JMJack Monti

Jack Monti

*This is an algorithmically generated author record based on publicly available information.

Jack Monti has a total of 40 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Hydrogeology and water quality of the unconsolidated aquifer system in the lower Fall Creek valley, Tompkins County, New York

    by Joshua C. Woda, Brandon L. Graham, William M. Kappel, John H. Williams, Kristina Gutchess, Shannon R. Fisher, Jack Monti, Matthew Jennings, Laura M. DeMott

    The U.S. Geological Survey, in cooperation with Tompkins County and the Town of Dryden, conducted a hydrogeologic investigation of the lower Fall Creek unconsolidated aquifer system in Tompkins County, New York. This study is part of an ongoing effort to characterize major valley-fill aquifers in the region to support sustainable groundwater management. The lower Fall Creek valley, encompassing the Village of Freeville, the unincorporated communities of Etna, and the hamlets of McLean and Varna, has experienced moderate development and relies heavily on groundwater for residential, agricultural, and commercial use.The study area spans approximately 51 square miles along the boundary of the Allegheny Plateau and North Rim of the Allegheny Plateau physiographic provinces. The aquifer system, composed primarily of glacially derived sand and gravel deposits, includes both unconfined and confined aquifer units. For the approximately 2,300 people who live over the aquifers, groundwater is the sole source of drinking water. In some areas, such as the Village of Freeville, artesian conditions exist, with potentiometric heads exceeding 25 feet above land surface.This report describes the hydrogeologic framework, aquifer distribution, groundwater-flow dynamics, and water quality of the lower Fall Creek aquifer system. Groundwater is generally hard and contains elevated concentrations of redox-sensitive constituents, such as iron and manganese relative to U.S. Environmental Protection Agency secondary maximum contaminant levels. Arsenic was not detected above the U.S. Environmental Protection Agency maximum contaminant level during this study but remains a regional concern due to past detections in the study area and nearby aquifers. The findings provide data for local planners and resource managers to use in understanding and protecting this water resource.

  • Open Access

    Analysis of factors affecting plume remediation in a sole-source aquifer system, southeastern Nassau County, New York

    by Michael N. Fienen, Nicholas Corson-Dosch, Frederick Stumm, Paul E. Misut, Kalle Jahn, Jillian Troyer, Christopher E. Schubert, Donald A. Walter, Jason S. Finkelstein, Jack Monti, et al.

    Several plumes of dissolved, chlorinated solvents, including trichloroethylene, have been identified in a sole-source aquifer near the former Northrop Grumman Bethpage Facility and Naval Weapons Industrial Reserve Plant sites in southeastern Nassau County, New York. Past investigations have documented that the groundwater contamination originated from this industrial area and now extends to the south, in the direction of groundwater flow. The intermixed plumes are commonly referred to as the “Navy Grumman groundwater plume.” Detailed groundwater-flow modeling was needed for the New York State Department of Environmental Conservation (NYSDEC) to evaluate design options necessary for the construction, operation, optimization, maintenance, and monitoring of a groundwater extraction and treatment cleanup plan selected in a December 2019 Amended Record of Decision by the NYSDEC to comprehensively address these plumes.Consequently, the NYSDEC began a cooperative study with the U.S. Geological Survey in 2020 to better understand the local hydrogeologic framework using two independent approaches to characterize aquifer heterogeneity and update an existing regional groundwater-flow model to provide transient boundary conditions for new inset groundwater-flow models of the plume area. We developed these detailed inset models for the two independent aquifer characterizations using history-matching techniques coupled with a novel approach to risk-based management optimization of the remedial design. We also used the updated regional model to assess this optimized groundwater extraction and treatment design for potential saltwater intrusion.The ensembles of parameters resulting from history matching provided a platform with which to evaluate capture by water-supply and remedial wells using particle-tracking techniques. Using the ensemble to select a risk stance, we performed multiobjective optimization to identify various configurations of remedial pumping that are consistent with external constraints and that favor potentially competing objectives. Multiple solutions provide tradeoffs that NYSDEC can consider. In general, pumping redistribution may help to prevent further contamination migration downgradient. These and other study results are intended to support decisions for the remedial design focused on the local area encompassing the full extent of the Navy Grumman groundwater plume.

