference was found between systems. Evidence of a significant difference between the newly developed system and the commercial system was found for knee flexion–extension (p < 0.004, between 60 and 80% of the gait cycle), and for shoulder abduction–adduction. The good concurrent validity of the new Kinect-based motion analysis system found in this study opens promising perspectives for clinical motion tracking using an affordable and simple system.
- Open Access
- 7 July 2023
- Published by AOSIS in South African Journal of Physiotherapy
- Vol. 79 (1) , 7
Psychological consequences of female genital mutilation: A mixed-method systematic review
The South African Journal of Physiotherapy is the official scholarly refereed journal of the South African Society of Physiotherapy. It aims to publish original research and facilitate continuing professional development for physiotherapists and other health professions both nationally and internationally.
- 7 July 2023
- Published by AOSIS in South African Journal of Physiotherapy
- Vol. 79 (1) , 7
Open AccessPsychological consequences of female genital mutilation: A mixed-method systematic review
The South African Journal of Physiotherapy is the official scholarly refereed journal of the South African Society of Physiotherapy. It aims to publish original research and facilitate continuing professional development for physiotherapists and other health professions both nationally and internationally.