The A-Palp: A Digitized Manual Palpation Method for Sagittal Spine Assessment—A Study of Reliability over Time and Between Operators
Open Access
- 11 May 2026
- journal article
- research article
- Published by MDPI AG in Biomechanics
- Vol. 6 (2) , 47
Abstract
Background/Objectives: The A-Palp enables a calibrated anatomical systems technique (CAST) approach. Previous studies have demonstrated repeatability and concurrent validity for selected spinal curvature angles in patients with scoliosis. However, the inter-operator reproducibility, temporal repeatability, and reliability of sagittal spinal curvature measurements and spinopelvic parameters remain to be established. Methods: Eighteen healthy adults without spinal pathology were assessed. Two operators sampled sagittal spinal profiles with the A-Palp in a 14-camera optoelectronic setup, applying reflective markers and palpating spinous processes. One operator repeated measurements after seven days. Marker data were processed in MATLAB (R2019b) to smooth trajectories, fit curvature arcs, and compute extracorporeal kyphosis, lordosis, and pelvic parameters. Reliability and repeatability were evaluated using Bland & Altman analysis, intraclass correlations (ICCs), standard error of measurement (SEM), mean detectable change (MDC95), root-mean-squared errors (RMSEs), and Statistical Parametric Mapping (SPM). Results: Reliability and repeatability were strong. For global spinal angles, ICCs exceeded 0.90 across operators and sessions. The tangent method yielded low SEM (1–2°) and MDC95 (3–6°) values, whereas the circle-fit/trigonometric methods showed larger errors. Most spinopelvic angles had moderate-to-excellent ICCs (0.65–0.98) with SEM/MDC95 values ≈2.1–4.5°/5.9–12.4°. Ground reaction force-referenced distances showed good ICCs and small intra-operator error (SEM: 3.8–4.8 mm; MDC95: 10.7–13.4 mm) but wider inter-session thresholds (SEM: 10.3–11.6 mm; MDC95: 28.6–32.8 mm). Bland & Altman biases were ~0, with narrower limits for the tangent (≈±5°) than circle-fit/trigonometric (≈±8–12°) methods. Curve tracking was consistent (RMSE: 2.7–3.7 mm, <5% amplitude), and SPM detected no point-wise differences. Conclusions: The A-Palp method demonstrated high reliability and repeatability for extracorporeal sagittal spinal and sacro-spinal evaluation. Variability was low across operators and sessions, supporting its use as a robust, non-invasive clinical and research tool.Keywords
This publication has 29 references indexed in Scilit:
- A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability ResearchJournal of Chiropractic Medicine, 2016
- Quantifying spinal gait kinematics using an enhanced optical motion capture approach in adolescent idiopathic scoliosisGait & Posture, 2016
- Sagittal spino-pelvic alignment in chronic low back painEuropean Spine Journal, 2011
- Equilibrium of the human body and the gravity line: the basicsEuropean Spine Journal, 2011
- Sagittal parameters of the spine: biomechanical approachEuropean Spine Journal, 2011
- Guidelines for Reporting Reliability and Agreement Studies (GRRAS) were proposedJournal of Clinical Epidemiology, 2011
- Precision of shoulder anatomical landmark calibration by two approaches: A CAST-like protocol and a new anatomical palpator methodGait & Posture, 2009
- A review of methods for quantitative evaluation of spinal curvatureEuropean Spine Journal, 2009
- Sample size requirements for estimating intraclass correlations with desired precisionStatistics in Medicine, 2002
- Least squares approximation by splines with free knotsBIT Numerical Mathematics, 1995