  • Open Access

    Simulation of groundwater flow in the Long Island, New York regional aquifer system for pumping and recharge conditions from 1900 to 2019

    by Donald A. Walter, Kalle L. Jahn, John P. Masterson, Sarken E. Dressler, Jason S. Finkelstein, Monti, Jr. Jack Monti

    The U.S. Geological Survey has developed a transient, groundwater-flow model that simulates hydrologic conditions in the Long Island aquifer system as part of an ongoing (since 2016) multiyear, cooperative investigation with the New York State Department of Environmental Conservation. The goals of this investigation are to assist stakeholders and resource managers to evaluate the response of the hydrologic system to changes in future hydraulic stresses. Responses in the hydrologic system include changes in water levels in the hydrogeologic units; discharge to streams, coastal waters, and subsurface infrastructure; and the extent of saline groundwater in the aquifers. Hydraulic stresses include future water-supply management and changes in land use and infrastructure.The numerical model synthesizes a diverse set of physiographic, geologic, climatic, land-use, and historical population, water use, and infrastructure data to physically represent the Long Island aquifer system from land surface to bedrock and to simulate annual hydrologic conditions between 1900 and 2019. A three-dimensional hydrogeologic framework was developed from existing and recently collected borehole geologic and geophysical data collected as part of a companion drilling program. Water-transmitting properties of the principal aquifer sediments were defined in three dimensions from new and existing lithologic logs. The distribution of recharge from precipitation was estimated from landscape characteristics and climate data. Anthropogenic recharge from wastewater, leaky infrastructure, and storm runoff were estimated from population, infrastructure, and pumping data.Water-use data, including well locations, depths, and pumping rates, were obtained from historical sources and records and used to estimate pumping stresses continuously in time and space, at an annual average time scale. The data were incorporated into a three-dimensional numerical model using the U.S. Geological Survey finite difference modeling code MODFLOW 6; the model encompassed all of Long Island and surrounding surface waters and simulated historical hydrologic conditions from 1900 to 2019.The calibration process involved trial and error adjustments using prior knowledge to improve general fit to observations followed by an inverse calibration to update and optimize input parameters, using an iterative ensemble smoother algorithm implemented in PEST++ version 5.0. This resulted in a model that generally was in good agreement with observed, dynamically varying hydrologic conditions from 1900 to 2019. The calibrated model was used to develop two base-case models for scenario testing of future, hypothetical conditions where one represented average-annual conditions, and one represented average-seasonal conditions from 2010 to 2019. The model representing average-annual conditions was modified further to represent an alternate sea-level position of 6 feet above the North American Vertical Datum of 1988, and the model representing average-seasonal conditions was modified to represent the average seasonal effects of a 5-year drought imposed upon current hydrologic conditions.Recharge is the sole source of water to the aquifer system; groundwater discharges to coastal water and streams and is withdrawn by pumped wells. Model-estimated annual recharge ranged from about 11 inches in 1965 to 41 inches in 1983. On average, from 2010 to 2019, about 23 percent of water was pumped from wells, and about 47 and 27 percent discharged to coastal waters and streams, respectively; the remaining 4 percent was water that moved into storage in the aquifer matrix.Water levels on Long Island vary naturally during time in response to changes in recharge; the amount of variation is largest in the interior of the island, in areas with highest water table altitudes near groundwater divides and lowest near streams and the coastal waters. The total range of water table altitudes on Long Island between 1900 and 2019 ranged from near 0 to more than 70 feet in western parts of Long Island. The largest range in altitudes is in New York City and is associated with areas of large historical withdrawals between the 1920s and the late 1980s. Water table altitudes generally varied by less than 10 feet in eastern Suffolk County, where the aquifer is under more natural conditions.Saltwater intrusion is of great concern on Long Island, particularly in western Long Island where both the unconfined and confined parts of the aquifer system have been intruded in response to large-scale groundwater withdrawals; however, the volume of freshwater in the islandwide aquifer system only has changed by about 5 percent between 1900 and 2019. The decadal change in the freshwater volume was largest during the early and mid-20th century, corresponding to the largest historical pumping, but that volume change did not exceed 1 percent.The negligible change in freshwater volume suggests that saltwater intrusion as of 2019 was limited at an islandwide scale but continues to occur in local areas of Queens and Nassau Counties, adversely affecting current water supplies and limiting future water supplies for affected communities. The regional groundwater model developed for this investigation is a tool that can be used to help determine the viability of current and future water supplies at a regional scale and can be used to support development of additional models at finer scale to support more focused assessments of groundwater sustainability.


  • Application of a soil-water-balance model to estimate annual groundwater recharge for Long Island, New York, 1900–2019

    by Jason S. Finkelstein, Jr. Jack Monti, John P. Masterson, Donald A. Walter

    A soil-water-balance (SWB) model was developed for Long Island, New York, to estimate the potential amount of annual groundwater recharge to the Long Island aquifer system from 1900 to 2019. The SWB model program is a computer code based on a modified Thornthwaite-Mather SWB approach and uses spatially and temporally distributed meteorological, land-cover, and soil properties as input to compute potential daily groundwater recharge. Simulated outputs indicate that island-wide potential groundwater recharge trends, as a percentage of precipitation, have increased approximately 3 percent during the 120-year period. The simulated results account for both climatic and land-cover changes that have occurred during the period. A change from undeveloped (forested land cover) to low- and medium-density residential land cover or land use increased potential groundwater recharge because of a decrease in evapotranspiration. During the 30-year period from 1900 to 1930, the simulated potential average groundwater recharge rate on Long Island was estimated to be 18.50 inches per year (in/yr), or a total of 1,243 million gallons per day, during the 30-year period from 1985 to 2015, the simulated potential average groundwater recharge rate estimate increased to 20.73 in/yr (a total of around 1,393 million gallons per day).During the 1900–2019 simulation period, the potential average annual groundwater recharge rate was about 19.24 in/yr. The data for that period included values for a 3-year meteorological drought from 1963 to 1965, where the mean precipitation was about 26.5 percent lower than the long-term average of 46.7 in/yr, and the potential groundwater recharge rate was about 12.3 in/yr. During a 3-year wet period from 1982 to 1984, where mean precipitation was about 19.6 percent higher than the long-term average, the estimated potential groundwater recharge rate was about 26.8 in/yr.


  • Simulation of groundwater flow in the regional aquifer system on Long Island, New York, for pumping and recharge conditions in 2005–15

    by Donald A. Walter, John P. Masterson, Jason S. Finkelstein, Jr. Jack Monti, Paul E. Misut, Michael N. Fienen

    A three-dimensional groundwater-flow model was developed for the aquifer system of Long Island, New York, to evaluate (1) responses of the hydrologic system to changes in natural and anthropogenic hydraulic stresses, (2) the subsurface distribution of groundwater age, and (3) the regional-scale distribution of groundwater travel times and the source of water to fresh surface waters and coastal receiving waters. The model also provides the groundwater flow components used to define model boundaries for possible inset models used for local-scale analyses.The three-dimensional, groundwater flow model developed for this investigation uses the numerical code MODFLOW–NWT to represent steady-state conditions for average groundwater pumping and aquifer recharge for 2005–15. The particle-tracking algorithm MODPATH, which simulates advective transport in the aquifer, was used to estimate groundwater age, delineate the areas at the water table that contribute recharge to coastal and freshwater bodies, and estimate total travel times of water from the water table to discharge locations.A three-dimensional, 1-meter (3.3-foot) topobathymetric model was used to determine land-surface altitudes for the island and seabed altitudes for the surrounding coastal waters. The mapped extents and surface altitudes of major geologic units were compiled and used to develop a three-dimensional hydrogeologic framework of the aquifer system, including aquifers and confining units. Lithologic data from deep boreholes and previous aquifer-test results were used to estimate the three-dimensional distribution of hydraulic conductivity in principal aquifers. Natural recharge from precipitation was estimated for 2005–15 using a modified Thornthwaite-Mather methodology as implemented in a soil-water balance model. Components of anthropogenic recharge—wastewater return flow, storm water inflow, and inflow from leaky infrastructure—also were estimated for 2005–15. Groundwater withdrawals for various sources, including public water supply, industrial, remediation, and agricultural, were compiled or estimated for the same period.These data were incorporated into the model development to represent the aquifer system geometry, boundaries, and initial hydraulic properties of the regional aquifers and confining units within the Long Island aquifer system. Average hydraulic conditions—water levels and streamflows—for 2005–15 were estimated using existing data from the U.S. Geological Survey National Water Information System database. Model inputs were adjusted to best match average hydrologic conditions using inverse methods as implemented in the parameter-estimating software PEST. The calibrated model was used to simulate average hydrologic conditions in the aquifer system for 2005–15.About 656 cubic feet per second of water was withdrawn on average annually for 2005–15 for water supply and an average of about 349 cubic feet per second of water recharged the aquifer annually from return flow and leaky infrastructure. Parts of New York City have drawdowns exceeding 25 feet, mostly because of urbanization and associated large decreases in recharge rates. Large areas in the western part of the island have drawdowns exceeding 10 feet, mostly from large groundwater withdrawals and sewering, which largely eliminates wastewater return flow. Water-table altitudes in eastern parts of the island increased by more than 2 feet in some areas as a result of wastewater return flow in unsewered areas and changes in land use. Changes in streamflows show a similar pattern as water-table altitudes. Streamflows generally decrease in western parts of the island where there are large drawdowns and increase in eastern parts of the island where water-table altitudes increase.


  • Open Access

    Water-table and potentiometric-surface altitudes in the upper glacial, Magothy, and Lloyd aquifers of Long Island, New York, April–May 2016

    by Michael D. Como, Jason S. Finkelstein, Simonette L. Rivera, Jack Monti, Ronald J. Busciolano

    The U.S. Geological Survey, in cooperation with State and local agencies, systematically collects groundwater data at varying measurement frequencies to monitor the hydrologic conditions on Long Island, New York. Each year during April and May, the U.S. Geological Survey completes a synoptic survey of water levels to define the spatial distribution of the water table and potentiometric surfaces within the three main water-bearing units underlying Long Island—the upper glacial, Magothy, and Lloyd aquifers—and the hydraulically connected Jameco and North Shore aquifers. These data and the maps constructed from them are commonly used in studies of the hydrology of Long Island and are used by water managers and suppliers for aquifer management and planning purposes.Water-level measurements made in 424 monitoring wells (observation and supply wells), 13 streamgages, and 2 lake gages across Long Island during April–May 2016 were used to prepare the maps in this report. Groundwater measurements were made by...


  • Hydrologic budget and conditions of Permian, Pennsylvanian, and Mississippian aquifers in the Appalachian Plateaus physiographic province

    by Kurt J. McCoy, Richard M. Yager, David L. Nelms, David E. Ladd, Jr. Jack Monti, Mark D. Kozar

    In response to challenges to groundwater availability posed by historic land-use practices, expanding development of hydrocarbon resources, and drought, the U.S. Geological Survey Groundwater Resources Program began a regional assessment of the Appalachian Plateaus aquifers in 2013 that incorporated a hydrologic landscape approach to estimate all components of the hydrologic system: surface runoff, base flow from groundwater, and interaction with atmospheric water (precipitation and evapotranspiration). This assessment was intended to complement other Federal and State investigations and provide foundational groundwater-related datasets in the Appalachian Plateaus. A regional Soil-Water-Balance model was constructed for a 160,000-square-mile study area that extended to the topographic divide of all streams originating outside but flowing into areas underlain by Appalachian Plateaus aquifers. The model incorporated soil, landscape, and climate variables to estimate an annual water budget for the 32-year period from 1980 to 2011 and was calibrated using base-flow data estimated by hydrograph separation techniques from 20...


  • Analysis of storm-tide impacts from Hurricane Sandy in New York

    by Christopher E. Schubert, Ronald J. Busciolano, Paul P. Hearn, Ami N. Rahav, Riley Behrens, Jason S. Finkelstein, Jack Monti, Amy E. Simonson

    The hybrid cyclone-nor’easter known as Hurricane Sandy affected the mid-Atlantic and northeastern United States during October 28-30, 2012, causing extensive coastal flooding. Prior to storm landfall, the U.S. Geological Survey (USGS) deployed a temporary monitoring network from Virginia to Maine to record the storm tide and coastal flooding generated by Hurricane Sandy. This sensor network augmented USGS and National Oceanic and Atmospheric Administration (NOAA) networks of permanent monitoring sites that also documented storm surge. Continuous data from these networks were supplemented by an extensive post-storm high-water-mark (HWM) flagging and surveying campaign. The sensor deployment and HWM campaign were conducted under a directed mission assignment by the Federal Emergency Management Agency (FEMA). The need for hydrologic interpretation of monitoring data to assist in flood-damage analysis and future flood mitigation prompted the current analysis of Hurricane Sandy by the USGS under this FEMA mission assignment. The analysis of storm-tide impacts focused on three distinct but related aspects of coastal flooding from Hurricane Sandy, including flooding inland along the tidal reach of the Hudson River. These aspects are (1) comparisons of peak storm-tide elevations to those of historical storms and to annual exceedance probabilities, (2) assessments of storm-surge characteristics, and (3) comparisons of maps of inundation extent that were derived from differing amounts of available storm-tide data. Most peak storm-tide elevations from Hurricane Sandy were greater than about 9.5 feet (ft) above North American Vertical Datum of 1988. Peak storm-tide elevations from Hurricane Sandy were compared with data for the intense nor’easter of December 11–13, 1992, and Hurricane Irene (August 27–28, 2011), which weakened to a tropical storm before arriving in New York. Peak storm-tide elevations from Hurricane Sandy were higher than those from the December 1992 nor’easter at 24 of 27 sites; most differences were greater than about 0.7 ft or 9 percent (above the historical storm tide). Peak storm-tide elevations from Hurricane Sandy were higher than those from Tropical Storm Irene at all sites; most differences were greater than about 2.5 ft or 48 percent. Data from permanent and temporary monitoring sites and HWM sites were compared with corresponding FEMA flood elevations for the 10-, 2-, 1-, and 0.2-percent annual exceedance probabilities in New York. Peak storm-tide elevations from Hurricane Sandy had annual exceedance probabilities less than or equal to 1 percent and (or) greater than 0.2 percent at a plurality of sites—184 of 413. Peak storm-tide elevations greater than or equal to the 0.2-percent flood elevation accounted for 81 of 413 sites. Peak storm-tide elevations less than the 10-percent flood elevation accounted for only 10 of 413 sites. Data from selected permanent monitoring sites in the USGS and NOAA networks were used to assess storm-surge magnitude associated with the peak storm tide, and magnitude and timing of the peak storm surge. Most magnitudes of the peak storm surge were greater than about 8.3 ft, and most magnitudes of the storm surge component of the peak storm tide were greater than about 7.8 ft. Timing of peak storm surge arrival with respect to local phase of tide controlled where the most extreme peak storm-tide levels and coastal flooding occurred. This finding has bearing not only for locations impacted by the highest storm tides from Hurricane Sandy, but also for those that had the greatest storm surges yet were spared the worst flooding because of fortuitous timing during this storm. Results of FEMA Hazus Program (HAZUS) flood loss analyses performed for New York counties were compared for extents of storm-tide inundation from Hurricane Sandy mapped (1) pre-storm, (2) on November 11, 2012, and (3) on February 14, 2013. The resulting depictions of estimated total building stock losses document how differing amounts of available USGS data affect the resolution and accuracy of storm-tide inundation extents. Using the most accurate results from the final (February 14, 2013) inundation extent, estimated losses range from $380 million to $5.9 billion for individual New York counties; total estimated aggregate losses are about $23 billion for all New York counties. Quality of the inundation extents used in HAZUS analyses has a substantial effect on final results. These findings can be used to inform future post-storm reconstruction planning and estimation of insurance claims.


  • Simulation of Variable-Density Ground-Water Flow and Saltwater Intrusion beneath Manhasset Neck, Nassau County, New York, 1905-2005

    by Jack Monti, Paul E. Misut, Ronald J. Busciolano

    The coastal-aquifer system of Manhasset Neck, Nassau County, New York, has been stressed by pumping, which has led to saltwater intrusion and the abandonment of one public-supply well in 1944. Measurements of chloride concentrations and water levels in 2004 from the deep, confined aquifers indicate active saltwater intrusion in response to public-supply pumping. A numerical model capable of simulating three-dimensional variable-density ground-water flow and solute transport in heterogeneous, anisotropic aquifers was developed using the U.S. Geological Survey finite-element, variable-density, solute-transport simulator SUTRA, to investigate the extent of saltwater intrusion beneath Manhasset Neck. The model is composed of eight layers representing the hydrogeologic system beneath Manhasset Neck. Four modifications to the area?s previously described hydrogeologic framework were made in the model (1) the bedrock-surface altitude at well N12191 was corrected from a previously reported value, (2) part of the extent of the Raritan confining unit was shifted, (3) part of the extent of the North Shore confining unit was shifted, and (4) a clay layer in the upper glacial aquifer was added in the central and southern parts of the Manhasset Neck peninsula. Ground-water flow and the location of the freshwater-saltwater interface were simulated for three conditions (time periods) (1) a steady-state (predevelopment) simulation of no pumping prior to about 1905, (2) a 40-year transient simulation based on 1939 pumpage representing the 1905-1944 period of gradual saltwater intrusion, and (3) a 60-year transient simulation based on 1995 pumpage representing the 1945-2005 period of stabilized withdrawals. The 1939 pumpage rate (12.1 million gallons per day (Mgal/d)) applied to the 1905-1944 transient simulation caused modeled average water-level declines of 2 and 4 feet (ft) in the shallow and deep aquifer systems from predevelopment conditions, respectively, a net decrease of 5.2 Mgal/d in freshwater discharge to offshore areas and a net increase of 6.9 Mgal/d of freshwater entering the model from the eastern, western, and southern lateral boundaries. The 1995 pumpage rate (43.3 Mgal/d) applied to the 1945-2005 transient simulation caused modeled average water-level declines of 5 and 8 ft in the shallow and deep aquifer systems from predevelopment conditions, respectively, a net decrease of 13.2 Mgal/d in freshwater discharge to offshore areas and a net increase of 30.1 Mgal/d of freshwater entering the model from the eastern, western, and southern lateral boundaries. The simulated decrease in freshwater discharge to the offshore areas caused saltwater intrusion in two parts of the deep aquifer system under Manhasset Neck. Saline ground water simulated in a third part of the deep aquifer system under Manhasset Neck was due to the absence of the North Shore confining unit near Sands Point. Simulated chloride concentrations greater than 250 milligrams per liter (mg/L) were used to represent the freshwater-saltwater interface, and the movement of this concentration was evaluated for transient simulations. The decrease in the 1905-1944 simulated freshwater discharge to the offshore areas caused the freshwater-saltwater interface in the deep aquifer system to advance landward more than 1,700 ft from its steady-state position in the vicinity of Baxter Estates Village, Long Island, New York. The decrease in the 1945-2005 simulated freshwater discharge to the offshore areas caused a different area of the freshwater-saltwater interface in the deep aquifer system to advance more than 600 ft from its steady-state position approximately 1 mile south of the Baxter Estates Village. However, the 1945-2005 transient simulation underestimates the concentration and extent of saltwater intrusion determined from water-quality samples collected from wells N12508 and N12793, where measured chloride concentrations increased from 625 and 18 mg/L in 1997 t